LM96194 LM96194 TruTherm Hardware Monitor with PI Fan Control for Workstation Management Literature Number: SNAS360A LM96194 August 6, 2010 TruThermTMTM Hardware Monitor with PI Fan Control for Workstation Management 1.0 General Description The LM96194 hardware monitor has a two wire digital interface compatible with SMBus 2.0. Using a ADC, the LM96194 measures the temperature of four remote diode connected transistors as well as its own die and 9 power supply voltages. The LM96194 has new TruTherm technology that supports precision thermal diode measurements of processors on sub-micron processes. To set fan speed, the LM96194 has two PWM outputs that are each controlled by up to six temperature zones. The fancontrol algorithm can be based on a lookup table, PI (proportional/integral) control loop, or a combination of both. The LM96194 includes digital filters that can be invoked to smooth temperature readings for better control of fan speed such that acoustical noise is minimized. The LM96194 has four tachometer inputs to measure fan speed. Limit and status registers for all measured values are included. The LM96194 includes most of the features of the LM94, dual CPU motherboard server management ASIC, such as measurement and control support for dynamic Vccp monitoring for VRD10/11 and PROCHOT but is targeted for single processor systems. 2.0 Features 2 PWM fan speed control outputs 4 fan tachometer inputs Processor thermal throttling (PROCHOT) monitoring Dynamic VID monitoring (6/7 VIDs per processor) supports VRD10.2/11 8 general purpose I/Os: -- 4 can be configured as fan tachometer inputs -- 2 can be configured to connect to processor THERMTRIP -- 2 are standard GPIOs that could be used to monitor IERR signal A general purpose inputs that can be used to monitor the 7th VID signal for VRD11 Limit register comparisons of all monitored values 2-wire serial digital interface, SMBus 2.0 compliant Supports byte/block read and write Selectable slave address (tri-level pin selects 1 of 3 possible addresses) ALERT output supports interrupt or comparator modes LLP-48 package XOR-tree test mode 3.0 Key Specifications ADC architecture Monitors 9 power supplies Monitors 4 remote thermal diodes and 2 LM60 New TruTherm technology support for precision thermal diode measurements Internal ambient temperature sensing Programmable autonomous fan control based on temperature readings with fan boost support Fan boost support on tachometer limit error event Fan control based on 13-step lookup table or PI Control Loop or combination of both PI fan control loop supports Tcontrol Temperature reading digital filters 0.5C digital temperature sensor resolution 0.0625C filtered temperature resolution for fan control Voltage Measurement Accuracy Temperature Resolution Temperature Sensor Accuracy Temperature Range: LM96194 Operational Remote Temp Accuracy Power Supply Voltage Power Supply Current 2% FS (max) 9-bits, 0.5C 2.5 C (max) -40C to +85C -40C to +125C +3.0V to +3.6V 1.6 mA 4.0 Applications Servers Workstations Processor based equipment TruThermTM is a trademark of National Semiconductor Corporation. Intel CorporationTM is a trademark of Intel Corporation. PentiumTM is a trademark of Intel Corporation. AMDTM is a registered trademark of Advanced Micro Devices, Inc. (c) 2010 National Semiconductor Corporation 201944 www.national.com LM96194 TruThermTM Hardware Monitor with PI Fan Control for Workstation Management PRELIMINARY LM96194 5.0 Ordering Information Order Number NS Package Number Transport media LM96194CISQ SQA48A 250 units in rail LM96194CISQX SQA48A 2500 units in tapeand-reel 6.0 Block Diagram The block diagram of LM96194 hardware is illustrated below. The hardware implementation is a single chip ASIC solution. 20194401 www.national.com 2 LM96194 7.0 Application The system diagram show in Figure 1 is a single processor workstation example. 20194405 FIGURE 1. Workstation Management 3 www.national.com LM96194 8.0 Connection Diagram 56 Pin TSSOP 20194402 NS Package NSQ48A Top View NS Order Numbers: LM96194CISQ (250 units per rail), or LM96194CISQX (2500 units per tape-and-reel) www.national.com 4 LM96194 9.0 Pin Descriptions Symbol Pin # Type Function PROCHOT 1 Digital I/O (OpenDrain) Connected to CPU1 PROCHOT (processor hot) signal through a bidirectional level shifter. Supports TTL input logic levels and AGTL compatible input logic levels. GND 2 Ground All grounds need to be tied together at the chip then taken to a low noise system ground. A voltage difference between grounds may cause erroneous results. GND 3 Ground All grounds need to be tied together at the chip then taken to a low noise system ground. A voltage difference between grounds may cause erroneous results. GND 4 Ground All grounds need to be tied together at the chip then taken to a low noise system ground. A voltage difference between grounds may cause erroneous results. GND 5 Ground All grounds need to be tied together at the chip then taken to a low noise system ground. A voltage difference between grounds may cause erroneous results. GND 6 Ground All grounds need to be tied together at the chip then taken to a low noise system ground. A voltage difference between grounds may cause erroneous results. GPIO_0/TACH1 7 Digital I/O (OpenDrain) Can be configured as fan tach input or a general purpose open-drain digital I/O. GPIO_1/TACH2 8 Digital I/O (OpenDrain) Can be configured as fan tach input or a general purpose open-drain digital I/O. GPIO_2/TACH3 9 Digital I/O (OpenDrain) Can be configured as fan tach input or a general purpose open-drain digital I/O. GPIO_3/TACH4 10 Digital I/O (OpenDrain) Can be configured as fan tach input or a general purpose open-drain digital I/O.. GPIO_4 / THERMTRIP 11 Digital I/O (OpenDrain) A general purpose open-drain digital I/O. Can be configured to monitor a CPU's THERMTRIP signal to mask other errors. Supports TTL input logic levels and AGTL compatible input logic levels. GPIO_5 12 Digital I/O (OpenDrain) A general purpose open-drain digital I/O. Supports TTL input logic levels and AGTL compatible input logic levels. GPIO_6 13 Digital I/O (OpenDrain) Can be used to detect the state of CPU's IERR or a general purpose opendrain digital I/O. Supports TTL input logic levels and AGTL compatible input logic levels. GPIO_7 14 Digital I/O (OpenDrain) A general purpose open-drain digital I/O. Supports TTL input logic levels and AGTL compatible input logic levels. VRD1_HOT 15 Digital Input CPU1 voltage regulator HOT. Supports TTL input logic levels and AGTL compatible input logic levels. GND 16 Ground Input All grounds need to be tied together at the chip then taken to a low noise system ground. A voltage difference between grounds may cause erroneous results. VID6/GPI9 17 Digital Input CPU VID6 input. Could also be used as a general purpose input to trigger an error event. Supports TTL input logic levels and AGTL compatible input logic levels. SMBDAT 18 Digital I/O (OpenDrain) Bidirectional System Management Bus Data. Output configured as 5V tolerant open-drain. SMBus 2.0 compliant. SMBCLK 19 Digital Input System Management Bus Clock. Driven by an open-drain output, and is 5V tolerant. SMBus 2.0 Compliant. ALERT/XtestOut 20 Digital Output (OpenDrain) Open-drain ALERT output used in an interrupt driven system to signal that an error event has occurred. Masked error events do not activate the ALERT output. When in XOR tree test mode, functions as XOR Tree output. 5 www.national.com LM96194 Symbol Pin # Type Function RESET 21 Digital I/O (OpenDrain) Open-drain reset output when power is first applied to the LM96194. Used as a reset for devices powered by 3.3V stand-by. After reset, this pin becomes a reset input. See Section (TBD) for more information. If this pin is not used, connection to an external resistive pull-up is required to prevent LM96194 malfunction. AGND 22 GROUND Input Analog Ground. All grounds need to be tied together at the chip then taken to a low noise system ground. A voltage difference between grounds may cause erroneous results. REMOTE1- 23 Remote Thermal Diode_1- Input (CPU THERMDC) This is the negative input (current sink) from both of the CPU thermal diodes. Connected to THERMDC pin of Pentium processor or the emitter of a diode connected MMBT3904 NPN transistor. Serves as the negative input into the A/D for thermal diode voltage measurements. A 100 pF capacitor is optional and can be connected between REMOTE1- and REMOTE1+. REMOTE1a+ 24 Remote Thermal Diode_1a+ I/O (CPU THERMDA1) This is a positive connection to the first CPU thermal diode. Serves as the positive input into the A/D for thermal diode voltage measurements. It also serves as a current source output that forward biases the thermal diode. Connected to THERMDA pin of Pentium processor or the base of a diode connected MMBT3904 NPN transistor. A 100 pF capacitor is optional and can be connected between REMOTE1- and each REMOTE1+. REMOTE2- 25 Remote Thermal Diode_2 - Input This is the negative input (current sink) from both of the CPU2 thermal diodes. Connected to THERMDC pins of Pentium processor or the emitter of a diode connected MMBT3904 NPN transistor. Serves as the negative input into the A/D for thermal diode voltage measurements. A 100 pF capacitor is optional and can be connected between REMOTE2- and each REMOTE2+. REMOTE2a+ 26 Remote Thermal Diode_2a + I/O This is a positive connection to the third thermal diode. Serves as the positive input into the A/D for thermal diode voltage measurements. It also serves as a current source output that forward biases the thermal diode. Connected to THERMDA pin of Pentium processor or the base of a diode connected MMBT3904 NPN transistor. A 100 pF capacitor is optional and can be connected between REMOTE2- and REMOTE2+. AD_IN1/REMOTE1b+ 27 Analog Input (+12V1 or Analog Input for +12V Rail 1 monitoring, for CPU1 voltage regulator. CPU1 THERMDA2) External attenuation resistors required such that 12V is attenuated to 0.927V for nominal 3/4 scale reading. This pin may also serve as the second positive thermal diode input for the CPU. AD_IN2/REMOTE2b+ 28 Analog Input or Remote Thermal Diode_2b + I/O Analog Input for +12V Rail 2 monitoring. External attenuation resistors required such that 12V is attenuated to 0.927V for nominal 3/4 scale reading. This pin may also serve as the fourth positive thermal diode input. AD_IN3 29 Analog Input (+12V3) Analog Input for +12V Rail 3, for Memory/3GIO slots. External attenuation resistors required such that 12V is attenuated to 0.927V for nominal 3/4 scale reading. AD_IN4 (Vccp) 30 Analog Input (CPU1_Vccp) Analog input for +Vccp (processor voltage) monitoring. AD_IN5 31 Analog Input (+3.3V) Analog input for +3.3V monitoring, nominal 3/4 scale reading GND 32 Ground All grounds need to be tied together at the chip then taken to a low noise system ground. A voltage difference between grounds may cause erroneous results. GND 33 Ground All grounds need to be tied together at the chip then taken to a low noise system ground. A voltage difference between grounds may cause erroneous results. GND 34 Ground All grounds need to be tied together at the chip then taken to a low noise system ground. A voltage difference between grounds may cause erroneous results. www.national.com 6 Pin # Type Function AD_IN6 35 Analog Input (Mem_Vtt) Analog input for +0.984V monitoring, nominal 3/4 scale reading. AD_IN7 36 Analog Input (Gbit_Core) Analog input for +0.984V S/B monitoring, nominal 3/4 scale reading. AD_IN8 37 Analog Input (-12V) Analog input for -12V monitoring. External resistors required to scale to positive level. Full scale reading at 1.236V, , nominal 3/4 scale reading. This pin may also be used to monitor an analog temperature sensor such as the LM60, since readings from this input can be routed to the fan control logic. Address Select 38 3 level analog input This input selects the lower two bits of the LM96194 SMBus slave address. 3.3V SB (AD_IN8) 39 POWER (VDD) +3.3V standby power VDD power input for LM96194. Generally this is connected to +3.3V standby power. The LM96194 can be powered by +3.3V if monitoring in low power states is not required, but power should be applied to this input before any other pins. This pin also serves as the analog input to monitor the 3.3V stand-by (SB) voltage. It is necessary to bypass this pin with a 0.1 F in parallel with 100 pF. A bulk capacitance of 10 F should be in the near vicinity. The 100 pF should be closest to the power pin. GND 40 Ground Digital Ground. All grounds need to be tied together at the chip then taken to a low noise system ground. A voltage difference between grounds may cause erroneous results. PWM1 41 Digital Output (OpenDrain) Fan control output 1. PWM2 42 Digital Output (OpenDrain) Fan control output 2 VID0/VID7 43 Digital Input Voltage Identification signal from the processor. Supports TTL input logic levels and AGTL compatible input logic levels. VID1 44 Digital Input Voltage Identification signal from the processor. Supports TTL input logic levels and AGTL compatible input logic levels. VID2 45 Digital Input Voltage Identification signal from the processor. Supports TTL input logic levels and AGTL compatible input logic levels. VID3 46 Digital Input Voltage Identification signal from the processor. Supports TTL input logic levels and AGTL compatible input logic levels. VID4 47 Digital Input Voltage Identification signal from the processor. Supports TTL input logic levels and AGTL compatible input logic levels. VID5 48 Digital Input Voltage Identification signal from the processor. Supports TTL input logic levels and AGTL compatible input logic levels. The over-score indicates the signal is active low ("Not"). 10.0 Server Terminology A/D Analog to Digital Converter FSB Front side bus ACPI Advanced Configuration and Power Interface FW Firmware Gb Gigabit ALERT SMBus signal to bus master that an event occurred that has been flagged for attention. GB Gigabyte Gbe Gigabit Ethernet ASF Alert Standard Format GPI General purpose input BMC Baseboard Management Controller GPIO General purpose I/O BW Bandwidth HW Hardware DIMM Dual in line memory module I2C Inter integrated circuit (bus) DP Dual-processor LAN Local area network ECC Error checking and correcting LSb Least Significant Bit FRU Field replaceable unit LSB Least Significant Byte 7 www.national.com LM96194 Symbol LM96194 LVDS Low-Voltage Differential Signaling P/S Power Supply LUT Look-Up Table PCI PCI Local Bus Mb Megabit PDB Power Distribution Board MB Megabyte POR Power On Reset MP Multi-processor PS Power Supply MSb Most Significant Bit MSB Most Significant Byte MTBF Mean time between failures SMBCLK and These signals comprise the SMBus SMBDAT interface (data and clock) See the SMBus Interface section for more information. MTTR Mean time to repair VRD NIC Network Interface Card (Ethernet Card) OS Operating system Voltage Regulator Down - regulates Vccp voltage for a CPU 11.0 Recommended Implementation 20194406 Recommended implementation without thermal diode connections www.national.com 8 LM96194 20194407 Note: 100 pF cap across each thermal diode is optional and should be placed close to the LM96194, if used. The maximum capacitance between thermal diode pins is 300 pF. Thermal diode recommended implementation 9 www.national.com LM96194 The PROCHOT, tachometer and dynamic VID/Vccp monitoring is performed independently of the analog and temperature monitoring cycle. 12.0 Functional Description The LM96194 provides 9 channels of voltage monitoring, 4 remote thermal diode monitors, an internal/local ambient temperature sensor, a PROCHOT monitor, 4 fan tachometers, 8 GPIOs, THERMTRIP monitor for masking error events, 1 sets of 7 VID inputs, an ALERT output and all the associated limit registers on a single chip, and communicates to the rest of the baseboard over the System Management Bus (SMBus). The LM96194 also provides 2 PWM outputs and associated fan control logic for controlling the speed of system fans. There are two sets of fan control logic, a lookup table and a PI (proportional/integral) loop controller. The lookup table and PI controller are interactive, such that the fans run at the fastest required speed. Upon a temperature or fan tach error event, the PWM outputs may be programmed such that they automatically boost to 100% duty cycle. A timer is included that sets the minimum time that the fans are in the boost condition when activated by a fan tach error. The LM96194 incorporates National Semiconductor's TruTherm technology for precision "Remote Diode" readings of processors on 90nm process geometry or smaller. Readings from the external thermal diodes and the internal temperature sensor are made available as an 9-bit two'scomplement digital value with the LSb representing 0.5C. Filtered temperature readings are available as a 12-bit two'scomplement digital value with the LSb representing 0.0625 C. All of the analog inputs include internal scaling resistors, exept for AD_IN1, AD_IN2, AD_IN3 and AD_IN8. External scaling resistors are required for measuring 12V. The inputs are converted to 8-bit digital values such that a nominal voltage appears at 3/4 scale for positive voltages and 1/4 scale for negative voltages. The analog inputs are intended to be connected to both baseboard resident VRDs and to standard voltage rails supplied by a SSI compliant power supply. The LM96194 has logic that ties a set of dynamically moving VID inputs to their associated Vccp analog input for real time window comparison fault determination. Voltage mapping for VRD10, VRD10 extended and VRD11are supported by the LM96194. When VRD10 mode is selected GPI8 and GPI9 can be used to detect external error flags whose state is reflected in the status registers. Error events are captured in two sets of mirrored status registers (BMC Error Status Registers and Host Status Registers) allowing two controllers access to the status information without any interference. The LM96194's ALERT output supports interrupt mode or comparator mode of operation. The comparator mode is only functional for thermal monitoring. The LM96194 provides a number of internal registers, which are detailed in the register section of this document. 12.2 A/D INHERENT AVERAGING The A/D architecture filters the input signal. During one conversion many samples are taken of the input voltage and these samples are effectively averaged to give the final result. The output of the A/D is the average value of the signal during the sampling interval. For a voltage measurement, the samples are accumulated for 1.5 ms. For a temperature measurement, the samples are accumulated for 8.4 ms. 12.3 TEMPERATURE MONITORING The LM96194 remote diode target is the embedded thermal diode found in a Xeon class processor in 90nm processes but can also work with any Intel CorporationTM based processor in 90nm or 65nm. The LM96194 has an advanced thermal diode input stage using National's TruTherm technology that reduces the spread in ideality found in sub-micron geometry thermal diodes. Internal analog filtering has been included in the thermal diode input stage thus minimizing the need for external thermal diode filter capacitors. In addition a digital filter has been included for the thermal diode temperature readings. In some cases instead of using the embedded thermal diode, found on the Xeon processor, a diode connected 2N3904 transistor type can also be used. An example of this would be a MMBT3904 with its collector and base tied to the thermal diode REMOTE+ pin and the emitter tied to the thermal diode REMOTE- pin. Since the MMBT3904 is a surface mount device and has very small thermal mass, it measures the board temperature where it is mounted. The ideality and series resistance varies for different diodes. Therefore the LM96194 has register support to allow calibration selection between a 2N3904 or a Xeon processor. The LM96194 is optimized for typical Intel processors on 90nm or 65nm process or 2N3904 transistor. Other transistor types may be used but may have additional error that can be corrected for by programming the appropriate Zone Adjustment Offset register. The LM96194 acquires temperature data from four different sources: 4 external diodes (embedded in a processor or discrete) 1 internal diode (internal to the LM96194) 1 analog temperature sensors, such as the LM60, that are connected to the AD_15 pin a temperature value can be externally written into an LM96194 register from the SMBus. All of these values, although not necessarily simultaneously, can be used to control fans, compared against limits, etc. The temperature value registers are located at addresses 06h-09h, 50h-55h and 10h-23h. The temperature sources are referred to as "zones" for convenience: 12.1 MONITORING CYCLE TIME When the LM96194 is powered up, it cycles through each temperature measurement followed by the analog voltages in sequence, and it continuously loops through the sequence. The total monitoring cycle time is not less than 100 ms, as this is the time period that most external micro-controllers require to read the register values. Each measured value is compared to values stored in the limit registers. When the measured value violates the programmed limit, a corresponding status bit in the B_Error and H_Error Status Registers is set. www.national.com 10 Temperature Description Zone 1a Processor 1 remote diode 1 (REMOTE1a+, REMOTE1-) Zone 1b Processor 1 remote diode 2 (REMOTE1b+, REMOTE1-) * MSB LSB 1100 1001 1000 0000 C9 80h -127.5C 1000 0001 1000 0000 81 80h 12-bit two's complement word with the LSb equal to 0.0625C; this applies to extended filtered temperature measurement extended resolution value registers MMBT3904 remote diode 1 (REMOTE2a+, REMOTE2-) Zone 2b MMBT2904 remote diode 2 (REMOTE2b+, REMOTE2-) Temperature Zone 3 Internal LM96194 on-chip sensor; also accepts writes via SMBus Zone 4 External digital temperature value from SMBus write to register 53h or external LM60 analog sensor connected to AD_IN8 Binary Hex +125C 0111 1101 7Dh +25C 0001 1001 19h +1.0C 0000 0001 01h 0C 0000 0000 00h -1.0C 1111 1111 FFh -25C 1110 0111 E7h -55C 1100 1001 C9h -127C 1000 0001 81h Binary Hex MSB LSB +125.5C 0111 1101 1000 0000 7D 80h +25.5C 0001 1001 1000 0000 19 80h +0.5C 0000 0000 1000 0000 00 80h 0C 0000 0000 0000 0000 00 00h -0.5C 1111 1111 1000 0000 FF 80h -25.5C 1110 0111 1000 0000 E7 80h +125.0625C 0111 1101 0001 0000 7D 10h +25.0625C 0001 1001 0001 0000 19 10h +1.0625C 0000 0001 0001 0000 01 10h 0C 0000 0000 0000 0000 00 00h -0.0625C 1111 1111 1111 0000 FF F0h -25.0625C 1110 0111 1111 0000 E7 F0h -55.0625C 1100 1001 1111 0000 C9 F0h -127.0625C 1000 0000 1111 0000 80 F0h 12.4 EVENT ERRORS FOR FAN BOOST Temperature boost error and tachometer error events can cause the fan control PWM output(s) to go to full on. A boost temperature error event will cause both PWM outputs to go to full on, while a tachometer event can be either bound to PWM1 or PWM2. A fan boost temperature event occurs if any of the four temperature zones exceeds the temperature Fan Boost Limit for that zone. Once a temperature has exceed the boost limit, it must drop to a value equal to the boost limit minus the boost hysteresis before the boost condition is deactivated. The default setting for Zones 1 and 2 is 60C and for Zones 3 and 4 it is 35C. The tachometer error boost function is enabled via the Tachometer Fan Boost Control register. Depending on the setting of the tachometer to PWM binding bits one or both of the PWM outputs will go to 100% duty cycle upon the detection of an unmasked Fan Tachometer Error Event. A Fan Tachometer Error event occurs when a tachometer reading exceeds the value set in it's FAN Tach Limit register. Once the error event ends the PWM output(s) will remain at 100% duty cycled for a time interval, Tach Boost Timeout, as programmed in the Tachometer Fan Boost Control register. If the tachometer error event returns during the middle of the timout interval the Tach Boost Timeout interval will be reset and restart once the error event ends. 9-bit two's complement word with the LSb equal to 0.5C; this applies to unfiltered temperature measurement extended resolution value registers Temperature Hex LSB 12.3.3 Thermal Diode Fault Status The LM96194 provides for indications of a fault (open or short circuit) with the remote thermal diodes. Before a remote diode conversion is updated, the status of the remote diode is checked for an open or short circuit condition. If such a fault condition occurs, a status bit is set in the status register. A short circuit is defined as the diode pins connected to each other. When an open or short circuit is detected, the corresponding temperature register is set to 80h. Note: A value of 80h has a special meaning in the limit registers. It means that the temperature channel is masked. In addition, temperature readings of 80h indicate thermal diode faults. * Binary MSB Some fan control configuration registers use four bits and have an unsigned binary format, please see the fan control configuration register descriptions for further details on this 4bit format. 12.3.2 Temperature Data Format Most of the temperature data for the LM96194 is represented in three formats: * 8-bit, two's complement byte with the LSb equal to 1.0 C; this applies to temperature measurements as well as any temperature limit registers and some configuration registers. Temperature Hex -55.5C Zone 2a 12.3.1 "Remote Diode" TruTherm Mode The processor "remote thermal diode" is more correctly described as a transistor. The LM93 treated the "remote diode" as a diode thus introducing inaccuracies. These inaccuracies have become more apparent as the geometry of processors is shrinking. The LM96194 can sense the "remote diode" using a new TruTherm technology that treats the remote device as a transistor. The TruTherm Mode is more accurate for processors on 90nm and smaller geometry. The LM96194 still supports the old diode method and is callibrated for 2N3904 transistor type. Binary 12.5 VOLTAGE MONITORING The LM96194 contains inputs for monitoring voltages. Scaling is such that the correct value refers to approximately 3/4 11 www.national.com LM96194 Zone LM96194 scale or 192 decimal on all inputs, except for the 12V. Scaling is accomplished by using internal resistor dividers, except for the 12V. The typical input resistance of these inputs is 200 k ohms. Input voltages are converted by an 8-bit DeltaSigma () A/D. The Delta-Sigma A/D architecture provides inherent filtering and spike smoothing of the analog input signal. The 12V inputs must be scaled externally. A full scale reading is achieved when 1.236V is applied to these inputs. For optimum performance the +12V should be scaled to provide a nominal 3/4 full scale reading, while the -12V should be scaled to provide a nominal 1/4 scale reading. The thevenin resistance at the pin should be kept between 1 k and 7 k. The -12V monitoring is particularly challenging. It is required that an external offset voltage and external resistors be used to bring the -12V rail into the positive input voltage region of the A/D input. It is suggested that the supply rail for the LM96194 device be used as the offset voltage. This voltage is usually derived from the P/S 5V stand-by voltage rail via a 1% accurate linear regulator. In this fashion we can always assume that the offset voltage is present when the -12V rail is present as the system cannot be turned on without the 3.3V stand-by voltage being present. Voltage vs Register Reading Pin Normal Use Nominal Voltage Register Reading at Nominal Voltage Register Reading Maximum at Voltage Maximum Voltage Minimum Voltage Register Reading at Minimum Voltage Absolute Maximum Range AD_IN1 +12V1 0.927V C0h 1.236V FFh 0V 00h -0.3V to (VDD + 0.05V) AD_IN2 +12V2 0.927V C0h 1.236V FFh 0V 00h -0.3V to (VDD + 0.05V) AD_IN3 +12V3 0.927V C0h 1.236V FFh 0V 00h -0.3V to (VDD + 0.05V) AD_IN4 Vccp1 1.20V C0h 1.60V FFh 0V 00h -0.3V to +6.0V AD_IN5 +3.3V 3.30V C0h 4.40V FFh 0V 00h -0.3V to +6.0V AD_IN6 Mem_Vtt 0.984V C0h 1.312V FFh 0V 00h -0.3V to +6.0V AD_IN7 Gbit_Core 0.984V C0h 1.312V FFh 0V 00h -0.3V to +6.0V AD_IN8 -12V 0.309V 40h 1.236V FFh 0V 00h -0.3V to (VDD + 0.05V) AD_IN9 +3.3V S/B 3.3V C0h 3.6V D1h 3.0V AEh -0.3V to +6.0V The nominal voltages listed in this table are only typical values. Voltage rails with different nominal voltages can be monitored, but the register reading at the nominal value is no longer C0h. AD_IN9 is also the power pin of the LM96194, therefore special limitations apply to this AD input. The guaranteed opera- www.national.com tional voltage range for the LM96194 is 3.0V to 3.6V, therefore the voltage input to this pin is limited by this restriction. Care should also be taken not to apply more than 6V to this pin to prevent catastrophic damage. 