Optical Connectivity Cable Assemblies Components Accessories www.AFLtele.com * 1.800.235.3423 Table of Contents Cable Assemblies Components and Accessories Simplex Cable Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 LC, SC and ST Field MasterTM Connectors . . . . . . . . . . . . . . . . . .20 Duplex Cable Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Fast SC and ST Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 Quad Cable Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 Plastic Optical Fiber Data Link System . . . . . . . . . . . . . . . . . . . . .22 MTP(R) Cable Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 Precision Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23 Connectorized Jacketed Ribbon Assemblies. . . . . . . . . . . . . . . . . .9 SC Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24 Circular Premise Cable Assemblies . . . . . . . . . . . . . . . . . . . . . . .10 SC Shuttered Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24 Loose Tube and Riser Rated Indoor/Outdoor Cable Assemblies . . .11 LC Adapters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25 LightLinkTM Fiber Receiver Service Cable . . . . . . . . . . . . . . . . . . .13 MTP(R) Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25 Advanced Fiber Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 Hybrid Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25 Lensed Fiber Technology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 FC Adapters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 Hermetic Fiber Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 ST Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 Polarization Maintaining (PM) Assemblies . . . . . . . . . . . . . . . . . .19 MT-RJ Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 Buildout-Style Attenuators . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 SC and FC Optical Terminators . . . . . . . . . . . . . . . . . . . . . . . . . .28 Loopback Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28 Field MasterTM Tool Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29 Loose Tube Fanout Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 Adapter Cleaners . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31 Cletop Ferrule Cleaner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31 Connector/Adapter Cleaning Kit . . . . . . . . . . . . . . . . . . . . . . . . .32 MPO Cleaner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32 Planar Couplers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33 Wideband Couplers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34 Wavelength Division Multiplexer Couplers . . . . . . . . . . . . . . . . . .35 Optical FTTP Coupler Module . . . . . . . . . . . . . . . . . . . . . . . . . . .36 Optical FTTP WDM Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37 Coarse WDM Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38 Optical Coupler Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39 Ruggedized Wideband Couplers . . . . . . . . . . . . . . . . . . . . . . . . .40 4Q05 1 Simplex Cable Assemblies SC Cable Assemblies SC cable assemblies are designed for the most advanced fiber optic systems providing exceptional stability and low reflection (single-mode). SC cable assemblies are well suited for high-density applications. The SC connector uses a rectangular, molded design for quick, easy push-pull installation. This design prevents ferrule rotation and axial damage on the fiber contact points, reducing the potential for damage from mechanical vibration. Features * 2.5mm ferrule, pull-proof design * Available as a duplex connector, compliant to requirements of TIA/EIA and Fibre-Channel standards * Meets or exceeds Telcordia GR-326 * Ceramic ferrule for durability * 8 Angled PC polish for single-mode Specifications MULTIMODE SINGLE-MODE PARAMETER VALUE PARAMETER VALUE Insertion Loss < 0.20dB Insertion Loss < 0.50dB Return Loss > -30dB Operating Temperature -40C to +85C Return Loss UPC APC > -55dB > -65dB Operating Temperature -40C to +85C ST Cable Assemblies The ST connector's nonslip housing makes installation quick and easy. The bayonet style coupling uses a convenient push-twist-and-lock method for easy mounting and is keyed to ensure easy alignment. The ST connector provides durable, quick, economical and reliable terminations. Features * Metallic housing for both single-mode and multimode * Single twist bayonet coupling * Ceramic ferrule * Black boot for multimode; blue boot for single-mode Specifications SINGLE-MODE MULTIMODE PARAMETER VALUE PARAMETER VALUE Insertion Loss < 0.20dB Insertion Loss < 0.50dB Return Loss > -55dB Return Loss > -30dB Operating Temperature -40C to +85C Operating Temperature -40C to +85C (c) 2002, AFL Telecommunications, all rights reserved. Revision 0, 4.01.05 Specifications are subject to change without notice. 2 Simplex Cable Assemblies FC Cable Assemblies The FC connector's cylindrical nonslip surface allows for fast and easy installation while the keyed, threaded metallic coupling provides durable, reliable connections. A spring loaded, pull-proof zirconia ferrule optimizes performance and prevents rotational damage during mating and disconnections. Standard boot colors are green (angled single-mode), blue (single-mode), and black (multimode). Features * Ultra Polish for single-mode * Angle polish for single-mode * Designed to meet Telcordia GR-326 * Rugged, metallic housing Specifications Multimode Single-mode PARAMETER VALUE PARAMETER VALUE Insertion Loss < 0.20dB Insertion Loss < 0.50dB > -55dB > -65dB Return Loss > -30dB Operating Temperature -40C to +85C Return Loss UPC APC Operating Temperature -40C to +85C LC Cable Assemblies - Simplex The LC connector reduces system cost by doubling the fiber density in shelves and outlets without sacrificing performance. Assemblies are manufactured and factory tested to provide the high performance link needed in today's high speed telephony, data, and broadband networks. Available in both single-mode (blue housing) and multimode (beige housing) versions. Features * Standard and custom configurations * Ultra PC polish for single-mode * Pull-proof design * Unique latching mechanism Specifications MULTIMODE SINGLE-MODE PARAMETER VALUE PARAMETER VALUE Insertion Loss < 0.20dB Insertion Loss < 0.50dB Return Loss > -55dB Return Loss > -30dB Operating Temperature -40C to +85C Operating Temperature -40C to +85C (c) 2002, AFL Telecommunications, all rights reserved. Revision 0, 4.01.05 Specifications are subject to change without notice. 3 Simplex Cable Assemblies MU Cable Assemblies - Simplex MU assemblies are very useful in many high-density applications. While the MU connector is 50% smaller than the SC connector, it maintains high optical performance. The MU's latchless design makes it the choice for backplane applications where blind-mating/ demating is required. In backplane applications where little demating is required and highdensity is the priority, MU-J is a useful alternative to the MU-A. Specifications Applications * * * * * * * Panel-Mount Board-Mount Amplifiers OADMs Optical Switches High Density Interconnect OEM Applications PARAMETER VALUE Insertion Loss < 0.25dB Return Loss > -55dB Operating Temperature -40C to +85C Ordering Information ASC ASC RS 001 Fiber Count Connector End A Connector End B Cable Type Single-mode ASC = Angle SC AFC = Angle FC USC = Ultra SC UFC = Ultra FC UST = Ultra ST ULC = Ultra LC UMA = Ultra MU UMJ = Ultra MU-J Single-mode ASC = Angle SC AFC = Angle FC USC = Ultra SC UFC = Ultra FC UST = Ultra ST ULC = Ultra LC UMA = Ultra MU UMJ = Ultra MU-J XXX = No connector RS = 3.0mm Riser PS = 3.0mm PLenum RM = 1.6m Riser PM = 1.6mm Plenum RT = 2.0mm Riser PT = 2.0mm Plenum JH = 900m Multimode PSC = SC MM PFC = FC MM PLC = LC MM PST = ST MM 1 = 001 Q Fiber Type Q = Single-mode R = Multimode 50/125 2 = Multimode 62.5/125 L = 10 Gigabit MM 50m 0010 Cable Length (meters) 0010 = 10 meters (specify length) Multimode PSC = SC MM PFC = FC MM PLC = LC MM PST = ST MM XXX = No connector (c) 2002, AFL Telecommunications, all rights reserved. Revision 0, 4.01.05 Specifications are subject to change without notice. 