Features
n Patented multi-stage protection
n Balanced TRIGARD®
n Patented Switch-Grade Fail-Short Device
n Quick response and high energy handling
n Ideal for high-speed networks in high
exposure environments
n Listed per UL 497 (File: 53117)
n Meets test requirements of Telcordia
GR 974, GR1361, SBC SR 5165 and
RUS PE-80
n Telcordia Analysis report DA-1547
n Solid brass, gold-plated pins
n Test point access option
n Sealed option for harsh environments
Characteristics
MSP® 2410 Series - 5-Pin Multi-Stage Protector
Specifications are subject to change without notice.
Users should verify actual device performance in their specific applications.
The products described herein and this document are subject to specific legal disclaimers as set forth on the last page of this document, and at www.bourns.com/docs/legal/disclaimer.pdf.
The Bourns® MSP® 5-Pin Multi-Stage Protector is the latest generation telecommunications protector for high performance and long
life in overvoltage protection of copper pair voice-band and high-speed data circuits. The Bourns® MSP® protector combines the
advantages of gas tube and solid state protection while integrating three advanced technologies: a proprietary high-efciency gas
discharge tube, precision matched metal oxide varistors and a patented Switch-Grade Fail-Short mechanism. The Switch-Grade Fail-
Short mechanism ensures superior thermal protection with fast acting, highly reliable response to thermal overload conditions. This
combined technology provides lower capacitance, higher reliability and longer life than competitive hybrid technologies.
The Bourns® MSP® Model 2410 Series can be used universally for POTS and high speed data, e.g. ISDN, ADSL, ADSL2+, VDSL,
VDSL2, other xDSL protocols and high speed Ethernet. Bourns® MSP® technology provides unparalleled overvoltage protection with
low loss on paired copper communications circuits. The 2410 series is the most economical, reliable and effective choice for overvolt-
age protection of copper pair circuits.
Test Methods per UL 497, CSA C22.2, Telcordia GR 974, 1361 and SBC SR 5165.
DC Breakdown ............................................................................................................................................... 300-400 V
AC Breakdown @ 60 Hz ................................................................................................................................ 300-400 V
Impulse Breakdown
100 V/µs .................................................................................................................................................... 600 V
1000 V/µs .................................................................................................................................................. 650 V
Insulation Resistance @ 100 Vdc .................................................................................................................. >1 GΩ
Insertion Loss @ 100 MHz ............................................................................................................................. <0.4 dB1
Return Loss @ 100 MHz ................................................................................................................................ >14 dB1
Capacitance Tip to Ring @ 1 MHz ................................................................................................................. 10 pF typical
Capacitance Tip or Ring to Ground @ 1 MHz ................................................................................................ 20 pF typical
Impulse Reset 5
52 V, 260 mA ............................................................................................................................................. <10 ms
135 V, 200 mA ........................................................................................................................................... <10 ms
150 V, 200 mA ........................................................................................................................................... <150 ms
Impulse Life Characteristics (Tip and Ring to Ground Simultaneously)
10 to 100 A, 10/1000 µs ............................................................................................................................ >3000 operations2
300 A, 10/1000 µs ..................................................................................................................................... >1000 operations2
500 A, 10/1000 µs ..................................................................................................................................... >1000 operations4
2,000 A, 10/250 µs .................................................................................................................................... >100 operations2
5,000 A, 20/100 µs .................................................................................................................................... >10 operations2
20,000 A, 8/20 µs ...................................................................................................................................... >10 operations4
AC Life Characteristics (Tip and Ring to Ground Simultaneously)
0.5 A rms continuous ................................................................................................................................. >30 seconds
1 A rms, 1 second, 600 ft. cable ................................................................................................................ >60 seconds
1 A rms, 1 second, 1 mile cable ................................................................................................................. >60 operations
10 A rms, 1 second .................................................................................................................................... >5 operations
65 A rms, 11 cycles .................................................................................................................................... >1 operation3
120 A rms, 0.1 second ............................................................................................................................... 1 operation
High Current Capability and Thermal Operation (Tip and Ring to Ground,
Vented or Non-Vented Gas Tube) .................................................................................................................. >30 A rms, simultaneously
Storage and Operating Temperature .............................................................................................................. -55 to +85 °C
Telcordia analyzed for controlled (non-sealed) and uncontrolled, high-exposure (sealed) environments per GR 974 and SBC SR 5165.