12 (4) Using standard 1% resistor values for R1 of 5.76 k and R2 of 1.4 k yields an R1 to R2 ratio of 4.1143. The input voltage VIN can be calculated using the value register reading (VR) using this equation: (5) 20194408 The table below summarizes the theoretical voltage values for value register readings near -12V. FIGURE 2. Required External Scaling Resistors for +12V Power Input Value Register VIN % from -12V 15 -13.2068 -10.0563 16 -13.1821 -9.8505 (1) 17 -13.1574 -9.6448 It is recommended that the equivalent thevenin resistance of the divider be between 1k and 7k to minimize errors caused by leakage currents at extreme temperatures. The best values for the resistors are: R1=13.7 k and R2=1.15 k. This yields a ratio of 11.94498, which has a +0.27% deviation from the theoretical. It is also recommended that the resistors have 1% tolerance or better. Each LSB in the voltage value registers has a weight of 12V / 192 = 62.5 mV. To calculate the actual voltage of the +12V power input, use the following equation: 18 -13.1327 -9.4390 19 -13.1080 -9.2332 20 -13.0833 -9.0275 21 -13.0586 -8.8217 22 -13.0339 -8.6159 23 -13.0092 -8.4101 24 -12.9845 -8.2044 25 -12.9598 -7.9986 26 -12.9351 -7.7928 27 -12.9104 -7.5871 28 -12.8858 -7.3813 29 -12.8611 -7.1755 30 -12.8364 -6.9698 31 -12.8117 -6.7640 32 -12.7870 -6.5582 33 -12.7623 -6.3524 34 -12.7376 -6.1467 35 -12.7129 -5.9409 36 -12.6882 -5.7351 37 -12.6635 -5.5294 38 -12.6388 -5.3236 39 -12.6141 -5.1178 40 -12.5894 -4.9121 41 -12.5648 -4.7063 42 -12.5401 -4.5005 43 -12.5154 -4.2947 44 -12.4907 -4.0890 45 -12.4660 -3.8832 46 -12.4413 -3.6774 47 -12.4166 -3.4717 48 -12.3919 -3.2659 49 -12.3672 -3.0601 50 -12.3425 -2.8544 51 -12.3178 -2.6486 52 -12.2931 -2.4428 53 -12.2684 -2.2370 To calculate the required ratio of R1 to R2 use this equation: VIN = (8-bit value register code) x (62.5 mV) (2) 12.7 RECOMMENDED EXTERNAL SCALING CIRCUIT FOR -12V POWER INPUT The -12V input requires external resistors to level shift the nominal input voltage of -12V to +0.309V. 20194410 FIGURE 3. Required External Level Shifting Resistors for -12V Power Input The +3.3V standby voltage is used as a reference for the level shifting. Therefore, the tolerance of this voltage directly effects the accuracy of the -12V reading. To minimize ratio errors, a tolerance of better than 1% should be used. It is recommended that the equivalent thevenin resistance of the divider is between 1k and 7k to minimize errors caused by leakage currents at extreme temperatures. To calculate the ratio of R1 to R2 use this equation: (3) where VIN is the nominal input voltage of -12V, VREF is the reference voltage of +3.3V and AD_IN is the voltage required at the AD input for a 1/4 scale reading or 0.309V. Therefore, for this case: 13 www.national.com LM96194 12.6 RECOMMENDED EXTERNAL SCALING RESISTORS FOR +12V POWER RAILS The +12V inputs require external scaling resistors. The resistors need to scale 12V down to 0.927V. LM96194 Value Register VIN % from -12V Value Register VIN % from -12V 54 -12.2438 -2.0313 104 -11.0091 8.2572 55 -12.2191 -1.8255 105 -10.9844 8.4630 56 -12.1944 -1.6197 106 -10.9597 8.6688 57 -12.1697 -1.4140 107 -10.9351 8.8745 58 -12.1450 -1.2082 108 -10.9104 9.0803 59 -12.1203 -1.0024 109 -10.8857 9.2861 60 -12.0956 -0.7967 110 -10.8610 9.4919 61 -12.0709 -0.5909 111 -10.8363 9.6976 62 -12.0462 -0.3851 112 -10.8116 9.9034 63 -12.0215 -0.1793 113 -10.7869 10.1092 64 -11.9968 0.0264 65 -11.9721 0.2322 66 -11.9474 0.4380 67 -11.9228 0.6437 68 -11.8981 0.8495 69 -11.8734 1.0553 70 -11.8487 1.2610 71 -11.8240 1.4668 72 -11.7993 1.6726 73 -11.7746 1.8784 74 -11.7499 2.0841 75 -11.7252 2.2899 76 -11.7005 2.4957 77 -11.6758 2.7014 78 -11.6511 2.9072 79 -11.6264 3.1130 80 -11.6018 3.3188 81 -11.5771 3.5245 82 -11.5524 3.7303 83 -11.5277 3.9361 84 -11.5030 4.1418 85 -11.4783 4.3476 86 -11.4536 4.5534 87 -11.4289 4.7591 88 -11.4042 4.9649 89 -11.3795 5.1707 90 -11.3548 5.3765 91 -11.3301 5.5822 92 -11.3054 5.7880 93 -11.2807 5.9938 94 -11.2561 6.1995 95 -11.2314 6.4053 96 -11.2067 6.6111 97 -11.1820 6.8168 98 -11.1573 7.0226 99 -11.1326 7.2284 100 -11.1079 7.4342 101 -11.0832 7.6399 102 -11.0585 7.8457 103 -11.0338 8.0515 www.national.com 12.8 ADDING EXTERNAL SCALING RESISTORS TO OTHER ANALOG INPUTS All analog inputs, except AD_IN1 through AD_IN3 and AD_IN8, include internal resistor dividers. Further scaling of AD_IN4 through AD_IN7 inputs with external scaling resistors is possible if the errors due to the internal dividers are accounted. The internal resistors, RIN1 + RIN2 shown in Figure 4, will present to the external divider a minimum resistive load of 140 k. 20194421 FIGURE 4. AD_IN4 - AD_IN7 External Resistor Divider 12.9 DYNAMIC Vccp MONITORING USING VID The AD_IN4 (CPU Vccp) input is dynamically monitored using the VIDx inputs to determine the limits. The dynamic comparisons operate independently of the static comparisons which use the statically programmed limits. The LM96194 supports 3 different specifications for the Voltage Regulator (VRM or VRD) used on motherboards with Intel CPUs with four different VID Modes of operation. The Voltage Regulator Specifications supported are the VRD10/VRM10, VRD10.2 Extended and VRD11/VRM11, and in this document they will be referred to as the VRD10, VRD10.2 and VRD11 specifications, respectively. According to the VRD 10 specification when a VID signal is ramping to a new value, it steps by one LSB at a time, and one step occurs every 5 s. In worse case, up to 20 steps may occur at once over 100 s. The Vccp voltage from the VRD has to settle to the new value within 50 s of the last VID change. The LM96194 expects that the VID changes will not occur more frequently than every 5 s in the VRD10 mode. Similarly the LM96194 can support the timing requirements of the VRD10.2 and VRD11 specifications. The VID signals can be changed by the processor under program control, by internal thermal events or by external control, like force PROCHOT. The reference voltages selected by each value of the VID code can be found in the different VRM/VRD specifications. 14 Temp AD_ IN8 0.309 (1/4 scale) Full Scale (code 256) V 254.5 mV LM60 code V /LSb deg /LSb 1.2360 1.2288 AD_IN8 Reading Signed Decimal Signed Hex 40 0.6740 12 C 45 0.7053 18 12 50 0.7365 25 19 55 0.7678 31 1F 60 0.7990 37 25 65 0.8303 44 2C 70 0.8615 50 32 75 0.8928 57 39 80 0.9240 63 3F 85 0.9553 70 46 90 0.9865 76 4C 95 1.0178 83 53 100 1.0490 89 59 105 1.0803 96 60 110 1.1115 102 66 115 1.1428 109 6D 120 1.1740 115 73 125 1.2053 122 7A 130 1.2365 127 7F The following table lists the expected ideal digital values when using the LM50. Temp 12.10 MONITORING ANALOG TEMPERATURE SENSORS The AD_IN8 reading can be routed to the fan control logic to facilitate the use of external temperature sensors such as the LM60. When these inputs are used for temperature sensing the digital output returned is in signed format, that is the MSb is inverted. The following table lists critical parameters necessary for converting the binary data to temperature. Input V NOM LM60 Ideal Vout LM50 deg /LSb 4.8 0.7725 0.4828 LM50 Ideal Vout AD_IN8 Reading Signed Decimal Signed Hex 0 0.5 -24.44 E8 25 0.7500 27 1B 30 0.8000 38 26 35 0.8500 48 30 40 0.9000 58 3A 45 0.9500 69 45 50 1.0000 79 4F 55 1.0500 89 59 60 1.1000 100 64 65 1.1500 110 6E 70 1.2000 121 79 The following table lists the equations to use for converting the AD_IN8 Digital Value (DV) to a temperature value. 75 1.2500 127 7F 80 1.3000 127 7F Input 85 1.3500 127 7F 90 1.4000 127 7F 95 1.4500 127 7F 100 1.5000 127 7F 105 1.5500 127 7F 110 1.6000 127 7F 115 1.6500 127 7F D8 120 1.7000 127 7F F8 125 1.7500 127 7F 130 1.8000 127 7F AD_IN8 LM60 Equation LM50 Equation (DV + 40.18) x 0.7725 (DV + 24.44) x 0.4828 The following table lists the ideal values generated when using the LM60 at different temperatures. Temp 0 25 LM60 Ideal Vout 0.424 0.5803 AD_IN8 Reading Signed Decimal -40.18 -8 Signed Hex 30 0.6115 -1 FF 35 0.6428 5 5 15 www.national.com LM96194 Transient VID values caused by line-to-line skew are ignored by the LM96194. See the VRM/VRD specifications for the worst case line-to-line skew. The LM96194 averages the VID values over a sampling window to determine the average voltage that the VID input was indicating during the sampling window. At the completion of a voltage conversion cycle the LM96194 performs limit comparisons based on average VID values and not instantaneous values. The upper limit is determined by adding the upper limit offset to the average voltage indicated by VID. The lower limit is determined by subtracting the lower limit offset from average voltage indicated by VID. If the AD_IN4 voltage falls outside the upper and lower limits, an error event is generated. Dynamic and static comparisons are performed once every 100 ms. The averaging time interval is 1.5 ms. If at any time during the Vccp sampling window, the VID code indicates that the VRD/VRM should turn off its output, the dynamic Vccp checking is disabled for that sample. The comparison accuracy is 25 mV, therefore the comparison limits must be set to include this error. Since the Vccp voltage may be in the process of settling to a new value (due to a VID change), this settling should be taken into account when setting the upper and lower limit offsets. The LM96194 has a limitation on the upper limit voltage for dynamic Vccp checking. The upper limit cannot exceed 1.5875V. If the sum of the voltage indicated by VID and the upper offset voltage exceed 1.5875, the upper limit checking is disabled. Pin 17 has a dual purpose. When VRD10 mode is selected they can be used as general purpose inputs whose state is reflected the BMC and Host Error Status registers. In the other VRD modes they are used as a VID6 input. LM96194 12.11 PROCHOT BACKGROUND INFORMATION PROCHOT is an output from a processor that indicates that the processor has reached a predetermined temperature trip point. At this trip point the processor can be programmed to lower its internal operating frequency and/or lower its supply voltage by changing the value of the 6 bit VID that it supplies to the VRD. The final VID setting and the rate at which it transitions to the new VID is programmable within the processor. If PROCHOT is 100% throttled, it does not mean that the CPU is not executing, but it may mean that the CPU is about to encounter a thermal trip if the processor temperature continues to rise. PROCHOT is also an input to some processors so that an external controller can force a thermal throttle based on external events. PROCHOT is no longer asserted by the processor when the temperature drops below the predefined thermal trip point. Oscillation around the trip point is avoided by the processor by requiring that the temperature be above/below the trip point for a predetermined period of time. A counter inside the processor is used to track this time and it has to be incremented to a max count for an above temperature trip and decremented to zero when below the trip temperature setting, to remove the trip. The minimum time for PROCHOT assertion is time dependant on the FSB frequency. The minimum time that the processor asserts PROCHOT is estimated to be 187 s. 8-Bit Result Exactly 0% 1 Between 0% and 0.39% 2 Between 0.39% and 0.78% www.national.com ... n Between (n-1)/256 and n/256 ... ... 253 Between 98.4% and 98.8% 254 Between 98.8% and 99.2% 255 Greater than 99.2% Status Description 100% Throttle Comparison Formula PROCHOT was never deasserted during monitoring interval. Greater than or equal to 75% 193 measured value and and less than 100% not 100% Greater than or equal to 50% 129 measured value < 193 and less than 75% Greater than or equal to 25% 65 measured value < 129 and less than 50% Greater than or equal to 12.5% and less than 25% 33 measured value < 65 Greater than 0% and less than 12.5% 0 < measured value < 33 Greater than 0% 0 < measured value Greater than user limit user limit < measured value These status bits are reflected in the PROCHOT Error Status Register. In S3 and S4/5 sleep states, the PROCHOT Monitoring function does not run. VRD_Hot is disabled from activating PROCHOT pin in S3 and S4/5. The Current PROCHOT registers are reset to 00h and the Average PROCHOT registers hold their current state. Once the sleep state changes back to S0, the monitoring function is restarted. After the first PROCHOT measurement has been made, the measurement is written directly into the Current and Average PROCHOT registers without performing any averaging. Averaging returns to normal on the second measurement. 12.13 PROCHOT OUTPUT CONTROL In some cases, it is necessary for the LM96194 to drive the PROCHOT output low. There are several conditions that cause this to happen. Whenever one of the VRD_HOT input is asserted, the PROCHOT pin is asserted by the LM96194. The response time is less than 10 s. When the VRD_HOT input is de-asserted, the PROCHOT pin is no longer asserted by the LM96194. This response is disabled in sleep states 3 and 4/5 and can be disabled through the PROCHOT Control register. Software can manually program the LM96194 to drive a PWM type signal onto PROCHOT. This is done via the PROCHOT Override register. See the description of this register for more details. Percentage Thottled 0 ... To achieve the second goal, the LM96194 has several comparators that compare the measured percentage reading against several fixed and 1 variable value. The variable value is user programmable. The result of these comparisons generates several error status bits described in the following table: 12.12 PROCHOT MONITORING PROCHOT monitoring is meant to achieve two goals. One goal is to measure the percentage of time that PROCHOT is asserted over a programmable time period. The result of this measurement can be read from an 8-bit register where one LSB equals 1/256th of the PROCHOT Time Interval (0.39%). The second goal is to have a status register that indicates, as a coarse percentage, the amount of time a processor has been throttled. This second goal is required in order to communicate information over the NIC using ASF, i.e. status can be sent, not values. To achieve the first goal, the PROCHOT input is monitored over a period of time as defined by the PROCHOT Time Interval Register. At the end of each time period, the 8-bit measurement is transferred to the Current PROCHOT register. Also at the end of each measurement period, the Current PROCHOT register value is moved to the Average PROCHOT register by adding the new value to the old value and dividing the result by 2. Note that the value that is averaged into the Average PROCHOT register is not the new measurement but rather the previous measurement. If the SMBus writes to the Current PROCHOT register, the capture cycle restarts. Also note, that a strict average of two 8-bit values may result in Average PROCHOT reflecting a value that is one LSB lower than the Current PROCHOT in steady state. It should be noted that the 8-bit result has a positive bias of one half of an LSB. This is necessary because a value of 00h represents that PROCHOT was not asserted at all during the sampling window. Any amount of throttling results in a reading of 01h. The following table demonstrates the mapping for the 8-bit result: 8-Bit Result Percentage Thottled 16 12.15 SMART FAN SPEED MEASUREMENT If a fan's speed is varied using PWM drive of either of the fans power pins, the tachometer output of the fan is corrupted. The LM96194 includes smart tachometer circuitry that allows an accurate tachometer reading to be achieved despite the signal corruption. In smart tach mode all four signals are measured within 4 seconds. A smart tach capture cycle works according to the following steps: 1. Both PWM outputs are synchronized such that they activate simultaneously. 2. Both PWM output active times are extended for up to 50 ms. 3. The number of tach signal periods during the 50 ms interval are tracked: a) If less than 1 period is sensed during the 50 ms extension the result returned is 3FFh. b) After one period occurs the count for that period is memorized. c) If during the 50 ms interval 2 periods do not occur, the tach value reported is the 1 period count multiplied by 2. d) If 2 periods do occur, the 2 period count is loaded into the value register and the 50 ms PWM extension is terminated. 13.2 RESET INPUT/OUTPUT This pin acts as an active low reset output when power is applied to the LM96194. It is asserted when the LM96194 first sees a voltage that exceeds the internal POR level on its +3.3V S/B VDD input. The internal registers of the LM96194 are reset to their defaults when power is applied. After this reset has completed, the RESET pin becomes an input. When an external device asserts RESET, the LM96194 clears the LOCK bit in the LM96194 Configuration register. This feature allows critical registers to be locked and provides a controlled mechanism to unlock them. If the LM96194 RESET is not used it must be tied high through an external resistive pull-up to prevent LM96194 malfunction. Within 10 sec of asserting RESET externally, the Sleep State Control register shall be automatically set to S4/5. This causes several error events to be masked according to the S4/5 masking definitions. Refer to the register descriptions for more information. RESET may not be detected if it is asserted for less than 4 sec. The lowest two bits in each of the Fan Tach value registers are reserved. The smart tach feature takes advantage of these bits. In normal tach mode, these bits return 00. In smart tach mode the two bits determine the accuracy level of the reading. 11 is most accurate (2 periods used) and 10 is the least accurate (1 period used). If less than 1 period occurred during the measurement cycle, the lower two bits are set to 10. In smart fan tach mode, the TACH_EDGE field is honored in the LM96194 Status/Control register. If only one edge type is active, the measurement always uses that edge type (rising or falling). If both are active, the measurement uses whichever edge type occurs first. Typically the minimum RPM captured by smart fan tach mode is 900 RPM for a fan that produces two pulses per revolution at about 50% duty cycle. 13.3 PWM1 AND PWM2 OUTPUTS The PWM outputs are used to control the speed of fans. The duty cycle of each output is automatically controlled by the temperature of one or more temperature zones. They are also influenced by various other inputs and registers. See Section 15.10 FAN CONTROL for further information on the behavior of the PWM outputs. 13.4 VRD_HOT INPUT These inputs monitor the thermal sensor associated with each processor VRD on a baseboard. When one of the inputs is activated, it indicates that the VRD has exceeded a predetermined temperature threshold. The LM96194 responds by gradually increasing the duty cycle of any PWM outputs that are bound to the corresponding processor and setting the appropriate error status bits. The PROCHOT signal is also asserted. See the Section 15.10 FAN CONTROL and the Section 12.13 PROCHOT OUTPUT CONTROL for more information. 13.0 Inputs/Outputs Besides all the pins associated with sensor inputs the LM96194 has several pins that are assigned for other specific functions. 13.1 ALERT OUTPUT The ALERT output is an active-low open drain output signal. The ALERT output is used to signal a micro-controller that 17 www.national.com LM96194 one or more sensors have crossed their corresponding limit thresholds. This is generally not a fatal event unless the micro-controller decides it to be. If enabled, the ALERT output is asserted whenever any bit in any BMC Error Status register is set (with the exception of the fixed PROCHOT threshold bits). By definition, when ALERT is enabled, it always matches the inverse of the BMC_ERR bit in the LM96194 Status/Control register. When the ALERT output is disabled, an alert event can still be determined by reading the state of the BMC_ERR bit. The ALERT functions like an interrupt. The LM96194 does not support the SMBus ARA (Alert Response Address) protocol. ALERT is only de-asserted when there are no error status bits set in any BMC Error Status registers. Alternatively, software can disable the ALERT output to cause it to de-assert. The ALERT output re-asserts once enabled if any BMC Error Status register bits are still set. The ALERT output also functions in comparator mode for thermal events, that is the ALERT output will be asserted for unmasked thermal error events and will de-assert immediately when the error event ceases. The operation of the ALERT output is controlled by the LM96194 Configuration register. Further information on how the ALERT output behaves can be found in Section 15.7 MASKING, ERROR STATUS AND ALERT. 12.14 FAN SPEED MEASUREMENT The fan tach circuitry measures the period of the fan pulses by enabling a counter for two periods of the fan tach signal. The accumulated count is proportional to the fan tach period and inversely proportional to the fan speed. All four fan tach signals are measured within 1 second. Fans in general do not over-speed if run from the correct voltage, so the failure condition of interest is under speed due to electrical or mechanical failure. For this reason only lowspeed limits are programmed into the limit registers for the fans. It should be noted that, since fan period rather than speed is being measured, a fan tach error event occurs when the measurement exceeds the limit value. LM96194 includes on chip low-pass filtering of the SMBCLK and SMBDAT signals to make it more noise immune. Minimize noise coupling by keeping digital traces out of switching baseboard areas as well as ensuring that digital lines containing high speed data communications cross at right angles to the SMBDAT and SMBCLK lines. 13.5 GPIO and GPI PINS The LM96194 has 8 GPIO pins than can act as either as general purpose inputs or outputs and 1 GPI pin that can act as general purpose input. Each can be configured and controlled independently. When acting as an input the pin can be masked to prevent it from setting a corresponding bit in the GPI Error status registers. Some of these pins can also function as tachometer or VID inputs. 14.3 GENERAL SMBus TIMING The SMBus 2.0 specification defines specific conditions for different types of read and write operations but in general the SMBus protocol operates as follows: The master initiates data transfer by establishing a START condition, defined as a high to low transition on the serial data line SMBDAT while the serial clock line SMBCLK remains high. This indicates that a data stream follows. All slave peripherals connected to the serial bus respond to the START condition, and shift in the next 8 bits. This consists of a 7-bit slave address (MSB first) plus a R/W bit, which determines the direction of the data transfer, i.e. whether data is written to or read from the slave device (0 = write, 1 = read). The peripheral whose address corresponds to the transmitted address responds by pulling the data line low during the low period before the ninth clock pulse, known as the Acknowledge Bit, and holding it low during the high period of this clock pulse. All other devices on the bus now remain idle while the selected device waits for data to be read from or written to it. If the R/W bit is a 0 then the master writes to the slave device. If the R/W bit is a 1 the master reads from the slave device. Data is sent over the serial bus in sequences of 9 clock pulses, 8 bits of data followed by an Acknowledge bit. Data transitions on the data line must occur during the low period of the clock signal and remain stable during the high period, as a low to high transition when the clock is high may be interpreted as a STOP signal. If the operation is a write operation, the first data byte after the slave address is a command byte. This tells the slave device what to expect next. It may be an instruction, such as telling the slave device to expect a block write, or it may simply be a register address that tells the slave where subsequent data is to be written. Since data can flow in only one direction as defined by the R/ W bit, it is not possible to send a command to a slave device during a read operation. Before doing a read operation, it is necessary to do a write operation to tell the slave what sort of read operation to expect and/or the address from which data is to be read. When all data bytes have been read or written, stop conditions are established. In WRITE mode, the master will allow the data line to go high during the 10th clock pulse to assert a STOP condition. In READ mode, the slave drives the data not the master. For the bit in question, the slave is looking for an acknowledge and the master doesn't drive low. This is known as `No Acknowledge'. The master then takes the data line low during the low period before the 10th clock pulse, then high during the 10th clock pulse to assert a STOP condition. Note, a repeated START may be given only between a write and read operation that are in succession. 13.6 FAN TACH INPUTS The fan inputs are Schmitt-Trigger digital inputs. SchmittTrigger input circuitry is included to accommodate slow rise and fall times typical of fan tachometer outputs. The maximum input signal range is 0V to +6.0V, even when VDD is less than 5V. In the event that these inputs are supplied from fan outputs, which exceed 0V to +6.0V, either resistive attenuation of the fan signal or diode clamping must be included to keep inputs within an acceptable range, thereby preventing damage to the LM96194. Hot plugging fans can involve spikes on the Tach signals of up to 12V so diode protection or other circuitry is required. For "Hot Plug" fans, external clamp diodes may be required for signal conditioning. 14.0 SMBus Interface The SMBus is used to communicate with the LM96194. LM96194 SMBus interface lines are designed to be tolerant to 5V signalling. Necessary pull-ups are located on the baseboard. Care should be taken to ensure that only one pull-up is used for each SMBus signal. The SMBus interface obeys the SMBus 2.0 protocols and signaling levels. The SMBus interface of the LM96194 does not load down the SMBus if no power is applied to the LM96194. This allows a module containing the LM96194 to be powered down and replaced, if necessary. 14.1 SMBus ADDRESSING Each time the LM96194 is powered up, it latches the assigned SMBus slave address (determined by ADDR_SEL) during the first valid SMBus transaction in which the first five bits of the targeted slave address match those of the LM96194 slave address. Once the address has been latched, the LM96194 continues to use that address for all future transactions until power is lost. The address select input detects three different voltage levels and allows for up to 3 devices to exist in a system. The address assignment is as follows: Address Select Pin (ADDR_SEL) Slave Address Assignment High 01011 01 VDD/2 01011 10 Low 01011 00 14.2 DIGITAL NOISE EFFECT ON SMBus COMMUNICATION Noise coupling into the digital lines (greater than 150mV), overshoot greater than VDD and undershoot less than GND, may prevent successful SMBus communication with the LM96194. SMBus No Acknowledge (NACK) is the most common symptom, causing unnecessary traffic on the bus. Although, the SMBus maximum frequency of communication is rather low (100 kHz max), care still needs to be taken to ensure proper termination within a system with multiple parts on the bus and long printed circuit board traces. The LM96194 www.national.com 14.4 SMBus ERROR SAFETY FEATURES To provide a more robust SMBus interface, the LM96194 incorporates a timeout feature for both SMBCLK and SMBDAT. If either signal is low for a long period of time (see SMBus AC specs), the LM96194 SMBus state machine reverts to the idle state and waits for a START signal. Large block transfers of all zeros should be avoided if the SMBCLK is operating at a very low frequency to avoid accidental time18 Write Byte -- Write Word -- SMBus Write Block -- I2C Block Write -- Read Byte -- Read Word -- SMBus Read Block SMBus Block-Write Block-Read Process Call -- I2C Block Read In addition to these transactions the LM96194 supports a few extra items and also has some behavior that must be defined beyond the SMBus 2.0 specification. No other SMBus 2.0 transactions are supported (PEC, ARA etc.). The SMBus specification defines several protocols for different types of read and write operations. The ones used in the LM96194 are discussed below. The following abbreviations are used in the diagrams: S -- START P -- STOP R -- READ W -- WRITE A -- ACKNOWLEDGE /A -- NO ACKNOWLEDGE 14.5 SERIAL INTERFACE PROTOCOLS The LM96194 contains volatile registers, the registers occupy address locations from 00h to EFh. Data can be read and written as a single byte, a word, or as a block of several bytes. The LM96194 supports the following SMBus/I2C transactions/protocols: -- Send Byte -- -- 14.5.1 Address Incrementing The established base address does not increment. Repeatedly reading without re-establishing a new base address returns data from the same address each time. I2C read transactions can use this information and skip reestablishing the base address, when only one master is used. One exception to this rule exists when a block write and block read is used to emulate a block write/read process call. This is detailed later, see the Block Write/Read Process Call description. 