4 Duplex Cable Assemblies Zipcord Assemblies The zipcord tight-buffered cordage contains two tubes of fiber which are tight buffered with a 900m jacket. This construction is zipped apart to the desired length. These are connectorized on the 3mm, 2.0mm or 1.6mm assembly. Connectors can be duplexed with clips. Dual-Link Cable Assemblies Dual-link connectorized assemblies consist of 2.85mm outer jacket with two PVC 900m coated fibers, connectorized on the 900m legs. Standard length of this breakout is 1/2 meter. If an application requires 3.0mm furcation, use of a zipcord assemby is recommended. MT-RJ Assemblies MT-RJ assemblies are ideally suited for high-density applications, doubling the fiber count in shelves and outlets. The MT-RJ is very cost effective allowing the number of ports to be doubled without doubling the cost of the electronics. The compact two fiber connector features a snag-proof latching mechanism for worry free installation. Features Specifications * Two-fiber, dual connect, single ferrule design * Multimode and single-mode performance to TIA specifications * RJ-style snag-free latch MT-RJ SINGLE-MODE MULTIMODE Return Loss < -35dB -20dB Insertion Loss < 0.50dB < 0.50dB (c) 2002, AFL Telecommunications, all rights reserved. Revision 0, 10.05.05 Specifications are subject to change without notice. 5 Duplex Cable Assemblies Ordering Information UST UST RD 002 Fiber Count Connector End A Connector End B Cable Type Single-mode ASC = Angle SC AFC = Angle FC USC = Ultra SC UFC = Ultra FC UST = Ultra ST ULC = Ultra LC USF = Ultra SC Duplex UDL = Ultra LC Duplex SJF = MT-RJ Female SJM = MT-RJ Male Single-mode ASC = Angle SC AFC = Angle FC USC = Ultra SC UFC = Ultra FC UST = Ultra ST ULC = Ultra LC USF = Ultra SC Duplex UDL = Ultra LC Duplex SJF = MT-RJ Female SJM = MT-RJ Male XXX = No connector RZ = 3.0mm Riser Zipcord 002 = 2 PZ = 3.0mm Plenum Zipcord R20Z = 2.0mm Riser Zipcord P20Z = 2.0mm Plenum Zipcord R16Z = 1.6mm Riser Zipcord P16Z = 1.6mm Plenum Zipcord RD = Riser Dual Link PD = PLenum Dual Link R7 = Riser Ribbon (for MT-RJ only) P7 = Plenum Ribbon (for MT-RJ only) Multimode PSC = SC MM PFC = FC MM PLC = LC MM PST = ST MM PSF = SC Duplex MM PDL = LC Duplex MM PJF = MT-RJ Female MM PJM = MT-RJ Male MM Q Fiber Type Q = Single-mode R = Multimode 50/125 2 = Multimode 62.5/125 L = 10G Laser Link 300 0010 Cable Length (meters) Clip Type XXXX (specify length) 0010 = 10 meters HLA = High Metal, Low Profile HHA = High Metal, High Profile LLA = Low Metal, Low Profile LHA = Low Metal, High Profile (Only Applies To Duplex SCs) Multimode PSC = SC MM PFC = FC MM PLC = LC MM PST = ST MM PSF = SC Duplex MM PDL = LC Duplex MM PJF = MT-RJ Female MM PJM = MT-RJ Male MM XXX = No connector * single connector options, quantity two per end (c) 2002, AFL Telecommunications, all rights reserved. Revision 0, 10.05.05 Specifications are subject to change without notice. 6 Quad Cable Assemblies Quad cable assemblies are available in a wide variety of configurations. Custom assemblies are available to fit exact application needs. Quad assemblies are offered using four 900m coated fibers in one circular cable featuring a 4.9mm outer diameter. Applications Specifications * Loaded Panels * Communications Closets * Routing between Communications Closets and Equipment Rooms * FDF to FOT PARAMETER VALUE Upjacketing or Furcation Length 500mm +/- 30mm; Diameter 2.4mm, 1.6mm for LC Hybrids 900m standard leg color codes 1 = Blue 2 = Orange 3 = Green 4 = Brown Ordering Information ASC Connector End A Single-mode ASC = Angle SC AFC = Angle FC USC = Ultra SC UFC = Ultra FC UST = Ultra ST ULC = Ultra LC USF = Ultra SC Duplex UDL = Ultra LC Duplex SJF = MT-RJ Female SJM = MT-RJ Male Multimode PSC = SC MM PFC = FC MM PLC = LC MM PST = ST MM PSF = SC Duplex MM PDL = LC Duplex MM PJF = MT-RJ Female MM PJM = MT-RJ Male MM ASC RQ 004 Q 0010 Connector End B Cable Type Fiber Count Fiber Type Cable Length (meters) Single-mode ASC = Angle SC AFC = Angle FC USC = Ultra SC UFC = Ultra FC UST = Ultra ST ULC = Ultra LC USF = Ultra SC Duplex UDL = Ultra LC Duplex SJF = MT-RJ Female SJM = MT-RJ Male XX = No connector RQ = Quad Riser PQ = Quad Plenum 004 = 4 Q = Single-mode R = Multimode 50/125 2 = Multimode 62.5/125 XXXX (specify length) 0010 = 10 meters NF Clip Type HLA = High Metal, Low Profile HHA = High Metal, High Profile LLA = Low Metal, Low Profile LHA = Low Metal, High Profile (Only Applies To Duplex SCs) Leg Diameter NN = Non-furcated, both ends 900m FF = Furcated both ends NF = 900m end A, Furcated end B Multimode PSC = SC MM PFC = FC MM PLC = LC MM PST = ST MM PSF = SC Duplex MM PDL = LC Duplex MM PJF = MT-RJ Female MM PJM = MT-RJ Male MM XX = No connector (c) 2002, AFL Telecommunications, all rights reserved. Revision 0, 10.05.05 Specifications are subject to change without notice. 7 MTP(R) Cable Assemblies MTP cable assemblies are designed for high-density and multi-fiber interconnect applications. These MTP terminations are most commonly used in fiber rich environments, where space is a premium. MTP cable assemblies provide a reliable interface for 8 and 12 fiber terminations. Assemblies include Patchcords, Pigtails and Fanouts. Applications * * * * * High Density Fiber Management LAN/WAN Premises DWDM & Switching (Network Elements) Back Plane Data Centers Features * Connectorized interface for ribbon/ ribbonized fiber * 8 and 12 fiber connector terminations and assemblies * Push-pull connector mating assures secure connections * Fully intermatable for MTP/MPO application * Precision Guide Pin assures fiber alignment at mating * Meets/exceeds Bellcore GR-1435 requirements * Most economical solution for masstermination of fiber Specifications SPECIFICATION MULTIMODE SINGLE-MODE .75dB .35dB .75dB .35dB Return Loss Not applicable -55dB Operating Temp -40C to +75C -40C to +75C Durability <0.3dB; 200 Insertions <0.3dB; 200 Insertions Standards Compliant IEC 1754-7 TIA/EIA 604-5 ANSI HIPPI 6400 IEC 1754-7 TIA/EIA 604-5 ANSI HIPPI 6400 Telcordia - 1435 Insertion Loss: Max Typical Ordering Information ATF USC Connector End A Connector End B Single-mode ATM = Angle Male MTP ATF = Angle Female MTP Single-mode ATM = Angle Male MTP ATF = Angle Female MTP XXX = No Connector ASC = Angle SC USC = Ultra SC ULC = Ultra LC UST = Ultra ST UFC = Ultra FC Multimode FTM = Male MTP FTF = Female MYP RR 012 Q Cable Type Fiber Count Fiber Type RR = Riser Jacketed Ribbon PR = Plenum Jacketed Ribbon CR = Bare Ribbon 008 = 8 012 = 12 Q = Single-mode R = Multimode 50/125 2 = Multimode 62.5/125 0010 N Cable Length (meters) Leg Diameter XXXX (specify length) 0010 = 10 meters F = Furcated End A / MTP End B N = 900m End A / MTP End B Multimode PSC = Physical SC PLC = Physical LC PST = Physical ST PFC = Physical FC FTM = Male MTP FTF = Female MYP XXX = No Connector (c) 2002, AFL Telecommunications, all rights reserved. Revision 0, 10.05.05 Specifications are subject to change without notice. 8 Connectorized Jacketed Ribbon Assemblies Connectorized jacketed ribbon assemblies feature up to 12 fibers in a ribbon structure offering a higher density configuration than conventional buffered designs. The connectorized jacketed ribbon assemblies are 100% tested, easily installed, and available in jumper, pigtail or hybrid configurations. Features * 4, 6, 8 and 12 fiber single-mode or multimode available * SC, FC, ST and LC Connector types * 1 meter breakout length (standard) * Breakouts available in 900m or 2.4mm furcated * LC breakouts available in 900m or 1.6mm furcated COLOR FURCATION - FIBER NUMBER REFERENCE 1 Blue 4 Brown 7 Red 10 Violet 2 Orange 5 Slate 8 Black 11 Rose 3 Green 6 White 9 Yellow 12 Aqua Ordering Information ASC ASC Connector End A Connector End B Single-mode ASC = Angle SC AFC = Angle FC USC = Ultra SC UFC = Ultra FC UST = Ultra ST ULC = Ultra LC Multimode PSC = SC MM PFC = FC MM PLC = LC MM PST = ST MM Single-mode ASC = Angle SC AFC = Angle FC USC = Ultra SC UFC = Ultra FC UST = Ultra ST ULC = Ultra LC XXX = No connector JR 012 Cable Type Fiber Count CR = Bare Ribbon RR = Riser Jacketed Ribbon PR = Plenum Jacketed Ribbon 004 = 4 006 = 6 008 = 8 012 = 12 Q Fiber Type Q = Single-mode R = Multimode 50/125 2 = Multimode 62.5/125 0010 NN Cable Length (meters) 0010 = 10 meters (specify length) Leg Diameter N = 900m End A / XXX End B NN = 900m End A and B F = Furcated End A / XXX End B FF = Furcated Ends A and B FN = Furcated Ends A / 900m End B NF = 900m End A / Furcated Ends B Multimode PSC = SC MM PFC = FC MM PLC = LC MM PST = ST MM XXX = No connector (c) 2002, AFL Telecommunications, all rights reserved. Revision 0, 10.05.05 Specifications are subject to change without notice. 