Telcordia Technical Analysis Report DA-1547.
Notes:
1 Tested according to Category 5 requirements 4 RUS (REA) PE-80
2 Exceeds Telcordia (Bellcore) GR 1361 5 Network applied
3 Surpasses Telcordia GR 974 Line to Line voltage is approximately 1.8 to 2 times the stated Line to Ground
breakdown voltage.
WARNING Cancer and Reproductive Harm - www.P65Warnings.ca.gov
19.0
(0.75)
11.2
(0.440)
5.6
(0.220)
7.11
(.28) DP.
RAD. 1.91
(.075)
4.45
(.175)
9.53
(.375)
11.12
(.44)
6.10
(.24) 3.30
(.13)
5.28
(.208)
42.17
(1.66)
29.9
(1.18)
10.2
(0.40)
2410-3 MODULE
5.1
(0.20)
30.99
(1.22)
24.9
(0.98)
10.2
(0.40)
2410-7 MODULE
5.1
(0.20)
11.2
(0.44)
12.8
(0.50)
2.2
(.085)
DIA. 2 PLCS. 2.3
(.092)
DIA. 5 PLCS.
5.59
(.22)
.432
(.017) 6.73
(.265)
3.6
(0.14)
6.1
(0.240)
5.7
(0.223)
6.15
(0.24)
“MSP” and “TRIGARD” are registered trademarks of Bourns, Inc.
Specifications are subject to change without notice.
Users should verify actual device performance in their specific applications.
The products described herein and this document are subject to specific legal disclaimers as set forth on the last page of this document, and at www.bourns.com/docs/legal/disclaimer.pdf.
MSP® 2410 Series - 5-Pin Multi-Stage Protector
Product Dimensions
REV. P 05/19
DIMENSIONS: MM
(INCHES)
How To Order
2410 - X XX - G - XXX - XX
Model Number Designator
Module Length
3 = Standard: 52.37 mm (2.06 in.) 7 = Special Short: 41.19 mm (1.62 in.)
Housing Color/Circuit Type
1 = Black/Standard 6 = Blue/Standard 10 = Yellow/Standard
3 = Red/Special 9 = Orange/Standard Service (non-Bridgelifter)
Pin Plating
G = Gold Plated
Protector Type
MSP® = Multi-Stage Protector BC = Balanced Capacitance*
Special Options
S = Sealed Case ST = Sealed Case and Test Points**
T = Test Points**
*For use on DSL Systems that require balanced capacitance of ≤1 pF.
**T and ST options are not available on 2410-7x short module.
19.0
(0.75)
11.2
(0.440)
5.6
(0.220)
7.11
(.28) DP.
RAD. 1.91
(.075)
4.45
(.175)
9.53
(.375)
11.12
(.44)
6.10
(.24) 3.30
(.13)
5.28
(.208)
42.17
(1.66)
29.9
(1.18)
10.2
(0.40)
2410-3 MODULE
5.1
(0.20)
30.99
(1.22)
24.9
(0.98)
10.2
(0.40)
2410-7 MODULE
5.1
(0.20)
11.2
(0.44)
12.8
(0.50)
2.2
(.085)
DIA. 2 PLCS. 2.3
(.092)
DIA. 5 PLCS.
5.59
(.22)
.432
(.017) 6.73
(.265)
3.6
(0.14)
6.1
(0.240)
5.7
(0.223)
6.15
(0.24)
Legal Disclaimer Notice
This legal disclaimer applies to purchasers and users of Bourns® products manufactured by or on behalf of Bourns, Inc. and its
afliates (collectively, “Bourns”).
Unless otherwise expressly indicated in writing, Bourns® products and data sheets relating thereto are subject to change
without notice. Users should check for and obtain the latest relevant information and verify that such information is current and
complete before placing orders for Bourns® products.
The characteristics and parameters of a Bourns® product set forth in its data sheet are based on laboratory conditions, and
statements regarding the suitability of products for certain types of applications are based on Bourns’ knowledge of typical
requirements in generic applications. The characteristics and parameters of a Bourns® product in a user application may vary
from the data sheet characteristics and parameters due to (i) the combination of the Bourns® product with other components
in the user’s application, or (ii) the environment of the user application itself. The characteristics and parameters of a Bourns®
product also can and do vary in different applications and actual performance may vary over time. Users should always verify
the actual performance of the Bourns® product in their specic devices and applications, and make their own independent
judgments regarding the amount of additional test margin to design into their device or application to compensate for
differences between laboratory and real world conditions.
