Bridge Rectifier
Page <1> 06/07/11 V1.1
www.element14.com
www.farnell.com
www.newark.com
WOBM
Features:
Glass passivated.
Surge overload rating -60 amperes peak.
Ideal for printed circuit board.
Reliable low cost construction utilizing moulded plastic technique
results in expensive product.
Mounting position : Any.
Lead : Sliver plated copper lead.
Dimensions : Inches (Millimetres)
Reverse Voltage - 600 V
Forward Current - 2 Amperes
Bridge Rectifier
Page <2> 06/07/11 V1.1
www.element14.com
www.farnell.com
www.newark.com
Note : 1. Measured at 1 MHz and applied reverse Voltage of 4 V dc.
Ambient Temperature (°C)
Forting Curve Output Rectified Current
Average Forward Output
Current Amperes
Maximum Non-Repetitive Peak Forward
Surge Current
Number of Cycles at 60 Hz
Peak Forward Surge Current,
Amperes
Rating and Characteristics Curves
Maximum Ratings and Electrical Characteristics
Rating at 25°C ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
Characteristics Symbol 2W06MG Unit
Maximum Recurrent Peak Reverse Voltage VRRM 600
VMaximum RMS Bridge Input Voltage VRMS 420
Maximum DC Blocking Voltage VDC 600
Maximum Average Forward
Rectified Current at TA= 25°C I(AV) 2
A
Peak Forward Surge Current, 8.3 ms Single
Half Sine-wave Super Imposed on Rated Load IFSM 60
I2t Rating for Fusing (t < 8.3 ms) I2t15 A2s
Maximum Forward Voltage Drop Per Element at 2 A Peak VF1.1 V
Maximum Reverse Current at Rated TJ = 25°C
DC Blocking Voltage TJ= 100°C IR10
1
µA
mA
Typical Junction Capacitance Per Element (Note 1) CJ30 pF
Operating Temperature Range TJ-55 to +150 °C
Storage Temperature Range TSTG
Bridge Rectifier
Page <3> 06/07/11 V1.1
www.element14.com
www.farnell.com
www.newark.com
Important Notice : This data sheet and its contents (the "Information") belong to the members of the Premier Farnell group of companies (the "Group") or are licensed to it. No licence is granted for the use of
it other than for information purposes in connection with the products to which it relates. No licence of any intellectual property rights is granted. The Information is subject to change without notice and replaces
all data sheets previously supplied. The Information supplied is believed to be accurate but the Group assumes no responsibility for its accuracy or completeness, any error in or omission from it or for any use
made of it. Users of this data sheet should check for themselves the Information and the suitability of the products for their purpose and not make any assumptions based on information included or omitted.
Liability for loss or damage resulting from any reliance on the Information or use of it (including liability resulting from negligence or where the Group was aware of the possibility of such loss or damage arising)
is excluded. This will not operate to limit or restrict the Group's liability for death or personal injury resulting from its negligence. Multicomp is the registered trademark of the Group. © Premier Farnell plc 2011.
Rating and Characteristics Curves
Percent of Rated Peak Reverse Voltage
Typical Reverse Characteristics
Instantaneous Reverse Current,
Microamperes
Typical Forward Characteristics
Instantaneous Forward Voltage, Volts
Instantaneous Forward Current Amperes
Reverse Voltage, Volts
Typical Junction Capacitance Per Bridge Element
Capacitance, (pF)