9 Circular Premise Cable Assemblies High fiber count Circular Premise Cable (CPC) assemblies provide safe and cost effective installation for many applications. High fiber count assemblies help eliminate labor-intensive field termination, yet guarantee reliable performance. Featuring a unified construction allowing for easy fiber identification and rapid installation, these assemblies are built to exceed all TIA and Telcordia requirements. Features * Riser-rated is standard (plenum available) * Fiber counts up to 144 fibers with aramid yarn reinforcement for rugged protection * Highly flexible for ease of routing * Available with ST, SC, FC and LC connectors in both single-mode and multimode * Jumper, pigtail and hybrid configurations * Pre-installed pulling eye kits available on certain products up to 144 fiber * Standard breakout length is 1 meter (1/2 meter available as a nonstandard) * 900m legs or furcated 2.4mm legs available (1.6mm furcated for LC assemblies) Dimensions Ordering Information ASC ASC RC 012 Connector End A Connector End B Cable Type Fiber Count Single-mode ASC = Angle SC AFC = Angle FC USC = Ultra SC UFC = Ultra FC UST = Ultra ST ULC = Ultra LC Multimode PSC = SC MM PFC = FC MM PLC = LC MM PST = ST MM Single-mode ASC = Angle SC AFC = Angle FC USC = Ultra SC UFC = Ultra FC UST = Ultra ST ULC = Ultra LC XXX = No connector RC = Riser (CPC) PC = plenum (CPC) 006 = 6 012 = 12 024 = 24 036 = 36 048 = 48 072 = 72 096 = 96 144 = 144 Multimode PSC = SC MM PFC = FC MM PLC = LC MM PST = ST MM XXX = No connector Q Fiber Type Q = Single-mode R = Multimode 50/125 2 = Multimode 62.5/125 0010 NN Cable Length (meters) XXXX (specify length) 0010 = 10 meters Leg Diameter N = 900m End A / XXX End B NN = 900m End A and B F = Furcated End A / XXX End B FF = Furcated Ends A and B FN = Furcated Ends A / 900m End B NF = 900m End A / Furcated Ends B NOTE: Duplex SC and LC available (c) 2002, AFL Telecommunications, all rights reserved. Revision 0, 10.05.05 Specifications are subject to change without notice. 10 Loose Tube and Riser Rated Indoor/Outdoor Cable Assemblies High fiber count Loose Tube and Riser Rated Indoor/Outdoor Loose Tube Cable Assemblies provide a safe and proven method of utilizing preterminated connector technology for outside plant applications. These assemblies help control cost by eliminating labor-intensive field termination and provide the same factory terminated reliability the industry has trusted for many years. Cable assemblies are available in Outside Plant Loose Tube (LT) and Riser Rated Indoor/Outdoor Loose Tube (RL). RL cable is suitable for use in indoor and outdoor applications. Each unit is manufactured to exceed all TIA and Telcordia requirements. Applications Features * * * * * Fiber counts from 6 to 144 fibers * Available with ST, SC, FC, and LC connectors single-mode * Standard configuration is Pigtail (non-standard configurations available) * Pre-installed pulling eye kits available Outdoor Cabinets External-Building Runs Vaults CEV's. * Standard Breakout length is 1 meter * Standard furcation 2.4mm ST, SC, FC, 1.6mm LC * UV resistant outer jacket * Dry Core design * Meets Telcordia GR-20-CORE Specifications Riser Rated Indoor/Outdoor Loose Tube Cable Components Riser Rated stranded design loose tube cable is moisture and U.V. resistant, S-Z stranded for easy mid-span access, UL-listed type OFNR (UL1666) riser-rated, and can be used in both duct and lashed applications. Temperature Range PARAMETER PVC jacket strength member binder dry water blocking system dielectric center member optical fibers VALUE Operating -40C to +70C Storage -40C to +75C Installation 0C to +70C rip cord gel-filled buffer tube Loose Tube Cable Components Loose Tube stranded design cables feature fiber counts up to 432, compliance with EIA/TIA and REA/RUS PE-90, and are S-Z stranded for easy midspan access. Temperature Range PARAMETER Polyethylene jacket strength member VALUE Operating -40C to +70C coated corrugated steel armor Storage -40C to +75C dielectric center member optical fibers Installation binder 0C to +70C rip cord water blocking system gel-filled loose tube (c) 2002, AFL Telecommunications, all rights reserved. Revision 0, 10.05.05 Specifications are subject to change without notice. 11 Loose Tube and Riser Rated Indoor/Outdoor Cable Assemblies Dimensions Ordering Information ASC ASC LT 024 Q Connector End A Connector End B Cable Type Fiber Count Fiber Type Single-mode ASC = Angle SC AFC = Angle FC USC = Ultra SC UFC = Ultra FC UST = Ultra ST ULC = Ultra LC Single-mode ASC = Angle SC AFC = Angle FC USC = Ultra SC UFC = Ultra FC UST = Ultra ST ULC = Ultra LC XXX = No connector LT = Loose Tube RL = Riser Rated Indoor/Outdoor Loose Tube 006 = 6 012 = 12 024 = 24 036 = 36 048 = 48 072 = 72 096 = 96 144 = 144 216 = 216 Q = Single-mode 0010 NN Cable Length (meters) XXXX (specify length) 0010 = 10 meters Leg Diameter N = 900m End A / XXX End B NN = 900m End A and B F = Furcated End A / XXX End B FF = Furcated Ends A and B FN = Furcated Ends A / 900m End B NF = 900m End A / Furcated Ends B Lengths Available Cable lengths are dependent on fiber cable type and count. Consult customer service for maximum lengths available. (c) 2002, AFL Telecommunications, all rights reserved. Revision 0, 10.05.05 Specifications are subject to change without notice. 12 LightLinkTM Fiber Receiver Service Cable (FRSC) All FRSC cables are factory tested to meet stringent installation performance demands. This cable design makes splicing from an optical node to a closure fast, easy and reliable. It significantly reduces splicing time and effort by eliminating a fusion splice point. FRSC cables are available in standard and custom lengths in 2-12 terminations with various connector types such as SC/APC, SC/UPC, FC/APC, FC/UPC and LC/UPC. Fiber Receiver Service Cable with Armored Standard PE Jacket Features * Field proven, durable connecting hardware * Installed hard-line entry connector * High quality optical terminations meet all geometric and optical performance requirements * Gel-filled cable * Ordering flexibility; available in standard and custom lengths and connector counts * Mini-central core type cable * Individualized serial numbers * SC/UPC, FC/UPC, SC/APC, FC/APC, LC/UPC * Two to twelve fiber counts available Specifications PARAMETER VALUE Operating Temperature F (C) -40 to 158 (-40 to 70) Storage Temperature F (C) -58 to 158 (-50 to 70) Crush Resistance lbs. (kg) 1000 (453.5 kg) Impact Resistance 25 lbs. @ 2.2 lbs. per foot (11.25 kg @ 0.99 kg) Flexing 25 lbs. @ 5 in. (11.25 kg @ 12.7 kg) Fiber Core Diameter (microns) 8.3 Maximum Insertion Loss (dB) 0.25 (UPC), 0.35 (APC) UPC Return Loss (dB) -55 APC Return Loss (dB) -65 Outer Jacket Material Riser-rated PVC Finish Nickel-tin plated brass Cable Pullout Tensile Strength lbs. (kg) 247 (112.04) Entry Threads in. 0.625 x 24 Dimensions in. (cm) 4.25 long x 0.875 diameter (10.8 x 2.22) (c) 2002, AFL Telecommunications, all rights reserved. Revision 0, 10.05.05 Specifications are subject to change without notice. 13 LightLinkTM Fiber Receiver Service Cable (FRSC) Fiber Receiver Service Cable with Non-Armored All-Dielectric UniFlexTM Features * Polyurethane riser rated indoor/outdoor loose tube single-mode cable * Flexible bend radius of 19cm for installation and 10cm for operation * Polyurethane jacket reinforced with aramid yard for exceptional durability * Variety of single-mode connector styles (not available in multimode) * Easy installation * Cable cut and terminated to custom lengths * Design eliminates movement of cable components * Connector ends clearly labeled for quick identification * 900m or 2.4mm upjacketed colorcoded legs, 2.0mm LC * Available in fiber counts from 2-12 fibers * Ultra Polish available for all connector types * Breakout length 1 meter * Available in single-mode pigtails * Angle Polish available on FC and SC connectors * Pulling strength in excess of 150 lbs. * Anti-twist crimp Specifications COLOR FURCATION - FIBER NUMBER REFERENCE GROMMET SPECIFICATIONS - STANDARD D 1 Blue 4 Brown 7 Red 10 Violet Inner Diameter 0.375" 2 Orange 5 Slate 8 Black 11 Rose Active Pull Test 35 lbs. 3 Green 6 White 9 Yellow 12 Aqua Overall length 45mm Hex Nut Size 7/8" Length from Hex Nut to end of front body 6mm Material Aluminum Gold Anodized Ordering Information ASC XXX Connector End A Connector End B Single-mode ASC = Angle SC AFC = Angle FC USC = Ultra SC UFC = Ultra FC UST = Ultra ST ULC = Ultra LC Single-mode XXX = No connector NC 012 Q Cable Type Fiber Count Fiber Type NC = Uni-Flex AN = Armored PE 002 = 2 004 = 4 006 = 6 008 = 8 010 = 10 012 = 12 Q = Single-mode 0010 Cable Length (meters) XXXX (specify length) 0010 = 10 meters N Leg Diameter N = 900m End A F = Furcated End A (c) 2002, AFL Telecommunications, all rights reserved. Revision 0, 10.05.05 Specifications are subject to change without notice. 