Corporate: www.cdtechno.com Product: www.cdpoweronline.com VKA150MS 150 Watt Single Output Half Brick DC/DC Converter 33 - 75V Input Range ! High Efficiency: 85% Typical at 5V ! 100S Transient Response 50100% Load Step ! 420 kHz Fixed-Frequency Operation ! Remote Sense ! UL/CUL 1950, VDE EN60950 ! The VKA150MS Series DC/DC converters present an economical and practical solution for distributed power system architectures which require high power density and efficiency while maintaining system modularity and upgradeability. With the ability to operate over a wide input voltage range of 33 to 75 volts, these modules are ideal for use in battery backup applications common in todays' telecommunication and electronic data processing applications. The output is fully isolated from the input, allowing for a variety of polarity and grounding configurations. The VKA150MS's proprietary control circuitry responds to 50- Operation to +100C Baseplate Temperature ! Primary Remote On/Off, Choice of Pos/Neg Logic ! Adjustable Output Voltage ! Continuout Short-Circuit Protection ! Thermal Shutdown ! Case Ground Pin ! 100% load steps in 100Seconds to within 1% nominal Vout. The patented fixed frequency architecture combined with surface mount technology results in a compact, efficient and reliable solution to DC/DC conversion requirements. Safety approvals per UL/CUL 1950, EN 60950 PRODUCT SELECTION CHART MODEL ORDERING INFORMATION VKA150MS05 VKA150MS12 VKA150MS15 VKA150MS24 INPUT VOLTAGE 48VDC 48VDC 48VDC 48VDC VOUT (VDC) 5.0V 12.0V 15.0V 24.0V IOUT (A) 30.0 12.5 10.0 6.25 VKA150 MSzz Device Family Indicates 150 Watt Regulated Unit Model Number Selected from Table of Electrical Characteristics Where: zz = Output Voltage (05=5V, 12=12V,15=15V,etc.) Lead Length 0.200" - No Number 0.145" - (6) 0.110" - (8) Remote On-Off Logic: Positive - No Number Negative - (1) VKA150MS Rev C 1/2003 EFFICIENCY MIN 84 88 88 89 TYP 85 89 89 90 SPECIFICATIONS, ALL MODELS Specifications are at TCASE = +40C Nominal Input Voltage unless otherwise specified. INPUT PARAMETER INPUT Voltage Range Maximum Input Current Reflected Ripple Current Input Ripple Rejection No Load Input Current MS Power Dissipation MS No Load Standby, Primary On/Off Disabled MS Inrush Charge Quiescent Operating Current Primary On/Off Disabled OUTPUT PARAMETER OUTPUT Rated Power Set point Accuracy Line Regulation Load Regulation Output Temperature Drift Output Ripple, p-p Output Current Limit Inception Output Short-Circuit Current Output Overvoltage Limit Transient Response Peak Deviation Settling Time GENERAL PARAMETER ISOLATION Input to Output Input to Baseplate Output to Baseplate Resistance Capacitance Leakage Current GENERAL Switching Frequency Remote Sense Compensation Output Voltage Adjust Range Remote On/Off Control Inputs Primary Sink Current-Logic Low Vlow Vhigh Turn-on Time Weight TEMPERATURE Operation/Specification Storage Shutdown Temperature Thermal Impedance, case-ambient Lead Solder Temperature NOTES: (1) (2) (3) (4) (5) CONDITIONS MIN VIN = 30VDC Peak - Peak DC to 1KHz TYP MAX UNITS 48 75 6.6 550 60 100 VDC A mA dB mA 4.8 W 50 0.4 VIN = VINmax 0.360 8 CONDITIONS MIN High Line to Low Line No Load to Rated Load TYP UNITS 150 1 0.05 0.5 .05 1.5% 130% 135% 140% W % % % %/C VOUT, Nom lOUT, Nom lOUT, Nom VOUT, Nom 2 75 3% 100 VOUT, Nom Sec TYP MAX DC to 20MHz BW 105% 120% 120% 50 to 100% Load Step di/dt = 0.1A/Sec VOUT, 1% of Nominal Output MIN Peak Test for 2 Seconds 1500 1500 500 10 400 5V 12V 15V 24V 420 -40% -50% -50% -50% / / / / UNITS VDC VDC VDC M pF A, rms 2000 180 VISO = 240VAC, 60Hz mA MAX 0.02 0.2 .02 CONDITIONS 12 W mC 440 