Power Analyzer Accessories PA4000 & PA1000 No insertion losses High immunity to external electrostatic and magnetic fields interference Low noise on output signal Tektronix custom cable assembly included for easy connection to the PA4000 power analyzer Compatible with optional PA4000 internal transducer supply (except CT-1000-S; order optional external power supply, Keithley model 2220) Fixed core Hall-effect transducers Tektronix provides a variety of fixed core and split core current transducers matched to our power analyzers to fit your application and measurement needs. Fixed core transducers provide the highest accuracy available for both AC and DC current measurements, whilst the split core devices are ideally suited to making measurements in less accessible applications. Applications - Calibration Precision and high-stability inverters Energy measurement CT-xxxx-M Series CT-xxxx-S Series The CT-xxxx-M series are designed for general purpose measurement applications where accuracy requirements are less stringent. These transducers are sourced from LEM, a high-quality component company. The CT-xxxx-S series offer the highest accuracy and linearity when uncompromised measurements are required. These transducers are sourced from LEM, a high-quality component company. Features - Very high accuracy (<0.035%) Excellent linearity (<20 ppm) Extremely low temperature drift (<2.5 ppm/K) Wide frequency bandwidth (DC to 100 kHz) Closed loop (compensated) current transducer using an extremely accurate zero flux detector Electrostatic shield between primary and secondary circuit Features - Very good accuracy (0.4 to 0.6%) Very good linearity (<0.1%) Wide frequency bandwidth (DC to 150 kHz) Closed loop (compensated) current transducer using the Hall Effect Insulated plastic case recognized according to UL 94-V0. Low temperature drift Compatible with optional PA4000 internal transducer supply Tektronix custom cable assembly included for easy connection to PA4000 www.tektronix.com 1 Datasheet No insertion losses High immunity to external interference Applications - AC variable speed drives and servo motor drives Static converters for DC motor drives Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Current clamps Applications - Measuring in breaker panels Low-power industrial loads HVAC CL1200 The CL1200 is an AC current clamp designed for use in industrial and higher power environments. The ergonomic design allows it to easily clamp onto cables or small bus bars. Features - 100 mARMS to 1200 ARMS measurement range 1000:1 transform ratio 30 Hz to 5 kHz response 0.5% to 1.5% accuracy, based on primary signal level Conforms to EN61010, 600 V Cat. III safety standard Low phase shift for power measurements Applications - Motor drive measuring Industrial loads Waveform analysis Measurement accessories For quick connections in an environment where it is not possible to break the current path, a current clamp offers an easy way to measure AC current. The CL series current clamps are sourced from AEMC. These accessories help to simplify your circuit connections and make your measurement tasks easier. Test Leads CL200 The CL200 is the latest in compact AC current probes. It is designed to provide quick connection to medium current circuits often found in industrial applications. Features - 0.5 ARMS to 240 ARMS measurement range 1000:1 transform ratio 40 Hz to 10 kHz response 1.0% to 3.0% accuracy, based on primary signal level Small, compact size Connects directly to Tektronix power analyzers Large jaw opening accommodates conductors up to 250 MCM Designed to EN61010, 600 V Cat. III safety standard 2 www.tektronix.com PA-LEADSET Replacement lead set for Tektronix power analyzers. This insulated test lead set is rated for 1000 V, 32 A, CAT II, and is UL61010 compliant. Power Analyzer Accessories BB1000 Breakout Box The BB1000 Breakout Box makes wiring connections between your deviceunder-test and Tektronix power analyzers easy and safe, by 'breaking out' the current flow for connection to the internal current shunt in the analyzer. It provides a line output socket to power your device under test (up to 10 ARMS) and 4 mm sockets for direct connection to the Tektronix power analyzer terminals. The BB1000 Breakout box is offered in three different versions with these receptacle styles: BB1000-NA: 120 V North America receptacle BB1000-EU: 240 V Euro receptacle BB1000-UK: 240 V United Kingdom receptacle BALLAST-CT BB1000-NA Breakout Box BALLAST-CT BB1000-EU Breakout Box The Tektronix Ballast-CT simplifies the measurement of output power and tube current in high frequency electronic lighting ballasts. This device is specifically designed for lighting applications, and overcomes problems that are usually found when using conventional or Hall Effect current transformers. When