14 Advanced Fiber Assemblies Advanced Fiber Assembly (AFA) technology encompasses all specialty pigtails and optical interfaces used in active and passive devices. The AFA product family includes customized SM and PM assemblies, hermetic pigtails, capillary-based terminations, lensed fibers, and arrays. AFL Telecommunications' offers the industry's only One-Stop-Shop for metalized and non-metalized hermetic pigtails, complete with connectivity, lensed fibers, customized Kovar feedthoughts, AR coatings, and Fiber Bragg Gratings for wavelength stability. Ordering Information End A A F A - Fiber Type Jacket Type 3 4 - End B Connector A Alignment A 2 2 - End B Alignment B ARC B 0 0 0 - Metalization Kovar Ferrule Length 0 0 2 Fiber Type Alignment Alignment Metalization Jumper Length 1 = Single-mode 2 = PANDA(R) 1550 3 = PANDA(R) 980 4 = Multimode, 62.5 5 = Custom 0 = No Alignment 1 = Slow Axis 2 = Fast Axis 3 = Custom 0 = No Alignment 1 = Slow Axis 2 = Fast Axis 3 = Custom 0 = Metalization 1 = 10mm 2 = 13mm 3 = 17mm 4 = 20mm 5 = Custom 0 = Custom 1 = 1 meter 2 = 2 meters 3 = 3 meters 4 = 4 meters 5 = 5 meters Jacket Type 1 = 250m 2 = 400m 3 = 900m 4 = 900m Hytrel 5 = 3mm PVC 6 = Custom Connector A End B ARC B Kovar Ferrule (ODxL) 0 = No Connector 1 = FC/UPC 2 = FC/APC 3 = SC/UPC 4 = SC/APC 5 = LC/UPC 6 = Custom 0 = Bare Fiber 1 = Capillary (1.8mm x 6mm) 2 = Lensed Fiber (Wedge) 3 = Lensed Fiber (Conical) 4 = 0 Degree Polish 5 = 8 Degree Polish 6 = Custom 0 = No ARC 1 = 1550nm, < 0.3% 2 = Custom 0 = No Ferrule 1 = Ferrule A (2.5 x 10mm) 2 = Ferrule B (1.6 x 10mm) 3 = Ferrule C (0.9 x 6mm) 4 = Custom Assembly Length Connector End A Alignment End A Metalization Fiber Type Jacket Type Ferrule Type End B Alignment End B AR Coating (c) 2002, AFL Telecommunications, all rights reserved. Revision 0, 10.05.05 Specifications are subject to change without notice. 15 Lensed Fiber Technology Lensed fibers are rapidly becoming the method of choice for interfacing optical fiber to active devices and waveguides. Lensing technology provides highly efficient couplings while consuming a fraction of the space and costs of bulk optic alternatives. Symmetrical or "Conical" conical lens Cylindrical or "Wedge" AFL Telecommunications' proprietary laser shaping technology enables high-end lenses to be manufactured in volume at low costs. The laser quickly shapes the fiber tip into a precise geometry using an optimized numerical solution based on the targeted far-field profile. In-line far-field monitoring ensures repeatability and high coupling efficiency. This technology provides 10 times the throughput of conventional mechanical methods. Furthermore, the yield loss from laser shaping is less than one percent, compared to 10-20 percent for mechanical matching. These exceptional yields allow high-value fiber (i.e. FBGs, PM fiber, metalized fiber, etc.) to be lensed at minimal costs while maintaining process flow flexibility. AFL Telecommunications' Advanced Fiber Assembly platform allows OEMs to consolidate suppliers of metalized fiber, hermetic sleeves, AR coatings, Lensing, Fiber Bragg Gratings and connectorization into a single source for the entire pigtail assembly. Biconical Angled Cylindrical Features Lensed fiber technology offers advantages over traditional mechanical and fusion lensing methods; * Increased coupling efficiency - lensed fiber offers precise geometry and surface finish compared to mechanical/fusion methods * Increased performance - laser machining offers optimization around focal length, spot size and far-field parameters * Increased reliability - Far-field feedback loop eliminates rework and inspections * Increased reproducibility and flexibility - lensing provides optimized geometry created by numerical solution * Increased Value - high yields enable packaging of customized total solutions Angled Biconical Angled Cleave (c) 2002, AFL Telecommunications, all rights reserved. Revision 0, 4.01.05 Specifications are subject to change without notice. 16 Lensed Fiber Technology Conical Lens PARAMETER STANDARD GRADE* CUSTOM GRADE** Included angle (degrees) 80 - 110 50 - 80 Angle tolerance (degrees) + / -1 + / -1 Tip radius (microns) 5 - 20 3-5 PM axis tolerance (degrees) + /- 2 + / -2 Lens centration (microns) 1.0 0.5 *2 week lead time **4 to 6 week lead time Angled & Biconic Wedge PARAMETER STANDARD GRADE* CUSTOM GRADE** Included angle (degrees) 80 - 110 50 - 80 Angle tolerance (degrees) + / -1 + / -1 Tip radius (microns) 5 - 20 3-5 Lens asymmetry 2.5 - 4.5 1-5 PM axis tolerance (degrees) + /- 2 + / -2 Lens centration (microns) 1.0 0.5 *2 week lead time **4 to 6 week lead time Angled Endface Fiber Types PARAMETER VALUE SM, MM, PANDA(R), Tiger Angle (degrees) 0 - 60 Single Fiber and Ribbon Angle tolerance (degrees) + / -1 980nm, 1480nm, 14xxnm stabilization (FBG) PM axis tolerance (degrees) + / -2 Comparison of Various Lensing Methods PROCESS SPEED (LENSES/HR) PROCESS YIELD (RELATIVE %) CAPABILITY (LENS TYPE*) QUALITY (RELATIVE SCALE) FLEXIBILITY (CHANGE OVER TIME) 120 99% SLF, CLF, ACLF, BIC, ABIC, Cleave 10 10 s in-situ far-field, feedback $ Mechanical Polishing 3 70% SLF, CLF, ACLF, Cleave 10 1 hour off-line $$$ Reverse Fusion Splice 60 60% SLF 3 n/a Etch and Melt 10 60% SLF 4 n/a off-line $$$ Grind and Melt 6 50% SLF, CLF, Cleave 6 1 hour off-line $$ TECHNIQUE AFL Laser Shaping QA METHOD RELATIVE PRICING ($/UNIT) $$ * Lens type abbreviations: SLF Symmetrical Lensed Fiber (Conical lens) CLF Cylindrical Lensed ACLF Angled Cylindrical Lensed Fiber BIC Biconical Lensed Fiber (SLF followed by CLF) ABIC Angled Biconical Lensed Fiber (SLF followed by ACLF) (c) 2002, AFL Telecommunications, all rights reserved. Revision 0, 4.01.05 Specifications are subject to change without notice. 17 Hermetic Fiber Assemblies Hermetic Fiber Assemblies are designed to meet today's environmental sealing requirements for optical components used in military, telecommunication and sensing applications. The assembly is designed to integrate hermetic functionality (metalized and non-metalized), mechanical robustness, optical integrity and performance into a single package. Termination options include high-performance connectors, capillaries, lensed fibers and bare fiber endfaces. Features Applications * Metalized SM or Polarization Maintaining (PM) fibers * Kovar ferrule construction for thermal stability and device attachment ease * Hermetic seals greater than 10-8 cc/sec helium * Standard and custom designs available * Guaranteed polarization alignment throughout assembly for PM-based designs * Rugged construction designed to meet Telcordia and Military mechanical/ environmental requirements * * * * * * * Laser Packages (LDs, Source Lasers, etc.) Military Components DWDM Components Modulators Attenuators Sensors Fiber Optic Gyros Specifications METALIZATION PROPERTY SPECIFICATION AND LIMITS Coating Type Nickel/Gold Coating Thickness Gold Nickel 0.1 to 0.2 m 4.0 + 1 m Dimensional Tolerances Metalization Length Fiber Tip Length (non-metalized 125 m) Metalization/250 m Overcoat Length 3.0 to 40.0 + 1.0 mm 0.2 to 20.0 + 1.0 mm 0 to 5 mm Physical Properties Metal-Glass Adhesion Hermeticity Pull Strength (Kovar ferrule-to-fiber) Solder Compatibility Operating Temperature > 1Kg < 10-9 ATM cc/sec He > 1Kg SnPb, InAg, AuSn -40C to + 85C Fiber Types PANDA/PM, SM, MM (c) 2002, AFL Telecommunications, all rights reserved. Revision 0, 4.01.05 Specifications are subject to change without notice. 18 Polarization Maintaining (PM) Assemblies Advances in telecommunications and optical technology have led to a demand for polarization control in optical signal processing. AFL Telecommunications offers SC, FC and LC style jumpers with the optical polarization control of PANDA(R) fiber. Fujikura PANDA fiber is recognized worldwide as the industry standard for polarization maintaining applications. Specifications PARAMETER STANDARD (SC/FC/LC) UPC APC UPC APC IL (dB) <0.5 <0.5 <0.3 <0.3 Features RL (dB) * * * * Polarization Axis Alignment Accuracy High extinction ratio Low insertion loss Custom polarization orientation Custom designs available >50 >60 >55 >65 ( + ) 3 ( + ) 3 ( + ) 3 ( + ) 3 >25 >25 >27 >27 Extinction Ratio Fiber Type Fujikura PANDA(R) Fiber Length (including connectors1) 0 to 5.0m Operating Temperature using UV/UV-250 or UV/UV-400 using UV/NY-900 -20 to +70C +5 to +45C -40 to +70C Storage Temperature Applications * * * * * PREMIUM (SC/FC/LC) Polish FC Key Width (External) Polarization based modulators Fiber Optic Gyros High bit rate telecommunications Interferometry Optical amplifiers narrow key 1.97-2.02mm 1. Please specify the length upon ordering 2. LC not available in APC NOTE: Unless otherwise stated, the specifications listed were measured at ambient temperature (25 5C) Cross Section of PANDA(R) Fiber Relative to Connector Key Ordering Information P M J - 3 2 Connector A Connector A Alignment 0 = No Connector 1 = FC/UPC 2 = FC/APC 3 = SC/UPC 4 = SC/APC 5 = LC/UPC 5 0 0 = No Alignment 1 = Slow Axis 2 = Fast Axis 3 = Custom Jumper Length 3 2 Connector B Connector B Alignment 0 = No Connector 1 = FC/UPC 2 = FC/APC 3 = SC/UPC 4 = SC/APC 5 = LC/UPC 00 = Custom 01 = 1 meter 02 = 2 meters 03 = 3 meters 04 = 4 meters 05 = 5 meters 0 = No Alignment 1 = Slow Axis 2 = Fast Axis 3 = Custom 1 3 Fiber Type Jacket Type 1 = PANDA(R) 1550 2 = PANDA(R) 980 3 = Custom 1 = 250m 2 = 400m 3 = 900m 4 = 900m Hytrel 5 = 3mm PVC 6 = Custom *** Max. Length is 5 meters + Please call AFL for detailed information on customized specifications and other fiber types (c) 2002, AFL Telecommunications, all rights reserved. Revision 0, 4.01.05 Specifications are subject to change without notice. 