Filename: tfs 70ba.doc Version 1.0 VI TELEFILTER 18.08.2006 Filter specification TFS 70BA 1/5 Measurement condition Ambient temperature: Input power level: Terminating impedance: * Input: Output: External Coil: 23 0 C dBm 2900 || -3,8 pF 2900 || -3,8 pF 820 nH Characteristics Remark: The reference level for the relative attenuation arel of the TFS 70BA is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed at 70,0 MHz without any tolerance. The given values for both the relative attenuation arel and the group delay ripple have to be achieved at the frequencies given below even if the centre frequency fc is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc. Data typ. value Insertion loss (reference level) ae 3,7 Nominal frequency fN fC Centre frequency at ambient temperature PB Passband Pass band ripple 35 fN fN fN fN 60 90 450 500 dB max. 6,0 70,0 MHz - dB MHz 70,0 0,015 MHz fN 35 kHz 0,5 dB max. 1,0 dB arel Relative attenuation fN fN 70,002 tolerance / limit kHz ... fN ... fN 35 47 kHz kHz 0,5 2,0 dB dB max. max. 1,0 3,0 dB dB kHz kHz kHz kHz ... ... ... ... 90 450 500 10 kHz kHz kHz MHz 2,5 10 45 43 dB dB dB dB min. min. min. min. 1,0 3,0 35 40 dB dB dB dB max. 8 fN fN fN fN Input power level Operating temperature range OTR Storage temperature range - 5 C ... + 70C - 30 C ... + 90C 25 Frequency inversion temperature Temperature coefficient of frequency - TCf ** -0.043 dBm C ppm/K 2 *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. **) fc(Hz) = TCf(ppm/K2) x (T - To)2 x fTo (MHz). Generated: Checked / Approved: Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 70ba.doc Version 1.0 VI TELEFILTER 18.08.2006 Filter specification TFS 70BA 2/5 Filter characteristic 0 0 -7 -21 magnitude in dB magnitude in dB -14 -28 -35 -42 -49 -5 -10 -56 -63 -70 69 69.2 69.4 69.6 69.8 70 70.2 frequency in MHz 70.4 70.6 70.8 71 -15 69.9 69.95 70 70.05 frequency in MHz 70.1 Construction and pin connection (All dimensions in mm) 1 10 1,00,2 1,910,2 7,620,2 5 6 Date code 1,90,2 TFS 70BA U33 1,80,2 6,5 0,2 13,3 0,2 1 2 3 4 5 6 7 8 9 10 Ground Ground Ground Ground Output External Coil Ground Ground Ground Input Date code: U V W ... Year + week 2006 2007 2008 50 Test circuit 10 L1 C1 5 SAW L2 6 C2 1, 2, 3, 4, 7, 8, 9 Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 70ba.doc Version 1.0 VI TELEFILTER 18.08.2006 Filter specification TFS 70BA 3/5 Stability characteristics, reliability 100% Screening Tests : After the following tests the filter shall meet the whole specification. Electrical tests after test 4, test 5 and 7. 1. Internal Visual Inspection: according to MIL-STD-883 method 2017 2. Stabilization Bake: 16 hrs at 125C under Vacuum according to MIL-STD-883 Method 1008 Condition B 3. Temperature Cycling: -55 C to 125C / 30 min. each / 10 cycles DIN IEC 68 part 2 - 14 Test N equivalent MIL-STD-202 Method 107 4. Burn-in: 160hrs at 125C ( no input power ) according to MIL-STD-883 Method 1015 5. Seal test: gross leak bubble test - Fluorocarbon liquid at 125C 5C MIL-STD-202 Method 112 Condition D Fine leak spot test - Helium detector according to MIL-STD-202 Method 112 Condition C 6. External Visual Inspection: according to MIL-STD-883 method 2009 Qualification Tests : 1. Resistance to solder heat (reflow): reflow possible: three times max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; 2. Vibration: 10 Hz to 2000 Hz, 1,5 mm or max 20g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 2 - 6 3. Shock: 500g, 1 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 , 7. Radiation: 100 krad , ESCC Detail Specification No.22900 Packing Tape & Reel: IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer: 1700 min. 300 mm min. 500 mm min. 300 mm Pull Off Direction Tape (all dimensions in mm) W : 24,00 +0,30/-0,10 Po : 4,00 0,1 Do : 1,50 +0,1/-0 E : 1,75 0,10 F : 11,50 0,10 G(min) : 0,60 P2 : 2,00 0,1 P1 : 12,00 0,1 D1(min) : 1,50 Ao : 7,10 0,10 Bo : 13,90 0,10 Ct : 21,5 0,1 P1 Date Code Po Do P2 W G Ct Bo F G E t Ko Typ PIN Marker D1 Ao W 2 Reel (all dimensions in mm) A : 330 W1 : 24,4 +2/-0 W2(max) : 30,4 N(min) : 60 C : 13,0 +0,5/-0,2 A C N W 1 The minimum bending radius is 45 mm. Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 70ba.doc Version 1.0 VI TELEFILTER 18.08.2006 Filter specification TFS 70BA 4/5 Air reflow temperature conditions Conditions Average ramp-up rate (30C to 217C) > 100C > 150C > 217C Peak temperature Time within 5C of actual peak temperature Cool-down rate (Peak to 50C) Time from 30C to Peak temperature Exposure less than 3C/second between 300 and 600 seconds between 240 and 500 seconds between 30 and 150 seconds max. 260C between 10 and 30 seconds less than 6C/second no greater than 300 seconds Chip-mount air reflow profile Temperature / C max. 260C 217C max. 300 s 10 ... 30 s Time / s 30 ... 150 s Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 70ba.doc VI TELEFILTER Version 1.0 Filter specification 18.08.2006 TFS 70BA 5/5 History Version Reason of Changes Name Date 1.0 - Generation of filter specification Strehl 18.08.2006 Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.