14.5.2 Block Command Code Summary Block command codes control the block read and write operations of the LM96194 as summarized in the following table: Command Code Name Value Description Block Write Command F0h SMBus Block Write Command Code Block Read Command F1h SMBus Block Write/Read Process Call Fixed Block 0 F2h Fixed Block Read Command Code: address 40h, size 8 bytes Fixed Block 1 F3h Fixed Block Read Command Code: address 48h, size 8 bytes Fixed Block 2 F4h Fixed Block Read Command Code: address 50h, size 6 bytes Fixed Block 3 F5h Fixed Block Read Command Code: address 56h, size 16 bytes Fixed Block 4 F6h Fixed Block Read Command Code: address 67h, size 4 bytes Fixed Block 5 F7h Fixed Block Read Command Code: address 6Eh, size 8 bytes Fixed Block 6 F8h Fixed Block Read Command Code: address 78h, size 12 bytes Fixed Block 7 F9h Fixed Block Read Command Code: address 90h, size 32 bytes Fixed Block 8 FAh Fixed Block Read Command Code: address B4h, size 8 bytes Fixed Block 9 FBh Fixed Block Read Command Code: address C8h, size 8 bytes Fixed Block 10 FCh Fixed Block Read Command Code: address D00h, size 16 bytes Fixed Block 11 FDh Fixed Block Read Command Code: address E5h, size 9 bytes 19 www.national.com LM96194 outs. Pulling the Reset pin low does not reset the SMBus state machine. If the LM96194 SMBDAT pin is low during a system reset, the LM96194's state machine timeouts and resets automatically. If the LM96194's SMBDAT pin is high during a system reset, the first assertion of a start by the master resets the LM96194's interface state machine. Although it is a violation of the SMBus specification, in some cases a START or STOP signal occurs in the middle of a byte transfer instead of coming after an acknowledge bit. If this occurs, only a partial byte was transferred. If a byte was being written, it is aborted and the partial byte is not committed. If a byte was being read from a read-to-clear register, the register is not cleared. LM96194 14.5.3 Write Operations The LM96194 supports the following SMBus write protocols. 14.5.3.1 Write Byte In this operation the master device sends an address byte and one data byte to the slave device, as follows: 1. 2. 3. 4. 5. 6. 7. 8. The master device asserts a START condition. The master sends the 7-bit slave address followed by the write bit (low). The addressed slave device asserts ACK. The master sends a command code (register address). The slave asserts ACK. The master sends the data byte. The slave asserts ACK. The master asserts a STOP condition to end the transaction. 1 2 S Slave Address W 3 4 5 6 7 8 A Register Address A Data Byte A P 14.5.3.2 Write Word In this operation the master device sends an address byte and two data bytes to the slave device, as follows: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. The master device asserts a START condition. The master sends the 7-bit slave address followed by the write bit (low). The addressed slave device asserts ACK. The master sends a command code (register address). The slave asserts ACK. The master sends the low data byte. The slave asserts ACK. The master sends the high data byte. The slave asserts ACK. The master asserts a STOP condition to end the transaction. 1 2 S Slave Address W 3 4 5 6 7 A Register Address A Data Byte A Low 8 9 Data Byte A High 10 P 14.5.3.3 SMBus Write Block to Any Address The start address for a block write is embedded in this transaction. In this operation the master sends a block of data to the slave as follows: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. The master device asserts a START condition. The master sends the 7-bit slave address followed by the write bit (low). The addressed slave device asserts ACK. The master sends a command code that tells the slave device to expect a block write. The LM96194 command code for a block write is F0h. The slave asserts ACK. The master sends a byte that tells the slave device how many data bytes it will send (N). The SMBus specification allows a maximum of 32 data bytes to be sent in a block write. The slave asserts ACK. The master sends data byte 1, the starting address of the block write. The slave asserts ACK after each data byte. The master sends data byte 2. The slave asserts ACK. The master continues to send data bytes and the slave asserts ACK for each byte. The master asserts a STOP condition to end the transaction. www.national.com 20 2 S Slave Address W 3 4 5 6 7 8 9 10 11 ... 12 A Comman d F0h (Block Write) A Byte Count (N) A Data Byte 1 (Start Address) A Data Byte 2 A ... Data Byte N 13 A P Special Notes 1. Any attempts to write to bytes beyond normal address space are acknowledged by the LM96194 but are ignored. 2. Block writes do not wrap from address FFh back to 00h the address remains at FFh. 3. The Byte Count field is ignored by the LM96194. The master device may send more or less bytes and the LM96194 accepts them. 4. The SMBus specification requires that block writes never exceed 32 data bytes. Meeting this requirement means that only 31 actual data bytes can be sent (the register address counts as one byte). The LM96194 does not care if this requirement is met. 14.5.3.4 I2CTM Block Write In this transaction the master sends a block of data to the LM96194 as follows: 1. 2. 3. 4. 5. 6. 7. 8. 9. The master device asserts a START condition. The master sends the 7-bit slave address followed by the write bit (low). The addressed slave device asserts ACK. The master sends the starting address of the block write. The slave asserts ACK after each data byte. The master sends data byte 1. The slave asserts ACK. The master continues to send data bytes and the slave asserts ACK for each byte. The master asserts a STOP condition to end the transaction 1 2 S Slave Address W 3 4 5 6 7 A Register Address A Data Byte 1 A 8 ... Data Byte N 9 A P Special Notes: 1. Any attempts to write to bytes beyond normal address space are acknowledged by the LM96194 but are ignored. 2. Block writes do not wrap from address FFh back to 00h the address remains at FFh. 21 www.national.com LM96194 1 LM96194 14.5.4 Read Operations The LM96194 uses the following SMBus read protocols. 14.5.4.1 Read Byte In the LM96194, the read byte protocol is used to read a single byte of data from a register. In this operation the master device receives a single byte from a slave device, as follows: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. The master device asserts a START condition. The master sends the 7-bit slave address followed by the write bit (low). The addressed slave device asserts ACK. The master sends a register address. The slave asserts an ACK. The master sends a Repeated START. The master sends the slave address followed by the read bit (high). The slave asserts an ACK. The master receives a data byte and asserts a NACK. The master asserts a STOP condition and the transaction ends. 1 2 S Slave Address W 3 4 5 6 7 A Register Address A S Slave Address R 8 9 A Data Byte 10 /A P 14.5.4.2 Read Word In the LM96194, the read word protocol is used to read two bytes of data from a register or two consecutive registers. In this operation the master device reads two bytes from a slave device, as follows: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. The master device asserts a START condition. The master sends the 7-bit slave address followed by the write bit (low). The addressed slave device asserts ACK. The master sends a register address. The slave asserts an ACK. The master sends a Repeated START. The master sends the slave address followed by the read bit (high). The slave asserts an ACK. The master receives the Low data byte and asserts an ACK. The master receives the High data byte and asserts a NACK. The master asserts a STOP condition and the transaction ends. 1 2 S Slave Address W 3 4 5 6 7 A Register Address A S Slave Address R 8 9 A Data Byte Low A 10 11 Data /A Byte High P 14.5.4.3 SMBus Block-Write Block-Read Process Call This transaction is used to read a block of data from the LM96194. Below is the sequence of events that occur in this transaction: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. The master device asserts a START condition. The master sends the 7-bit slave address followed by the write bit (low). The addressed slave device asserts ACK. The master sends a command code that tells the slave device to expect a block read (F1h) and the slave asserts ACK. The master sends the Byte Count for this write which is 2 and the slave asserts ACK. The master sends the Start Register Address for the block read and the slave asserts the ACK. The master sends the Byte Count (1-32) for the block read processes call and the slave asserts ACK. The master asserts a repeat START condition. The master sends the 7-bit slave address followed by the read bit (high). The slave asserts ACK. The master receives a byte count data byte that tells it how many data bytes will received. This field reflects the number of bytes requested by the Byte Count transmitted to the LM96194. The SMBus specification allows a maximum of 32 data bytes to be received in a block read. Then master asserts ACK. www.national.com 22 LM96194 12. 13. 14. 15. 16. The master receives byte 1 and then asserts ACK. The master receives byte 2 and then asserts ACK. The master receives N-3 data bytes, and asserts ACK for each one. The master receives data byte N and asserts a NACK. The master asserts a STOP condition to end the transaction. 1 2 S Slave Address 3 W A 4 5 Block Read Comman d Code (F1h) 11 ... Byte Count (1-20h) (N) A 6 Byte Count (2h) A 12 A Data Byte 1 Start Register Address 7 A 13 A Data Byte 2 A Byte Count (1-20h) (N) A 8 9 S Slave Address 10 14 15 15 16 ... Data Byte N /A P R A ... Special Notes: 1. The LM96194 returns 00h when address locations outside of normal address space are read. 2. Block reads do not wrap around from address FFh to 00h 3. If the master acknowledges more bytes that it requested, the LM96194 continues to supply data until the master does not acknowledge a byte. 4. If the master does not acknowledges a byte to prematurely abort a block read, the LM96194 gets off the bus to allow the master to issue a STOP signal. 14.5.4.4 Simulated SMBus Block-Write Block-Read Process Call Alternatively, if the master cannot support an SMBus Block-Write Block-Read process call, it can be emulated by two transactions (a block write followed by a block read). This should only be done in a single master system, since in a dual master system collisions can occur that corrupt the data and transaction. Below is the sequence of events for these transactions: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. The master issues a START to start this transaction. The master sends the 7-bit slave address followed by a write bit (low). The slave asserts the ACK. The master sends the Block Read command code (F1h) and the slave asserts the ACK. The master sends the Byte Count (2h) for this transaction and the slave asserts the ACK. The master sends the Start Register Address and the slave asserts the ACK. The master sends the Byte Count (1-20h) for the Block-Read Process Call and the slave asserts the ACK. The master sends a STOP to end this transaction. The master sends a START to start this transaction. The master sends the 7-bit slave address followed by a write bit (low) and the slave asserts the ACK. The master sends the Block Read Command code (F1h) and the slave asserts the ACK. The master sends a repeat START. The master sends the 7-bit slave address followed by a read bit (high) and the slave asserts the ACK. The master receives Byte Count (this matches the size sent by the master in step 7) and asserts the ACK. The master receives Data Byte 1 and asserts the ACK. The master receives Data Byte 2 and asserts the ACK. The master receives N-3 data bytes, and asserts ACK for each one. The master receives the last data byte and asserts a NACK. The master issues a STOP to end this transaction. 23 www.national.com LM96194 1 2 S Slave Address W 11 3 4 A Block Read Comman d Code (F1h) 5 6 A Byte Count (2h) R A A 12 13 A ... Block Read Command Code (F1h) S Slave Address 7 Start Register Address 14 A Byte Count (1-20h) (N) 15 Byte Count (1-20h) (N) A A 8 9 10 P S Slave Address A ... Data Byte N 16 Data Byte 1 A W 17 Data Byte 2 ... A 16 /A P Special Notes: 1. Steps 9 through 19 can be repeated to read another block of data. The address auto-increments such that the next block starts where the last block left off. The size returned by the LM96194 is the same each time. 2. The LM96194 returns 00h when address locations outside of normal address space are read. 3. Block reads do not wrap around from address FFh to 00h 4. If the master acknowledges more bytes that it requested, the LM96194 continues to supply data until the master does not acknowledge a byte. 5. If the master does not acknowledges a byte to prematurely abort a block read, the LM96194 gets off the bus to allow the master to issue a STOP signal. 6. After a block read is finished, the base address of the LM96194 is updated to point to the byte just beyond the last byte read. 14.5.4.5 SMBus Fixed Address Block Reads Block reads can be performed from pre-defined addresses. A special command code has been reserved for each pre-defined address. See the Section 14.5.2 Block Command Code Summary for more details on the command codes. Below is the sequence of events that occur for this type of block read: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. The master sends a START to start this transaction. The master sends the 7-bit slave address followed by a write bit (low). The slave asserts an ACK. The master sends a Fixed Block Command Code (F2h-FDh) and the slave asserts an ACK. The master sends a repeated START. The master sends the 7-bit slave address followed by a read bit (high). The slave asserts an ACK. The master receives the Byte Count (depends on the Fixed Block Command Code used) and asserts an ACK. The master receives the first data byte and asserts an ACK. The master continues to receive data bytes and asserting an ACK. The master receives the last data byte. The master asserts a NACK. The master issues a STOP to end this transaction. 1 2 S Slave Address W 3 4 A Fixed Block Command Code (F2h-FDh) A 5 6 S Slave Address R 7 8 A Byte Count (N) 9 A Data Byte 1 A 10 11 12 13 ... Data Byte N /A P Special Notes: 1. The LM96194 returns 00h when address locations outside of normal address space are read. 2. Block reads do not wrap around from address FFh to 00h. 3. If the master acknowledges more bytes that it requested, the LM96194 continues to supply data until the master does not acknowledge a byte. 4. If the master does not acknowledges a byte to prematurely abort a block read, the LM96194 gets off the bus to allow the master to issue a STOP signal. www.national.com 24 LM96194 14.5.4.6 I2C Block Reads The LM96194 supports I2C block reads. The following sequence of events occur in this transaction: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. The master sends a START to start this transaction . The master send 7-bit slave address followed by a write bit (low). The slave asserts an ACK. The master sends the register address and the slave asserts an ACK. The master sends a repeated START. The master sends the 7-bit slave address followed by a read bit (high). The slave asserts an ACK. The master receives Data Byte 1 and asserts an ACK. The master continues to receive bytes and asserting an ACK for each byte received. The master receives the last byte. The master asserts a NACK. The master issues a STOP. 1 2 S Slave Address W 3 4 A Register Address A 5 6 S Slave Address R 7 8 A Data Byte 1 9 A Data Byte 2 A ... 10 11 12 ... Data Byte N /A P Special Notes: 1. The LM96194 returns 00h when address locations outside of normal address space are read. 2. Block reads do not wrap around from address FFh to 00h. 3. If the master acknowledges more bytes that it requested, the LM96194 continues to supply data until the master does not acknowledge a byte. 4. If the master does not acknowledges a byte to prematurely abort a block read, the LM96194 gets off the bus to allow the master to issue a STOP signal. tion of RESET the sleep control register shall be automatically set to S4/S5. This causes several error events to be masked according to the S4/S5 masking definitions. Since the RESET pin becomes an active input, it must not be left floating at any time as this may cause the LM96194 to drift into S4/S5 and thus have unpredictable behavior. RESET must be asserted for more than 4s in order to guarantee detection. 14.6 READING AND WRITING 16-BIT REGISTERS Whenever the low byte of a 16-bit register is read, the high byte is frozen. After the high byte is read, it is unfrozen. This ensures that the entire 16-bit value is read properly and the high byte matches with the low byte. If the low byte of a different 16-bit register is read, the currently frozen high byte is unfrozen and the high byte of the new 16-bit register is frozen. In a system with two SMBus masters, it is very important that only one master reads any 16-bit registers at a time. One possible method to achieve this would involve using 16-bit SMBus reads (instead of two separate 8-bit reads) to read 16bit registers. Whenever the low byte of a 16-bit register is written, the write is buffered and does not take effect until the corresponding high byte is written. If the low byte of a different 16-bit register is written, the previously buffered low byte of the first register is discarded. If a device attempts to write the high byte of a 16-bit register, and the corresponding low byte was not written (or was discarded), then the LM96194 will NACK the byte. Register Types Power On Reset Factory regs x BMC Error Status regs x Host Error Status regs x External Reset Value regs 15.0 Using The LM96194 Limit regs x Setup regs x LM96194 Configuration Lock Bit x LM96194 Configuration GMSK Bit x (reset) Sleep Mask 15.1 POWER ON The LM96194 generates a power on reset signal on RESET when power is applied for the first time to the part. x Sleep State Control Other Mask regs x x x All other registers are not effected by power on reset or external reset. 15.2 RESETS Upon power up, the RESET output is asserted when the voltage on the power supply crosses the power-on-reset threshold level (see Electrical Specifications). The RESET output is open-drain and should be used with an external pull-up resistor connected to VDD. Once the power on reset has completed, the RESET pin becomes an input and 10 s after assertion of RESET the LOCK bit in the LM96194 Configuration register shall be cleared. In addition, 10 s after asser- 15.3 ADDRESS SELECTION LM96194 is designed to be used primarily in dual processor server systems that may require only one monitoring device. If multiple LM96194 devices are implemented in a system, they must have unique SMBus slave addresses. See the Section 14.1 SMBus ADDRESSING for more information. 25 www.national.com LM96194 The board designer may apply a 10 k pull-down and/or pullup resistors to ground and/or to 3.3V SB VDD on the ADDR_SEL pin. The LM96194 is designed to work with resistors of 5% tolerance for the case where two resistors are required. Upon the first SMBus communication to the part, the LM96194 assigns itself an SMBus address according to the ADDR_SEL input. Address Select Board Implementation SMBus Address less-than 10% of VDD Pulled to ground through a 10 k resistor 0101 100b VDD/2 10 k (5%) Resistor to 3.3V SB VDD and to Ground 0101 110b greater-than 90% of VDD Pulled to 3.3V SB VDD through a 10 k resistor 0101 101b 15.4 DEVICE SETUP BIOS executes the following steps to configure the registers in the LM96194. All steps may not be necessary if default values are acceptable. Set limits and parameters (not necessarily in this order): Set up Fan control Set up PWM temperature bindings Set fan tach limits Set fan boost temperature and hysteresis Set the VRD_HOT and PROCHOT PWM ramp control rate Enable Smart Tach Mode and Tachometer Input to PWM binding (required with PWM drive of fan ground or power pins) Set the temperature absolute limits Set the temperature hysteresis values Set temperature filtered or unfiltered usage 15.5 ROUND ROBIN VOLTAGE/TEMPERATURE CONVERSION CYCLE The LM96194 monitoring function is started as soon as the part is powered up. The LM96194 performs a "round robin" sampling of the inputs, in the order shown below. Each cycle of the round robin is completed in less than 100 ms. The results of the sampling and conversions can be found in the value registers and are available at any time. Channel # Input Temp Zone 3 Internal Temperature Reading 1 Temp Zone 1a Remote Diode 1a Temp Reading Temp Zone 1b Remote Diode 1b Temp Reading (if selected) Temp Zone 2a Remote Diode 2a Temp Reading Temp Zone 2b Remote Diode 2b Temp Reading (if selected) 4 AIN1 +12V1 (if selected) 5 AIN2 +12V2 (if selected) 6 AIN3 +12V3 10 AIN4 CPU_1Vccp 12 AIN5 3.3V 16 AIN6 Mem_Vtt 17 AIN7 GBIT_Core 18 AIN8 -12V 19 AIN9 3.3V SB VDD Supply Rail www.national.com 15.6 ERROR STATUS REGISTERS The LM96194 contains several error status registers for the BMC side, and duplicated error status registers for the Host side. These registers are used to reflect the state of all the possible error conditions that the LM96194 monitors. The BMC/Host Error Status registers hold a set bit until the event is cleared by software, even if the condition causing the error event goes away. To clear a bit in the Error Status registers, a `1' has to be written to the specific bit that is required to be cleared. If the event that caused the error is no longer active then the bit is cleared. Clearing a bit in a BMC Error Status register does not clear the corresponding bit in the Host Error Status register or vise versa. Typical Assignment 3 2 Set the Zone Adjustment Offset temperature Set the PROCHOT override and time interval values Set the PROCHOT user limit Enable THERMTRIP masking of error events (if GPIO4 is used as THERMTRIP input) Set voltage sensor limits and hysteresis Set the Dynamic Vccp offset limits Set the Sleep State control and mask registers Set Other Mask Registers (GPI Error, VRD_HOT, and Dynamic Vccp limit checking) Set start bit to select user values and unmask error events Set the sleep state to 0 Set Lock bit to lock the limit and parameter registers (optional) 15.6.1 ASF Mode Error Status registers function allow the LM96194 to act as a legacy sensor (6.1.2 of ASF spec DSP0114 rev 2) and to easily connect to the SMBus of an ASF capable NIC chip. The LM96194 can be placed into ASF mode by setting the appropriate bit in the LM96194 Status/Control register. Once this bit is set, the BMC Error Status registers become readto-clear. Writing a `1' to clear a particular bit is also allowed in ASF mode. The Host Error Status registers are not effected by ASF mode. 15.7 MASKING, ERROR STATUS AND ALERT Masking is always applied to bits in the HOST and BMC Error Status registers. If an event is masked, the corresponding error bit in the HOST or BMC Error Status registers is prevented from ever being set. As a result, this prevents the event from ever causing ALERT to be asserted. Masking an event does not clear its associated Error Status bit if it is currently set. Voltage errors are masked by writing a high voltage limit value of FFh. This is the default high limit for all voltages. 26 20194415 15.9.1 DIODE NON-IDEALITY 15.9.1.1 Diode Non-Ideality Factor Effect on Accuracy When a transistor is connected as a diode, the following relationship holds for variables VBE, T and IF: (6) where: 15.8 LAYOUT AND GROUNDING Analog components such as voltage dividers should be physically located as close as possible to the LM96194. See Section 15.9.2 PCB Layout for Minimizing Noise for thermal diode layout recommendations. The LM96194 bypass capacitors, the parallel combination of 100 pF, 10 F (electrolytic or tantalum) and 0.1 F (ceramic) bypass capacitors must be connected between power pin (pin 39) and ground, and should be located as close as possible to the LM96194. The 100 pF capacitor should be placed closest to the power pin. * * * * q = 1.6x10-19 Coulombs (the electron charge), T = Absolute Temperature in Kelvin k = 1.38x10-23joules/K (Boltzmann's constant), is the non-ideality factor of the process the diode is manufactured on, * IS = Saturation Current and is process dependent, * If= Forward Current through the base emitter junction * VBE = Base Emitter Voltage drop In the active region, the -1 term is negligible and may be eliminated, yielding the following equation 15.9 THERMAL DIODE APPLICATION To measure temperature external to the LM96194, use a remote discrete diode to sense the temperature of external objects or ambient air. The temperature of a discrete diode is affected, and often dominated, by the temperature of its leads. Most silicon diodes do not lend themselves well to this application. It is recommended that a MMBT3904 transistor type base emitter junction be used with the collector tied to the base. (7) In Equation 7, and IS are dependant upon the process that was used in the fabrication of the particular diode. By forcing two currents with a well controlled ratio(IF2/IF1) and measuring the resulting voltage difference, it is possible to eliminate the IS term. Solving for the forward voltage difference yields the relationship: (8) Solving Equation 8 for temperature yields: (9) 27 www.national.com LM96194 Thermal Diode Temperature vs. LM96194 Temperature Reading Temperature errors are masked by writing a high temperature limit value of 80h. This is the default high limit for all temperatures. Masking a temperature channel masks both temperature errors and diode fault errors. The GPI Mask register allows GPI errors to be masked. Any bits that are set in this register mask events for the corresponding GPIO_x pin. User PROCHOT status is not really an error but it can be used to notify the user of processor throttling past a preset USER limit. A user limit of FFh acts as the mask for this register. Error bits associated with the predefined PROCHOT thresholds cannot be masked. It is important to note though, that these error bits do not cause BMC_ERR, HOST_ERR, or ALERT to be asserted under any condition. Fan tach errors are masked if the tach limit for the given tach is set to FFh . GPI errors and VRD_HOT errors can be masked by setting the appropriate bit in the GPI and Miscellaneous Error Mask registers. When the LM96194 powers up, the ALERT output is disabled. The ALERT output can be enabled by setting the ALERT_EN bit in the LM96194 Configuration register. In addition the manual masking options, the LM96194 also masks some errors depending on the sleep state of the system. The sleep state of the system is communicated to the LM96194 by writing to the Sleep State Control register. Some types of error events are always masked in certain sleep modes. Some types of error events are optionally masked in certain sleep modes if their sleep mask register bit is set. Refer to the register descriptions for more information. LM96194 Equation 9 holds true when a diode connected transistor such as the MMBT3904 is used. When this "diode" equation is applied to an integrated diode such as a processor transistor with its collector tied to GND as shown in Figure 5 it will yield a wide non-ideality spread. This wide non-ideality spread is not due to true process variation but due to the fact that Equation 9 is an approximation. TruTherm technology uses the transistor equation, Equation 10, which is a more accurate representation of the topology of the thermal diode found in an FPGA or processor. (10) 20194443 FIGURE 5. Thermal Diode Current Paths TruTherm should only be enabled when measuring the temperature of a transistor integrated as shown in the processor of Figure 5, because Equation 10 only applies to this topology. LM96194 accommodates the typical series resistance of the Pentium D processor on 90 nm process. The error that is not accounted for is the spread of the Pentium's series resistance, that is 2.79 to 6.24 or 1.73. The equation to calculate the temperature error due to series resistance (TER) for the LM96194 is simply: 15.9.1.2 Calculating Total System Accuracy The voltage seen by the LM96194 also includes the IFRS voltage drop of the series resistance. The non-ideality factor, , is the only other parameter not accounted for and depends on the diode that is used for measurement. Since VBE is proportional to both and T, the variations in cannot be distinguished from variations in temperature. Since the nonideality factor is not controlled by the temperature sensor, it will directly add to the inaccuracy of the sensor. For the PentiumTM D processor on 65nm process, Intel specifies a +4.06%/-0.89% variation in from part to part when the processor diode is measured by a circuit that assumes diode equation, Equation 9, as true. As an example, assume a temperature sensor has an accuracy specification of 2.5C at a temperature of 75 C (348 Kelvin) and the processor diode has a non-ideality variation of +4.06%/-0.89%. The resulting system accuracy of the processor temperature being sensed will be: (11) Solving Equation 11 for RPCB equal to 1.73 results in the additional error due to the spread in the series resistance of 1.07C. The spread in error cannot be canceled out, as it would require measuring each individual thermal diode device. This is quite difficult and impractical in a large volume production environment. Equation 11 can also be used to calculate the additional error caused by series resistance on the printed circuit board. Since the variation of the PCB series resistance is minimal, the bulk of the error term is always positive and can simply be cancelled out by subtracting it from the output readings of the LM96194. 