19 Field MasterTM LC, SC, & ST Connectors The Field MasterTM Connectors for field termination of fiber optics feature high precision, high reliability and low applied connector cost. Durable metal components, industry-standard connector designs, and proven crimp technology gives the customer peace-of-mind that their installed network is steady and reliable. Field MasterTM Tool Kits come complete with all necessary tools and consumables for the professional installation of AFL's Field MasterTM Connectors. Features * * * * * High precision ceramic ferrules insure fiber alignment and repeatable performance. Rugged metal connector bodies provide sturdy cable terminations. Industry standard interfaces allow interoperability with media equipment. Meets EIA/TIA 568A performance requirements. Field proven crimp technology improves connector/cable tensile performance. Ordering Information Applications CONNECTOR DESCRIPTION PART NO. * * * * * * SC mm FM connector 900m CS000308* SC mm FM connector 3.0mm CS000309* SC sm FM connector 900m CS000310* SC sm FM connector 3.0mm CS000311* ST mm FM connector 900m CS000316* ST mm FM connector 3.0mm CS000317* ST sm FM connector 900m CS000318* ST sm FM connector 3.0mm CS000319* LC mm FM connector 900m CS000320* LC mm FM connector 2.0mm CS000321* LC sm FM connector 900m CS000322* LC sm FM connector 2.0mm CS000323* Premise environments Desk for LAN environments Patch panels Direct equipment termination Fiber to the Subscriber (FTTx) applications Repair / replacement requirements * Packaged 100 pieces per box. Field MasterTM Tool Kit Field MasterTM kits come complete with all necessary tools and consumables to professionally install Field MasterTM connectors. * Quick, Compact and easy to use * Complete instructions included * For use with ST, SC and LC Field MasterTM Connectors Ordering Information Field MasterTM Tool Kit DESCRIPTION PART NO. Field MasterTM Tool Kit - no crimp tool FM000065 Crimp Tool with die set CS000337 (c) 2002, AFL Telecommunications, all rights reserved. Revision 0, 10.05.05 Specifications are subject to change without notice. 20 FAST-SC & FAST-ST Connectors AFL's new FAST Connectors are pre-polished, field installable connectors that eliminate the need for hand polishing in the field. FAST Connectors provide an immediate termination to either single-mode or multimode fibers. FAST Connectors feature a pre-stubbed factory-polished ferrule that couples to the fiber being terminated by precision mechanical alignment and insures low loss with a proprietary gel. Each FAST Connector comes with a factory-installed wedge clip that holds the clamping device open while the fiber is inserted. Once the fiber is in place, the wedge clip is removed and discarded. Operation PUSH HERE TO DISENGAGE WEDGE / LOCK FIBER Features * * * * * Easy assembly process Fiber can be reseated No expensive tools required No epoxy required Factory polishing eliminates loss concerns * Meets TIA/EIA 568A performance requirements Applications * Premise environments * Connections at the desk for LAN environments * Patch panels * Direct equipment termination * Fiber to the Subscriber (FTTx) applications * Repair/replacement requirements Index Match Gel PUSH HERE TO ENGAGE WEDGE Optical Fiber Connector Body PUSH HERE TO DISENGAGE WEDGE / LOCK FIBER Specifications PARAMETER VALUE Insertion Loss: Single-mode 50/125 62.5/125 Average: 0.2 dB, Maximum: 0.5 dB Average: 0.1 dB, Maximum: 0.5 dB Average: 0.1 dB, Maximum: 0.5 dB Return Loss (Single-mode) Average: 56.4 dB, Maximum: 45 dB Operating Temperature -40C to +75C Ordering Information FAST-SC CONNECTOR PART NUMBER FIBER TYPE HOUSING COLOR CABLE SIZE CS000825 Multimode 50/125 Black 250 or 900 um CS000826 Multimode 62.5/125 Beige 250 or 900 um CS000827 Single-mode Blue 250 or 900 um FIBER TYPE HOUSING COLOR CABLE SIZE CS000828 Multimode 50/125 Black 250 or 900 um CS000829 Multimode 62.5/125 Beige 250 or 900 um CS000830 Single-mode Blue 250 or 900 um FAST-ST CONNECOR PART NUMBER (c) 2005, AFL Telecommunications, all rights reserved. Revision 0, 10.05.05 Specifications are subject to change without notice. 21 Plastic Optical Fiber Data Link System The AFL Optical Data Link combines the benefits of fiber optic signaling with the convenience of plug-in PCB electrical termination. It is designed to permit fast, reliable, self-termination of single channel plastic optical fiber without the needs of special tools, adhesives or polishing. Features Applications * * * * * Industrial Controls Automation remote sensing Audio visual links Automotive networking Office communication equipment * * * * * * Terminates plastic fiber optic cable in seconds without tools, adhesives or polishing Compatible with 1000m diameter simplex fiber with an OD of 2.25mm or 5mm Polarized plug provides positive, snap retention with a quick-release latch Suitable for terminating data transmission links at data rates of 3Mb/s Opto-electrical interface includes a TTL compatible receiver and LED driver Color coded housings enable easy identification of transmit or receiver ends Ordering Information PART NUMBER DESCRIPTION 92915-T-DD Transmitter (red) 3 Mb/s 92915-T-AB Transmitter (red) 3 Mb/s 92915-R-HS-4 Receiver (black) 3 Mb/s 92910 Plug (black) 2.25mm POF 92910-R Plug (red) 2.25mm POF 92910-C5 Plug (black) 5mm POF 92910-R-C5 Plug (red) 5mm POF 93902-100 100 ft reel Simplex cable, 2.2mm 93902-500 500 ft reel Simplex cable, 2.2mm 93802-100 100 ft reel Duplex cable,2.2mm zip 93802-500 500 ft reel Duplex cable, 2.2mm zip 93903-100-AB 100 ft reel Ruggedized Simplex cable, 5mm 93903-500-AB 500 ft reel Ruggedized Simplex cable, 5mm (c) 2002, AFL Telecommunications, all rights reserved. Revision 0, 4.01.05 Specifications are subject to change without notice. 22 Precision Connectors Custom drilled hole sizes are produced very precisely in the metal ferrules of industry standard connectors such as the ST, FC and SMA. A range of sizes from 140 micron to 1235 microns are typical, but customer specific sizes are possible. Stainless steel or steel alloy (Arcap) are available depending on the customer's requirement. Features * * * * * * Precision hole diameter and position Stainless steel or steel alloy ferrules Ruggedized connector construction Industry standard SMA, ST, or FC interfaces Applicable to large core glass or plastic fibers Custom sizes available Applications * * * * * Industrial controls Medical sensing Aerospace/military Data processing networks Optical security systems Ordering Information CONNECTOR STYLE PART NUMBER SERIES SMA Connector 698-DSC-XXXX ST Connector 68290-XXXX FC Connector 69301-XXXX (c) 2002, AFL Telecommunications, all rights reserved. Revision 0, 4.01.05 Specifications are subject to change without notice. 23 SC Adapters SC adapters are used to mate industry standard SC connectors. Adapters are available with metal and ceramic alignment sleeves, and are color coded for easy identification. The duplex adapters accept two simplex connectors or one duplex connection. Hybrids are available for special applications. SC SIMPLEX ADAPTERS TYPE SC Simplex Adapters SC Duplex Adapters MODE DESCRIPTION SLEEVE COLOR PART NUMBER SC Simplex MM SC-A Type Ceramic Beige C209560 SC Simplex MM SC-A Type Metallic Beige C209563 SC Simplex SM SC-A Type Ceramic Blue C028851 SC Simplex SM Short Flange Ceramic Blue C058475 SC Simplex SM SC-A Type Ceramic Plated C002766 SC Simplex SM SC-A Type Metallic Blue C033235 SC Simplex SM Short Flange Metallic Blue C057037 SC Simplex SM SC-A Type Metallic Plated C002507 SC Simplex SM / AP SC-A Type Ceramic Green C080810 SC Simplex SM / AP Short Flange Ceramic Green C147880 SC DUPLEX ADAPTERS TYPE MODE DESCRIPTION SLEEVE COLOR PART NUMBER SC Duplex MM Long Flange Metallic Beige C209383 SC Duplex MM Long Flange Ceramic Beige C209081 SC Duplex SM No Clip / Screw Mount Ceramic Blue C094862 SC Duplex SM Long Flange Ceramic Blue C092258 SC Duplex SM No Clip / Screw Mount Metallic Blue C096261 SC Duplex SM Long Flange Metallic Blue C092266 SC Shuttered Adapters The SC Shuttered Adapters are a safety feature used to prevent potentially harmful exposure to the eye when the connector is not installed or is disengaged. A spring-loaded door automatically covers the adapter when the connector is not installed as safety protection. SC STYLE ADAPTERS TYPE MODE DESCRIPTION INSERT COLOR PART NUMBER SC Simplex SM with Shutter Assembly Metallic Blue C097268 SC Simplex SM with Shutter Assembly Ceramic Blue C096210 SC Simplex SM / AP with Shutter Assembly Ceramic Green C116004 SC Simplex Shutter Only N/A N/A N/A C087734 (c) 2002, AFL Telecommunications, all rights reserved. Revision 0, 4.01.05 Specifications are subject to change without notice. 