SERIES POWER ENTRY MODULE EMI FILTERS INTRODUCTIONS SPECIFICATIONS 1. AR series is designed as a high performance, two-stage filter for low impedance load with better noise attenuation than AK series in low frequency applications such as switching power supplies. 2. Fuse holder designed for one IEC 5x20mm fuse. Safety interlock prevents fuse removal with line plug inserted (Use only with 250V fuse). 3. All part numbers are UL recognized, CSA certified and VDE approved. 1. Maximum leakage current each line-to-ground @ 115VAC 60Hz: 0.25mA @ 250VAC 50Hz: 0.45mA 2. Hipot rating (one minute) line-to-ground: 2250VDC line-to-line: 1450VDC 3. Operating frequency: 50/60Hz 4. Rated voltage: 115/250VAC COMPONENTS PART NO. 03AR1/2/3 03AR2D/3D 06AR1/2/3 06AR2D/3D 06AR4 V D E MINIMUM INSERTION LOSS IN dB C1 (uF) L1 (mH) L2 (mH) Cy (pF) 0.1 1.5 9 2200 0.033 9 1.5 0.1 0.7 2.5 0.015 2.5 0.7 3300 0.1 0.7 2.5 COMMON MODE (L-G) IN 50 OHM SYSTEM CURRENT FREQUENCY-MHz RATING .15 .50 1.0 5.0 10 03AR 40 60 60 45 40 06AR 34 55 56 40 35 06AR2D,3D 34 60 60 45 40 DIFFERENTIAL MODE (L-L) IN 50 OHM SYSTEM 03AR 6 45 55 50 45 06AR 5 25 60 50 45 06AR2D,3D 10 10 50 50 45 R( ) 1M 2.2M 30 30 25 30 40 35 40 ELECTRICAL SCHEMATIC AR3/4 ONLY AR1/4 WITHOUT POWER SW AR3D ONLY L' L L F SW1 Cy C1 R C2 C3 I L L F SW1 O L1 E N G A C1 E G' FIG. B C3:0.1uF TYPE & RATED CURRENT DELTA PART NO. RATED CURRENT 115VAC 250VAC IEC CONNECTOR FUSE HOLDER POWER SWITCH VOLTAGE SELECTOR SW ELECTRICAL SCHEMATIC AR1 6A 6A FIG. A C3 L2 Cy N G FIG. A C2:0.1uF R C2 AR2 6A 6A AR2D 6A 4A AR3 6A 5A AR3D 6A 4A AR4 6A 6A SP1 DP2 FIG. A FIG. B SP1 REAR3 FIG. A DP2 REAR3 FIG. B REAR3 FIG. A 1. Single-pole UL, CSA & VDE approved, VDE-6A at 250VAC. Electrical lifetime: 50,000 cycles. Maximum inrush current: 50A. 2. Double-pole UL, CSA & VDE approved, VDE-4A at 250VAC. Electrical lifetime: 10,000 cycles. Maximum inrush current: 50A. 3. Voltage selector SW -UL, CSA & VDE approved Current rating: 10A at 125VAC; 5A at 250VAC. 4-3 L O L1 N N' D Cy Cy I L2 N POWER ENTRY MODULE FILTERS L' L A N' D G' Suggested thickness of mounting panel is from 0.04 to 0.07 inch suggest mounting cutout 27.0 1.063 0.003 R0.04Max. 1.0 2.6 0.003 66.0 2.65 67.3 O G N I L 2.17 55.1 2.38 60.5 1.15 29.2 MECHANICAL CONSTRUCTION 2.57 65.3 1.059 26.9 N G L AR2, AR2D O G N I L 2.60 66.0 1.15 29.2 2.65 67.3 POWER ENTRY MODULE FILTERS AR3, AR3D AR4(without power switch) 0.65 16.5 115V G 1.059 26.9 29.2 G N L 2.17 55.1 2.24 56.9 1.15 2.65 67.3 G AR1 2.57 65.3 4-4 1.059 26.9 UNIT: INCH mm