15.9.1.3 Compensating for Different Non-Ideality In order to compensate for the errors introduced by non-ideality, the temperature sensor is calibrated for a particular processor. National Semiconductor temperature sensors are always calibrated to the typical non-ideality and series resistance of a given processor type. The LM96194 is calibrated for two non-ideality factors and series resistance values thus supporting the MMBT3904 transistor and the Pentium D processor on 65nm process without the requirement for additional trims. For most accurate measurements TruTherm mode should be turned on when measuring the Pentium D processor on the 65nm process the error introduced by the false non-ideality spread (see Section 15.9.1.1 Diode NonIdeality Factor Effect on Accuracy). When a temperature sensor calibrated for a particular processor type is used with a different processor type, additional errors are introduced. Temperature errors associated with non-ideality of different processor types may be reduced in a specific temperature TACC = 2.5C + (+4.06% of 348 K) = +16.6 C and TACC = 2.5C + (-0.89% of 348 K) = -5.6 C TruTherm technology uses the transistor equation, Equation 10, resulting in a non-ideality spread that truly reflects the process variation which is very small. The transistor equation non-ideality spread is 0.4% for the Pentium D processor on 65nm process. The resulting accuracy when using TruTherm technology improves to: TACC = 2.5C + (0.4% of 348 K) = 3.9 C The next error term to be discussed is that due to the series resistance of the thermal diode and printed circuit board traces. The thermal diode series resistance is specified on most processor data sheets. For the Pentium D processor on 65 nm process, this is specified at 4.52 typical. The www.national.com 28 TCF = [(S-Processor) / S] x (TCR+ 273 K) LM96194 Recommended Diode Trace Layout range of concern through use of software calibration. Typical non-ideality specification differences cause a gain variation of the transfer function, therefore the center of the temperature range of interest should be the target temperature for calibration purposes. The following equation can be used to calculate the temperature correction factor (TCF) required to compensate for a target non-ideality differing from that supported by the LM96194. (12) where * S = LM96194 non-ideality for accuracy specification * T = target thermal diode typical non-ideality * TCR = center of the temperature range of interest in C The correction factor of Equation 12 should be directly added to the temperature reading produced by the LM96194. For example when using the LM96194, with the 3904 mode selected, to measure a AMDTM Athlon processor, with a typical non-ideality of 1.008, for a temperature range of 60 C to 100 C the correction factor would calculate to: 20194420 6. Avoid routing diode traces in close proximity to any power supply switching or filtering inductors. 7. Avoid running diode traces close to or parallel to high speed digital and bus lines. Diode traces should be kept at least 2 cm apart from the high speed digital traces. 8. If it is necessary to cross high speed digital traces, the diode traces and the high speed digital traces should cross at a 90 degree angle. 9. The ideal place to connect the LM96194's GND pin is as close as possible to the Processors GND associated with the sense diode. In the case of two processors pick a node in between the two that has the least noise. 10. Leakage current between Remote+ and GND should be kept to a minimum. Error in the diode temperature reading may reach 0.4C with 30 nA of leakage current. Keeping the printed circuit board as clean as possible minimizes leakage current. The residue from some freeze spray can induce high leakage current. TCF=[(1.003-1.008)/1.003]x(80+273) =-1.75C Therefore, 1.75C should be subtracted from the temperature readings of the LM96194 to compensate for the differing typical non-ideality target. 15.9.2 PCB Layout for Minimizing Noise In the following guidelines, Remote+ and Remote -- refer to the REMOTE1a+, Remote 1b+, REMOTE1-, REMOTE2a+, Remote2b+ and REMOTE2- pins. In a noisy environment, such as a power supply, layout considerations are very critical. Noise induced on traces running between the remote temperature diode sensor and the LM96194 can cause temperature conversion errors. The following guidelines should be followed: 1. Place a 0.1 F and 100 pF LM96194 power bypass capacitors as close as possible to the VDD pin, with the 100pF capacitor being the closest. Place 10 F capacitor in the near vicinity of the LM96194 power pin. 2. Place a 100 pF capacitor as close as possible to the LM96194 thermal diode Remote+ and Remote- pins. Make sure the traces to the 100 pF capacitor are matched and as short as possible. This capacitor is required to minimize high frequency noise error. 3. Thermal diodes that share one Remote- pin must have a separate trace from the LM96194 Remote- pin run to each diode cathode. Do not "daisy chain" these connections. 4. Ideally, the LM96194 should be placed within 10 cm of the thermal diode pins with the traces being as straight, short and identical as possible. Trace resistance of 1 can cause as much as 1C of error. 5. Diode traces should be surrounded by a GND guard ring to either side, above and below, if possible. This GND guard should not be between the Remote+ and Remote - lines. In the event that noise does couple to the diode lines, it would be ideal if it is coupled to both identically, i.e. common mode. That is, equally to the Remote+ (D+) and Remote-(D-) lines. (See figure below): 15.10 FAN CONTROL 15.10.1 Automatic Fan Control Methods The LM96194 fan speed control method is optimized for fan noise reduction, fan power efficiency, fan reliability and minimum cost. The PWMx outputs can be filtered using an external switching regulator type output stage that provides 5V to 12V DC for fan power. A high PWM frequency is required to minimize the size and cost of the inductor and other components used in the output stage. The PWM outputs of the LM96194 can operate up to 22.5 kHz with a variable step size depending on the fan control mode of operation. The LM96194 supports LUT (Lookup Table) and PI (Proportional Integral) fan control methods. These methods can function interactively or independently as controlled by the PWM binding registers. Figure 6 shows the high level block diagram for these fan control methods. The mapping/binding of the temperature zones to the LUTs is completely independent of the PI loops. The temperature zones can be first independently bound to the LUTs and/or PI loops then each LUT or PI loop can be bound to either PWM Output. The LUT parameters are independent of the temperature zone binding. The PI loop controller is a proportional-integral feedback controller. It generates a 9-bit PWM duty cycle and uses temperature feedback from the processor thermal zones (Zones 1 and 2). The PWM output controls the airflow over the processors and thus the temperature of the processors is adjusted by the PI loop to maintain the hottest temperature reading between the values Tcontrol and Tcontrol - hysteresis. The LM96194 supports 2 processors and each processor can have two thermal sub-zones. The hottest of each processor temperature is reported to the Zone selectors and PI loop inputs. Each processor has an independent Tcontrol setting. 29 www.national.com LM96194 20194429 FIGURE 6. LUT and PI controller high level block diagram 15.10.2 Alternate LUT PWM Mapping The PWM output can operate at lower frequencies, instead of the default 22.5 kHz. The lower frequencies can be enabled through the PWMx Control 4 registers. Operating in the lower frequency mode, enables an alternate mapping of step numbers to duty cycle. This effects the auto fan control and all LM96194 registers that describe a duty cycle using a 4-bit value. This alternate mapping can also be enable when using the default 22.5 kHz PWM frequency. The alternate LUT PWM duty cycle mapping is listed in the following table: www.national.com 4-Bit Value LUT Step Alternate LUT Duty Cycle 1h 1 25.00% 2h 2 28.57% 3h 3 32.14% 4h 4 35.71% 5h 5 39.29% 6h 6 42.86% 7h 7 46.43% 0h 30 0% LUT Step Alternate LUT Duty Cycle 8h 8 50.00% 9h 9 53.57% Ah 10 57.14% Bh 11 71.43% Ch 12 85.71% Dh 13 100.00% Eh -- Reserved Fh -- Reserved 1. The current duty cycle being requested by other PWM functions is memorized. 2. The ramp function immediately adds one PWM duty cycle step to the memorized value and requests this duty cycle. Once the function is enabled, it gradually adds additional duty cycle steps every X milliseconds whenever VRD_HOT is asserted (X is programmable via the PWM Ramp Control register). If VRD_HOT remains asserted for a long enough time, the duty cycle eventually reaches 100%. Whenever VRD_HOT is de-asserted, the ramp function begins to ramp down by subtracting one PWM duty cycle step every X milliseconds. If VRD_HOT is currently de-asserted, and the ramp function is less than to the PWM duty cycle being requested by other functions, the ramp function is disabled. As long as the function is enabled, it continues to ramp up or ramp down depending on the state of VRD_HOT. The ramp enabling process described above can only re-occur after the ramp function has been disabled. Rapid assertion/de-assertion of VRD_HOT does not trigger the enabling process unless VRD_HOT was de-asserted long enough for the ramp function to disable itself. This ramp function only applies to the PWM(s) that are bound to the VRD_HOT inputs. Depending on the bindings, it is possible that up to two independent ramp functions are active at any given moment: PWM1/VRD PWM2/VRD 15.10.3 Fan Control Priorities The automatic fan control is not the only function that influences PWM duty cycle. There are several other functions that influence the PWM duty cycle. All the functions can be classified into several categories: Category # Category Name 1 PWM to 100% conditions 2 VRD_HOT ramp-up/ramp-down 3 PROCHOT ramp-up/ramp-down function 4 Manual PWM Override 5 Fan Spin-Up Control 6 Automatic Fan Control Algorithm The ultimate PWM duty cycle that is chosen can be described by the following formula: If (Manual PWM Override is active) PWM = max(1,2,3,4) Else PWM = max(1,2,3,5,6) So in general, categories 1, 2 and 3 are always active. In addition to that, either category 4 or categories 5 and 6 are active depending on whether manual override is enabled. In this sense the manual override, when enabled, replaces category 5 and 6. 15.10.6 PROCHOT Ramp-Up/Ramp-Down This function is very similar to the VRD_HOT ramp-up/rampdown function. The PWM duty cycle ramps up in the same fashion whenever the PROCHOT measurement exceeds the user programmed threshold. Once a new PROCHOT measurement is made that no longer exceeds the user limit, the PWM will begin to ramp down. Just as with the VRD_HOT ramp function, the PROCHOT ramp function uses independent bindings to determine which PWM outputs should be effected by each PROCHOT input. 15.10.7 Manual PWM Override When a PWM channel is configured for manual PWM override, software can manually control the PWM duty cycle. There are some PWM control functions that could still cause the duty cycle to be higher than the manual setting. See the Section 15.10.3 Fan Control Priorities for details. 15.10.4 PWM to 100% Conditions There are several conditions that cause the duty cycles of all PWM outputs to immediately get set to 100%. They are: 1. any of the four temperature zones exceed the programmed Fan Boost Limit setting but has not yet cooled down enough to drop below the hysteresis point 2. a tachometer reading exceeds its limit 3. the OVRID bit is set in the LM96194 Status/Control 15.10.8 Fan Spin-Up Control All of the other PWM control functions are combined to produce a final duty cycle that is actually used for the PWM output. If this final value changes from zero to a non-zero value, the Fan Spin-Up Control function is triggered. Once triggered, the Fan Spin-Up Control requests the programmed duty cycle for a programmed period of time. 15.10.5 VRD_HOT Ramp-Up/Ramp-Down This function causes the duty cycle of the PWM outputs to gradually increase over time if VRD_HOT is asserted. When VRD_HOT is asserted, the ramp function is enabled. The enabling process involves two steps: 31 www.national.com LM96194 4-Bit Value LM96194 15.11 XOR TREE TEST An XOR tree is provided in the LM96194 for Automated Test Equipment (ATE) board level connectivity testing. This allows the functionality of all digital inputs to be tested in a simple manner and any pins that are non-functional or shorted toThe following signals are included in the XOR test tree: VIDx GPIO_x PWMx gether to be identified. When the test mode is enabled by setting the `XEN' bit in the XOR Test register, the part enters XOR test mode. PROCHOT VRD_HOT GPIx RESET Since the test mode is XOR tree, the order of the signals in the tree is not important. SMBDAT and SMBCLK should not be included in the test tree. Example of XOR Test Tree (not showing all signals) 20194419 To properly implement the XOR TREE test on the PCB, no pins listed in the tree should be connected directly to power or ground. If a pin needs to be configured as a permanent low, such as a GPI, it should be connected to ground through a www.national.com low value resister such as 10 k, to allow the ATE (Automatic Test Equipment) to drive it high. When generating test waveforms, a typical propagation delay of 500 ns through the XOR tree should be allowed for. 32 LM96194 16.0 Registers 16.1 REGISTER WARNINGS In most cases, reserved registers and register bits return zero when read. This should not be relied upon, since reserved registers can be used for future expansion of the LM96194 functions. Some registers have "N/D" for their default value. This means that the power-up default of the register is not defined. In the case of value registers, care should be taken to ensure that software does not read a value register until the associated measurement function has acquired a measurement. This applies to temperatures, voltages, fan RPM, and PROCHOT monitoring. 16.2 REGISTER SUMMARY TABLE Register Key Term Loc k Register Name Description N/D Not Defined N/A Not Applicable R Read Only R/W Read or Write RWC Read or Write to Clear Address Default Description FACTORY REGISTERS x XOR Test 00h 00h Used to set the XOR test tree mode SMBus Test 01h 00 SMBus read/write test register Reserved 02h-04h N/D 05h 00h Selects Diode Mode (default) or Transistor Mode for "Remote Diode" measurements Zone 1b (CPU Diode b) Temp 06h 00h Measured value of remote thermal diode temperature channel 1b Zone 2b (MMBT3904 Diode b) Temp "REMOTE DIODE" MODE SELECT x Transistor Mode Select VALUE REGISTER SECTION 1 07h 00h Measured value of remote thermal diode temperature channel 2b Zone 1b (CPU Diode b) Filtered Temp 08h 00h Filtered value of remote thermal diode temperature channel 1b Zone 2b (MMBT3904 Diode b) Fitlered 09h Temp 00h Filtered value of remote thermal diode temperature channel 2b PWM1 8-bit Duty Cycle Value 0Ah 00h 8- bit value of the PWM1 duty cycle. PWM2 8-bit Duty Cycle Value 0Bh 00h 8-bit value of the PWM2 duty cycle HIGH RESOLUTION PWM OVERIDE REGISTERS x PWM1 Duty Cycle Override (low byte) 0Ch 00h Lower byte of the high resolution PWM1 duty cycle register x PWM1 Duty Cycle Override (high byte) 0Dh 00h Upper byte of the high resolution PWM1 duty cycle register x PWM2 Duty Cycle Override (low byte) 0Eh 00h Lower byte of the high resolution PWM2 duty cycle register x PWM2 Duty Cycle Override (high byte) 0Fh 00h Upper byte of the high resolution PWM2 duty cycle register EXTENDED RESOLUTION TEMPERATURE VALUE REGISTERS Z1a_LSB 10h 00h Zone 1a (CPU) extended resolution unfiltered temperature value register, least-significant byte Z1a_MSB 11h 00h Zone 1a (CPU) extended resolution unfiltered temperature value register, most-significant byte Z1b_LSB 12h 00h Zone 1b (CPU) extended resolution unfiltered temperature value register, least-significant-byte Z1b_MSB 13h 00h Zone 1b (CPU) extended resolution unfiltered temperature value register, most-significant byte Z2a_LSB 14h 00h Zone 2a (MMBT2904) extended resolution unfiltered temperature value register, least-significant-byte 33 www.national.com LM96194 Loc k Register Name Address Default Description Z2a_MSB 15h 00h Zone 2a (MMBT3904) extended resolution unfiltered temperature value register, most-significant byte Z2b_LSB 16h 00h Zone 2b (MMBT3904) extended resolution unfiltered temperature value register, least-significant-byte Z2b_MSB 17h 00h Zone 2b (MMBT3904) extended resolution unfiltered temperature value register, most-significant byte Z1a_F_LSB 18h 00h Zone 1a (CPU) extended resolution filtered temperature value register, least-significant byte Z1a_F_MSB 19h 00h Zone 1a (CPU) extended resolution filtered temperature value register, most-significant byte Z1b_F_LSB 1Ah 00h Zone 1b (CPU) extended resolution filtered temperature value register, least-significant-byte Z1b_F_MSB 1Bh 00h Zone 1b (CPU) extended resolution filtered temperature value register, most-significant byte Z2a_F_LSB 1Ch 00h Zone 2a (MMBT3904) extended resolution filtered temperature value register, least-significant-byte Z2a_F_MSB 1Dh 00h Zone 2a (MMBT3904) extended resolution filtered temperature value register, most-significant byte Z2b_F_LSB 1Eh 00h Zone 2b (MMBT3904) extended resolution filtered temperature value register, least-significant-byte Z2b_F_MSB 1Fh 00h Zone 2b (MMBT3904) extended resolution filtered temperature value register, most-significant byte Z3_LSB 20h 00h Zone 3 (Internal) extended resolution temperature value register, least-significant byte Z3_MSB 21h 00h Zone 3 (Internal) extended resolution temperature value register, least-significant byte Z4_LSB 22h 00h Zone 4 (External Digital) extended resolution temperature value register, most-significant byte Z4_MSB 23h 00h Zone 4 (External Digital) extended resolution temperature value register, least-significant byte Reserved 24h-30h N/D PI LOOP AND FAN CONTROL SETUP REGISTERS x Temperature Source Select 31h 00h Selects the temperature source for some temperature zones. x PWM Filter Settings 32h 00h Sets the IIR filter coefficients for the PWM outputs for low resolution sources x PWM1 Filter Shutoff Threshold 33h 00h PWM1 Filter Shutoff Threshold x PWM2 Filter Shutoff Threshold 34h 00h PWM2 Filter Shutoff Threshold x PI/LUT Fan Control Bindings 35h 30h PI/LUT fan control binding configuration x PI Controller Minimum PWM and Hysteresis 36h 00h PI Controller Minimum PWM and Hysteresis settings x Zone 1 Tcontrol 37h 00h Zone 1 (CPU) PI Controller Target Temperature (Tcontrol) x Zone 2 Tcontrol 38h 00h Zone 2 (MMBT3904) PI Controller Target Temperature (Tcontrol) x Zone 1 Toff 39h 80h Zone 1 (CPU) PI Controller Off Temperature (Toff) x Zone 2 Toff 3Ah 80h Zone 2 (MMBT3904) PI Controller Off Temperature (Toff) x P Coefficient 3Bh 00h PI controller proportional coefficient x I Coefficient 3Ch 00h PI controller integral coefficient x PI Exponents 3Dh 00h PI controller coefficient exponents 3Eh 01h Contains manufacturer ID code DEVICE IDENTIFICATION REGISTERS Manufacturer ID www.national.com 34 Register Name Version/Stepping Address Default LM96194 Loc k Description 3Fh 79h Contains code for major and minor revisions B_Error Status 1 40h 00h BMC error status register 1 B_Error Status 2 41h 00h BMC error register 2 B_Error Status 3 42h 00h BMC error register 3 B_Error Status 4 43h 00h BMC error register 4 B_PROCHOT Error Status 44h 00h BMC error register for PROCHOT Reserved 45h N/D B_GPI Error Status 46h 00h BMC error register for GPIs B_Fan Error Status 47h 00h BMC error register for Fans H_Error Status 1 48h 00h HOST error status register 1 H_Error Status 2 49h 00h HOST error register 2 H_Error Status 3 4Ah 00h HOST error register 3 H_Error Status 4 4Bh 00h HOST error register 4 H_PROCHOT Error Status 4Ch 00h HOST error register for PROCHOT Reserved 4Dh N/D H_GPI Error Status 4Eh 00h HOST error register for GPIs H_Fan Error Status 4Fh 00h HOST error register for Fans Zone 1a (CPU) Temp 50h 00h Measured value of remote thermal diode temperature channel 1a Zone 2a (MMBT3904) Temp 51h 00h Measured value of remote thermal diode temperature channel 2a Zone 3 (Internal) Temp 52h 00h Measured temperature from on-chip sensor Zone 4 (External Digital) Temp 53h 00h Measured temperature from external temperature sensor Zone 1a (CPU) Filtered Temp 54h 00h Filtered value of remote thermal diode temperature channel 1a Zone 2a (MMBT3904) Filtered Temp 55h 00h Filtered value of remote thermal diode temperature channel 2a AD_IN1 Voltage 56h N/D Measured value of AD_IN1 AD_IN2 Voltage 57h N/D Measured value of AD_IN2 AD_IN3 Voltage 58h N/D Measured value of AD_IN3 Reserved 59h-5Bh N/D AD_IN4 Voltage 5Ch N/D Reserved 5Dh N/D AD_IN5 Voltage 5Eh N/D Reserved 5Fh-61h N/D AD_IN6 Voltage 62h N/D Measured value of AD_IN6 AD_IN7 Voltage 63h N/D Measured value of AD_IN7 AD_IN8 Voltage 64h N/D Measured value of AD_IN8 AD_IN9 Voltage 65h N/D Measured value of AD_IN9 (VDD 3.3V S/B) Reserved 66h N/D Current PROCHOT 67h 00h Measured PPROCHOT throttle percentage Average PROCHOT 68h 00h Average PPROCHOT throttle percentage Reserved 69h-6Ah N/D GPI State 6Bh 00h Current GPIO state P1_VID 6Ch 00h Current Processor VID value BMC ERROR STATUS REGISTERS HOST ERROR STATUS REGISTERS VALUE REGISTERS SECTION 2 Measured value of AD_IN4 Measured value of AD_IN5 35 www.national.com LM96194 Loc k Register Name Address Default Description Reserved 6Dh N/D FAN Tach 1 LSB 6Eh 00h Measured FAN Tach 1 LSB FAN Tach 1 MSB 6Fh 00h Measured FAN Tach 1 MSB FAN Tach 2 LSB 70h 00h Measured FAN Tach 2 LSB FAN Tach 2 MSB 71h 00h Measured FAN Tach 2 MSB FAN Tach 3 LSB 72h 00h Measured FAN Tach 3 LSB FAN Tach 3 MSB 73h 00h Measured FAN Tach 3 MSB FAN Tach 4 LSB 74h 00h Measured FAN Tach 4 LSB FAN Tach 4 MSB 75h 00h Measured FAN Tach 4 MSB Reserved 76h-77h N/D Zone 1 (CPU) Low Temp 78h 80h Low limit for external thermal diode temperature channel 1 (D1) measurement Zone 1 (CP1) High Temp 79h 80h High limit for external thermal diode temperature channel 1 (D1) measurement Zone 2 (MMBT3904) Low Temp 7Ah 80h Low limit for external thermal diode temperature channel 2 (D2) measurement Zone 2 (MMBT3904) High Temp 7Bh 80h High limit for external thermal diode temperature channel 2 (D2) measurement Zone 3 (Internal) Low Temp 7Ch 80h Low limit for local temperature measurement Zone 3 (Internal) High Temp 7Dh 80h High limit for local temperature measurement Zone 4 (External Digital) Low Temp 7Eh 80h Low limit for external digital temperature sensor Zone 4 (External Digital) High Temp 7Fh 80h High limit for external digital temperature sensor x Fan Boost Temp Zone 1 80h 3Ch Zone 1 (CPU) fan boost temperature x Fan Boost Temp Zone 2 81h 3Ch Zone 2 (MMBT3904) fan boost temperature x Fan Boost Temp Zone 3 82h 23h Zone 3 (Internal) fan boost temperature x Fan Boost Temp Zone 4 83h 23h Zone 4 (External Digital) fan boost temperature Zone1 and Zone 2 Hysteresis 84h 00h Zone 1 and Zone 2 hysteresis for limit comparisons Zone 3 and Zone 4 Hysteresis 85h 00h Zone 3 and Zone 4 hysteresis for limit comparisons Reserved 86h-8Dh N/D TEMPERATURE LIMIT REGISTERS ZONE 1b and 2b TEMPERATURE READING ADJUSTMENT REGISTERS Zone 1b Temp Adjust 8Eh 00h Allows all Zone 1b temperature measurements to be adjusted by a programmable offset. Zone 2b Temp Adjust 8Fh 00h Allows all Zone 2b temperature measurements to be adjusted by a programmable offset. AD_IN1 Low Limit 90h 00h Low limit for analog input 1 measurement AD_IN1 High Limit 91h FFh High limit for analog input 1 measurement AD_IN2 Low Limit 92h 00h Low limit for analog input 2 measurement AD_IN2 High Limit 93h FFh High limit for analog input 2 measurement AD_IN3 Low Limit 94h 00h Low limit for analog input 3 measurement AD_IN3 High Limit 95h FFh High limit for analog input 3 measurement Reserved 96h-9Dh N/D AD_IN4 Low Limit 9Ch OTHER LIMIT REGISTERS www.national.com 00h Low limit for analog input 4 measurement (Processor Vccp) 36 Register Name Address Default FFh Description AD_IN4 High Limit 9Dh Reserved 9Eh-9Fh N/D High limit for analog input 4 measurement (Processor Vccp) AD_IN5 Low Limit A0h 00h Low limit for analog input 5 measurement AD_IN5 High Limit A1h FFh High limit for analog input 5 measurement Reserved A2h-A7h N/D AD_IN6 Low Limit A8h 00h Low limit for analog input 6 measurement AD_IN6 High Limit A9h FFh High limit for analog input 6 measurement AD_IN7 Low Limit AAh 00h Low limit for analog input 7 measurement AD_IN7 High Limit ABh FFh High limit for analog input 7 measurement AD_IN8 Low Limit ACh 00h Low limit for analog input 8 measurement AD_IN8 High Limit ADh FFh High limit for analog input 8 measurement AD_IN9 Low Limit AEh 00h Low limit for analog input 9 measurement AD_IN9 High Limit AFh FFh High limit for analog input 9 measurement PROCHOT User Limit B0h FFh User settable limit for PROCHOT Reserved B1h N/D Vccp Limit Offsets B2h 17h Reserved B3h N/D FAN Tach 1 Limit LSB B4h FCh FAN Tach 1 Limit LSB FAN Tach 1 Limit MSB B5h FFh FAN Tach 1 Limit MSB FAN Tach 2 Limit LSB B6h FCh FAN Tach 2 Limit LSB FAN Tach 2 Limit MSB B7h FFh FAN Tach 2 Limit MSB FAN Tach 3 Limit LSB B8h FCh FAN Tach 3 Limit LSB FAN Tach 3 Limit MSB B9h FFh FAN Tach 3 Limit MSB FAN Tach 4 Limit LSB BAh FCh FAN Tach 4 Limit LSB FAN Tach 4 Limit MSB BBh FFh FAN Tach 4 Limit MSB Special Function Control 1 BCh 00h Controls the hysteresis for voltage limit comparisons. Also selects filtered or unfiltered temperature usage for temperature limit comparisons and fan control. Special Function Control 2 BDh 00h Enables smart tach detection. Also selects 0.5C or 1.0C resolution for fan control. x GPI / VID Level Control BEh 00h Control the input threshold levels for the VIDx, and GPIO_x inputs. x PWM Ramp Control BFh 00h Controls the ramp rate of the PWM duty cycle when VRD_HOT is asserted, as well as the ramp rate when PROCHOT exceeds the user threshold. x Fan Boost Hysteresis (Zones 1/2) C0h 44h Fan Boost Hysteresis for zones 1 and 2 x Fan Boost Hysteresis (Zones 3/4) C1h 44h Fan Boost Hysteresis for zones 3 and 4 x Zones 1/2 Spike Smoothing Control C2h 00h Configures Spike Smoothing for zones 1 and 2 x LUT 1/2 MinPWM and Hysteresis C3h 00h Controls MinPWM and hysteresis setting for LUT 1 and 2 auto-fan control x LUT 3/4 MinPWM and Hysteresis C4h 00h Controls MinPWM and hysteresis setting for LUT 3 and 4 auto-fan control GPO C5h 00h Controls the output state of the GPIO pins PROCHOT Control C6h 00h Controls assertion PROCHOT VID offset values for window comparator for CPU Vccp (AD_IN4) SETUP REGISTERS 37 www.national.com LM96194 Loc k LM96194 Loc k Register Name Address Default Description PROCHOT Time Interval C7h 11h Configures the time window over which the PROCHOT inputs are measured x PWM1 Control 1 C8h 00h Controls PWM control source bindings. x PWM1 Control 2 C9h 00h Controls PWM override and output polarity x PWM1 Control 3 CAh 00h Controls PWM spin-up duration and duty cycle x PWM1 Control 4 CBh 00h Frequency control for PWM1. x PWM2 Control 1 CCh 00h Controls PWM control source bindings. x PWM2 Control 2 CDh 00h Controls PWM override and output polarity x PWM2 Control 3 CEh 00h Controls PWM spin-up duration and duty cycle x PWM2 Control 4 CFh 00h Frequency control for PWM2 x LUT 1 Base Temperature D0h 00h Base temperature to which look-up table offset is applied for LUT 1 x LUT 2 Base Temperature D1h 00h Base temperature to which look-up table