AULT INCORPORATED
7105 Northland Terrace |Minneapolis, Minnesota 55428 |USATEL (1) 763-592-1900
FAX (1) 763-592-1911 |E-MAIL info@aultinc.com |WEB www.aultinc.com
© Copyright 2004 Ault Inc.
Specify the Input Configuration Code in your order.
Input Configuration
PW130
POE INJECTOR
UNIVERSAL 20 WATT
Input
Voltage 100-250 VAC -10%, +6%
Line Frequency 47 - 63 Hz Current 0.5A max. at 90
VAC input
Protection Internal primary current fuse,
Inrush limiting
Configuration Inlet type : IEC320-C14; IEC320-C8
Output
Combined Line and ±1% excluding cord
Load Voltage Regulation
Ripple 1% V p-p max for output current of
>0.175A
Transient Response 0.5 msec. for 50% load change typical
Holdup Time 18 msec min. @120 VAC
60 msec min. @240 VAC
Protection Foldback overcurrent protection
Short Circuit Protection
Cord and Connector Dual RJ45 jacks built into the enclosure
Safety Approvals
Agency Listings cULus: UL/CSA60950; TUV: EN60950; CE:
LVD, EMCD
Electrical
Topology Switching - Fixed frequency flyback
Dielectric Withstand 3000 VAC, 4250 VDC primary- secondary
500 VDC secondary-ground
Spacing 6.4mm primary-secondary
Leakage Current Less than 750 uA
Efficiency Minimum 65%
EMI Complies with EMC Directives
CE CE Compliant
MTBF 100,000 Calculated Hours
Environmental
Operating Temperature 0º to 40ºC with no derating
Storage Temperature -30º to +85ºC
Relative Humidity 5% to 95% non-condensing
Altitude 0-10,000 feet
Cooling Convectional - non vented case
Mechanical
Case Dimensions 107.9L x 66.5W x 38.6H (mm)
Case Material Black, 94V0 Polycarbonate
Weight 7 Ounces, 198 grams