Unless Bourns has explicitly designated an individual Bourns® product as meeting the requirements of a particular industry
standard (e.g., ISO/TS 16949) or a particular qualication (e.g., UL listed or recognized), Bourns is not responsible for any
failure of an individual Bourns® product to meet the requirements of such industry standard or particular qualication. Users of
Bourns® products are responsible for ensuring compliance with safety-related requirements and standards applicable to their
devices or applications.
Bourns® products are not recommended, authorized or intended for use in nuclear, lifesaving, life-critical or life-sustaining ap-
plications, nor in any other applications where failure or malfunction may result in personal injury, death, or severe property or
environmental damage. Unless expressly and specically approved in writing by two authorized Bourns representatives on a
case-by-case basis, use of any Bourns® products in such unauthorized applications might not be safe and thus is at the user’s
sole risk. Life-critical applications include devices identied by the U.S. Food and Drug Administration as Class III devices and
generally equivalent classications outside of the United States.
Bourns expressly identies those Bourns® standard products that are suitable for use in automotive applications on such
products’ data sheets in the section entitled “Applications.” Unless expressly and specically approved in writing by two
authorized Bourns representatives on a case-by-case basis, use of any other Bourns® standard products in an automotive
application might not be safe and thus is not recommended, authorized or intended and is at the user’s sole risk. If Bourns
expressly identies a sub-category of automotive application in the data sheet for its standard products (such as infotainment
or lighting), such identication means that Bourns has reviewed its standard product and has determined that if such Bourns®
standard product is considered for potential use in automotive applications, it should only be used in such sub-category of
automotive applications. Any reference to Bourns® standard product in the data sheet as compliant with the AEC-Q standard
or “automotive grade” does not by itself mean that Bourns has approved such product for use in an automotive application.
Bourns® standard products are not tested to comply with United States Federal Aviation Administration standards generally
or any other generally equivalent governmental organization standard applicable to products designed or manufactured for
use in aircraft or space applications. Bourns expressly identies Bourns® standard products that are suitable for use in aircraft
or space applications on such products’ data sheets in the section entitled “Applications.” Unless expressly and specically
approved in writing by two authorized Bourns representatives on a case-by-case basis, use of any other Bourns® standard
product in an aircraft or space application might not be safe and thus is not recommended, authorized or intended and is at the
user’s sole risk.
The use and level of testing applicable to Bourns® custom products shall be negotiated on a case-by-case basis by Bourns and
the user for which such Bourns® custom products are specially designed. Absent a written agreement between Bourns and the
user regarding the use and level of such testing, the above provisions applicable to Bourns® standard products shall also apply
to such Bourns® custom products.
Users shall not sell, transfer, export or re-export any Bourns® products or technology for use in activities which involve the
design, development, production, use or stockpiling of nuclear, chemical or biological weapons or missiles, nor shall they use
Bourns® products or technology in any facility which engages in activities relating to such devices. The foregoing restrictions
apply to all uses and applications that violate national or international prohibitions, including embargos or international
regulations. Further, Bourns® products and Bourns technology and technical data may not under any circumstance be
exported or re-exported to countries subject to international sanctions or embargoes. Bourns® products may not, without prior
authorization from Bourns and/or the U.S. Government, be resold, transferred, or re-exported to any party not eligible
to receive U.S. commodities, software, and technical data.
To the maximum extent permitted by applicable law, Bourns disclaims (i) any and all liability for special, punitive, consequential,
incidental or indirect damages or lost revenues or lost prots, and (ii) any and all implied warranties, including implied warranties
of tness for particular purpose, non-infringement and merchantability.
For your convenience, copies of this Legal Disclaimer Notice with German, Spanish, Japanese, Traditional Chinese and Simplied Chinese
bilingual versions are available at:
Web Page: http://www.bourns.com/legal/disclaimers-terms-and-policies
PDF: http://www.bourns.com/docs/Legal/disclaimer.pdf
C1753 05/17/18R