offset is applied for LUT 2 x LUT 3 Base Temperature D2h 00h Base temperature to which look-up table offset is applied for LUT 3 x LUT 4 Base Temperature D3h 00h Base temperature to which look-up table offset is applied for LUT 4 x Step 2 Temp Offset D4h 00h Step 2 LUT 1/2 and LUT 3/4 Offset Temperatures x Step 3 Temp Offset D5h 00h Step 3 LUT 1/2 and LUT 3/4 Offset Temperatures x Step 4 Temp Offset D6h 00h Step 4 LUT 1/2 and LUT 3/4 Offset Temperatures x Step 5 Temp Offset D7h 00h Step 5 LUT 1/2 and LUT 3/4 Offset Temperatures x Step 6 Temp Offset D8h 00h Step 6 LUT 1/2 and LUT 3/4 Offset Temperatures x Step 7 Temp Offset D9h 00h Step 7 LUT 1/2 and LUT 3/4 Offset Temperatures x Step 8 Temp Offset DAh 00h Step 8 LUT 1/2 and LUT 3/4 Offset Temperatures x Step 9 Temp Offset DBh 00h Step 9 LUT 1/2 and LUT 3/4 Offset Temperatures x Step 10 Temp Offset DCh 00h Step 10 LUT 1/2 and LUT 3/4 Offset Temperatures x Step 11 Temp Offset DDh 00h Step 11 LUT 1/2 and LUT 3/4 Offset Temperatures x Step 12 Temp Offset DEh 00h Step 12 LUT 1/2 and LUT 3/4 Offset Temperatures x Step 13 Temp Offset DFh 00h Step 13 LUT 1/2 and LUT 3/4 Offset Temperatures TACH to PWM Binding E0h 00h Controls the tachometer input to PWM output binding x Tach Boost Control E1h 3Fh Controls the fan boost function upon a tach error x LM96194 Status/Control E2h 00h Gives Master error status, ASF reset control and Max PWM control x LM96194 Configuration E3h 00h Configures various outputs and provides START bit SLEEP STATE CONTROL AND MASK REGISTERS Sleep State Control E4h 03h Used to communicate the system sleep state to the LM96194 S1 GPI Mask E5h FFh Sleep state S1 GPI error mask register S1 Fan Mask E6h 0Fh Sleep state S1 fan tach error mask register S3 GPI Mask E7h FFh Sleep state S3 GPI error mask register S3 Fan Mask E8h 0Fh Sleep state S3 fan tach error mask register S3 Temperature/Voltage Mask E9h 07h Sleep state S3 temperature or voltage error mask register S4/5 GPI Mask EAh FFh Sleep state S4/5 GPI error mask register S4/5 Temperature/Voltage Mask EBh 07h Sleep state S4/5 temperature or voltage error mask register GPI Error Mask ECh FFh Error mask register for GPI faults Miscellaneous Error Mask EDh 3Fh Error mask register for VRD_HOT, GPI, and dynamic Vccp limit checking. OTHER MASK REGISTERS www.national.com 38 Register Name Address Default LM96194 Loc k Description ZONE 1a AND 2a TEMPERATURE READING ADJUSTMENT REGISTERS Zone 1a Temp Adjust EEh 00h Allows all Zone 1a temperature measurements to be adjusted by a programmable offset Zone 2a Temp Adjust EFh 00h Allows all Zone 2a temperature measurements to be adjusted by a programmable offset Block Write Command F0h N/A SMBus Block Write Command Code Block Read Command F1h N/A SMBus Block Write/Read Process call Fixed Block 0 F2h N/A Fixed block code address 40h, size 8 bytes Fixed Block 1 F3h N/A Fixed block code address 48h, size 8 bytes Fixed Block 2 F4h N/A Fixed block code address 50h, size 6 bytes Fixed Block 3 F5h N/A Fixed block code address 56h, size 16 bytes Fixed Block 4 F6h N/A Fixed block code address 67h, size 4 bytes Fixed Block 5 F7h N/A Fixed block code address 6Eh, size 8 bytes Fixed Block 6 F8h N/A Fixed block code address 78h, size 12 bytes Fixed Block 7 F9h N/A Fixed block code address 90h, size 32 bytes Fixed Block 8 FAh N/A Fixed block code address B4h, size 8 bytes Fixed Block 9 FBh N/A Fixed block code address C8h, size 8 bytes Fixed Block 10 FCh N/A Fixed block code address D0h, size 16 bytes Fixed Block 11 FDh N/A Fixed block code address E5h, size 9 bytes Reserved FEh-FFh N/A BLOCK COMMANDS Reserved for future commands 39 www.national.com LM96194 16.3 FACTORY REGISTERS 00h-04h 16.3.1 Register 00h XOR Test Register Address Read/ Write Register Name 00h R/W XOR Test Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 RES Bit 0 Default Value XEN 00h Sleep Masking Bit Name R/W Default Description 0 XEN R/W 0 The LM96194 incorporates an XOR tree test mode. When the test mode is enabled by setting this bit, the part enters XOR test mode. Clearing this bit brings the part out of XOR test mode. N/A 7:1 RES R 0 Reserved N/A 16.3.2 Register 01h SMBus Test Register Address Read/ Write Register Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value 01h R/W SMBus Test 7 6 5 4 3 2 1 0 00h This register can be used to verify that the SMBus can read and write to the device without effecting any programmed settings. 16.3.3 "REMOTE DIODE" MODE SELECT 16.3.3.1 Register 05h Remote-Diode Transistor Mode Select Register Address Read/ Write Register Name Bit 7 Bit 6 Bit 5 Bit 4 05h R/W Transistor Mode Select RES RES RES RES Bit 3 Bit 2 Bit 1 Qb_T_EN Qa_T_EN Pb_T_EN Bit 0 Default Value Pa_T_EN 00h Bit Name R/W Description 0 Pa_T_EN R/W If set, Processor Remote-Diode "a" Transistor Mode enabled. 1 Pb_T_EN R/W If set, Processor Remote-Diode "b" Transistor Mode enabled. 2 Qa_T_EN R/W If set, MMBT3904 Remote-Diode "a" Transistor Mode enabled. 3 Qb_T_EN R/W If set, MMBT3904 Remote-Diode "b" Transistor Mode enabled. 7:4 RES R Reserved 16.4 VALUE REGISTERS SECTION 1 16.4.1 Registers 06-07h and 50-53h Register Address Read/ Write 06h 07h Unfiltered Temperature Value Registers Register Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value R Zone 1b (CPU) Temp 7 6 5 4 3 2 1 0 00h R Zone 2b (MMBT3904) Temp 7 6 5 4 3 2 1 0 00h 50h R Zone 1a (CPU) Temp 7 6 5 4 3 2 1 0 00h 51h R Zone 2a (MMBT3904) Temp 7 6 5 4 3 2 1 0 00h 52h R Zone 3 (Internal) Temp 7 6 5 4 3 2 1 0 00h R/W Zone 4 (External Digital) Temp 7 6 5 4 3 2 1 0 00h 53h Zones 1 and 2 are all automatically updated by the LM96194. The Zone 3 (Internal) Temp and Zone 4 (External Digital) Temp registers may be written by an external SMBus device or can be assigned to AD_IN8, respectively. The temperature registers for zones 1 and 2 will return a value of 80h if the remote diode pins are not implemented by the board designer or are not functioning properly. www.national.com 40 Register Address Read/ Write Register Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value 08h R Zone 1b (CPU) Filtered Temp 7 6 5 4 3 2 1 0 00h 09h R Zone 2b (MMBT3904) Filtered Temp 7 6 5 4 3 2 1 0 00h 54h R Zone 1a (CPU) Filtered Temp 7 6 5 4 3 2 1 0 00h 55h R Zone 2a (MMBT3904) Filtered Temp 7 6 5 4 3 2 1 0 00h These registers reflect the temperature of zones 1 and 2 after the spike smoothing filter has been applied. The characteristics of the filtering can be adjusted by using the Zones 1/2 Spike Smoothing Control register. 16.4.3 Register 0Ah and 0Bh PWM1 and PWM2 8-bit Duty Cycle Value Register Address Read/ Write Register Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value 0Ah R PWM1 Duty Cycle Value 7 6 5 4 3 2 1 0 00h 0Bh R PWM2 Duty Cycle Value 7 6 5 4 3 2 1 0 00h These registers report the current duty cycle being driven on the PWM1 or PWM2 outputs. It is the upper 8 bits of the 9-bit PWM value. It reflects the maximum duty cycle of any low-resolution or high-resolution PWM sources bound to the PWM1 or PWM2 outputs. 16.5 PWM Duty Cycle Overide Registers 16.5.1 Register 0Ch PWM1 Duty Cycle Override (low byte) Register Address Read/ Write Register Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value 0Ch R/W PWM1 Duty Cycle Override (low byte) PWM1_ DC[0] PWM1_ EN_Hres _Over RES RES RES RES RES RES 00h Bit Name R/W 5:0 RES R Description 6 PWM1_EN_Hres_Over R/W When this bit is set, high-resolution override for PWM1 is enabled. When this bit is set, PWM1 will run at the programmed duty cycle: PWM1_DC [8:0]/256 * 100%; values over 100h are reserved. 7 PWM1_DC[0] R/W When this bit is set, bit [0] of the override duty cycle for PWM1 is set. Reserved If manual PWM1 override is enabled in this register, all other PWM1 bindings are disabled except for the 100% override in the LM96194 Status Control register (E2h). 16.5.2 Register 0Dh PWM1 Duty Cycle Override (high byte) Register Address Read/ Write Register Name 0Dh R/W PWM1 Duty Cycle Override (high byte) Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 PWM1_DC[8:1] 41 Bit 2 Bit 1 Bit 0 Default Value 00h www.national.com LM96194 16.4.2 Registers 08-09h and 54-55h Filtered Temperature Value Registers LM96194 These bits set the upper 8-bits of the 9-bit override duty cycle value for PWM1. 16.5.3 Register 0Eh PWM2 Duty Cycle Override (low byte) Register Address 0Eh Read/ Write Register Name Bit 7 PWM 2 Duty Cycle Override (low byte) R/W Bit 6 PWM2_ PWM2_ DC[0] EN_Hre s _Over Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value RES RES RES RES RES RES 00h Bit Name R/W 5:0 RES R Description 6 PWM2_EN_Hres_Over R/W When this bit is set, high-resolution override for PWM2 is enabled. When this bit is set, PWM2 will run at the programmed duty cycle: PWM2_DC [8:0]/256 * 100%; values over 100h are reserved. 7 PWM2_DC[0] R/W When this bit is set, bit [0] of the override duty cycle for PWM2 is set. Reserved If manual PWM 2 override is enabled in this register, all other PWM 2 bindings are disabled except for the 100% override in the LM96194 Status Control register (E2h). 16.5.4 Register 0Fh PWM2 Duty Cycle Override (high byte) Register Address Read/ Write Register Name Bit 7 0Fh R/W PWM2 Duty Cycle Override (high byte) Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 PWM2_DC[8:1] Default Value 00h These bits set the upper 8-bits of the 9-bit override duty cycle value for PWM2. 16.6 EXTENDED RESOLUTION VALUE REGISTERS 16.6.1 Registers 10h - 17h Zone 1 (CPU) and Zone 2 (MMBT3904) Extended Resolution Unfiltered Temperature Value Registers, Most and Least Significant Bytes Register Address Read/ Write Register Name Bit 7 Bit 6 10h R Z1a_LSB 0.5 0 11h R Z1a_MSB Sign 64 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value 0 0 0 0 0 0 00h 32 16 8 4 2 1 00h Register 11h is a mirror of register Zone 1a (CPU) Temp at address 50h. Register Address Read/ Write Register Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value 12h R Z1b_LSB 0.5 0 0 0 0 0 0 0 00h 13h R Z1b_MSB Sign 64 32 16 8 4 2 1 00h Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value Register 13h is a mirror of register Zone 1b (CPU) Temp at address 06h. Register Address Read/ Write Register Name Bit 7 Bit 6 Bit 5 14h R Z2a_LSB 0.5 0 0 0 0 0 0 0 00h 15h R Z2a_MSB Sign 64 32 16 8 4 2 1 00h Register 15h is a mirror of register Zone 2a (MMBT3904) Temp at address 51h. www.national.com 42 Read/ Write Register Name Bit 7 Bit 6 16h R Z2b_LSB 0.5 0 17h R Z2b_MSB Sign 64 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value 0 0 0 0 0 0 00h 32 16 8 4 2 1 00h Register 17h is a mirror of register Zone 2b (MMBT3904) Temp at address 07h. 16.6.2 Registers 18h - 1Fh Zone 1 (CPU) and Zone 2 (MMBT3904) Extended Resolution Filtered Value Registers, Most and Least Significant Bytes Register Address Read/ Write 18h R 19h R Register Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value Z1a_F_LSB 0.5 0.25 0.125 0.0625 0 0 0 0 00h Z1a_F_MSB Sign 64 32 16 8 4 2 1 00h Register 19h is a mirror of register Zone 1a (CPU) Filtered Temp at address 54h. Register Address Read/ Write 1Ah R 1Bh R Register Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value Z1b_F_LSB 0.5 0.25 0.125 0.0625 0 0 0 0 00h Z1b_F_MSB Sign 64 32 16 8 4 2 1 00h Register 1Bh is a mirror of register Zone 1b (CPU) Filtered Temp at address 08h. Register Address Read/ Write 1Ch R 1Dh R Register Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value Z2a_F_LSB 0.5 0.25 0.125 0.0625 0 0 0 0 00h Z2a_F_MSB Sign 64 32 16 8 4 2 1 00h Register 1Dh is a mirror of register Zone 2a (MMBT3904) Filtered Temp at address 55h. Register Address Read/ Write Register Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value 1Eh R Z2b_F_LSB 0.5 0.25 0.125 0.0625 0 0 0 0 00h 1Fh R Z2b_F_MSB Sign 64 32 16 8 4 2 1 00h Register 1Fh is a mirror of register Zone 2b (MMBT3904) Filtered Temp at address 09h. 16.6.3 Registers 20h - 23h Zone 3 and Zone 4 Extended Resolution Value Registers, Most and Least Significant Bytes Register Address Read/ Write Register Name Bit 7 Bit 6 20h R/W Z3_LSB 0.5 0 21h R/W Z3_MSB Sign 64 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value 0 0 0 0 0 0 00h 32 16 8 4 2 1 00h Register 21h is a mirror of register Zone 3 (Internal) Temp at address 52h. Register Address Read/ Write Register Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value 22h R/W Z4_LSB 0.5 0 0 0 0 0 0 0 00h 23h R/W Z4_MSB Sign 64 32 16 8 4 2 1 00h Register 23h is a mirror of register Zone 4 (External Digital) Temp at address 53h. 43 www.national.com LM96194 Register Address LM96194 16.7 PI LOOP FAN CONTROL SETUP REGISTERS 16.7.1 Register 31h Internal/External Temperature Source Select Register Address Read/ Write Register Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value 31h R/W Internal/ External Temperature Source Select RES RES RES INT_ WR_E Z2bE Z1bE EXT_ AD8 INT_ DIS 00h Bit Name R/W Description 0 INT_DIS R/W This bit must be left cleared so that the Internal Temperature Register (Zone 3) will be automatically updated with the internal temperature reading from the LM96194's internal thermal diode. All functions related to the Internal Temperature Register value are affected by this bit (LUTs, Temperature Boost, etc.). If this bit is set erroneous values may indavertly be used by the fan control circuitry. 1 EXT_ADC8 R/W When this bit is set, the External Digital Temperature register (Zone 4) will become read-only and will be automatically updated from the ADC_IN15 Voltage Value register minus 128 by inverting the MSb. Subtraction of 128 or inverting the MSb is required since the data in the temperature registers are signed. When this bit is cleared the External Digital Temperature register is writable and must be updated over the SMBus by software. All functions related to the External Digital Temperature register are affected by this bit (LUTs, Temperature Boost, etc.) 2 Z1bE R/W When this bit is set, pin 23 is enabled as a Remote 1b input. When this bit is cleared pin 23 is set as a AD_IN1 input. 3 Z2bE R/W When this bit is set, pin 24 is enabled as a Remote 2b input. When this bit is cleared pin 24 is set as a AD_IN2 input. 4 INT_WR_E R/W When this bit is set, the Internal Temperature Value register may be updated by an external SMBus write. All automatic updates of the Internal Temperature Value register will cease. 7:3 RES R Reserved 16.7.2 Register 32h PWM Filter Settings Register Address Read/ Write Register Name Bit 7 32h R/W PWM_Filter RES Bit 6 Bit 5 FC_PWM2[2:0] Bit 4 Bit 3 RES Bit 2 Bit 1 FC_PWM1[2:0] Bit 0 Default Value 00h Bit Name R/W Description 2:0 FC_PWM1[2:0] R/W Sets the filter coefficient for the IIR filter on PWM1 low resolution sources. 3 RES R 6:4 FC_PWM2[2:0] R/W 7 RES R www.national.com Reserved Sets the filter coefficient for the IIR filter on PWM2 low resolution sources. Reserved FC_PWM1[2:0] or FC_PWM2[2:] 95% Settling Time Interval 000 Filter bypassed 001 0.098s 010 0.237s 011 0.510s 100 1.056s 101 2.147s 110 4.328s 111 8.689s 44 Register Address Read/ Write Register Name 33h R/W PWM1_Filter Shut_Thresh Bit Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 PWM1_SHUT_DC[4:0] Name R/W 2:0 RES R 7:3 PWM1_SHUT_DC[4:0] R/W Bit 2 Bit 1 Bit 0 Default Value RES RES RES 00h Description Reserved Sets the filter shutoff threshold. The actual duty cycle threshold is 3.15% times this value. If the PWM filter is disabled the shutdown threshold is also disabled. The shutdown threshold allows the PWM1 output to be turned off for duty cycles less than the programmed value. Bit [7:3] 9-bit Threshold Corresponding Duty Cycle 0 0 0.000% 1 8 3.125% 2 16 6.25% * * * * * * * * * 29 232 90.625% 30 240 93.750% 31 248 96.875% 16.7.4 Register 34h PWM2 Filter Shutoff Threshold Register Address Read/ Write Register Name 34h R/W PWM2_Filter Shut_Thresh Bit 7 Bit 6 Bit 5 Bit 4 PWM2_SHUT_DC[4:0] Bit Name R/W 2:0 RES R 7:3 PWM2_SHUT_DC[4:0] R/W Bit 3 Bit 2 Bit 1 Bit 0 Default Value RES RES RES 00h Description Reserved Sets the filter shutoff threshold. The actual duty cycle threshold is 3.15% times this value. If the PWM filter is disabled the shutdown threshold is also disabled. The shutdown threshold allows the PWM1 output to be turned off for duty cycles less than the programmed value. Bit [7:3] 9-bit Threshold Corresponding Duty Cycle 0 0 0.000% 1 8 3.125% 2 16 6.25% * * * * * * * * * 29 232 90.625% 30 240 93.750% 31 248 96.875% 45 www.national.com LM96194 16.7.3 Register 33h PWM1 Filter Shutoff Threshold LM96194 16.7.5 Register 35h PI/LUT Fan Control Bindings Register Address Read/ Write Register Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value 35h R/W Fan Control Bindings LUT4 _Z2 LUT3 _Z1 LUT2 _Z2 LUT1 _Z1 PWM2 _PI PWM1 _PI PI_Z2 PI_Z1 30h Bit Name R/W Description 0 PI_Z1 R/W When this bit is set, the PI controller is bound to the P1 temperature (zone 1). This also changes the available filtering options for the P1 temperature. 1 PI_Z2 R/W When this bit is set, the PI controller is bound to the P2 temperature (zone 2). This also changes the available filtering options for the P2 temperature zone. 2 PWM1_PI R/W When this bit is set, the PWM1 output is bound to the PI controller. 3 PWM2_PI R/W When this bit is set, the PWM2 output is bound to the PI controller. 4 LUT1_Z1 R/W When this bit is set, LUT1 will use the P1 temperature (zone 1) instead of the Internal temperature (zone 3). 5 LUT2_Z2 R/W When this bit is set, LUT2 will use the P2 temperature (zone2) instead of the External Digital temperature (zone 4). 6 LUT3_Z1 R/W When this bit is set, LUT3 will use the P1 temperature (zone1) instead of the Internal temperature (zone 3). 7 LUT4_Z2 R/W When this bit is set, LUT4 will use the P2 temperature (zone 2) instead of the External Digital temperature (zone 4). 16.7.6 Register 36h PI Controller Minimum PWM and Hysteresis Register Address Read/ Write Register Name 36h R/W PI MinPWM and Hyst Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 PI_MinPWM[3:0] Bit 1 PI_Hyst[3:0] Bit 0 Default Value 00h Bit Name R/W Description 3:0 PI_Hyst[3:0] R/W Sets the hysteresis for the PI Loop fan controller in 0.5C steps up to 7.5 C. 7:4 PI_MinPWM[3:0] R/W Defines the minimum PWM output for the PI Loop fan controller in 6.25% steps up to 93.75%. PI_Hyst[3:0] www.national.com Hysteresis (C) 0h 0 1h 0.5 2h 1.0 3h 1.5 4h 2.0 5h 2.5 6h 3.0 7h 3.5 8h 4.0 9h 4.5 Ah 5.0 Bh 5.5 Ch 6.0 Dh 6.5 Eh 7.0 Fh 7.5 46 Minimum Duty Cycle 0h 0.00% 1h 6.25% 2h 12.5% 3h 18.75% 4h 25.00% 5h 31.25% 6h 37.50% 7h 43.75% 8h 50.00% 9h 56.25% Ah 62.50% Bh 68.75% Ch 75.00% Dh 81.25% Eh 87.5% Fh 93.75% LM96194 PI_MinPWM[3:0] 16.7.7 Registers 37h and 38h Zone 1 and 2 PI Controller Target Temperature (Tcontrol) Register Address Read/ Write Register Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value 37h R/W Zone 1 Tcontrol 7 6 5 4 3 2 1 0 00h 38h R/W Zone 2 Tcontrol 7 6 5 4 3 2 1 0 00h Same format as temperature value register for Zone 1 and Zone 2. The PWM output controls the airflow over the processors and thus the temperature of the processors is adjusted by the PI loop to maintain the hottest Zone 1 or Zone 2 temperature reading between their respective values for Tcontrol and Tcontrol - hysteresis. Intel specifies an optimum Tcontrol temperature for some of it's processors that can be found in the MSR register space. 16.7.8 Register 39h and 3Ah Zone 1 and 2 PI Fan Control Off Temperature (Toff) Register Address Read/ Write Register Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value 39h R/W Z1 Toff 7 6 5 4 3 2 1 0 80h 3Ah R/W Z2 Toff 7 6 5 4 3 2 1 0 80h Same format as temperature value register for Zone 1 and Zone 2. When these registers are set to 80h, the Toff function is disabled. Toff is the temperature at which the PI control loop output is forced to zero duty cycle. 16.7.9 Register 3Bh Proportional Coefficient Register Address Read/ Write Register Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value 3Bh R/W P Coefficient 7 6 5 4 3 2 1 0 00h 16.7.10 Register 3Ch Integral Coefficient Register Address Read/ Write Register Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value 3Ch R/W I Coefficient 7 6 5 4 3 2 1 0 00h 47 www.national.com LM96194 16.7.11 Register 3Dh PI Coefficient Exponents Register Address Read/ Write Register Name Bit 7 Bit 6 Bit 5 Bit 4 3Dh R/W PI Exponents RES RES RES RES Bit Bit 3 Bit 2 Bit 1 PCE[1:0] Bit 0 Default Value ICE[1:0] 00h Name R/W Description 1:0 ICE[1:0] R/W PI controller integral coefficient exponent (2-bit signed value) 2:3 PCE[1:0] R/W PI controller proportional coefficient exponent (2-bit signed value) 7:4 RES R Reserved ICE[1:0] Integral Exponent 10b -2 11b -1 00b 0 01b 1 PCE[1:0] Proportional Exponent 10b -2 11b -1 00b 0 01b 1 16.8 DEVICE IDENTIFICATION REGISTERS (3Eh-3Fh) 16.8.1 Register 3Eh Manufacturer ID Register Address Read/ Write Register Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value 3Eh R Manufacturer ID 0 0 0 0 0 0 0 0 01h The Manufacturer ID register contains the manufacturer identification number. This number is assigned by National Semiconductor and is a method for uniquely identifying the part manufacturer. 16.8.2 Register 3Fh Version/Stepping Register Address Read/ Write Register Name 3Fh R Version/Stepping Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 VER[3:0] 0 1 1 Bit 2 Bit 1 Bit 0 STP[3:0] 1 1 0 0 Default Value 79h 1 The four least significant bits of the Version/Stepping register [3:0] contain the current stepping of the LM96194 silicon. The four most significant bits [7:4] reflect the LM96194 version number. The LM96194 has a fixed version number of 0111b which matches the LM93, since the LM96194 is closely related to the LM93. To differentiat the LM96194 from the LM93 for the first stepping of LM96194 this register reads 01111000b. For the second stepping of the LM96194, this register reads 01111001b and so on. It is incrementally increased for future versions for the silicon. The final released silicon has a stepping of 9h therefore this register reads 79h. Since the LM96194 is so closely related to the LM94 the LM94 and LM96194 have the same VER and STP values. The register is used by application software to identify which device in the family of hardware monitoring ASICs has been implemented in the given system. Based on this information, software can determine which registers to read from and write to. Application software may use the current stepping to implement work-a-rounds for bugs found in a specific silicon stepping. 16.9 BMC ERROR STATUS REGISTERS 40h-47h The B_Error Status Registers contain several bits that each represent a particular error event that the LM96194 can monitor. The LM96194 sets a given bit whenever the corresponding error event occurs. The BMC_ERR bit in the LM96194 Status/Control register is also set if any bit in the BMC Error Status registers is set. If enabled, ALERT is also asserted anytime BMC_ERR is set. The exception to this is the fixed threshold error status bits in the PROCHOT Error Status registers. They have no influence on BMC_ERR or ALERT. www.national.com 48 If the LM96194 is in ASF mode, the BMC Error Status registers are both read-to-clear and write-one-to-clear. When not in ASF mode, the registers are only write-one-to-clear. Each register described in this section has a column labeled Sleep Masking. This column describes which error events are masked in various sleep states. The sleep state of the system is communicated to the LM96194 by writing to the Sleep State Control register. If a sleep state in this column has a `*' next to it, it denotes that the error event is optionally masked in that sleep mode, depending on the Sleep State Mask registers. 16.9.1 Register 40h B_Error Status 1 Register Address Read/ Write Register Name 40h RWC B_Error Status 1 Bit Name Bit 7 Bit 6 Bit 5 RES R/W Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value VRD _ERR ZN4_ ERR ZN3_ ERR ZN2_ ERR ZN1_ ERR 00h Description Sleep Masking 0 ZN1_ERR RWC This bit is set when any zone 1 temperature has fallen outside its associated temperature limits. S3*, S4/5* 1 ZN2_ERR RWC This bit is set when any zone 2 temperature has fallen outside its associated temperature limits. S3*, S4/5* 2 ZN3_ERR RWC This bit is set when the zone 3 temperature has fallen outside the zone 3 temperature limits. none 3 ZN4_ERR RWC This bit is set when the zone 4 temperature has fallen outside the zone 4 temperature limits. none 4 VRD_ERR RWC This bit is set when the VRD_HOT input has been asserted. 7:5 RES R Reserved S3, S4/5 N/A 49 www.national.com LM96194 Once a bit is set in the BMC Error Status registers, it is not automatically cleared by the LM96194 if the error event goes away. Each bit must be cleared by software. If software attempts to clear a bit while the error condition still exists, and the error is unmasked, the bit does not clear. If the error is masked, the bit can be cleared even if the error condition still exists. LM96194 16.9.2 Register 41h B_Error Status 2 Register Address Read/ Write Register Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value 41h RWC B_Error Status 2 RES ADIN4 _ERR RES RES RES ADIN3 _ERR ADIN2 _ERR ADIN1 _ERR 00h Bit Name R/W Sleep Masking Description 0 AD1_ERR RWC This bit is set when the AD_IN1 voltage has fallen outside the range defined by the AD_IN1 Low Limit and the AD_IN1 High Limit registers. S3, S4/5 1 AD2_ERR RWC This bit is set when the AD_IN2 voltage has fallen outside the range defined by the AD_IN2 Low Limit and the AD_IN2 High Limit registers. S3, S4/5 2 AD3_ERR RWC This bit is set when the AD_IN3 voltage has fallen outside the range defined by the AD_IN3 Low Limit and the AD_IN3 High Limit registers. S3, S4/5 3:5 RES RWC RESERVED 6 AD4_ERR RWC This bit is set when the AD_IN7 voltage has fallen outside the range defined by the AD_IN7 Low Limit and the AD_IN7 High Limit registers. 