0.5 KHz V VOUT, Nom VOUT, Nom VOUT, Nom VOUT, Nom 1.0 0.4 Open Collector 8.0 3 (85) mA V +10% +10% +10% +10% Open Collector/Drain Within 1% of Rated Output 5.0 Case Temperature Case Temperature Case Temperature -40 -55 +100 +25 +25 +100 +125 +115 8.2 10 Seconds max +300 mSec oz (g) C C C C/W C See Typical Performance Curves, page 3 Continuous Mode See graphs for Efficiency vs. Output Load, VIN, TCASE 3.3V Models Limited in Trim Down Range Consult Factory for Details Product: www.cdpoweronline.com VKA150MS Rev C 1/2003 2 MECHANICAL NOTES: All dimensions are in inches (millimeters). PIN PLACEMENT TOLERANCE: 0.005" 0.530 MAX [13.46] MECHANICAL TOLERANCE: 0.015" Marked with: specific modeL ordered, date code, job code. 0.20 [5.1] .040 [1.02] DIA. 7 PLACES MATERIAL: Units are encapsulated in a low thermal resistance molding compound which has excellent chemical resistance and electrical properties in high humidity environments and over a wide operating temperature range. The encapsulant and outer shell of the unit have UL94V-0 ratings. Lead material is solder plated to allow ease of solderability. .081 [2.06] DIA. 2 PLACES 0.20 [5.1] 0.50 [12.7] .400 [10.16] 0.40 [10.16] 2.000 [50.80] 2.40 [61.0] MAX 0.700 [17.78] VKA150MS 1.000 [25.40] 1.000 [25.40] 1.400 [35.56] 1.400 [35.56] MOUNTING INSERTS M3 X 0.5 THRU, 4 PLACES MAX. TORQUE, 8 IN/LBS 1.900 [48.26] 0.19 [4.8] 2.28 [57.91] MAX OUTPUT ADJUST VOLTAGE OVP NOTE This feature allows the user to accurately adjust the module's output voltage set point to a specified level. This is achieved by connecting a resistor or potentiometer from the TRIM terminal to either the +Vout terminal (for increased Vout) or the -Vout terminal (for decreased Vout). The formulae below describe the trim resistor value to obtain a Vout change of %. VO is output voltage prior to adjustment (3.3V, 5V, 12V, 15V, or 24V). Radj - up = ( Radj - down = Vo(100 + %) 1.225 % (100 - 2) % _ (100 + 2%) % Special attention should be given to the peak voltage deviation during a dynamic load step when trimming the output above the original set point to avoid tripping the overvoltage protection circuit. Should an OVP condition occur, the converter will go into a latch condition and must be externally reset before it will return to normal operation. ) k k Product: www.cdpoweronline.com VKA150MS Rev C 1/2003 3 Power Electronics Division, Americas 3400 E Britannia Drive, Tucson, Arizona 85706 Tel: 800.547.2537 Fax: 520.295-4197 C&D Technologies, EMEA/AP Milton Keynes MK14 5BU UK Tel: +44 (0)1908 615232 Fax: +44 (0)1908 617545 Any data, prices, descriptions or specifications presented herein are subject to revision by C&D Technologies, Inc. without notice. While such information is believed to be accurate as indicated herein, C&D Technologies, Inc. makes no warranty and hereby disclaims all warranties, express or implied, with regard to the accuracy or completeness of such information. Further, because the product(s) featured herein may be used under conditions beyond its control, C&D Technologies, Inc. hereby disclaims all warranties, either express or implied, concerning the fitness or suitability of such product(s) for any particular use or in any specific application or arising from any course of dealing or usage of trade. The user is solely responsible for determining the suitability of the product(s) featured herein for user's intended purpose and in user's specific application. C&D Technologies, Inc. does not warrant or recommend that any of its products be used in any life support or aviation or aerospace applications. Product: www.cdpoweronline.com VKA150MS Rev C 1/2003 4