used in conjunction with a Tektronix PA1000 or PA4000 power analyzer, the free-standing Ballast-CT accessory provides a convenient and accurate solution to taking power measurements in lighting ballast circuits. Convenience: No need to feed cables through a CT core High accuracy: Trifilar-wound toroidal design No cable positioning/contact error Wide bandwidth: High frequency design provides 5 kHz to 1 MHz bandwidth Wide current range: 5 mA to 1 A is compatible with many modern ballasts BB1000-UK Breakout Box www.tektronix.com 3 Datasheet Specifications All specifications are subject to change without notice. CT-xxxx-S Series Model Nominal Nominal Nominal Supply voltage primary current primary current secondary (rms) (Ip, DC) current (Is, rms) Supply consumption Transform ratio Accuracy Bandwidth CT-60-S 42 A 60 A 100 mA 15 V 80 mA + Is 1:600 <270 ppm DC to 100 kHz CT-200-S 141 A 200 A 200 mA 15 V 80 mA + Is 1:1000 <83 ppm DC to 100 kHz CT-400-S 282 A 400 A 200 mA 15 V 80 mA + Is 1:2000 <43 ppm DC to 100 kHz CT-1000-S 707 A 1000 A 1A 15 V 80 mA + Is 1:1000 <53 ppm DC to 100 kHz Notes: The CT-1000-S transducer requires a separate power supply. We recommend the Keithley model 2220, which can supply power for up to two CT-1000-S current transducers. The secondary current (Is) = Imeasured x the transform ratio. CT-xxxx-M Series Model Nominal Nominal Nominal primary current primary current secondary (rms) (peak) current (rms) Supply voltage Supply consumption Transform ratio Accuracy Bandwidth CT-100-M 100 A 200 A 100 mA 12 V to 15 V 17 mA + Is 1:1000 0.5% DC to 100 kHz CT-200-M 200 A 420 A 100 mA 12 V to 15 V 17 mA + Is 1:2000 0.5% DC to 100 kHz CT-500-M 500 A 800 A 100 mA 15 V to 24 V 24 mA + Is 1:5000 0.6% DC to 100 kHz CT-1000-M 1000 A 1500 A 200 mA 15 V to 24 V 28 mA + Is 1:5000 0.4% DC to 150 kHz CL Series Model Measurement range Transform ratio Supply voltage Accuracy Bandwidth CL200 0.5 A - 240 ARMS 1000:1 Not needed 1.0% - 3.0% 40 Hz - 10 kHz CL1200 100 mA - 1200 ARMS 1000:1 Not needed 0.5% - 1.5% 30 Hz - 5 kHz Ballast-CT Operating current range 5 mA to 1 ARMS Operating frequency 5 kHz to 1 MHz Accuracy Amplitude Better than 1% (up to 500 kHz) Phase Better than 1 degree (up to 500 kHz) Maximum voltage, tube/ballast to output or Earth 600 VRMS, CAT II Isolation, tube/ballast to output 1 kVAC 4 www.tektronix.com Power Analyzer Accessories Ordering Information Models CT-S Series CT-60-S, CT-200-S, CT-400-S, CT-1000-S CT-M Series CT-100-M, CT-200-M, CT-500-M, CT-1000-M CL Series CL200, CL1200 Test Leads PA-LEADSET Breakout Box BB1000-NA, BB1000-EU, BB1000-UK Ballast-CT BALLAST-CT Accessories All CT series current transducers (except for CT-1000-S) include cabling that allows easy and direct connection to the optional 15 V supply on the PA4000, and directly to the 1 A shunt. The CT-1000-S transducer requires a separate power supply. We recommend the Keithley model 2220, which can supply power for up to two CT-1000-S current transducers. Warranty All parts warranted for 1 year. Tektronix is registered to ISO 9001 and ISO 14001 by SRI Quality System Registrar. www.tektronix.com 5 Datasheet ASEAN / Australasia (65) 6356 3900 Belgium 00800 2255 4835* Central East Europe and the Baltics +41 52 675 3777 Finland +41 52 675 3777 Hong Kong 400 820 5835 Japan 81 (3) 6714 3010 Middle East, Asia, and North Africa +41 52 675 3777 People's Republic of China 400 820 5835 Republic of Korea 001 800 8255 2835 Spain 00800 2255 4835* Taiwan 886 (2) 2722 9622 * European toll-free number. If not accessible, call: +41 52 675 3777 Austria 00800 2255 4835* Brazil +55 (11) 3759 7627 Central Europe & Greece +41 52 675 3777 France 00800 2255 4835* India 000 800 650 1835 Luxembourg +41 52 675 3777 The Netherlands 00800 2255 4835* Poland +41 52 675 3777 Russia & CIS +7 (495) 6647564 Sweden 00800 2255 4835* United Kingdom & Ireland 00800 2255 4835* Balkans, Israel, South Africa and other ISE Countries +41 52 675 3777 Canada 1 800 833 9200 Denmark +45 80 88 1401 Germany 00800 2255 4835* Italy 00800 2255 4835* Mexico, Central/South America & Caribbean 52 (55) 56 04 50 90 Norway 800 16098 Portugal 80 08 12370 South Africa +41 52 675 3777 Switzerland 00800 2255 4835* USA 1 800 833 9200 Updated 10 April 2013 For Further Information. Tektronix maintains a comprehensive, constantly expanding collection of application notes, technical briefs and other resources to help engineers working on the cutting edge of technology. Please visit www.tektronix.com. Copyright (c) Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. Specification and price change privileges reserved. TEKTRONIX and TEK are registered trademarks of Tektronix, Inc. All other trade names referenced are the service marks, trademarks, or registered trademarks of their respective companies. 04 Dec 2013 www.tektronix.com 55W-29381-1