2019-03/18
MB1F
THRU
MB10F
MB1F MB2F MB4F MB6F MB8F MB10F
100 200 400 600 800 1000
100 200 400 600 800 1000
70 140 280 420 560 700
30
64
0.8 A DC
REV:F
3.74
30
MB1F MB2F MB4F MB6F MB8F MB10F
100
0.8
0.8
0.5
Maximum Average Forward Rectified Current T
A
=125
o
C
T
A
=110
o
C
39
MB-F
Unit:mm
27.3
10
*
* P/N suffix V means Halogen-free
P/N suffix V means AEC-Q101 qualified, e.g:MB1FV
@T
A
=150
o
C
@T
A
=25
o
C
NOTES:
Typical ThermalResistance(Note2)
1.Typical Thermal Resistance : At 9.5mm lead lengths,PCB mounted.
uAmps
1.0
2mAmps
1.1
- +
~ ~
Max0.2
3.6-4.1
0.15-0.4
4.5-5.0
6.4-7.0
0.5-1.1
1.3-1.7
1.0-1.6
2.3-2.7
Max1.8
INSTANTANEOUS FORWARD VOLTAGE, (V)
PERCENT RATED PEAK REVERSE VOLTAGE, (%)
),UR (A
T
NERWDCROSAROFUENA
ISTNA
TN
0
0.01
0.1
1
10
A(E),RRAWR RDU TNCGE FORAV AE
0
5
10
15
20
25
30
2.01.50.5 1.0 2.5
10040 602010
1
0
0.1
1.0
1000
10000
4020 60 80 100 120 140
RATING AND CHARACTERISTICS CURVES ( MB1F THRU MB10F )
FIG..3
MAXIMUM
REVERSE CHARACTERISTICS
FIG.
.2
MAXIMUM
INSTANTANEOUS
FORWARD CHARACTERISTICS
AMBIENT TEMPERATURE, (
O
C)
u(,TNCAERURE )ESRRVENAATSNOEUSTIN
20
0
0.8
1.2
1.6
8040 60 100 120 140 150
NUMBER OF CYCLES AT 60Hz
)A(,TNERRUCEGRUSDRAWROFKAEP
8.3mS Single Half Sine-Wave
JEDEC Method
FIG. 1 MAXIMUM NON-REPETITIVE
FORWARD SURGE CURRENT
T
J
=25
O
C
Pulse Width = 300mS
1% Duty Cycle
T
A
=150
O
C
60 Hz RESISTIVE OR
INDUCTIVE LOAD
1.0
0.6
0.4
0.2
1.4
T
A
=25
O
C
0.5
FIG..4
TYPICAL FORWARD CURRENT
DERATING CURVE
M B X F
100V 600V
400V
200V 8------ 800V
10----- 1000V
Mounting Pad Layout
Dimensions in inches and (millimeters)
.276 Max.
(7.0 Max.)
.035 Min.
(0.90 Min.)
.030 Min.
(0.76 Min.)
.105 (2.67)
.095 (2.41)
PACKAGING OF DIODE AND BRIDGE RECTIFIERS
REEL PACK
PACKAGE GROSS
WEIGHT(Kg)
EA PER
REEL
COMPONENT
SPACE TAPE SPACE
(mm)
CARTON SIZE
(mm) (mm)
EA PER
CARTON
REEL DIA
MB-F 5,000 330 360*335*360 80,000 25.83
PACKING
CODE
(mm)
EA PER
BOX
10,000
INNER
-W
Rectron Inc reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. Rectron Inc or anyone on its behalf assumes no responsibility or liabi-
lity for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" paramet-
ers which may be included on RECTRON data sheets and/ or specifications ca-
n and do vary in different applications and actual performance may vary over ti-
me. Rectron Inc does not assume any liability arising out of the application or
use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical,
life-saving implant or other applications intended for life-sustaining or other rela-
ted applications where a failure or malfunction of component or circuitry may di-
rectly or indirectly cause injury or threaten a life without expressed written appr-
oval of Rectron Inc. Customers using or selling Rectron components for use in
such applications do so at their own risk and shall agree to fully indemnify Rect-
ron Inc and its subsidiaries harmless against all claims, damages and expendit-
ures.
DISCLAIMER NOTICE