24 LC Adapters LC style adapters are used in high density applications and feature a quick plug in installation. Adapters are available in both simplex and duplex designs and utilize high quality zirconia and phosphorous bronze sleeves. The LC duplex adapter uses the same cutout as the copper RJ-45, resulting in less redesign work when retrofitting existing panels. TYPE MODE INSERT COLOR PART NUMBER LC Duplex SM Ceramic Blue C178298 LC Duplex MM Metallic Beige C203956 LC Simplex SM Ceramic Blue C186363 LC Simplex MM Metallic Beige C209176 MTP(R) Adapters The MTP adapter connects two industry standard MTP connectors. The compact MTP adapter measures 25mm x 10mm and is found in high density applications. TYPE MODE DESCRIPTION INSERT COLOR PART NUMBER MTP SM/MM Flange Mount -- Black C057010 Hybrid Adapters Hybrid FC, SC and ST adapters are available to fit specific application needs. TYPE MODE DESCRIPTION INSERT COLOR PART NUMBER FC - SC Simplex SM / AP Angled Adapter Ceramic Stainless Steel C130082 FC - SC Simplex SM Square Mount Metallic Stainless Steel C004127 FC - ST Simplex SM Square Mount Metallic Stainless Steel C002401 FC - ST Simplex SM Square Mount Ceramic Stainless Steel C032980 SC - FC Simplex SM Flat Mount Metallic Stainless Steel C033022 SC - FC Simplex SM Square Mount Ceramic Stainless Steel C002453 SC - FC Simplex SM Flat Mount Ceramic Stainless Steel C033030 SC - ST Simplex SM Flat Mount Metallic Blue C002499 SC - ST Simplex SM Square Mount Metallic Stainless Steel C004133 SC - ST Simplex SM Flat Mount Ceramic Blue C024392 SC - ST Simplex SM Square Mount Ceramic Stainless Steel C038733 (c) 2002, AFL Telecommunications, all rights reserved. Revision 0, 4.01.05 Specifications are subject to change without notice. 25 FC Adapters FC adapters connect industry standard FC connectors and are available in Square-Mount, D-Mount and Flange-Mount versions. Our FC adapters feature a metal body for long life and are available with either ceramic or metallic sleeves. The FC D-Mount adapter easily installs into panel mount applications and conforms to JIS C5970. FC Square-Mount meets Bellcore GA326 and the angle polish versions meet the industry standard 2.0mm key width. An assortment of hybrid configurations is available. TYPE MODE DESCRIPTION INSERT COLOR PART NUMBER FC Simplex SM / AP Square Mount Ceramic Metal C143346 FC Simplex SM Square Mount Ceramic Metal C146558 FC Simplex SM D Mount Metallic Metal C143680 FC Simplex SM / AP D Mount Ceramic Metal C146566 FC Simplex SM D Mount Ceramic Metal C145357 FC Simplex SM Square Mount Die Cast Metallic Metal C066443 ST Adapters ST adapters connect industry standard ST connectors and are available in D-Mount and Flange-Mount versions. ST adapters are available with ceramic or metallic sleeves, feature a metal body for long life, and easily install in panel mount applications. TYPE MODE DESCRIPTION INSERT COLOR PART NUMBER ST Simplex SM Only D Mount Ceramic Metal C094994 ST Simplex MM Only D Mount Metallic Metal C096377 MT-RJ Adapters MT-RJ adapters connect industry standard MT-RJ connectors in high-density applications. MT-RJ adapters are keyed for proper alignment and conform to RJ-45 modular plates. Mounting hardware is not included. TYPE MT-RJ Duplex MODE DESCRIPTION INSERT COLOR PART NUMBER MM Flange Mount -- Beige C196855 (c) 2002, AFL Telecommunications, all rights reserved. Revision 0, 4.01.05 Specifications are subject to change without notice. 26 Buildout-Style Attenuators Buildout-style attenuators provide superior performance for all single-mode in line attenuation requirements. Standard attenuation values are 3, 5, 10, 15 and 20dB. Buildout attenuators are available in SC, ST, LC, and FC connector styles. They use no air gap, filters or light path discontinuities. Attenuation is achieved by controlled absorption of light energy. This results in a polarization insensitive device with high power handling capability, environmentally stable and exceptionally responsive across a wide bandpass range. Features * Long-term reliability * Excellent environmental stability * Low ripple, wavelength independent attenuation * Certified to more than 125mw continuous power handling capability with no degradation in performance * Polarization insensitive * TelcordiaTM approved Application * Broadband Network * Video Distribution * Long Haul Telecommunications (CLEC, CAPS) * Local Area Networks (LAN) * Network Testing * Passive Optical Networks * Telco * Fiber in the Loop Specifications PARAMETER Standard Attenuation Values Attenuation Tolerance Operating Temperature Range: Vibration resistance Back Reflection Operating Wavelength: VALUE 5, 10, 15 and 20dB Standard at 10% -40 to +75C <0.1X attenuation value -55dB in Ultra Polish (UPC); -60dB in Angle Polish (APC) 1310 & 1550nm +/-25nm Ordering Information ULTRA FC SINGLE-MODE BOAS (MALE TO FEMALE) CONFIG. FC / UP FC / UP FC / UP FC / UP FC / UP FC / UP FC / UP FC / UP FC / UP FC / UP FC / UP FC / UP FC / UP FC / UP FC / UP FC / UP PART NO. VALUE (DB) BACK REFL. C201004 1 > 55dB C201010 2 > 55dB C201013 3 > 55dB C201017 4 > 55dB C201022 5 > 55dB C203303 6 > 55dB C203308 7 > 55dB C203314 8 > 55dB C203317 9 > 55dB C201028 10 > 55dB C203321 11 > 55dB C203326 12 > 55dB C201031 15 > 55dB C201035 20 > 55dB C203332 25 > 55dB C203335 30 > 55dB ANGLE FC SINGLE-MODE BOAS (MALE TO FEMALE) CONFIG. FC / AP FC / AP FC / AP FC / AP PART NO. VALUE (DB) BACK REFL. C197878 5 > 60dB C197881 10 > 60dB C197885 15 > 60dB C197890 20 > 60dB ULTRA ST SINGLE-MODE BOAS CONFIG. ST / UP ST / UP ST / UP ST / UP ULTRA SC SINGLE-MODE BOAS (MALE TO FEMALE) CONFIG. SC / UP SC / UP SC / UP SC / UP SC / UP SC / UP SC / UP SC / UP SC / UP SC / UP SC / UP SC / UP SC / UP SC / UP SC / UP SC / UP PART NO. VALUE (DB) BACK REFL. C200938 1 > 55dB C200941 2 > 55dB C200945 3 > 55dB C200950 4 > 55dB C200956 5 > 55dB C200959 6 > 55dB C201946 7 > 55dB C200963 8 > 55dB C201949 9 > 55dB C200968 10 > 55dB C201953 11 > 55dB C201958 12 > 55dB C200974 15 > 55dB C200977 20 > 55dB C200981 25 > 55dB C200986 30 > 55dB ANGLE SC SINGLE-MODE BOAS (MALE TO FEMALE) CONFIG. SC / AP SC / AP SC / AP SC / AP PART NO. VALUE (DB) BACK REFL. C197899 5 > 60dB C197903 10 > 60dB C197908 15 > 60dB C197914 20 > 60dB ULTRA LC SINGLE-MODE BOAS PART NO. VALUE (DB) BACK REFL. C222113 5 > 55dB C222118 10 > 55dB C222124 15 > 55dB C222127 20 > 55dB CONFIG. LC / UP LC / UP LC / UP LC / UP PART NO. VALUE (DB) BACK REFL. CS000091 5 > 55dB CS000092 10 > 55dB CS000093 15 > 55dB CS000094 20 > 55dB NOTE: Attenuators are available in 1dB increments. Contact customer service for ordering information. (c) 2002, AFL Telecommunications, all rights reserved. Revision 0, 4.01.05 Specifications are subject to change without notice. 27 SC and FC Optical Terminators SC and FC optical terminators are used to terminate unused connector ports in fiber optic systems so that unwanted reflections are not introduced back into the system. All AFL optical terminators feature zirconia ferrules for long life and durability. Specifications PARAMETER VALUE Reflectance <-55dB (ultra polish) Reflectance <-60dB (angle polish) Operating Temperature -40C to +85C Operating Wavelength 1260nm to 1580nm Ordering Information DESCRIPTION ITEM NUMBER FC/UP Terminator C067407 SC/UP Terminator C067393 FC/AP Terminator C082562 SC/AP Terminator C148828 LC/UP Terminator CS000637 LC/AP Terminator CS000638 ST/UP Terminator C167083 Loopback Connector This standard fiber channel design is used in testing transceiver systems. The loopback is rugged and compact to withstand multiple uses and features a flexible length for any testing requirements. Ordering Information ITEM CABLE ITEM NUMBER SC Loopback, SM 250m, 2 meters C185774 SC Loopback, MM, 50/125 250m, 2 meters C159013 SC Loopback, MM, 62.5/125 250m, 2 meters C178670 (c) 2002, AFL Telecommunications, all rights reserved. Revision 0, 4.01.05 Specifications are subject to change without notice. 