7 RES RWC RESERVED 16.9.3 Register 42h S3, S4/5 B_Error Status 3 Register Address Read/ Write Register Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value 42h RWC B_Error Status 3 ADIN9 _ERR ADIN8 _ERR ADIN7 _ERR ADIN6 _ERR RES RES RES ADIN5 _ERR 00h Bit 0 1:3 Name R/W Description AD5_ERR RWC This bit is set when the AD_IN9 voltage has fallen outside the range defined by the AD_IN9 Low Limit and the AD_IN9 High Limit registers. Sleep Masking S3, S4/5 RES RWC RESERVED 4 AD6_ERR RWC This bit is set when the AD_IN13 voltage has fallen outside the range defined by the AD_IN13 Low Limit and the AD_IN13 High Limit registers. S3*, S4/5* 5 AD7_ERR RWC This bit is set when the AD_IN14 voltage has fallen outside the range defined by the AD_IN14 Low Limit and the AD_IN14 High Limit registers. S3*, S4/5* 6 AD8_ERR RWC This bit is set when the AD_IN15 voltage has fallen outside the range defined by the AD_IN15 Low Limit and the AD_IN15 High Limit registers. S3, S4/5 7 AD9_ERR RWC This bit is set when the AD_IN16 voltage has fallen outside the range defined by the AD_IN16 Low Limit and the AD_IN16 High Limit registers. none www.national.com 50 B_Error Status 4 Register Address Read/ Write Register Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value 43h RWC B_Error Status 4 D2a_ ERR D1a_ ERR RES DVDDP1 _ERR GPI9 _ERR RES D2b _ERR D1b _ERR 00h Bit Name R/W Description Sleep Masking 0 D1b_ERR RWC Diode Fault Error This bit is set if there is an open or short circuit on the REMOTE1b+ and REMOTE1- pins. S3*, S4/5* 1 D2b_ERR RWC Diode Fault Error This bit is set if there is an open or short circuit on the REMOTE2b+ and REMOTE2- pins. S3*, S4/5* 2 RES RWC RESERVED 3 GPI8 RWC SCSI Fuse Error This bit is set if GPI8 has been asserted. Enabled only when VID mode is set to VRD 10. S3, S4/5 4 DVDDP_ERR RWC Dynamic Vccp Limit Error. This bit is set if AD_IN4 (Vccp) did not match the requested voltage as reported by P1_VID[7:0]. S3, S4/5 5 RES RWC RESERVED 6 D1a_ERR RWC Diode Fault Error This bit is set if there is an open or short circuit on the REMOTE1a+ and REMOTE1- pins. S3*, S4/5* 7 D2a_ERR RWC Diode Fault Error This bit is set if there is an open or short circuit on the REMOTE2a+ and REMOTE2- pins. S3*, S4/5* 51 www.national.com LM96194 16.9.4 Register 43h LM96194 16.9.5 Register 44h B_P_PROCHOT Error Status Register Address Read/ Write Register Name Bit 7 Bit 6 44h RWC B_P_PROCHOT Error Status PH _ERR TMAX Bit Name R/W Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value T100 T75 T50 T25 T12 T0 00h Description Sleep Masking 0 T0 RWC Set when PROCHOT has had a throttled event. This bit is set for any amount of PROCHOT throttling >0%. S3, S4/5 1 T12 RWC Set when PROCHOT has throttled greater than or equal to 0.39% but less than 12.5%. S3, S4/5 2 T25 RWC Set when PROCHOT has throttled greater than or equal to 12.5% but less than 25%. S3, S4/5 3 T50 RWC Set when PROCHOT has throttled greater than or equal to 25% but less than 50%. S3, S4/5 4 T75 RWC Set when PROCHOT has throttled greater than or equal to 50% but less than 75%. S3, S4/5 5 T100 RWC Set when PROCHOT has throttled greater than or equal to 75% but less than 100%. S3, S4/5 6 TMAX RWC Set when PROCHOT has throttled 100%. S3, S4/5 7 PH_ERR RWC Set when PROCHOT has throttled more than the user limit. S3, S4/5 The PH1_ERR bit is the only bit in this register that will set BMC_ ERR in the LM96194 Status/Control register. www.national.com 52 B_GPI Error Status Register Address Read/ Write Register Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value 46h RWC B_GPI Error Status GPI7 _ERR GPI6 _ERR GPI5 _ERR GPI4 _ERR GPI3 _ERR GPI2 _ERR GPI1 _ERR GPI0 _ERR 00h Bit Name R/W Description Sleep Masking 0 GPI0_ERR RWC This bit is set whenever GPIO0 is driven low (unless masked via the GPI Error Mask register). S1*, S3*, S4/5* 1 GPI1_ERR RWC This bit is set whenever GPIO1 is driven low (unless masked via the GPI Error Mask register). S1*, S3*, S4/5* 2 GPI2_ERR RWC This bit is set whenever GPIO2 is driven low (unless masked via the GPI Error Mask register). S1*, S3*, S4/5* 3 GPI3_ERR RWC This bit is set whenever GPIO3 is driven low (unless masked via the GPI Error Mask register). S1*, S3*, S4/5* 4 GPI4_ERR RWC This bit is set whenever GPIO4 is driven low (unless masked via the GPI Error Mask register). S1*, S3*, S4/5* 5 GPI5_ERR RWC This bit is set whenever GPIO5 is driven low (unless masked via the GPI Error Mask register). S1*, S3*, S4/5* 6 GPI6_ERR RWC This bit is set whenever GPIO6 is driven low (unless masked via the GPI Error Mask register). S1*, S3*, S4/5* 7 GPI7_ERR RWC This bit is set whenever GPIO7 is driven low (unless masked via the GPI Error Mask register). S1*, S3*, S4/5* 53 www.national.com LM96194 16.9.6 Register 46h LM96194 16.9.7 Register 47h B_Fan Error Status Register Address Read/ Write Register Name 47h RWC B_Fan Error Status Bit Name Bit 7 Bit 6 Bit 5 Bit 4 RES R/W Bit 3 Bit 2 Bit 1 Bit 0 Default Value FAN4 _ERR FAN3 _ERR FAN2 _ERR FAN1 _ERR 00h Sleep Masking Description 0 FAN1_ERR RWC This bit is set when the Fan Tach 1 value register is above the value set in the Fan Tach 1 Limit register. S1*, S3*, S4/5 1 FAN2_ERR RWC This bit is set when the Fan Tach 2 value register is above the value set in the Fan Tach 2 Limit register. S1*, S3*, S4/5 2 FAN3_ERR RWC This bit is set when the Fan Tach 3 value register is above the value set in the Fan Tach 3 Limit register. S1*, S3*, S4/5 3 FAN4_ERR RWC This bit is set when the Fan Tach 4 value register is above the value set in the Fan Tach 4 Limit register. S1*, S3*, S4/5 7:4 RES R Reserved N/A 16.10 HOST ERROR STATUS REGISTERS The Host Error Status Registers contain several bits that each represent a particular error event that the LM96194 can monitor. The LM96194 sets a given bit whenever the corresponding error event occurs. The HOST_ERR bit in the LM96194 Status/Control register also sets if any bit in the Host Error Status registers is set. The exception to this is the fixed threshold error status bits in the PROCHOT Error Status registers. They have no influence on HOST_ERR. Once a bit is set in the Host Error Status registers, it is not automatically cleared by the LM96194 if the error event goes away. Each bit must be cleared by software. If software attempts to clear a bit while the error condition still exists, the bit does not clear. Software must specifically write a 1 to any bits it wishes to clear in the Host Error Status registers (write-one-to-clear). Each register described in this section has a column labeled Sleep Masking. This column describes which error events are masked in various sleep states. The sleep state of the system is communicated to the LM96194 by writing to the Sleep State Control register. If a sleep state in this column has a `*' next to it, it denotes that the error event is optionally masked in that sleep mode, depending on the Sleep State Mask registers. 16.10.1 Register 48h H_Error Status 1 Register Address Read/ Write Register Name 48h RWC H_Error Status 1 Bit Name Bit 7 Bit 6 Bit 5 RES R/W Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value VRD _ERR ZN4_ ERR ZN3_ ERR ZN2_ ERR ZN1_ ERR 00h Description Sleep Masking 0 ZN1_ERR RWC This bit is set when any zone 1 temperature has fallen outside its associated temperature limits. S3*, S4/5* 1 ZN2_ERR RWC This bit is set when any zone 2 temperature has fallen outside its associated temperature limits. S3*, S4/5* 2 ZN3_ERR RWC This bit is set when the zone 3 temperature has fallen outside the zone 3 temperature limits. none 3 ZN4_ERR RWC This bit is set when the zone 4 temperature has fallen outside the zone 4 temperature limits. none 4 VRD_ERR RWC This bit is set when the VRD_HOT input has been asserted. 7:5 RES www.national.com R Reserved S3, S4/5 N/A 54 H_Error Status 2 Register Address Read/ Write Register Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value 49h RWC H_Error Status 2 RES ADIN4 _ERR RES RES RES ADIN3 _ERR ADIN2 _ERR ADIN1 _ERR 00h Bit Name R/W Description Sleep Masking 0 AD1_ERR RWC This bit is set when the AD_IN1 voltage has fallen outside the range defined by the AD_IN1 Low Limit and the AD_IN1 High Limit registers. S3, S4/5 1 AD2_ERR RWC This bit is set when the AD_IN2 voltage has fallen outside the range defined by the AD_IN2 Low Limit and the AD_IN2 High Limit registers. S3, S4/5 2 AD3_ERR RWC This bit is set when the AD_IN3 voltage has fallen outside the range defined by the AD_IN3 Low Limit and the AD_IN3 High Limit registers. S3, S4/5 35 RES RWC RESERVED 6 AD4_ERR RWC This bit is set when the AD_IN4 voltage has fallen outside the range defined by the AD_IN4 Low Limit and the AD_IN4 High Limit registers. 7 RES RWC RESERVED 55 S3, S4/5 www.national.com LM96194 16.10.2 Register 49h LM96194 16.10.3 Register 4Ah H_Error Status 3 Register Address Read/ Write Register Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value 4Ah RWC H_Error Status 3 ADIN9 _ERR ADIN8 _ERR ADIN7 _ERR ADIN6 _ERR RES RES RES ADIN5 _ERR 00h Bit 0 1:3 Name R/W Description AD5_ERR RWC This bit is set when the AD_IN5 voltage has fallen outside the range defined by the AD_IN5 Low Limit and the AD_IN5 High Limit registers. Sleep Masking S3, S4/5 RES RWC RESERVED 4 AD6_ERR RWC This bit is set when the AD_IN13 voltage has fallen outside the range defined by the AD_IN13 Low Limit and the AD_IN13 High Limit registers. S3*, S4/5* 5 AD7_ERR RWC This bit is set when the AD_IN14 voltage has fallen outside the range defined by the AD_IN14 Low Limit and the AD_IN14 High Limit registers. S3*, S4/5* 6 AD8_ERR RWC This bit is set when the AD_IN15 voltage has fallen outside the range defined by the AD_IN15 Low Limit and the AD_IN15 High Limit registers. S3, S4/5 7 AD9_ERR RWC This bit is set when the AD_IN16 voltage has fallen outside the range defined by the AD_IN16 Low Limit and the AD_IN16 High Limit registers. none www.national.com 56 Register Address Read/ Write Register Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value 4Bh RWC H_Error Status 4 D2a_ ERR D1a_ ERR RES DVDDP _ERR GPI8 _ERR RES D2b _ERR D1b _ERR 00h Bit Name R/W Description Sleep Masking 0 D1b_ERR RWC Diode Fault Error This bit is set if there is an open or short circuit on the REMOTE1b+ and REMOTE1- pins. S3*, S4/5* 1 D2b_ERR RWC Diode Fault Error This bit is set if there is an open or short circuit on the REMOTE2b+ and REMOTE2- pins. S3*, S4/5* 2 RES RWC RESERVED S3, S4/5 3 GPI8 RWC SCSI Fuse Error This bit is set if GPI8 has been asserted. Enabled only when VID mode is set to VRD 10. S3, S4/5 4 DVDDP_ERR RWC Dynamic Vccp Limit Error. This bit is set if AD_IN7 (P1_Vccp) did not match the requested voltage as reported by P1_VID[7:0]. S3, S4/5 5 RES RWC RES 6 D1a_ERR RWC Diode Fault Error This bit is set if there is an open or short circuit on the REMOTE1a+ and REMOTE1- pins. S3*, S4/5* 7 D2a_ERR RWC Diode Fault Error This bit is set if there is an open or short circuit on the REMOTE2a+ and REMOTE2- pins. S3*, S4/5* S3, S4/5 57 www.national.com LM96194 16.10.4 Register 4Bh H_Error Status 4 LM96194 16.10.5 Register 4Ch H_P_PROCHOT Error Status Register Address Read/ Write Register Name Bit 7 4Ch RWC H_P_PROCHOT Error Status PH_ERR Bit Name Bit 6 TMAX R/W Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value T100 T75 T50 T25 T12 T0 00h Description Sleep Masking 0 T0 RWC Set when PROCHOT has had a throttled event. This bit is set for any amount of PROCHOT throttling >0%. S3, S4/5 1 T12 RWC Set when PROCHOT has throttled greater than or equal to 0.00% but less than 12.5%. S3, S4/5 2 T25 RWC Set when PROCHOT has throttled greater than or equal to 12.5% but less than 25%. S3, S4/5 3 T50 RWC Set when PROCHOT has throttled greater than or equal to 25% but less than 50%. S3, S4/5 4 T75 RWC Set when PROCHOT has throttled greater than or equal to 50% but less than 75%. S3, S4/5 5 T100 RWC Set when PROCHOT has throttled greater than or equal to 75% but less than 100%. S3, S4/5 6 TMAX RWC Set when PROCHOT has throttled 100%. S3, S4/5 7 PH_ERR RWC Set when PROCHOT has throttled more than the user limit. S3, S4/5 The PH1_ERR bit is the only bit in this register that will set HOST_ ERR in the LM96194 Status/Control register. www.national.com 58 H_GPI Error Status Register Address Read/ Write Register Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value 4Eh RWC H_GPI Error Status GPI7 _ERR GPI6 _ERR GPI5 _ERR GPI4 _ERR GPI3 _ERR GPI2 _ERR GPI1 _ERR GPI0 _ERR 00h Bit Name R/W Description Sleep Masking 0 GPI0_ERR RWC This bit is set whenever GPIO0 is driven low (unless masked via the GPI Error Mask register). S1*, S3*, S4/5* 1 GPI1_ERR RWC This bit is set whenever GPIO1 is driven low (unless masked via the GPI Error Mask register). S1*, S3*, S4/5* 2 GPI2_ERR RWC This bit is set whenever GPIO2 is driven low (unless masked via the GPI Error Mask register). S1*, S3*, S4/5* 3 GPI3_ERR RWC This bit is set whenever GPIO3 is driven low (unless masked via the GPI Error Mask register). S1*, S3*, S4/5* 4 GPI4_ERR RWC This bit is set whenever GPIO4 is driven low (unless masked via the GPI Error Mask register). S1*, S3*, S4/5* 5 GPI5_ERR RWC This bit is set whenever GPIO5 is driven low (unless masked via the GPI Error Mask register). S1*, S3*, S4/5* 6 GPI6_ERR RWC This bit is set whenever GPIO6 is driven low (unless masked via the GPI Error Mask register). S1*, S3*, S4/5* 7 GPI7_ERR RWC This bit is set whenever GPIO7 is driven low (unless masked via the GPI Error Mask register). S1*, S3*, S4/5* 59 www.national.com LM96194 16.10.6 Register 4Eh LM96194 16.10.7 Register 4Fh H_Fan Error Status Register Address Read/ Write Register Name 4Fh RWC H_Fan Error Status Bit Name Bit 7 Bit 6 Bit 5 RES R/W Bit 3 Bit 2 Bit 1 Bit 0 Default Value FAN4 _ERR FAN3 _ERR FAN2 _ERR FAN1 _ERR 00h Bit 4 Sleep Masking Description 0 FAN1_ERR RWC This bit is set when the Fan Tach 1 value register is above the value set in the Fan Tach 1 Limit register. S1*, S3*, S4/5 1 FAN2_ERR RWC This bit is set when the Fan Tach 2 value register is above the value set in the Fan Tach 2 Limit register. S1*, S3*, S4/5 2 FAN3_ERR RWC This bit is set when the Fan Tach 3 value register is above the value set in the Fan Tach 3 Limit register. S1*, S3*, S4/5 3 FAN4_ERR RWC This bit is set when the Fan Tach 4 value register is above the value set in the Fan Tach 4 Limit register. S1*, S3*, S4/5 7:4 RES R Reserved N/A 16.11 VALUE REGISTERS 16.11.1 Registers 50-53h Register Address Read/ Write 06h 07h Unfiltered Temperature Value Registers Register Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value R Zone 1b (CPU) Temp 7 6 5 4 3 2 1 0 00h R Zone 2b (MMBT3904) Temp 7 6 5 4 3 2 1 0 00h 50h R Zone 1a (CPU) Temp 7 6 5 4 3 2 1 0 00h 51h R Zone 2a (MMBT3904) Temp 7 6 5 4 3 2 1 0 00h 52h R Zone 3 (Internal) Temp 7 6 5 4 3 2 1 0 00h R/W Zone 4 (External Digital) Temp 7 6 5 4 3 2 1 0 00h 53h Zones 1 and 2 are all automatically updated by the LM96194. The Zone 4 (External Digital) Temp registers may be written by an external SMBus device or can be assigned to AD_IN8. The temperature registers for zones 1 and 2 will return a value of 80h if the remote diode pins are not implemented by the board designer or are not functioning properly. 16.11.2 Registers 54-55h Filtered Temperature Value Registers Register Address Read/ Write Register Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value 08h R Zone 1b (CPU) Filtered Temp 7 6 5 4 3 2 1 0 00h 09h R Zone 2b (MMBT3904) Filtered Temp 7 6 5 4 3 2 1 0 00h 54h R Zone 1a (CPU) Filtered Temp 7 6 5 4 3 2 1 0 00h 55h R Zone 2a (MMBT3904) Filtered Temp 7 6 5 4 3 2 1 0 00h These registers reflect the temperature of zones 1 and 2 after the spike smoothing filter has been applied. The characteristics of the filtering can be adjusted by using the Zones 1/2 Spike Smoothing Control register. www.national.com 60 A/D Channel Voltage Registers Register Address Read/ Write Register Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value 56h R AD_IN1 Voltage 7 6 5 4 3 2 1 0 N/D 57h R AD_IN2 Voltage 7 6 5 4 3 2 1 0 N/D 58h R AD_IN3 Voltage 7 6 5 4 3 2 1 0 N/D 5Ch R AD_IN4 Voltage 7 6 5 4 3 2 1 0 N/D 5Eh R AD_IN5 Voltage 7 6 5 4 3 2 1 0 N/D 62h R AD_IN6 Voltage 7 6 5 4 3 2 1 0 N/D 63h R AD_IN7 Voltage 7 6 5 4 3 2 1 0 N/D 64h R AD_IN8 Voltage 7 6 5 4 3 2 1 0 N/D 65h R AD_IN9 Voltage 7 6 5 4 3 2 1 0 N/D The voltage reading registers reflect the current voltage of the LM96194 voltage monitoring inputs. Voltages are presented in the registers at 3/4 full scale for the nominal voltage. Therefore, at nominal voltage, each register reads C0h. 16.11.4 Register 67h Current PROCHOT Register Address Read/ Write Register Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value 67h R Current PROCHOT 7 6 5 4 3 2 1 0 00h This is the value of the PROCHOT percentage active time for Processor at the end of each PROCHOT monitoring interval as set by the PROCHOT Time Interval register. Writing to this register does not effect the register contents, but does restart the capture cycle for PROCHOT. A register value of one represents anything greater than 0% but less than 0.39% of active time. Register Value (Decimal) Percentage Active Time 0 0% 1 0.39% 2 0.78% * * * n * * * n/256*100 255 99.60% 61 www.national.com LM96194 16.11.3 Register 56-65h LM96194 16.11.5 Register 68h Average PROCHOT Register Address Read/ Write Register Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value 68h R Average PROCHOT 7 6 5 4 3 2 1 0 00h This is the average percentage active time of PROCHOT. It is the result of adding the contents of this register to the contents of the Current PROCHOT register and dividing the result by 2. The update occurs at the same time that the Current PROCHOT register gets updated. A register value of one represents anything greater than 0% but less than 0.39% of active time. 16.11.6 Register 6Bh Current GPI State Register Address Read/ Write Register Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value 6Bh R GPI State GPI7 GPI6 GP15 GPI4 GPI3 GPI2 GPI1 GPI0 00h www.national.com Bit Name Read/Write 0 GPI0 R 1 if GPIO_0 input is LOW, not latched Description 1 GPI1 R 1 if GPIO_1 input is LOW, not latched 2 GPI2 R 1 if GPIO_2 input is LOW, not latched 3 GPI3 R 1 if GPIO_3 input is LOW, not latched 4 GPI4 R 1 if GPIO_4 input is LOW, not latched 5 GPI5 R 1 if GPIO_5 input is LOW, not latched 6 GPI6 R 1 if GPIO_6 input is LOW, not latched 7 GPI7 R 1 if GPIO_7 input is LOW, not latched 62 This register has four possible mappings described in the table. The mapping is determined by the VID mode as selected in the Special Function Control 2 register at address BDh. See the Special Function Control 2 register description for further details. Register Address Read/ Write Register Name Bit 7 Bit 6 Bit 5 RES (0) 6Ch R VID Bit 4 Bit 3 Bit 2 Bit 1 Default Value Bit 0 VID[5:0] for VRD 10 mode (functions same as LM93) RES (0) VID[6:0] for VRD 10.2 Extended mode RES (0) VID[6:0] for VRD 11 , Mode 1 (most commonly used mode for VRD11) VID[7:1] for VRD 11, Mode 2 00h 00h 00h RES (0) 00h VRD 10 mode Bit Name Read/Write 5:0 VID[5:0] R Processor VID status. Reports the current state of the P1_VID5 through P1_VID0 pins. This register will only be updated if P1_VID signals remain stable for at least 600 ns. Description 7:6 RES R Reserved and will always report 0. VRD 10.2 Extended mode Bit Name Read/Write Description 6:0 VID[6:0] R Processor VID status. Reports the current state of the VID6 through VID0 pins. This register will only be updated if VID signals remain stable for at least 600 ns. 7 RES R Reserved and will always report 0. VRD 11 Mode 1 Bit Name Read/Write Description 6:0 VID[6:0] R Processor VID status. This mode is the recommended mode for support of VRD11. Reports the current state of the VID6 through VID0 pins. This register will only be updated if VID signals remain stable for at least 600 ns. 7 RES R Reserved and will always report 0. VRD 11 Mode 2 Bit Name Read/Write 0 RES R Reserved and will always report 0. Description 7:1 VID[7:1] R Processor VID status. This mode is supplied for future experimentation and will require additional hardware in order to support both VRD11 and VRD10 specifications. Reports the current state of the VID7 through VID1 pins. This register will only be updated if VID signals remain stable for at least 600 ns. 63 www.national.com LM96194 16.11.7 Register 6Ch VID LM96194 16.11.8 Register 6E-75h Fan Tachometer Readings Register Address Read/ Write Register Name 6Eh R Fan Tach 1 LSB 6Fh R Fan Tach 1 MSB 70h R Fan Tach 2 LSB 71h R Fan Tach 2 MSB 72h R Fan Tach 3 LSB 73h R Fan Tach 3 MSB 74h R Fan Tach 4 LSB 75h R Fan Tach 4 MSB Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 TACH1[5:0] Bit 0 T1ST[1:0] TACH1[13:6] TACH2[5:0] T2ST[1:0] TACH4[13:6] 00h 00h T3ST[1:0] TACH3[13:6] TACH4[5:0] 00h 00h TACH2[13:6] TACH3[5:0] Default Value 00h 00h T4ST[1:0] 00h 00h The 14-bit fan tach readings indicate the number of 22.5 kHz clock periods that occurred during two full periods of the tachometer input signal. Most fans produce two tachometer pulses per full revolution. These registers must be updated at least once every second. The fan tachometer reading registers must always return an accurate fan tachometer measurement, even when a fan is disabled or non-functional. 3FFFh indicates that the fan is stalled, not spinning fast enough to measure, or the tachometer input is not connected to a valid signal. If the pulses per revolution of the fan is known, the RPM can be calculated with the following equation: RPM= 22500 cycles/sec * 60 sec/min * 2 pulses / COUNT cycles / PULSES_PER_REV where: PULSES_PER_REV COUNT = the number of pulses that the fan produces per revolution = The 14-bit value read from the tach register Bit Name Read/Write 1:0 T1ST[1:0], T2ST[1:0], T3ST[1:0], T4ST[1:0] R Description Two bits for each tachometer reading that report the state of the fan control circuitry used to acquire a reading. See table below for further clarification. 7:2 TACH1[5:0], TACH2[5:0], TACH3[5:0], TACH4[5:0] R Least significant bit field of tachometer reading. 7:0 TACH1[13:6], TACH2[13:6], TACH3[13:6], TACH4[13:6] R Most significant bit fielf of tachometer reading. T1ST[1:0], T2ST[1:0], T3ST[1:0], or T4ST[1:0] www.national.com State of Fan Control Circuitry 00 Normal Mode (Smart Tach Mode disabled) 01 Reserved 10 Smart Tach Mode 1, less accurate with most stable Fan RPM 11 Smart Tach Mode 2, most accurate with least stable Fan RPM 64 LM96194 16.12 LIMIT REGISTERS 16.12.1 Registers 78-7Fh Temperature Limit Registers Register Address Read/ Write Register Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value 78h R/W Processor 1 (Zone1) Low Temp 7 6 5 4 3 2 1 0 80h 79h R/W Processor 1 (Zone1) High Temp 7 6 5 4 3 2 1 0 80h 7Ah R/W MMBT3904 (Zone2) Low Temp 7 6 5 4 3 2 1 0 80h 7Bh R/W MMBT3904 (Zone2) High Temp 7 6 5 4 3 2 1 0 80h 7Ch R/W Internal (Zone3) Low Temp 7 6 5 4 3 2 1 0 80h 7Dh R/W Internal (Zone3) High Temp 7 6 5 4 3 2 1 0 80h 7Eh R/W External Digital (Zone4) Low Temp 7 6 5 4 3 2 1 0 80h 7Fh R/W External Digital (Zone4) High Temp 7 6 5 4 3 2 1 0 80h If an external temperature input or the internal temperature sensor either exceeds the value set in the high limit register or falls below the value set in the low limit register, the corresponding bit in the B_ and H_Error Status 1 register is set automatically by the LM96194. For example, if the temperature read from the Remote1- and Remote1+ inputs exceeds the Processor (Zone1) High Temp register limit setting, the ZN1_ERR bit in both B_Error Status 1 and H_Error Status 1 registers is set. The temperature limits in these registers is represented as 8 bit, 2's complement, signed numbers in Celsius. If any high temp limit register is set to 80h then the B_ and H_Error Status register bit for that temperature channel is masked. 16.12.2 Registers 80-83h Fan Boost Temperature Registers Register Address Read/ Write Register Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value 80h R/W Fan Boost Temp Zone 1 7 6 5 4 3 2 1 0 3Ch 81h R/W Fan Boost Temp Zone 2 7 6 5 4 3 2 1 0 3Ch 82h R/W Fan Boost Temp Zone 3 7 6 5 4 3 2 1 0 23h 83h R/W Fan Boost Temp Zone 4 7 6 5 4 3 2 1 0 23h If any thermal zone exceeds the temperature set in the Fan Boost Limit register, both of the PWM outputs are set to 100%. The fan boost function takes precedence over low-resolution manual override. High-resolution manual overide takes priority over the fan boost function. This is a safety feature that attempts to cool the system if there is a potentially catastrophic thermal event. If set to 7Fh and the fan control temperature resolution is 1C, the feature is disabled. Default = 60C = 3Ch for zones 1 and 2 Default = 35C = 23h for zones 3 and 4 The temperature has to fall the number of degrees specified in the Fan Boost Hysteresis registers, below this temperature to cause the PWM outputs to return to normal operation. The fan boost function can be disabled by setting the associated register to 80h. 65 www.national.com LM96194 16.12.3 Register 84h Zone1, and Zone2 Hysteresis for Limit Comparisons Register Address Read/ Write Register Name 84h R/W Limit Comparison Hysteresis (Zones 1/2) Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value HC1 HC2 00h Bit Name R/W Description 3:0 HC1 R/W Sets the limit comparison hysteresis for zone 1 for both the High and Low limits. The hysteresis can be set from 0C to 15C and has 1C resolution. 7:4 HC2 R/W Sets the limit comparison hysteresis for zone 2 for both the High and Low limits. The hysteresis can be set from 0C to 15C and has 1C resolution. 16.12.4 Register 85h Zone3 and Zone4 Hysteresis for Limit Comparisons Register Address Read/ Write Register Name 85h R/W Limit Comparison Hysteresis (Zones 3/4) Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value HC3 HC4 00h Bit Name R/W Description 3:0 HC3 R/W Sets the limit comparison hysteresis for zone 3 for both the High and Low limits. The hysteresis can be set from 0C to 15C and has 1C resolution. 7:4 HC4 R/W Sets the limit comparison hysteresis for zone 4 for both the High and Low limits.The hysteresis can be set from 0C to 15C and has 1C resolution. 16.12.5 Registers 8E-8Fh Zone 1b and Zone 2b Temperature Reading Adjustment Registers Register Address Read/ Write Register Name Bit 7 Bit 6 8Eh R/W Zone 1b Temp Adjust RES RES Z1b_ADJUST[5:0] 00h 8Fh R/W Zone 2b Temp Adjust RES RES Z2b_ADJUST[5:0] 00h Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value Bit Name R/W Description 5:0 Z1b_ADJUST[5:0] or Z2b_ADJUST[5:0] R/W 6-bit signed 2's complement offset adjustment. This value is added to zone 1b or zone 2b temperature measurements as they are made. All LM96194 registers and functions behave as if the resulting temperature was the true measured temperature. This register allows offset adjustments from +31C to -32C in 1C steps. 7:6 RES R www.national.com 66 Reserved Register Address Read/ Write 90h 91h 92h 93h Voltage Limit Registers Register Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value R/W AD_IN1 Low Limit 7 6 5 4 3 2 1 0 00h R/W AD_IN1 High Limit 7 6 5 4 3 2 1 0 FFh R/W AD_IN2 Low Limit 7 6 5 4 3 2 1 0 00h R/W AD_IN2 High Limit 7 6 5 4 3 2 1 0 FFh 94h R/W AD_IN3 Low Limit 7 6 5 4 3 2 1 0 00h FFh 95h R/W AD_IN3 High Limit 7 6 5 4 3 2 1 0 9Ch R/W AD_IN4 Low Limit 7 6 5 4 3 2 1 0 00h 9Dh R/W AD_IN4 High Limit 7 6 5 4 3 2 1 0 FFh A0h R/W AD_IN5 Low Limit 7 6 5 4 3 2 1 0 00h A1h R/W AD_IN5 High Limit 7 6 5 4 3 2 1 0 FFh A8h R/W AD_IN6 Low Limit 7 6 5 4 3 2 1 0 00h A9h R/W AD_IN6 High Limit 7 6 5 4 3 2 1 0 FFh AAh R/W AD_IN7 Low Limit 7 6 5 4 3 2 1 0 00h ABh R/W AD_IN7 High Limit 7 6 5 4 3 2 1 0 FFh ACh R/W AD_IN8 Low Limit 7 6 5 4 3 2 1 0 00h ADh R/W AD_IN8 High Limit 7 6 5 4 3 2 1 0 FFh AEh R/W AD_IN9 Low Limit 7 6 5 4 3 2 1 0 00h AFh R/W AD_IN9 High Limit 7 6 5 4 3 2 1 0 FFh FFh as the high limit acts as a mask for that voltage sensor and so prevents this channel from being able to set the associated error status bit in the B_ or H_ Error Status registers, for both high and low limit errors. If a voltage input either exceeds the value set in the voltage high limit register or falls below the value set in the voltage low limit register, the corresponding bit is set automatically by the LM96194 in the B_ and H_Error Status registers. 67 www.national.com LM96194 16.12.6 Registers 90-AFh LM96194 16.12.7 Register B0h PROCHOT User Limit Register Register Address Read/ Write Register Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value B0h R/W PROCHOT User Limit 7 6 5 4 3 2 1 0 FFh These registers allow a user limit to be set for the PROCHOT monitoring function. If the corresponding Current Px_PROCHOT register exceeds this value, the PH1_ERR or PH2_ERR bit is set in the corresponding Host and BMC error status registers. A value of FFh acts as a mask and prevents the error status bits from being set. Register Value (Decimal) www.national.com Threshold Percentage 0 0% 1 0.39% 2 0.78% * * * n * * * n/256*100 255 99.60% 68 Register Address Read/ Write Register Name B2h R/W Vccp Limit Offsets Bit 7 Bit 6 Bit 5 Bit 4 UPPER_OFFSET1 Bit 3 Bit 2 Bit 1 LOWER_OFFSET1 Bit 0 Default Value 17h These offsets are used to determine the upper and lower limits of the dynamic Vccp window comparator. These offsets are added or subtracted from the value selected by the VID bits. LOWER_OFFSET1 or LOWER_OFFSET2 Lower Offset 0h 25 mV 1h 50 mV 2h 75 mV 3h 100 mV ... ... Ch 325 mV Dh 350 mV Eh 375 mV Fh 400 mV UPPER_OFFSET1 or UPPER_OFFSET2 Upper Offset 0h 12.5 mV 1h 25 mV 2h 37.5 mV 3h 50 mV ... ... Dh 175 mV Eh 187.5 mV Fh 200 mV 69 www.national.com LM96194 16.12.8 Register B2h Dynamic Vccp Limit Offset Register LM96194 16.12.9 Register B4-BBh Fan Tach Limit Registers Register Address Read/ Write Register Name B4h R/W Fan Tach 1 Limit LSB B5h R/W Fan Tach 1 Limit MSB B6h R/W Fan Tach 2 Limit LSB B7h R/W Fan Tach 2 Limit MSB B8h R/W Fan Tach 3 Limit LSB B9h R/W Fan Tach 3 Limit MSB BAh R/W Fan Tach 4 Limit LSB BBh R/W Fan Tach 4 Limit MSB Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 TLIMIT1[5:0] Bit 2 Bit 1 Bit 0 RES TLIMIT1[13:6] TLIMIT2[5:0] RES TLIMIT4[13:6] FCh FFh RES TLIMIT1[13:6] TLIMIT4[5:0] FCh FFh TLIMIT2[13:6] TLIMIT3[5:0] Default Value FCh FFh RES FCh FFh If a tachometer reading exceeds its limit (as defined by these registers) the corresponding bit is set in the Host and BMC Error Status registers. The fan tachometer readings can be associated with a particular PWM output, but the tach errors are not automatically masked when a PWM is at 0% or set to level that causes the fan RPM to be below the limit purposely. In order to prevent false errors, care needs to be taken to make sure that the Fan Tach Limits are properly set. Errors are never generated for a fan if its limit is set to 3FFFh. www.national.com 70 LM96194 16.13 SETUP REGISTERS 16.13.1 Register BCh Special Function Control 1 (Voltage Hysteresis and Fan Control Filter Enable) Register Address Read/ Write Register Name Bit 7 BCh R/W Special Function Control 1 RES Bit 6 FCFE2 Bit 5 FCFE1 Bit 4 Bit 3 LCFE2 LCFE1 Bit 2 Bit 1 VH Bit 0 Default Value 00h Bit Name R/W Description 2:0 VH R/W Voltage hysteresis control. This determines the amount of hysteresis to be applied to all voltage limit comparisons. It applies to both high and low limits. One LSB equals one A/D count, so the actual voltage represented by one LSB depends on the voltage channel. 3 LCFE1 R/W Limit Comparison Filter Enable. Setting this bit causes limit comparisons for temperature zone 1a and 1b to use the filtered (spike smoothed) temperature instead of the unfiltered temperature. 4 LCFE2 R/W Limit Comparison Filter Enable. Setting this bit causes limit comparisons for temperature zone 2a and 2b to use the filtered (spike smoothed) temperature instead of the unfiltered temperature. 5 FCFE1 R/W Fan Control Filter Enable. Setting this bit causes fan control functions for zone 1a and 1b (including fan boost) to use the filtered (spike smoothed) temperature instead of the unfiltered temperature. This includes the PI Loop controller, LUT, and temperature fan boost functions. 