Remote Configuration
Use the remote function to configure the sensor remotely or to disable the push button for security. Connect the white wire
of the sensor to ground (0V dc), through a remote programming switch. Pulse the remote line according to the diagrams in
the configuration procedures. The length of the individual programming pulses is equal to the value T: 0.04 seconds ≤ T ≤
0.8 seconds
Push Button Enable/Disable
The remote input may be used to disable the sensor push button to prevent unauthorized adjustment. Connect the white
wire of the sensor as described above to perform the procedure below to either enable or disable the feature.
Push Button Enable/Disable
Push Button ( 0.04
seconds ≤ "Click" ≤ 0.8
seconds)
Remote Line ( 0.04 seconds ≤ T
≤ 0.8 seconds) Result
Not available From Run mode, four-pulse the
remote line.
Sensor toggles between enable/disable settings and
returns to RUN mode.
Power LED: Flashes 3x, then ON Green
Output LED: OFF,2 then ON or OFF, depending on
output state
Returning to RUN Mode without Saving Settings
Exit Static TEACH and Set modes after the automatic 60-second time-out or by manually exiting the process. To manual
exit, press and hold the push button (or hold the remote line low) for 2 seconds. The sensor returns to Run mode without
saving any new settings.
Sensor Setup
Access setup functions directly from Run mode using the following procedures.
30 ms OFF-Delay (Pulse Stretcher) Enable/Disable
Push Button (0.04 seconds ≤
“Click” ≤ 0.8 seconds) Remote Line (0.04 seconds ≤ T ≤
0.8 seconds) Results
From Run mode, six-click the
push button. From Run mode, six-pulse remote line.
Sensor toggles between enable/disable settings and
returns to Run mode.
Power LED: Flashes 3x, then ON Green
Output LED: Enabled – ON, 3
Disabled – OFF, 3
Then ON or OFF, depending on output state
Light-Operate/Dark-Operate Select
Push Button (0.04 seconds ≤
“Click” ≤ 0.8 seconds) Remote Line (0.04 seconds ≤ T ≤
0.8 seconds) Results
From Run mode, seven-click the
push button. From Run mode, seven-pulse remote
line.
Sensor toggles between Light-/Dark-Operate settings
and returns to Run mode.
Power LED: Flashes 3x, then ON Green
Output LED: Light Operate – ON, 3
Dark Operate – OFF, 3
Then ON or OFF, depending on output state
2Initial output LED condition is simultaneous with Power LED 3-flash
3Initial Output LED condition is simultaneous with Power LED 3-flash.
WORLD-BEAM® QS18E Series
P/N 136564 Rev. C www.bannerengineering.com - tel: 763-544-3164 3