28 Field MasterTM Tool Kit Field MasterTM kits come complete with all necessary tools and consumables to professionally install Field MasterTM connectors. ITEM DESCRIPTION PART NUMBER Field MasterTM Tool Kit FM000065 Kit Includes (consumables): Features * * * * Quick and easy to use Compact Complete instructions included For use with ST, SC, and LC Field MasterTM Connectors Cable Prep Template Yellow polish film, 3.0m (10 per pack) Pink polish film, 1.0m (10 per pack) Pink diamond film, 3.0m Rubber polishing pad (5") Sharpie(R) permanent marker Jacket stripper Buffer stripper Kevlar cutter Scribe tool Polishing puck - SC, ST Polishing puck - LC Cletop stick cleaner Fiber prepartion fluid Applicator tips for adhesive Water bottle (1 oz.) Field installable adhesive w/MSDS (1.75 oz.) Field installable primer w/MSDS (1.75 oz.) Cloth wipes FM000426 C006907-10 C006913-10 C078700 C015407 C015830 C015687 C015296 C095257 C182635 CS000446 CS000338 C008812 FPF1-00 C006037 C015849 C180691 C181310 FM000413 Crimp Tool ITEM DESCRIPTION PART NUMBER Crimp Tool with Die Set (Crimp diameters: .151" hex, .178" hex, .213" hex) CS000337 (c) 2002, AFL Telecommunications, all rights reserved. Revision 0, 10.05.05 Specifications are subject to change without notice. 29 Loose Tube Fanout Kits Loose tube fanout kits route 250m fiber into 900m tubes ready for connectorization. Easily installed in minutes, these kits require no special tools. Color coded tubing assists with easy identification. The furcation unit snaps together eliminating epoxy. Loose tube fanout kits are available in 6 and 12 fiber configurations. Ordering Information CABLE TYPE FIBER COUNT LENGTH PART NUMBER Loose Tube Fanout Kit (3.0mm tube) 6 Fiber 24 inches C189826 Loose Tube Fanout Kit (3.0mm tube) 12 Fiber 24 inches C189818 Ribbon-Link(R) Fanout Kit 6 Fiber 36 inches C189842 Ribbon-Link Fanout Kit 12 Fiber 36 inches C189834 Uni-Tube Fanout Kit 6 Fiber 36 inches C193114 Uni-Tube Fanout Kit 12 Fiber 36 inches C193122 (R) (c) 2002, AFL Telecommunications, all rights reserved. Revision 0, 4.01.05 Specifications are subject to change without notice. 30 Adapter Cleaners For economical and fast removal of dirt, dust, oil and grease from adapters, choose AFL Telecommunication's convenient adapter cleaners. Designed to thoroughly clean hard to reach areas and adapters, they require no alcohol or solvents and their small size makes them ideal for field applications. MODEL NUMBER DESCRIPTION PART NUMBER ACT-01 Adapter Cleaner Tips for SC, ST, FC (5 pack) C008812 ACT-02 Adapter Cleaner Tips for MU and LC (5 pack) C194404 Cletop Ferrule Cleaner The Cletop Automatic Ferrule Connector Cleaner quickly and effectively cleans fiber optic connectors without the need for alcohol or solvent wipes. The dry woven cloth effectively removes dirt, dust, oil, grease and debris from connector and end face. The Cletop-A is designed to clean SC, ST and FC connector types, while the Cletop-S has an open cleaning slot more suitable for LC, MTP and MT-RJ connectors. Cletop-A MODEL NUMBER DESCRIPTION PART NUMBER Cletop-A Cleaner for SC, ST and FC connectors C036692 Refill for Cletop-A C036684 Cleaner for LC, MTP and MT-RJ connectors CS000135 Refill for Cletop-S CS000136 Cletop-S Features * Compact and light weight * Ideal for assembly lines and in the field * 400 swipes each reel * Replacement reels are available (400 swipes per reel) Cletop-S (c) 2002, AFL Telecommunications, all rights reserved. Revision 0, 4.01.05 Specifications are subject to change without notice. 31 Connector/Adapter Cleaning Kit The Connector/Adapter Cleaning Kit is a complete kit solution for maintaining the optical integrity of passive network components such as connectors, jumpers, couplers, patch panels, etc. The Connector/Adapter Cleaning Kit includes all the cleaning supplies you need to maintain clean ferrules and connectors in an organized, portable and rugged carrying case. Kit Includes * * * * * * * Rugged carrying case for complete protection and organization of supplies FCC-02R Prep Cleaner (1) FCC-R Replacement cartridge (400 wipes) ACT-01 Adapter Cleaner Tips (20) Alcohol dispenser (1) Lint free Kim Wipes Carry case Ordering Information DESCRIPTION PART NUMBER Connector/Adapter Cleaning Kit C182120 MPO Cleaner (MPO-CLK-A) The MPO Cleaner is a high-performance device designed for cleaning the ferrule endfaces of MPO (MTP(R)) connectors. This tool cleans the fiber endface without the use of alcohol. It also effectively cleans all 12 fibers at once. Features * * * * Intermateability with FOCIS-5 (MPO) Capable of cleaning MPO/MTP ferrules inside or outside a MPO/MTP adapter Capable of cleaning ferrules with or without guide pins 500 Cleanings Ordering Information MODEL DESCRIPTION PART NUMBER MPO-CLK-A Cleaner for MPO and MTP connectors CS000710 (c) 2002, AFL Telecommunications, all rights reserved. Revision 0, 4.01.05 Specifications are subject to change without notice. 32 Planar Couplers The Planar Coupler provides the uniform division of an optical signal by having one input port and multiple output ports. Compact packaging and stable optical parameters allow these couplers to be integrated into Telecommunications, Local Area Network (LAN), and Cable Television (CATV) networks. Specifications PARAMETER VALUE PART NUMBER CM000034 Features Operating Wavelength (Grade) * * * * * * * * Optical Split Ratio Low insertion loss Compact design Stable optical performance Dual Window (1310 & 1550nm) Low insertion loss Low back reflection High output uniformity Telecordia GR-1029 and GR-1221 qualified C198299 TBA 1260-1360nm and 1480-1580nm (Standard) 1x4 1x8 1 x 16 1 x 32 Maximum Insertion Loss (dB) 7.5 11.0 14.2 17.8 Typical Insertion Loss (dB) 7.3 10.8 13.9 17.5 Maximum Uniformity (dB) 1.0 1.0 1.5 2.0 Typical Uniformity (dB) 0.8 0.8 1.3 1.8 PDL (dB) <0.3 <0.3 <0.4 <0.4 Return Loss (dB) >55 >55 >55 >55 Directivity (dB) >55 >55 >55 >55 Fiber Type SMF28e 250m equivalent Input/Output Fiber Length Applications Operating Temperature * * * * Package Dimensions (LxWxH) (mm) Telecommunications Networks Datacom LAN & CATV Networks FTTH, FTTB, & FTTC CM000033 1 meter 1.5 meters 1.5 meters 1.5 meters -40 to +85C 40 x 4 x 4 40 x 4 x 4 40 x 4 x 4 50 x 6.5 x 4 (c) 2005, AFL Telecommunications, all rights reserved. Revision 0, 10.06.05 Specifications are subject to change without notice. 33 Wideband Couplers The dual window Wideband Couplers (WBC) split or couple optical power in two wavelength regions while maintaining a very broad operating bandwidth. Split and coupling ratios are available from 5% to 50%. WBCs are widely considered one of the most costeffective solutions to optical power management. The WBC is an all-fiber device, based on AFL Telecommunications' fused biconic technology, and is designed and manufactured to meet Military and Telcordia requirements. Specifications Features * Dual window wideband operation * Low insertion loss over entire bandwidth and temperature (typical IL change <0.1dB) * Ultra-low PDL and temperature sensitivity * High directivity * Compact design * Environmentally stable, over 10 years of proven field reliability * Standard operating temperature range -4O C to +85 C * Fully tested to Telcordia 1209 and 1221 criteria Applications * * * * Telecommunications CATV LAN Monitoring of Networks STANDARD AND PREMIUM GRADES PARAMETER Operating Wavelength Return Loss Directivity Package Dimension Operating Temperature Storage Temperature VALUE 1310 nm + 50 and 1550 nm + 50 55 dB 55 dB 3.2 mm(dia.) x 55 mm(L) -40 to +85C -40 to +85C Ordering Information SINGLE-MODE STANDARD GRADE SPECIFICATIONS (MAX. INSERTION LOSS AND MAX. PDL) SPECIFICATIONS (DB) PRIMARY/SECONDARY PORT PDL (DB) 3.7/3.7 0.17 3.3/4.2 0.17 2.5/5.6 0.15 2.3/5.8 0.15 2.1/6.2 0.13 1.9/6.5 0.13 1.8/7.2 0.13 1.5/8.2 0.10 1.4/10.0 0.10 1.0/12.0 0.10 0.7/16.0 0.10 RATIO 50/50 55/45 60/40 65/35 67/33 70/30 75/25 80/20 85/15 90/10 95/5 PART NUMBER C198364 C198358 C198353 C198349 C198904 C198346 C198340 C198335 C198331 C198328 C198322 SINGLE-MODE PREMIUM GRADE SPECIFICATIONS (MAX. INSERTION LOSS AND MAX. PDL) SPECIFICATIONS (DB) PRIMARY/SECONDARY PORT PDL (DB) 3.6/3.6 0.15 3.2/4.1 0.15 2.7/4.7 0.14 2.3/5.3 0.14 2.2/5.7 0.14 2.0/6.0 0.13 1.8/6.8 0.13 1.3/7.8 0.10 1.0/9.2 0.10 0.8/11.2 0.10 0.5/14.4 0.10 RATIO 50/50 55/45 60/40 65/35 67/33 70/30 75/25 80/20 85/15 90/10 95/5 PART NUMBER C198364-P C198358-P C198353-P C198349-P C198904-P C198346-P C198340-P C198335-P C198331-P C198328-P C198322-P (c) 2002, AFL Telecommunications, all rights reserved. Revision 0, 10.05.05 Specifications are subject to change without notice. 34 Wavelength Division Multiplexer Couplers The WDM separates or combines wavelengths in the 1310 and 1550nm bands over an ultra-wide bandwidth (+ 20nm) and temperature range while maintaining excellent stability and optical performance. The device, which is fabricated using an advanced fused biconical taper technology, is designed to meet Telcordia 1209 and 1221 requirements. Specifications (Single-Mode Premium) Features * * * * * * Low insertion loss Ultra-wide bandwidth Wide operating temperature Low PDL Highly stable and reliable Epoxy-free optical path PARAMETER Model Number VALUE S004794 Configuration 1x2 Wavelength 1310 / 1550nm Directivity <-65dB Operating Temperature -40 to +85C Typical Temperature Stability <0.1dB Typical Polarization Stability (passband) <0.1dB Isolation 20dB *Isolation of 32dB and higher not available in 63mm L or 69mm L x 3mm OD Applications * * * * * * Telecommunications CATV Fiber Optic Sensors and Instruments Subscriber Loops Military Systems, Fiber Optic Gyros FTTH (c) 2002, AFL Telecommunications, all rights reserved. Revision 0, 4.01.05 Specifications are subject to change without notice. 