6 FCFE2 R/W Fan Control Filter Enable. Setting this bit causes fan control functions for zone 2a and 2b (including fan boost) to use the filtered (spike smoothed) temperature instead of the unfiltered temperature. This includes the PI Loop controller, LUT, and temperature fan boost functions. 7 RES R Reserved In order for the LCFE1, LCFE2, FCFE1 and FCFE2 bits to work correctly, the ZN1E and ZN2E bits in the Zones 1/2 Spike Smoothing Control register (at address C2h) should be cleared. Application Note: If hysteresis for voltage limit comparisons is non-zero, special care needs to be taken when changing the voltage limit registers while a voltage error condition exists. If software relaxes the voltage limits in an attempt to prevent an error condition, it may be necessary to relax the limits by an amount greater than the hysteresis value and wait several milliseconds before attempting to clear the error status bit for the given voltage channel. Once the error status bit has been cleared, the desired limit(s) can be programmed. 71 www.national.com LM96194 16.13.2 Register BDh Special Function Control 2 (Smart Tach Mode Enable, Fan Control Temperature Resolution Control and VID Mode Select) Register Address Read/ Write Register Name BDh R/W Special Function Control 2 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 VID_MODE[1:0] LT34 _RS LT12 _RS STE4 STE3 STE2 STE1 Bit Name R/W 0 STE1 R/W Enable Smart Tach for Tach 1 1 STE2 R/W Enable Smart Tach for Tach 2 2 STE3 R/W Enable Smart Tach for Tach 3 3 STE4 R/W Enable Smart Tach for Tach 4 4 LT12_RS R/W When this bit is set, the LUT1 and LUT2 fan controls will use 0.5C. The resolution of the LUT offsets and hysteresis settings are affected by this bit. These bits apply to the fan control offset registers, fan control hysteresis registers, and boost hysteresis registers. 5 LT34_RS R/W When this bit is set, the LUT3 and LUT4 fan controls will use 0.5C. The resolution of the LUT offsets and hysteresis settings are affected by this bit. 7:6 VID_MODE [1:0] R/W These bits select the VID mode which determines how the VID code is handled by the VID value registers and the dynamic Vccp monitoring. 7 RES R Default Value 00h Description Reserved VID Mode Select Bit Description VID_MODE[1:0] VID Mode 00 VRD10 Comments Supports the VRD10 specification from Intel and is backwards compatible with the LM93 dynamic Vccp monitoring circuitry. This mode has a voltage range of 0.8375V to 1.600V with 12.5mV resolution and supports 6 VID bits/ pins. 01 VRD10.2 Extended Supports the VRD10.2 Extended specification from Intel. This mode has a voltage range of 0.83125V to 1.600V with 6.25mV resolution and supports 7 VID bits/pins. 10 VRD11 Mode 1 Supports the VRD11 specification from Intel. This mode has a voltage range of 0.83125V to 1.600V with 6.25mV resolution and supports 7 VID bits/pins (VID6-VID0). It assumes VID7 is 0. This is the recommended mode of operation for support of VRD10 and VRD11 without requiring additional hardware. 11 VRD11 Mode 2 Supports the VRD11 specification from Intel. This mode has a voltage range of 0.0375V to 1.600V with 12.5mV resolution and supports 7 VID bits/pins (VID7-VID1). It assumes VID0 is 0. This mode measures voltage levels below 0.83125V for VRD11, but will require additional hardware to simultaneously support VRD10 operation. Application Note: Enabling Smart Tach mode is not supported while either PWM output is configured for 22.5 kHz. The behavior of the part is undefined if this configuration is programmed. Register E0h Special Function TACH to PWM Binding must be setup when Smart Tach modes are enabled. www.national.com 72 Register Address Read/ Write Register Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value BEh R/W GPI/VID Level Control GPI7 _LVL GPI6 _LVL GPI5 _LVL GPI4 _LVL GPI9 _LVL GPI8 _LVL RES P1_VID _LVL 00h Bit Name R/W 0 P1_VID_LVL R/W If set, P1_VIDx inputs use alternate lower VIH and VIL levels. 1 RES R/W RES 2 GPI8_LVL R/W When in VRD10 mode, if set, GPI_8 input uses alternate lower VIH and VIL levels. 3 GPI9_LVL R/W When in VRD10 mode, if set, GPI_9 input will use alternate lower VIH and VIL levels. 4 GPI4_LVL R/W If set, GPIO4 input will use alternate lower VIH and VIL levels 5 GPI5_LVL R/W If set, GPIO5 input will use alternate lower VIH and VIL levels 6 GPI6_LVL R/W If set, GPIO6 input will use alternate lower VIH and VIL levels 7 GPI7_LVL R/W If set, GPIO7 input will use alternate lower VIH and VIL levels Description See the DC Electrical Characteristics for exact VIH and VIL levels. 73 www.national.com LM96194 16.13.3 Register BEh GPI/VID Level Control LM96194 16.13.4 Register BFh PWM Ramp Control Register Address Read/ Write Register Name BFh R/W PWM Ramp Control Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 VRD_RAMP PH_RAMP Bit Name R/W 3:0 VRD_RAMP R/W Sets the time delay between ramp steps for the VRD_HOT ramp up/ramp down PWM function. 7:4 PH_RAMP R/W Sets the time delay between ramp steps for the PROCHOT ramp up/ramp down PWM function. Default Value 00h Description If the time delay between steps is set to 0 ms, the PWM duty cycle goes immediately to 100% instead of ramping up gradually. VRD_RAMP or PH_RAMP 16.13.5 Register C0h Time Delay between Ramp Steps 0h 0 ms 1h 50 ms 2h 100 ms 3h 150 ms 4h 200 ms 5h 250 ms 6h 300 ms 7h 350 ms 8h 400 ms 9h 450 ms Ah 500 ms Bh 550 ms Ch 600 ms Dh 650 ms Eh 700 ms Fh 750 ms Fan Boost Hysteresis (Zones 1/2) Register Address Read/ Write Register Name C0h R/W Fan Boost Hysteresis (Zones 1/2) Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value H1 H2 44h Bit Name R/W Description 3:0 H1 R/W Sets the fan boost hysteresis for Zone 1a and 1b, has 1 C resolution. 7:4 H2 R/W Sets the fan boost hysteresis for zone 2a and 2b, has 1 C resolution. If the temperature zone is above fan boost temperature and then drops below the fan boost temperature, the following occurs: the PWM output remains at 100% until the temperature goes a certain amount below the fan boost temperature. These hysteresis registers control this amount and can be set anywhere from 0C to 15C (unsigned). www.national.com 74 Register Address Read/ Write Register Name C1h R/W Fan Boost Hysteresis (Zones 3/4) Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value H3 H4 44h Bit Name R/W 3:0 H3 R/W Sets the fan boost hysteresis for zone 3 and has 1C resolution. Description 7:4 H4 R/W Sets the fan boost hysteresis for zone 4 and has 1C resolution. If the temperature zone is above fan boost temperature and then drops below the fan boost temperature, the following occurs: the PWM output remains at 100% until the temperature goes a certain amount below the fan boost temperature. These hysteresis registers control this amount and can be set anywhere from 0C to 15C (unsigned). 75 www.national.com LM96194 16.13.6 Register C1h Fan Boost Hysteresis (Zones 3/4) LM96194 16.13.7 Register C2h Zones 1/2 Spike Smoothing Control Register Address Read/ Write Register Name Bit 7 C2h R/W Zones 1/2 Spike Smoothing Control ZN2E Bit 6 Bit 5 ZN2 Bit 4 Bit 3 ZN1E Bit 2 Bit 1 Bit 0 Default Value ZN1 00h Bit Name R/W Description 2:0 ZN1 R/W Configures the spike smoothing characteristics for zone 1a and 1b 3 ZN1E R/W When set, the filtered temperature for zone 1a and 1b is used for both limit checking and auto-fan control instead of the unfiltered temperature. Even when this bit is cleared, the filtered temperature can be read by software from the filtered temperature register. 6:4 ZN2 R/W Configures the spike smoothing characteristics for zone 2a and 2b 7 ZN2E R/W When set, the filtered temperature for zone 2a and 2b is used for both limit checking and auto-fan control instead of the unfiltered temperature. Even when this bit is cleared, the filtered temperature can be read by software from the filtered temperature register. If all the REMOTE1 or REMOTE2 pins are connected to a processor or chipset, instantaneous temperature spikes may be sampled by the LM96194. If these spikes are not ignored, the PWM outputs may cause the fans to turn on prematurely and produce unpleasant noise. Also, false error events may occur. For this reason, any zone that is connected to a chipset or processor may need spike smoothing enabled. The spike smoothing provides additional filtering above and beyond any A/D inherent averaging. When spike smoothing is enabled, the temperature reading registers still reflect the current value of the temperature--not the filtered value. Only the filtered temperature registers reflect the filtered value. www.national.com ZN1 or ZN2 Spike Smoothed Over 0h 11.8 seconds 1h 7.0 seconds 2h 4.4 seconds 3h 3.0 seconds 4h 1.6 seconds 5h 0.8 seconds 6h 0.6 seconds 7h 0.4 seconds 76 Register Address Read/ Write Register Name C3h R/W LUT 1/2 MinPWM and Hysteresis Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Default Value LUT_FC_TH12 MinPWM12 00h Bit Name R/W Description 3:0 LUT_FC_TH12 R/W This field sets the amount of hysteresis (in degrees C) that is used by the auto-fan control for LUT 1 and 2. This should be set greater than 0 to avoid unwanted oscillation between two steps in the look-up table. The resolution of this field is controlled by Special Function Control 2 register bit 4. 7:4 MinPWM12 R/W This field determines the duty cycle that the auto-fan control requests for LUT 1 and 2 if the temperature for the given zone falls below the programmed base temperature for the assigned LUT. This field accepts 16 possible values 13 of which are mapped to duty cycles according the table in the Auto-Fan Control section . 16.13.9 Register C4h Bit 0 LUT 3/4 MinPWM and Hysteresis Register Address Read/ Write Register Name C4h R/W LUT 3/4 MinPWM and Hysteresis Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value LUT_FC_TH34 MinPWM34 00h Bit Name R/W Description 3:0 LUT_FC_TH34 R/W This field sets the amount of hysteresis (in degrees C) that is used by the auto-fan control for LUT 3 and 4. This should be set greater than 0 to avoid unwanted oscillation between two steps in the look-up table. The resolution of this field is controlled by Special Function Control 2 register bit 5. 7:4 MinPWM34 R/W This field determines the duty cycle that the auto-fan control requests for LUT 3 and 4 if the temperature for the given zone falls below the programmed base temperature for the assigned LUT. This field accepts 16 possible values 13 of which are mapped to duty cycles according the table in the Auto-Fan Control section . 77 www.national.com LM96194 16.13.8 Register C3h LUT 1/2 MinPWM and Hysteresis LM96194 16.13.10 Register C5h GPO Register Address Read/ Write Register Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value C5h R/W GPO GPO7 GPO6 GPO5 GPO4 GPO3 GPO2 GPO1 GPO0 00h www.national.com Bit Name R/W Description 0 GPO0 R/W If set, GPIO_0 will be pulled low. If cleared, the output is not pulled low. This bit should be 0 if GPIO_0 is being used as an input. 1 GPO1 R/W If set, GPIO_1 will be pulled low. If cleared, the output is not pulled low. This bit should be 0 if GPIO_1 is being used as an input. 2 GPO2 R/W If set, GPIO_2 will be pulled low. If cleared, the output is not pulled low. This bit should be 0 if GPIO_2 is being used as an input. 3 GPO3 R/W If set, GPIO_3 will be pulled low. If cleared, the output is not pulled low. This bit should be 0 if GPIO_3 is being used as an input. 4 GPO4 R/W If set, GPIO_4 will be pulled low. If cleared, the output is not pulled low. This bit should be 0 if GPIO_4 is being used as an input. 5 GPO5 R/W If set, GPIO_5 will be pulled low. If cleared, the output is not pulled low. This bit should be 0 if GPIO_5 is being used as an input. 6 GPO6 R/W If set, GPIO_6 will be pulled low. If cleared, the output is not pulled low. This bit should be 0 if GPIO_6 is being used as an input. 7 GPO7 R/W If set, GPIO_7 will be pulled low. If cleared, the output is not pulled low. This bit should be 0 if GPIO_7 is being used as an input. 78 PROCHOT Control Register Address Read/ Write Register Name Bit 7 Bit 6 Bit 5 Bit 4 C6h R/W PROCHOT Override RES FORCE _P RES VRD _DIS Bit Name R/W 3:0 PHT_DC R/W PROCHOT duty cycle select. 4 P1_VRD1_DIS R/W When this bit is set by software, PROCHOT will not be asserted when VRD_HOT is asserted. 5 RES R/W RESERVED 6 FORCE_P R/W When this is set by software, PROCHOT will be asserted by the LM96194 with the duty cycle selected by PHT_DC. 7 RES R/W RESERVED Bit 3 Bit 2 Bit 1 Bit 0 PHT_DC Default Value 00h Description The period of the PWM signal driven on PROCHOT is 3.56 ms (80 internal 22.5 kHz clocks). The asserted time can be increased in 5 clock increments. 5 clocks is about 220 s and would represent 6.25% percent throttled. Possible settings for PHT_DC: PHT_DC Asserted Period 0h 5 clocks 1h 10 clocks 2h 15 clocks 3h 20 clocks 4h 25 clocks 5h 30 clocks 6h 35 clocks 7h 40 clocks 8h 45 clocks 9h 50 clocks Ah 55 clocks Bh 60 clocks Ch 65 clocks Dh 70 clocks Eh 75 clocks Fh 80 clocks 79 www.national.com LM96194 16.13.11 Register C6h LM96194 16.13.12 Register C7h PROCHOT Time Interval Register Address Read/ Write Register Name C7h R/W PROCHOT Time Interval Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value PH_TI RES 11h Bit Name R/W 3:0 PH_TI R/W Sets the monitoring interval for PROCHOT Description 7:4 RES R/W RESERVED Possible settings for PH_TI: P1_TI or P2_TI Monitoring Time Interval (seconds) 0h 0.73 1h 1.46 2h 2.9 3h 5.8 4h 11.7 5h 23.3 6h 46.6 7h 93.2 8h 186 9h 372 Ah-Fh Reserved Note that changing this value while PROCHOT measurements are running may cause the monitoring circuit to produce a erroneous value. To avoid alerts and invalid B_P_PROCHOT or H_P_PROCHOT Error Status values, only change this value while the chip is programmed for S3 or S4/5. www.national.com 80 PWM1 Control 1 Register Address Read/ Write Register Name Bit 7 C8h R/W PWM1 Control 1 RES Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 VRD RES PH LUT4 LUT3 LUT2 LUT1 Bit Name R/W 0 LUT1 R/W If set, PWM1 will be bound to LUT 1. 1 LUT2 R/W If set, PWM1 will be bound to LUT 2. 2 LUT3 R/W If set, PWM1 will be bound to LUT 3. 3 LUT4 R/W If set, PWM1 will be bound to LUT 4. 4 PH R/W If set, PWM1 will be bound to PROCHOT. 5 RES R/W RES 6 VRD1 R/W If set, PWM1 will be bound to VRD_HOT. 7 RES R/W RES Default Value 00h Description This register can bind PWM1 to several different control sources. The temperature zones control the PWM duty cycle using the table lookup function. The PROCHOT and VRD_HOT inputs control the PWM using the ramp up/ramp down functions. If multiple control sources are bound to PWM1, the largest duty cycle being requested will be used. 81 www.national.com LM96194 16.13.13 Register C8h LM96194 16.13.14 Register C9h PWM1 Control 2 Register Address Read/ Write Register Name C9h R/W PWM1 Control 2 www.national.com Bit 7 Bit 6 Bit 5 OVR_DC Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 PPL EPPL INV OVR Bit Name R/W Description 0 OVR R/W When set, enables manual duty cycle override for PWM1. 1 INV R/W Invert PWM1 output. When 0, 100% duty cycle corresponds to the PWM output continuously HIGH. When 1, 100% duty cycle corresponds to the PWM output continuously LOW. 2 EPPL R/W Enable PROCHOT PWM1 lock. When set, this bit causes bound PROCHOT events on PWM1 to trigger PPL (bit [3]). When cleared, PPL never gets set. 3 PPL R/W PROCHOT PWM1 lock. When set, this bit indicates that PWM1 is currently being held at 100% because a bound PROCHOT event occurred while EPPL (bit [2]) was set. This bit is cleared by writing a zero. Clearing this bit allows the fans to return to normal operation. This bit is not locked by the LOCK bit in the LM96194 Configuration register. 7:4 OVR_DC R/W This field sets the duty cycle that will be used by PWM1 whenever manual low resolution override mode is active. This field accepts 16 possible values that are mapped to duty cycles according the table in the Fan Control section. Whenever this register is read, it returns the duty cycle that is currently being used by PWM1 regardless of whether override mode is active or not. The value read may not match the last value written if another control source is requesting a greater duty cycle. This field always returns 0h when the PWM1 spin up cycle is active. 82 Default Value 00h PWM1 Control 3 Register Address Read/ Write Register Name CAh R/W PWM1 Control 3 Bit 7 Bit 6 Bit 5 Bit 4 SU_DUR[2:0] Bit 3 Bit 2 Bit 1 SU_DC SU_DUR[3] Bit Name R/W Description 3:0 SU_DC R/W This field sets the duty cycle that will be used whenever PWM1 experiences a Spin-Up cycle. This field accepts 16 possible values that are mapped to duty cycles according the table in the Auto-Fan Control section . Setting this field to 0h will effectively disable Spin-Up. 4 SU_DUR[3] R/W Most significant bit that sets the Spin-up duration for PWM1. 7:0 SU_DUR[2:0] R/W Least significant bits that set the Spin-Up duration for PWM1 least significant bits. Bit 0 Default Value 00h Bits 7:4 configure the spin-up duration. When the duty cycle of PWM1 changes from zero to a non-zero value, the spin-up sequence is activated for the specified amount of time. The available settings are defined according to this table: SU_DUR[3] (Bit 4) SU_DUR[2:0] (Bits[7:5]) Spin-Up Time 0 0h Spin-up disabled 0 1h 100 ms 0 2h 250 ms 0 3h 400 ms 0 4h 700 ms 0 5h 1s 0 6h 2s 0 7h 4s 1 0h 6s 1 1h 8s 1 2h 10 s 1 3h 12 s 1 4h 14 s 1 5h 16 s 1 6h 18 s 1 7h 20 s 83 www.national.com LM96194 16.13.15 Register CAh LM96194 16.13.16 Register CBh PWM1 Control 4 Register Address Read/ Write Register Name Bit 7 CBh R/W PWM1 Control 4 RES Bit 6 Bit 5 Bit 4 Bit 3 RES RES RES HF_LUT _MAP Bit 2 Bit 1 Bit 0 FREQ1 Bit Name R/W Description 2:0 FREQ1 R/W PWM1 frequency control. Setting this value controls the frequency of the PWM1 output according to the table below. 3 HF_LUT_MAP R/W Selects between two different maps for the PWM duty cycle assignment in the LUT when the PWM frequency is set to 22.5kHz. All 4 LUTs, VRD ramp, PROCHOT ramp, spin-up and low-resolution overide will be affected by this bit. When this bit is set the LUT duty cycle assignment will increment 6.25% steps starting at 25%. When this bit is cleared the duty cycle mapping will match the Low Frequency table. This bit has no effect when the PWM frequency is set to anything other than 22.5kHz and the low PWM frequency mapping will be used. 7:4 RES R Default Value 00h Reserved FREQ1 Frequency of PWM1 (Hz) 0h 22500 1h 96 2h 84 3h 72 4h 60 5h 48 6h 36 7h 12 LUT 1-4 Duty Cycle Assignment with PWM Frequency=22.5kHz as Controlled by the HF_LUT_MAP bit. LUT Duty Cycle Assignments when HF_LUT_MAP='0' LUT Duty Cycle Assignments when HF_LUT_MAP='1' (Low PWM Frequency Mapping) LUT Step Duty Cycle (%) LUT Step Duty Cycle (%) 1 25 1 25 2 31.25 2 28.57 3 37.5 3 32.14 4 43.75 4 35.71 5 50 5 39.29 6 56.25 6 42.86 7 62.25 7 46.43 8 68.75 8 50 9 75 9 53.57 10 81.25 10 57.14 11 87.5 11 71.43 12 93.75 12 85.71 13 100 13 100 www.national.com 84 PWM2 Control 1 Register Address Read/ Write Register Name Bit 7 CCh R/W PWM2 Control 1 RES Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 VRD RES PH LUT4 LUT3 LUT2 LUT1 Bit Name R/W 0 LUT1 R/W If set, PWM2 will be bound to LUT 1. 1 LUT2 R/W If set, PWM2 will be bound to LUT 2. 2 LUT3 R/W If set, PWM2 will be bound to LUT 3. 3 LUT4 R/W If set, PWM2 will be bound to LUT 4. 4 PH R/W If set, PWM2 will be bound to PROCHOT. 5 RES R/W RESERVED. 6 VRD R/W If set, PWM2 will be bound to VRD_HOT. 7 RES R/W RESEREVED Default Value 00h Description This register can bind PWM2 to several different control sources. The temperature zones control the PWM duty cycle using the table lookup function. The Px_PROCHOT and VRDx_HOT inputs control the PWM using the ramp up/ramp down functions. If multiple control sources are bound to PWM2, the largest duty cycle being requested will be used. 85 www.national.com LM96194 16.13.17 Register CCh LM96194 16.13.18 Register CDh PWM2 Control 2 Register Address Read/ Write Register Name CDh R/W PWM2 Control 2 www.national.com Bit 7 Bit 6 Bit 5 OVR_DC Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 PPL EPPL INV OVR Bit Name R/W Description 0 OVR R/W When set, enables manual duty cycle override for PWM2. 1 INV R/W Invert PWM1 output. When 0, 100% duty cycle corresponds to the PWM output continuously HIGH. When 1, 100% duty cycle corresponds to the PWM output continuously LOW. 2 EPPL R/W Enable PROCHOT PWM2 lock. When set, this bit causes bound PROCHOT events on PWM2 to trigger PPL (bit [3]). When cleared, PPL never gets set. 3 PPL R/W PROCHOT PWM2 lock. When set, this bit indicates that PWM2 is currently being held at 100% because a bound PROCHOT event occurred while EPPL (bit [2]) was set. This bit is cleared by writing a zero. Clearing this bit allows the fans to return to normal operation. This bit is not locked by the LOCK bit in the LM96194 Configuration register. 7:4 OVR_DC R/W This field sets the duty cycle that will be used by PWM2 whenever manual low resolution override mode is active. This field accepts 16 possible values that are mapped to duty cycles according the table in the Fan Control section. Whenever this register is read, it returns the duty cycle that is currently being used by PWM2 regardless of whether override mode is active or not. The value read may not match the last value written if another control source is requesting a greater duty cycle. This field always returns 0h when the PWM2 spin up cycle is active. 86 Default Value 00h PWM2 Control 3 Register Address Read/ Write Register Name CEh R/W PWM2 Control 3 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 SU_DUR[3] SU_DUR[2:0] Bit 2 Bit 1 SU_DC Bit Name R/W Description 3:0 SU_DC R/W This field sets the duty cycle that used whenever PWM2 experiences a Spin-Up cycle. This field accepts 16 possible values that are mapped to duty cycles according the table in the Auto-Fan Control section . Setting this field to 0h effectively disables Spin-Up. 4 SU_DUR[3] R/W Most significant bit that sets the spin-up duration for PWM2 7:5 SU_DUR[2:0] R/W Least significant bits that set the Spin-Up duration for PWM2. Bit 0 Default Value 00h Bits 7:4 configure the spin-up duration. When the duty cycle of PWM2 changes from zero to a non-zero value, the spin-up sequence is activated for the specified amount of time. The available settings are defined according to this table: SU_DUR[3] (Bit 4) SU_DUR[2:0] (Bits[7:5]) Spin-Up Time 0 0h Spin-up disabled 0 1h 100 ms 0 2h 250 ms 0 3h 400 ms 0 4h 700 ms 0 5h 1s 0 6h 2s 0 7h 4s 1 0h 6s 1 1h 8s 1 2h 10 s 1 3h 12 s 1 4h 14 s 1 5h 16 s 1 6h 18 s 1 7h 20 s 87 www.national.com LM96194 16.13.19 Register CEh LM96194 16.13.20 Register CFh PWM2 Control 4 Register Address Read/ Write Register Name Bit 7 CFh R/W PWM2 Control 4 RES Bit 6 Bit 5 Bit 4 Bit 3 RES RES RES HF_LUT _MAP Bit 2 Bit 1 Bit 0 FREQ2 Bit Name R/W Description 2:0 FREQ2 R/W PWM2 frequency control. Controls the frequency of the PWM2 output in the same fashion as FREQ1 in the PWM1 Control 4 register. 3 HF_LUT_MAP R/W Selects between two different maps for the PWM duty cycle assignment in the LUT when the PWM frequency is set to 22.5kHz. All 4 LUTs, VRD ramp, PROCHOT ramp, spin-up, and low-resolution override will be affected by this bit. When this bit is cleared the LUT duty cycle assignment will increment 6.25% steps starting at 25%. When this bit is set the duty cycle mapping will match the Low Frequency table. This bit has no effect when the PWM frequency is set to anything other than 22.5kHz and the low PWM frequency mapping will be used. 7:4 RES R Default Value 00h Reserved FREQ1 Frequency of PWM1 (Hz) 0h 22500 1h 96 2h 84 3h 72 4h 60 5h 48 6h 36 7h 12 LUT 1-4 Duty Cycle Assignment with PWM Frequency=22.5kHz as Controlled by the HF_LUT_MAP bit. LUT Duty Cycle Assignments when HF_LUT_MAP='0' LUT Duty Cycle Assignments when HF_LUT_MAP='1' (Low PWM Frequency Mapping) LUT Step Duty Cycle (%) LUT Step Duty Cycle (%) 1 25 1 25 2 31.25 2 28.57 3 37.5 3 32.14 4 43.75 4 35.71 5 50 5 39.29 6 56.25 6 42.86 7 62.25 7 46.43 8 68.75 8 50 9 75 9 53.57 10 81.25 10 57.14 11 87.5 11 71.43 12 93.75 12 85.71 13 100 13 100 www.national.com 88 LUT 1 to 4 Base Temperatures Register Address Read/ Write Register Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value D0h R/W LUT 1 Base Temperature 7 6 5 4 3 2 1 0 00h D1h R/W LUT 2 Base Temperature 7 6 5 4 3 2 1 0 00h D2h R/W LUT 3 Base Temperature 7 6 5 4 3 2 1 0 00h D3h R/W LUT 4 Base Temperature 7 6 5 4 3 2 1 0 00h The value in this register is used as the base in the temperature calculation for the auto fan control look-up table. These registers use the standard temperature format (8-bit signed data). The look-up table contains the temperature offsets. The offsets are added to the base temperature to determine the true temperature to be used for each table entry for auto fan control. 16.13.22 Register D4h-DFh Lookup Table Steps--LUT 1/2 and LUT 3/4 Offset Temperature Register Address Read/ Write Register Name D4h R/W Step 2 Temp Offset LUT3/4_STEP2 LUT1/2_STEP2 00h D5h R/W Step 3 Temp Offset LUT3/4_STEP3 LUT1/2_STEP3 00h D6h R/W Step 4 Temp Offset LUT3/4_STEP4 LUT1/2_STEP4 00h D7h R/W Step 5 Temp Offset LUT3/4_STEP5 LUT1/2_STEP5 00h D8h R/W Step 6 Temp Offset LUT3/4_STEP6 LUT1/2_STEP6 00h D9h R/W Step 7 Temp Offset LUT3/4_STEP7 LUT1/2_STEP7 00h DAh R/W Step 8 Temp Offset LUT3/4_STEP8 LUT1/2_STEP8 00h DBh R/W Step 9 Temp Offset LUT3/4_STEP9 LUT1/2_STEP9 00h DCh R/W Step 10 Temp Offset LUT3/4_STEP10 LUT1/2_STEP10 00h DDh R/W Step 11 Temp Offset LUT3/4_STEP11 LUT1/2_STEP11 00h DEh R/W Step 12 Temp Offset LUT3/4_STEP12 LUT1/2_STEP12 00h DFh R/W Step 13 Temp Offset LUT3/4_STEP13 LUT1/2_STEP13 00h Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value There are two look up tables of 13 steps (12 offsets), one for LUT 1 and 2 the other for LUT 3 and 4. Each 8-bit offset register contains the offset temperature for LUT 1 and 2 as well as the offset temperature for LUT 3 and 4. The format for the offsets is a 4-bit unsigned value, and one LSB is either 1C or 0.5C. The offset resolution is controlled by LT34_RS and LT12_RS bits found in the Special Function Control 2 register (at address BDh). Therefore, the offset range is variable as well and is either 15C to 0 C or 7.5C to 0C. See the Section 15.10 FAN CONTROL for information on how the base temperature/lookup table should be used for controlling the PWM output(s). 89 www.national.com LM96194 16.13.21 Register D0h-D3h LM96194 16.13.23 Register E0h Special Function TACH to PWM Binding Register Address Read/ Write Register Name E0h R/W Special Function TACH to PWM Binding Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value T4P2 T4P1 T3P2 T3P1 T2P2 T2P1 T1P2 T1P1 00h Bit Name R/W Description 0 T1P1 R/W If set, TACH1 is bound to PWM1. 1 T1P2 R/W If set, TACH1 is bound to PWM2. 2 T2P1 R/W If set, TACH2 is bound to PWM1. 3 T2P2 R/W If set, TACH2 is bound to PWM2. 4 T3P1 R/W If set, TACH3 is bound to PWM1. 5 T3P2 R/W If set, TACH3 is bound to PWM2. 6 T4P1 R/W If set, TACH4 is bound to PWM1. 7 T4P2 R/W If set, TACH4 is bound to PWM2. If a TACH channel is bound to a PWM channel, TACH errors on that channel are automatically masked when the bound PWM is at 0% duty cycle or performing spin-up. Behavior is undefined if a TACH channel is bound to both PWM outputs. This register must be setup when Smart Tach Mode is enabled in register BDh, Special Function Control 2, and when Tach Boost is enabled in register E1h, Tachometer Fan Boost Cotrol. 16.13.24 Register E1h Tachometer Fan Boost Control Register Register Address Read/ Write Register Name Bit 7 Bit 6 E1h R/W Tach Fan Boost Control RES TBS Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 TBT[5:0] Bit 0 Default Value 3Fh Lock Bit Name R/W Description X 5:0 TBT[5:0]] R/W TACH error fan boost enable timeout. Set to 63 (3Fh) to disable the TACH error fan boost feature (default). Values other than 63 enable the TACH error fan boost feature and set the timeout according to the following table. 6 TBS R/W TACH boost status: When set, this bit indicates that the TACH error boost has been triggered and is currently requesting 100% PWM. If bits [5:0] are configured for an infinite timeout, and the TACH error (s) have ceased, then writing a zero to this bit will un-trigger the TACH boost. If TACH error boost is disabled, this bit always returns a 0. 7 RES R Reserved Timeout Assignments for TBT[5:0] www.national.com TBT[5:0] Timeout/Function 0 0 1 3 * * * * * * N N * 32 * 0.091 sec 60 175 61 178 62 Infinite setting (software must clear bit 6 of this register to reset) 63 Disabled 90 LM96194 Status Control Register Address Read/ Write Register Name E2h R/W LM96194 Status/ Control Lock X Bit 7 Bit 6 BMC _ERR HOST _ERR Bit 5 Bit 4 TACH_EDGE Bit 3 Bit 2 Bit 1 Bit 0 GPI5_A M GPI4_AM ASF OVRID Bit Name R/W Description 0 OVRID R/W If this bit is set, all PWM outputs go to 100% duty cycle. 1 ASF R/W If this bit is set, BMC error registers support ASF, i.e. reset on read. When not in ASF mode, a write "1" is required to clear the bits in the BMC error status registers. 