35 Optical FTTP Coupler Module AFL Telecommunications' Optical FTTP Coupler Module is designed to satisfy requirements utilizing 1550nm bandwidths in FTTP applications and is specified for FTTP video installations. The module features a compact footprint with adapter ports consisting of SC/APC adapter outputs. Specifications PARAMETER Performance VALUE Wavelength 1540-1560 nm Insertion Loss 1550 < 3.9 dB PDL <0.2 dB PMD < 0.05 ps Return Loss > 55 dB Directivity > 55 dB Operating Temperature -40 to +75 C Storage Temperature -40 to +85 C Relative Humidity 0 to 90% Optical Power 500 mW Packaging Packaging Size Standard Single Width LGX(R) Rack Module Fiber Type Low-Water-Peak Non-Dispersion Shifted SMF-28e Connector Type All ports - SC/APC, Green WDM_FTTP_Module.eps Ordering Information PART NUMBER DESCRIPTION CM000072 Optical FTTP Coupler Module Dimensions 29.00mm 1.14" 171.00mm 6.73" 84.60mm 3.33" 155.60mm 6.13" LGX is a registered trademark of Furukawa Electric North America, Inc. (c) 2004, AFL Telecommunications, all rights reserved. Revision 0, 4.01.05 Specifications are subject to change without notice. 36 Optical FTTP WDM Module The Optical FTTP WDM Module is designed to satisfy requirements utilizing 1310, 1490 and 1550nm bandwidths in FTTP applications. The module features a compact footprint with adapter ports consisting of SC (UPC or APC) outputs. Specifications PARAMETER VALUE 1550 Band - Port 1 (Pass) 1550-1560 nm 1310 + 1490 Band - Port 2 (Reflect) 1260-1360 & 1480-1500 nm Insertion Loss 1550 < 1.2 dB 1310 + 1490 < 1.2 dB Isolation 1550 > 25 dB 1310 + 1490 > 20 dB PDL <0.2 dB PMD < 0.2 ps Return Loss > 50 dB Directivity > 50 dB Operating Temperature -40 to +75 C Storage Temperature -40 to +85 C Relative Humidity 0 to 90% Optical Power 500 mW PACKAGING Packaging Size Standard Single Width LGX(R) Rack Module Fiber Type Low-Water-Peak Non-Dispersion Shifted SMF-28e Port 3 (Common) - SC/APC WDM_FTTP_Module.eps Port 1 (Data) - SC/UPC Port 2 (Video) - SC/APC Connector Type Ordering Information PART NUMBER DESCRIPTION CM000043 Optical FTTP WDM Module Dimensions 29.00mm 1.14" 171.00mm 6.73" 84.60mm 3.33" 155.60mm 6.13" LGX is a registered trademark of Furukawa Electric North America, Inc. (c) 2004, AFL Telecommunications, all rights reserved. Revision 0, 10.05.05 Specifications are subject to change without notice. 37 CWDM (Coarse WDM) Module AFL Telecommunications introduces four and eight channel Coarse WDM Modules (CWDM) in a cost effective, mechanically rugged LGX(R) footprint or tray mounted module. The CWDM Modules are available with an assortment of industry standard connector interfaces to meet varying system requirements. Based on proven thin film technology, 20nm channel spacing allows for repeatable channel isolation. Rugged cases and sealed modules allow for increased thermal stability and long-term service life performance. Features Applications * * * * * * * * * * * Telcordia Qualified Components 20mm Channel Spacing Four or Eight Channel Separation Most Industry Standard Connectors Low Insertion Loss High Isolation CATV Systems Sensor Systems 10G Ethernet Systems Metro Optical Networks Metro Access Networks Specifications PARAMETER MINIMUM Center Wavelength (nm) 4 CHANNEL 8 CHANNEL TYPICAL MAXIMUM MINIMUM TYPICAL MAXIMUM 1471, 1491, 1511, 1531 1551, 1571, 1591, 1611 1511, 1531, 1551, 1571 Pass Channel Insertion Loss Passband Bandwidth -- 1.6dB 2.0 dB -- 2.5dB 12nm 14nm -- 12nm 14nm -- -- 0.3dB 0.5dB -- 0.3dB 0.5dB Passband Flatness 3.0dB Adjacent Channel Isolation 30dB 40dB -- 30dB 40dB -- Non-adjacent Channel Isolation 40dB 50dB -- 40dB 50dB -- Return Loss 50dB -- -- 50dB -- -- Directivity 50dB -- -- 50dB -- -- Pdl -- -- 0.1dB -- -- 0.1dB Pmd -- -- 0.1 ps -- -- 0.1 ps Operating Temperature Storage Temperature -5C to +65C -5C to +65C -40C to + 85C -40C to + 85C Ordering Information CWDM -- 00 -- 08 -- 02 -- USC Mux / Demux Channel Count Package Type Connector Interface 00 = Mux / Demux Pair 01 = Mux 02 = Demux 04 = 4 Channel 08 = 8 Channel 01 = Tray Module 02 = LGX(R) Rack Module USC = SC ASC = SC ULC = LC ALC = LC UFC = FC AFC = FC UPC APC UPC APC UPC APC LGX is a registered trademark of Furukawa Electric North America, Inc. (c) 2005, AFL Telecommunications, all rights reserved. Revision 0, 10.05.05 Specifications are subject to change without notice. 38 Optical Coupler Modules The Optical Coupler Module offers management of optical power and wavelength. The modules are comprised of Telcordia-compliant PLC or concatenated fused biconic components and, once assembled and terminated, are fully tested for environmental, mechanical and optical integrity. All optical coupler modules are designed to customer specifications and are available in a variety of package platforms, including LGX(R), RU (19" or 23") and custom designs. Features Applications * Telcordia qualified components and connectors * Low loss * Low uniformity * Available in LGX(R), RU and custom designs * Standard and custom ratios * Rugged construction to ensure environmental, mechanical and optical integrity * Termination options include SC, ST(R), FC and LC * Module color is central office white * * * * * CATV Telco Wide Area Networks Fiber Monitoring Systems Military systems Ordering Information C Package Type (First Character) C = LGX(R) Compatible D = 19" Rack Mountable 0102 50 00 20 Input/Output Ports Coupling Ratio 0102 = 1 x 2 0103 = 1 x 3 0104 = 1 x 4 0105 = 1 x 5 0106 = 1 x 6 0108 = 1 x 8 0110 = 1 x 10 (First Character) 50 = 50% 45 = 45% 40 = 40% 35 = 35% 33 = 33% 30 = 30% 25 = 25% 20 = 20% 15 = 15% 10 = 10% 5 = 5% WDM ASC F Configuration Input Connector/ Adapter A = Input Rear Adapter Output Front Pigtail/Jumper C = Input Rear Adapter Output Front Adapter D = Input Front Pigtail/ Jumper Output Front Adapter E = Input Front Pigtail/ Jumper Output Front Pigtail/Jumper F = Input Front Adapter Output Front Adapter G = Input Front Adapter Output Front Pigtail/Jumper 00 ASC 00 Input Pigtail Length (M) Output Connector/ Adapter Output Pigtail Length (M) ASC = Angle SC 01 = 1 meter AFC = Angle FC 00 = Adapter USC = Ultra SC UFC = Ultra FC SST = Super ST ULC = Ultra LC 000 = Non-connectorized ASC = Angle SC 01 = 1 meter AFC = Angle FC 00 = Adapter USC = Ultra SC UFC = Ultra FC SST = Super ST ULC = Ultra LC 000 = Non-connectorized Note: Dynamic field expands to accommodate 1XN configurations (Second Character) 00 = WDM (Third Character) 20 = Isolation 40 = Isolation LGX is a registered trademark of Furukawa Electric North America, Inc. (c) 2002, AFL Telecommunications, all rights reserved. Revision 0, 10.05.05 Specifications are subject to change without notice. 39 Ruggedized Wideband Couplers Enhancing AFL Telecommunications' wideband coupler offering are two package styles for ruggedized versions of these reliable, standardized couplers. 3mm and 900um furcated pigtail options and a variety of connector styles are offered in both single-mode and multimode applications. All AFL Telecommunications' couplers conform to stringent environmental and mechanical standards to provide high reliablity in a variety of customer applications. Features Applications * * * * * * * * * * * Dual window wideband operation Low insertion loss Low PDL High Directivity Long term field application Environmentally stable over -40C to +85C Telecommunications CATV LAN Fiber in the Loop Network monitoring Ordering Information T 0102 50 Package Type Split Ratio Configuration T = 900m Diameter Leads 50 = 50/50% 45 = 45/55% 40 = 40/60% 35 = 35/65% 30 = 30/70% 25 = 25/75% 20 = 20/80% 15 = 15/85% 10 = 10/90% 5 = 5/95% S = Single-mode 3 = 3mm Diameter Leads Output Leads 0102 = 1 x 2 ASC S Input Connector Options 01 ASC 01 Input Pigtail Length (M) Output Connector/ Adapter Output Pigtail Length (M) ASC = Angle SC (Examples) AFC = Angle FC 01 = 1 meter USC = Ultra SC 02 = 2 meters UFC = Ultra FC SST = Super ST ULC = Ultra LC 000 = Non-connectorized M = Multimode ASC = Angle SC (Examples) AFC = Angle FC 01 = 1 meter USC = Ultra SC 02 = 2 meters UFC = Ultra FC SST = Super ST ULC = Ultra LC 000 = Non-connectorized (c) 2002, AFL Telecommunications, all rights reserved. Revision 0, 4.01.05 Specifications are subject to change without notice. 40