2 GPI4_AM R/W GPI4 Auto Mask Enable If this bit is set, an error event on GPI4 causes all other error events to be masked. The BMC Error Status registers do not reflect any new error events until the GPI4_ERR bit is cleared in the B_GPI Error Status register. The HOST Error Status registers do not reflect any new error events until the GPI4_ERR bit is cleared in the H_GPI Error Status register. If a CPU_THERMTRIP signal is connected to GPIO4, this ensures that unwanted error events do not fire once CPU_THERMTRIP is asserted. 3 GP15_AM R/W GPI5 Auto Mask Enable This bit works exactly the same as GPI4_AM, but applies to GPI5. 5:4 TACH_EDGE R/W This field determines what type of edges are used for measuring fan tach pulses. This effects all four tachometer inputs. 6 HOST_ERR R This bit gets set if any error bit is set in any of the Host Error Status registers (H_). 7 BMC_ERR R This bit gets set if any error bit is set in any of the BMC Error Status registers (B_). When this bit is set, ALERT are asserted if enabled. TACH_EDGE Default Value 00h Edge Type Used for Tachometer Measurements 0h Either rising or falling edges may be used. 1h Rising edges only 2h Falling edges only 3h Reserved 91 www.national.com LM96194 16.13.25 Register E2h LM96194 16.13.26 Register E3h LM96194 Configuration Register Address Read/ Write Register Name Bit 7 E3h R/W LM96194 Configuration READY www.national.com Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 RES ALERT_ COMP_EN RES ALERT _EN GMSK LOCK START Lock Bit Name R/W Description x 0 START R/W When this bit is 0, the LM96194 operates in basic mode. All error events are masked. The auto fan control algorithm is disabled. Both PWMs are set to 0%. All monitoring functions are active and the value registers are updated. Once this bit is set, error events are no longer globally masked, and the auto-fan control algorithm is enabled. Fan boost uses the programmed values. It is expected that all limit and setup registers are set by BIOS or application software prior to setting this bit. X 1 LOCK R/W Setting this bit locks all registers and register bits that are indicated as lockable. Lockable registers have an "x" in the Lock column of their description. This register is locked once it is set. This bit can only be cleared by an external device asserting RESET. 2 GMSK R/W Global Mask When this bit is set by software, all error events are masked. Setting this bit does not effect any other mask registers or value registers. 3 ALERT_EN R/W When this bit is set, the ALERT output is enabled. If this bit is cleared, the ALERT output is disabled. 4 RES R/W RESERVED. Must be left low for proper operation of PROCHOT circuitry. 5 ALERT_ COMP_EN R/W When this bit is set the ALERT output will function in the thermal comparator mode. In the thermal comparator mode ALERT will be asserted only for unmasked thermal error events. ALERT will be de-assserted immediately when the error event ceases. 6 RES R/W Reserved 7 READY R The LM96194 sets this bit automatically after valid data has been collected for all temperatures and voltages. Software should not use any temperature or voltage values until this bit has been set. 92 Default Value 00h LM96194 16.14 SLEEP STATE CONTROL AND MASK REGISTERS 16.14.1 Register E4h Sleep State Control Register Address Read/ Write Register Name E4h R/W Sleep State Control Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 SB RES Bit Name R/W Description 1:0 SB R/W Sleep State Control. Setting this field tells the LM96194 which sleep state the system is in. Several error events are masked depending on the state of this field. 7:2 RES R Default Value 03h Reserved SB Description 00 Sleep state = S0 Do not mask errors. 01 Sleep state = S1 Mask errors according to S1 mask registers and standard S1 masking. 10 Sleep state = S3 Mask errors according to S3 mask registers and standard S3 masking. 11 Sleep state = S4/5 Mask errors according to S4/5 mask registers and standard S4/5 masking. This mode is activated automatically if the RESET input is asserted. 93 www.national.com LM96194 16.14.2 Register E5h S1 GPI Mask Register Read/ Register Address Write Name E5h R/W S1 GPI Mask Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value GPI7_S1 _MSK GPI6_S1 _MSK GPI5_S1 _MSK GPI4_S1 _MSK GPI3_S1 _MSK GPI2_S1 _MSK GPI1_S1 _MSK GPI0_S1 _MSK FFh Bit Name R/W 0 GPI0_S1_MSK R/W If set, GPI0 errors are masked in S1 sleep state. 1 GPI1_S1_MSK R/W If set, GPI1 errors are masked in S1 sleep state. 2 GPI2_S1_MSK R/W If set, GPI2 errors are masked in S1 sleep state. 3 GPI3_S1_MSK R/W If set, GPI3 errors are masked in S1 sleep state. 4 GPI4_S1_MSK R/W If set, GPI4 errors are masked in S1 sleep state. 5 GPI5_S1_MSK R/W If set, GPI5 errors are masked in S1 sleep state. 6 GPI6_S1_MSK R/W If set, GPI6 errors are masked in S1 sleep state. 7 GPI7_S1_MSK R/W If set, GPI7 errors are masked in S1 sleep state. 16.14.3 Register E6h Description S1 Tach Mask Register Address Read/ Write Register Name E6h R/W S1 Tach Mask www.national.com Bit 7 Bit 7 Bit 6 Bit 5 RES Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value TACH4_S1 _MSK TACH3_S1 _MSK TACH2_S1 _MSK TACH1_S1 _MSK 0Fh Bit Name R/W 0 TACH1_S1_MSK R/W If set, Tach1 errors are masked in S1 sleep state. Description 1 TACH2_S1_MSK R/W If set, Tach2 errors are masked in S1 sleep state. 2 TACH3_S1_MSK R/W If set, Tach3 errors are masked in S1 sleep state. 3 TACH4_S1_MSK R/W If set, Tach4 errors are masked in S1 sleep state. 7:4 RES R Reserved 94 S3 GPI Mask Register Read/ Register Address Write Name E7h R/W S3 GPI Mask Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value GPI7_S3 _MSK GPI6_S3 _MSK GPI5_S3 _MSK GPI4_S3 _MSK GPI3_S3 _MSK GPI2_S3 _MSK GPI1_S3 _MSK GPI0_S3 _MSK FFh Bit Name R/W 0 GPI0_S3_MSK R/W If set, GPI0 errors are masked in S3 sleep state. 1 GPI1_S3_MSK R/W If set, GPI1 errors are masked in S3 sleep state. 2 GPI2_S3_MSK R/W If set, GPI2 errors are masked in S3 sleep state. 3 GPI3_S3_MSK R/W If set, GPI3 errors are masked in S3 sleep state. 4 GPI4_S3_MSK R/W If set, GPI4 errors are masked in S3 sleep state. 5 GPI5_S3_MSK R/W If set, GPI5 errors are masked in S3 sleep state. 6 GPI6_S3_MSK R/W If set, GPI6 errors are masked in S3 sleep state. 7 GPI7_S3_MSK R/W If set, GPI7 errors are masked in S3 sleep state. 16.14.5 Register E8h Description S3 Tach Mask Register Address Read/ Write Register Name E8h R/W S3 Tach Mask Bit 7 Bit 6 Bit 5 Bit 3 Bit 2 Bit 1 Bit 0 Default Value TACH4_S3 _MSK TACH3_S3 _MSK TACH2_S3 _MSK TACH1_S3 _MSK 0Fh Bit 4 RES Bit Name R/W 0 TACH1_S3_MSK R/W If set, Tach1 errors are masked in S3 sleep state. 1 TACH2_S3_MSK R/W If set, Tach2 errors are masked in S3 sleep state. 2 TACH3_S3_MSK R/W If set, Tach3 errors are masked in S3 sleep state. 3 TACH4_S3_MSK R/W If set, Tach4 errors are masked in S3 sleep state. 7:4 RES R 16.14.6 Register E9h Description Reserved S3 Temperature/Voltage Mask Register Address Read/ Write Register Name E9h R/W S3 Voltage Mask Bit 7 Bit 6 Bit 5 Bit 4 RES Bit 3 Bit 2 Bit 1 Bit 0 Default Value TEMP_ S3_MSK AIN14_S3 _MSK AIN13_S3 _MSK AIN12_S3 _MSK 07h Bit Name R/W Description 0 RES R/W RESERVED. Leave "HIGH" for proper operation of the part. 1 AIN13_S3_MS K R/W If set, AIN13 errors as masked in S3 sleep state. 2 AIN14_S3_MS K R/W If set, AIN14 errors as masked in S3 sleep state. 3 TEMP_S3_MS K R/W If set, temperature errors and diode fault errors for zones 1 and 2 are masked in S3 sleep state. 7:3 RES R Reserved 95 www.national.com LM96194 16.14.4 Register E7h LM96194 16.14.7 Register EAh S4/5 GPI Mask Register Address Read/ Write Register Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value EAh R/W S4/5 GPI Mask GPI7 _S4/5 _MSK GPI6 _S4/5 _MSK GPI5 _S4/5 _MSK GPI4 _S4/5 _MSK GPI3 _S4/5 _MSK GPI2 _S4/5 _MSK GPI1 _S4/5 _MSK GPI0 _S4/5 _MSK FFh Bit Name R/W 0 GPI0_S4/5_MSK R/W If set, GPI0 errors are masked in S4/5 sleep state. 1 GPI1_S4/5_MSK R/W If set, GPI1 errors are masked in S4/5 sleep state. 2 GPI2_S4/5_MSK R/W If set, GPI2 errors are masked in S4/5 sleep state. 3 GPI3_S4/5_MSK R/W If set, GPI3 errors are masked in S4/5 sleep state. 4 GPI4_S4/5_MSK R/W If set, GPI4 errors are masked in S4/5 sleep state. 5 GPI5_S4/5_MSK R/W If set, GPI5 errors are masked in S4/5 sleep state. 6 GPI6_S4/5_MSK R/W If set, GPI6 errors are masked in S4/5 sleep state. 7 GPI7_S4/5_MSK R/W If set, GPI7 errors are masked in S4/5 sleep state. 16.14.8 Register EBh Description S4/5 Temperature/Voltage Mask Register Address Read/ Write Register Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value EBh R/W S4/5 Voltage Mask RES TEMP_ S4/5_MSK AIN14_S4/5 _MSK AIN13_S4/5 _MSK AIN12_S4/5 _MSK 07h www.national.com Bit Name R/W Description 0 RES R/W RESERVED. Leave "HIGH" for proper operation of the part. 1 AIN13_S4/5_MSK R/W If set, AIN13 errors as masked in S4/5 sleep state. 2 AIN14_S4/5_MSK R/W If set, AIN14 errors as masked in S4/5 sleep state. 3 TEMP_S4/5_MSK R/W If set, temperature errors and diode fault errors for zones 1 and 2 are masked in S4/5 sleep state. 7:3 RES R Reserved 96 LM96194 16.15 OTHER MASK REGISTERS 16.15.1 Register ECh GPI Error Mask Register Address Read/ Write Register Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value ECh R/W GPI Error Mask GPI7 _MSK GPI6 _MSK GPI5 _MSK GPI4 _MSK GPI3 _MSK GPI2 _MSK GPI1 _MSK GPI0 _MSK FFh Bit Name R/W 0 GPI0_MSK R/W When this bit is set, GPI0 error events are masked. Description 1 GPI1_MSK R/W When this bit is set, GPI1 error events are masked. 2 GPI2_MSK R/W When this bit is set, GPI2 error events are masked. 3 GPI3_MSK R/W When this bit is set, GPI3 error events are masked. 4 GPI4_MSK R/W When this bit is set, GPI4 error events are masked. 5 GPI5_MSK R/W When this bit is set, GPI5 error events are masked. 6 GPI6_MSK R/W When this bit is set, GPI6 error events are masked. 7 GPI7_MSK R/W When this bit is set, GPI7 error events are masked. These bits mask the corresponding bits in the B_ and H_GPI Error Status Registers. They do not effect the GPI State register. 16.15.2 Register EDh Miscellaneous Error Mask Register Address Read/ Write Register Name EDh R/W Miscellaneous Error Mask Bit Name R/W Bit 7 Bit 6 RES Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value RES DVccp _MSK SCSI1 _MSK RES RES VRD _MSK 3Fh Description 0 VRD_MSK R/W When this bit is set, VRD_HOT error events are masked. 1:2 RES R/W RESERVED 3 SCSI_MSK R/W When this bit is set, GPI8 error events are masked. 4 DVccp_MSK R/W When this bit is set, dynamic Vccp limit error events for AD_IN7 (CPU1) are masked. 5 RES R/W RESERVED. Leave "HIGH" for proper operation of the part. 7:6 RES R Reserved 97 www.national.com LM96194 16.15.3 Register EE and EFh Zone 1a and Zone 2a Adjustment Register Register Address Read/ Write Register Name Bit 7 Bit 6 EEh R/W Zone 1a Adjust RES RES Z1a_ADJUST[5:0] 00h EFh R/W Zone 2a Adjust RES RES Z2a_ADJUST[5:0] 00h Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Value Bit Name R/W Description 5:0 Z1a_ADJUST[5:0] or Z2a_ADJUST[5:0] R/W 6-bit signed 2's complement offset adjustment. This value is added to all zone 1a and 2a temperature measurements as they are made. All LM96194 registers and functions behave as if the resulting temperature was the true measured temperature. This register allows offset adjustments from +31C to -32C in 1C steps. The format is sign two's complement. 7:6 RES R www.national.com Reserved 98 1, Note 2) If Military/Aerospace specified devices are required, please contact the National Semiconductor Sales Office/ Distributors for availability and specifications. Positive Supply Voltage (VDD) 6.0V Voltage on Any Digital Input or Output Pin -0.3V to 6.0V Voltage on +5V Input -0.3V to +6.667V Voltage at Positive Remote Diode Inputs, AD_IN1, AD_IN2, AD_IN3, and AD_IN15 Inputs -0.3V to (VDD + 0.05V) Voltage at Other Analog Voltage Inputs -0.3V to +6.0V Input Current at Thermal Diode Negative Inputs 1 mA Input Current at any pin (Note 3) 10mA Package Input Current (Note 3) 100 mA Maximum Junction Temperature (Note 9) (TJMAX) 150 C 18.0 Operating Ratings (Note 1, Note 2) TMIN TA TMAX -40C TA +85C 3.3V +3.0V to +3.6V -0.05V to +5.5V -0.05V to (VDD + 0.05V) 79C/W Operating Temperature Range Nominal Supply Voltage Supply Voltage Range (VDD) VID0-VID5 Digital Input Voltage Range Package Thermal Resistance (Note 6) DC Electrical Characteristics The following limits apply for +3.0 VDC to +3.6 VDC, unless otherwise noted. Bold face limits apply for TA = TJ over TMIN to TMAX of the operating range; all other limits TA = TJ = 25C unless otherwise noted. TA is the ambient temperature of the LM96194; TJ is the junction temperature of the LM96194; TD is the junction temperature of the thermal diode. Symbol Parameter Conditions Typical (Note 9) Limits (Note 10) Units (Limits) Converting, Interface and Fans Inactive, Peak Current 2 2.75 mA (max) POWER SUPPLY CHARACTERISTICS Power Supply Current Converting, Interface and Fans Inactive, Average Current Power-On Reset Threshold Voltage 1.6 2 mA 1.6 V (min) 2.7 V (max) TEMPERATURE-TO-DIGITAL CONVERTER CHARACTERISTICS Local Temperature Accuracy Over Full Range -40C TA < 0C 2 4 C (max) 0C TA 85C 2 3 C (max) TA = +55C 1 2.5 C (max) Local Temperature Resolution 1 Remote Thermal Diode Temperature Accuracy(Note 0C TA 85C 8) and 0C TD 100C 0C TA 85C and TD =70C -40C TA < 0C Remote Thermal Diode Temperature Accuracy Extended to Down to -40 for MMBT3904 Only and -40C TD < 0C Remote Thermal Diode Temperature Accuracy; 0C TA 85C targeted for a typical Pentium processor on 90nm or and 25C T 70C D 65nm process (Note 8) Remote Temperature Resolution C 3 C (max) 2.5 C (max) 4 C (max) 1 C 1 Thermal Diode Source Current Thermal Diode Current Ratio High Level 172 Low Level 10.75 C 230 A (max) A 16 99 www.national.com LM96194 ESD Susceptibility (Note 4) Human Body Model 3 kV Machine Model 300V Charged Device Model 750V Storage Temperature -65C to +150C Soldering process must comply with National's reflow temperature profile specifications. Refer to www.national.com/packaging/. (Note 5) 17.0 Absolute Maximum Ratings (Note LM96194 Symbol TC Parameter Conditions Typical (Note 9) Total Monitoring Cycle Time Limits (Note 10) Units (Limits) 100 ms (max) 2 % of FS (max) ANALOG-TO-DIGITAL VOLTAGE MEASUREMENT CONVERTER CHARACTERISTICS TUE Total Unadjusted Error (Note 12) DNL Differential Non-Linearity 1 LSB PSS Power Supply (VDD) Sensitivity 1 %/V (of FS) TC Total Monitoring Cycle Time 100 ms (max) 140 k (min) 60 nA (max) 8 mA (min) IOUT = 8.0 mA 0.4 V (max) Output Low Voltage (Note excessive current flow causes self-heating and degrades the internal temperature accuracy.) IOUT = 4.0 mA 0.4 V (min) IOUT = 6 mA 0.55 V (min) IOH High Level Output Leakage Current VOUT = VDD 10 A (max) IOTMAX Maximum Total Sink Current for all Digital Outputs Combined 32 mA (max) CO Digital Output Capacitance Input Resistance for Inputs with Dividers 200 AD_IN1- AD_IN3 and AD_IN8 Analog Input Leakage Current (No Dividers are present on these inputs.) (Note 13) DIGITAL OUTPUTS: PWM1, PWM2 IOL Maximum Current Sink VOL Output Low Voltage DIGITAL OUTPUTS: ALL VOL 0.1 20 pF DIGITAL INPUTS: ALL VIH Input High Voltage Except Address Select VIL Input Low Voltage Except Address Select VIH Input High Voltage for Address Select VIM Input Mid Voltage for Address Select 43% VDD 57% VDD V (min) V (max) VIL Input Low Voltage for Address Select 10% VDD V (max) VHYST DC Hysteresis IIH Input High Current VIN = VDD -10 A (min) IIL Input Low Current VIN = 0V 10 A (max) CIN Digital Input Capacitance 2.1 V (min) 0.8 V (max) 90% VDD V (min) 0.3 V 20 pF DIGITAL INPUTS: P1_VIDx, P2_VIDx, GPI_9, GPI_8, GPIO_7, GPIO_6, GPIO_5, GPIO_4 (When respective bit set in Register BEh GPI/VID Level Control) VIH Alternate Input High Voltage (AGTL+ Compatible) 0.8 V (min) VIL Alternate Input Low Voltage (AGTL+ Compatible) 0.4 V (max) www.national.com 100 The following limits apply for +3.0 VDC to +3.6 VDC, unless otherwise noted. Bold face limits apply for TA = TJ = TMIN to TMAX of the operating range; all other limits TA = TJ = 25C unless otherwise noted. Symbol Parameter Conditions Typical (Note 9) Limits (Note 10) Units (Limits) FAN RPM-TO-DIGITAL CHARACTERISTICS Counter Resolution 14 bits Number of fan tach pulses count is based on 2 pulses Counter Frequency 22.5 Accuracy kHz 6 % (max) 6 % (max) 6 % (max) 250 330 ms (min) ms (max) PWM OUTPUT CHARACTERISTICS Frequency Tolerances Duty-Cycle Tolerance 2 RESET INPUT/OUTPUT CHARACTERISTICS Output Pulse Width Upon Power Up Minimum Input Pulse Width Reset Output Fall Time 1.6V to 0.4V Logic Levels 10 s (min) 1 s (max) 10 100 kHz (min) kHz (max) SMBus TIMING CHARACTERISTICS fSMBCLK SMBCLK (Clock) Clock Frequency tBUF SMBus Free Time between Stop and Start Conditions 4.7 s (min) tHD;STA Hold time after (Repeated) Start Condition. After this period, the first clock is generated. 4.0 s (min) tSU;STA Repeated Start Condition Setup Time 4.7 s (min) tSU;STO Stop Condition Setup Time 4.0 s (min) tSU;DAT Data Input Setup Time to SMBCLK High 250 ns (min) tHD;DAT Data Output Hold Time after SMBCLK Low 300 1075 ns (min) ns (max) tLOW SMBCLK Low Period 4.7 50 s (min) s (max) tHIGH SMBCLK High Period 4.0 50 s (min) s (max) tR Rise Time 1 s (max) tF Fall Time 300 ns (max) tTIMEOUT Timeout SMBDAT or SMBCLK low time required to reset the Serial Bus Interface to the Idle State 25 35 ms ms (min) ms (max) 500 ms (max) 400 pF (max) tPOR Time in which a device must be operational after power-on reset CL Capacitance Load on SMBCLK and SMBDAT 31 VDD > +2.8V 101 www.national.com LM96194 AC Electrical Characteristics LM96194 20194403 Note 1: Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for which the device is functional, but do not guarantee specific performance limits. For guaranteed specifications and test conditions, see the Electrical Characteristics. The guaranteed specifications apply only for the test conditions listed. Some performance characteristics may degrade when the device is not operated under the listed test conditions. Note 2: All voltages are measured with respect to GND, unless otherwise noted. Note 3: When the input voltage (VIN) at any pin exceeds the power supplies (VIN < (GND or AGND) or VIN > VDD, except for analog voltage inputs), the current at that pin should be limited to 10 mA. The 100 mA maximum package input current rating limits the number of pins that can safely exceed the power supplies with an input current of 10 mA to ten. Parasitic components and/or ESD protection circuitry are shown below for the LM96194's pins. Care should be taken not to forward bias the parasitic diode, D1, present on pins D+ and D- as shown in circuits C and D. Doing so by more than 50 mV may corrupt temperature measurements. D1 and the ESD Clamp are connected between V+ (VDD, AD_IN16) and GND as shown in circuit B. SNP stands for snap-back device. Pin # Circuit PROCHOT Symbol 1 A GND 2 A GND 3 A GND 4 A GND 5 A GND 6 A GPIO_0/TACH1 7 A GPIO_1/TACH2 8 A GPIO_2/TACH3 9 A GPIO_3/TACH4 10 A GPIO_4 /THERMTRIP 11 A GPIO_5 12 A GPIO_6 13 A GPIO_7 14 A VRD_HOT 15 A GND 16 A SCSI_TERM1 17 A SMBDAT 18 A SMBCLK 19 A ALERT/XtestOut 20 A RESET 21 A AGND 22 B (Internally shorted to GND pin.) REMOTE1- 23 C REMOTE1+ 24 D REMOTE2- 25 C REMOTE+ 26 D AD_IN1 27 D AD_IN2 28 D AD_IN3 29 D www.national.com All Input Circuits Circuit A Circuit B Circuit C 102 Symbol Circuit 30 E AD_IN5 31 E GND 32 E GND 33 E GND 34 E AD_IN6 35 E AD_IN7 36 E AD_IN8 37 D ADDR_SEL 38 A AD_IN9/VDD (V+) 39 B GND 40 B (Internally shorted to AGND.) PWM1 41 A PWM2 42 A P1_VID0 43 A P1_VID1 44 A P1_VID2 45 A P1_VID3 46 A P1_VID4 47 A P1_VID5 48 A LM96194 Pin # AD_IN4 All Input Circuits Circuit D Circuit E Note 4: Human body model, 100 pF discharged through a 1.5 k resistor. Machine model, 200 pF discharged directly into each pin. Charged device model (CDM) simulates a pin slowly acquiring charge (such as from a device sliding down the feeder in an automated assembler) then rapidly being discharged. Note 5: Reflow temperature profiles are different for lead-free and non lead-free packages. Note 6: The maximum power dissipation must be de-rated at elevated temperatures and is dictated by TJMAX, JA and the ambient temperature, TA. The maximum allowable power dissipation at any temperature is PD MAX= (TJMAX - TA) / JA. The JAfor the LM96194 when mounted to 1 oz. copper foil PCB the JA with different air flow is listed in the following table. Air Flow Junction to Ambient Thermal Resistance, JA 0 m/s 28 C/W 1.14 m/s (225 LFPM) 25 C/W 2.54 m/s (500 LFPM) 22 C/W Note 7: See the URL "http://www.national.com/packaging/" for other recommendations and methods of soldering surface mount devices. Note 8: At the time of first pubication of this specification (Jan 2006), this specification applies to either Pentium or Xeon Processors on 90nm or 65nm process when TruTherm is selected. When TruTherm is deselected this specification applies to an MMBT3904. This specification does include the error caused by the variability of the diode ideality and series resistance parameters. Note 9: Typical parameters are at TJ = TA = 25 C and represent most likely parametric norm. Note 10: Limits are guaranteed to National's AOQL (Average Outgoing Quality Level). Note 11: TUE (Total Unadjusted Error) includes Offset, Gain and Linearity errors of the ADC. Note 12: Total Monitoring Cycle Time includes all temperature and voltage conversions. Note 13: Leakage current approximately doubles every 20 C. Note 14: A total digital I/O current of 40 mA can cause 6 mV of offset in Vref. Note 15: Timing specifications are tested at the TTL logic levels, VIL = 0.4V for a falling edge and VIH = 2.4V for a rising edge. TRI-STATE output voltage is forced to 1.4V. 103 www.national.com LM96194 19.0 Physical Dimensions inches (millimeters) unless otherwise noted 48-Lead Molded LLP Package, Order Number LM96194CISQ or LM96194CIAQX, NS Package Number SQA48A www.national.com 104 LM96194 Notes 105 www.national.com LM96194 TruThermTM Hardware Monitor with PI Fan Control for Workstation Management Notes For more National Semiconductor product information and proven design tools, visit the following Web sites at: www.national.com Products Design Support Amplifiers www.national.com/amplifiers WEBENCH(R) Tools www.national.com/webench Audio www.national.com/audio App Notes www.national.com/appnotes Clock and Timing www.national.com/timing Reference Designs www.national.com/refdesigns Data Converters www.national.com/adc Samples www.national.com/samples Interface www.national.com/interface Eval Boards www.national.com/evalboards LVDS www.national.com/lvds Packaging www.national.com/packaging Power Management www.national.com/power Green Compliance www.national.com/quality/green Switching Regulators www.national.com/switchers Distributors www.national.com/contacts LDOs www.national.com/ldo Quality and Reliability www.national.com/quality LED Lighting www.national.com/led Feedback/Support www.national.com/feedback Voltage References www.national.com/vref Design Made Easy www.national.com/easy www.national.com/powerwise Applications & Markets www.national.com/solutions Mil/Aero www.national.com/milaero PowerWise(R) Solutions Serial Digital Interface (SDI) www.national.com/sdi Temperature Sensors www.national.com/tempsensors SolarMagicTM www.national.com/solarmagic PLL/VCO www.national.com/wireless www.national.com/training PowerWise(R) Design University THE CONTENTS OF THIS DOCUMENT ARE PROVIDED IN CONNECTION WITH NATIONAL SEMICONDUCTOR CORPORATION ("NATIONAL") PRODUCTS. NATIONAL MAKES NO REPRESENTATIONS OR WARRANTIES WITH RESPECT TO THE ACCURACY OR COMPLETENESS OF THE CONTENTS OF THIS PUBLICATION AND RESERVES THE RIGHT TO MAKE CHANGES TO SPECIFICATIONS AND PRODUCT DESCRIPTIONS AT ANY TIME WITHOUT NOTICE. NO LICENSE, WHETHER EXPRESS, IMPLIED, ARISING BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT. TESTING AND OTHER QUALITY CONTROLS ARE USED TO THE EXTENT NATIONAL DEEMS NECESSARY TO SUPPORT NATIONAL'S PRODUCT WARRANTY. EXCEPT WHERE MANDATED BY GOVERNMENT REQUIREMENTS, TESTING OF ALL PARAMETERS OF EACH PRODUCT IS NOT NECESSARILY PERFORMED. NATIONAL ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR BUYER PRODUCT DESIGN. BUYERS ARE RESPONSIBLE FOR THEIR PRODUCTS AND APPLICATIONS USING NATIONAL COMPONENTS. PRIOR TO USING OR DISTRIBUTING ANY PRODUCTS THAT INCLUDE NATIONAL COMPONENTS, BUYERS SHOULD PROVIDE ADEQUATE DESIGN, TESTING AND OPERATING SAFEGUARDS. EXCEPT AS PROVIDED IN NATIONAL'S TERMS AND CONDITIONS OF SALE FOR SUCH PRODUCTS, NATIONAL ASSUMES NO LIABILITY WHATSOEVER, AND NATIONAL DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY RELATING TO THE SALE AND/OR USE OF NATIONAL PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT. LIFE SUPPORT POLICY NATIONAL'S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF NATIONAL SEMICONDUCTOR CORPORATION. As used herein: Life support devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in a significant injury to the user. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system or to affect its safety or effectiveness. National Semiconductor and the National Semiconductor logo are registered trademarks of National Semiconductor Corporation. All other brand or product names may be trademarks or registered trademarks of their respective holders. Copyright(c) 2010 National Semiconductor Corporation For the most current product information visit us at www.national.com National Semiconductor Americas Technical Support Center Email: support@nsc.com Tel: 1-800-272-9959 www.national.com National Semiconductor Europe Technical Support Center Email: europe.support@nsc.com National Semiconductor Asia Pacific Technical Support Center Email: ap.support@nsc.com National Semiconductor Japan Technical Support Center Email: jpn.feedback@nsc.com IMPORTANT NOTICE Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI's terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI's standard warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed. TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and applications using TI components. To minimize the risks associated with customer products and applications, customers should provide adequate design and operating safeguards. TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right, or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI. Reproduction of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive business practice. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional restrictions. Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements. TI products are not authorized for use in safety-critical applications (such as life support) where a failure of the TI product would reasonably be expected to cause severe personal injury or death, unless officers of the parties have executed an agreement specifically governing such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of TI products in such safety-critical applications, notwithstanding any applications-related information or support that may be provided by TI. Further, Buyers must fully indemnify TI and its representatives against any damages arising out of the use of TI products in such safety-critical applications. TI products are neither designed nor intended for use in military/aerospace applications or environments unless the TI products are specifically designated by TI as military-grade or "enhanced plastic." Only products designated by TI as military-grade meet military specifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade is solely at the Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use. TI products are neither designed nor intended for use in automotive applications or environments unless the specific TI products are designated by TI as compliant with ISO/TS 16949 requirements. Buyers acknowledge and agree that, if they use any non-designated products in automotive applications, TI will not be responsible for any failure to meet such requirements. Following are URLs where you can obtain information on other Texas Instruments products and application solutions: Products Applications Audio www.ti.com/audio Communications and Telecom www.ti.com/communications Amplifiers amplifier.ti.com Computers and Peripherals www.ti.com/computers Data Converters dataconverter.ti.com Consumer Electronics www.ti.com/consumer-apps DLP(R) Products www.dlp.com Energy and Lighting www.ti.com/energy DSP dsp.ti.com Industrial www.ti.com/industrial Clocks and Timers www.ti.com/clocks Medical www.ti.com/medical Interface interface.ti.com Security www.ti.com/security Logic logic.ti.com Space, Avionics and Defense www.ti.com/space-avionics-defense Power Mgmt power.ti.com Transportation and Automotive www.ti.com/automotive Microcontrollers microcontroller.ti.com Video and Imaging RFID www.ti-rfid.com OMAP Mobile Processors www.ti.com/omap Wireless Connectivity www.ti.com/wirelessconnectivity TI E2E Community Home Page www.ti.com/video e2e.ti.com Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265 Copyright (c) 2011, Texas Instruments Incorporated