Simple Solid State Contactors G3J CSM_G3J_DS_E_3_1 Solid State Contactors That Can Drive 3phase Motors Frequently, and Achieve Harmonized Protection with Thermal Overload Relays * Harmonized protection with thermal overload relays complying with IEC 947-4-1 (Class 10A/10); can be used like a standard contactor. * Certified for UL and CSA. * Mount with screws or to DIN tracks. * Compact monoblock construction (W: 80 x H: 100 x D: 100 mm) with a heat sink. * Snubber circuit and varistor are built-in. * Operation indicator. * Two-element models added to series. Refer to Safety Precautions for All Solid State Relays. Model Number Structure Model Number Legend G3J-@@@@@@-@ 1 2 3 4 5 6 7 8 5. Rated Load Current 11: 11.1 A (200-V models) 05: 4.8 A (200-V models) 6. Terminal Type B: Screw terminals 7. Zero Cross Function L: Not equipped with zero cross function 8. Number of Elements Blank: Standard models (3 elements) 2: 2 elements 1. Basic Model Name G3J: Solid State Contactor 2. Load Power Supply Blank: AC output 3. Functions Blank: Simple models 4. Rated Load Power Supply Voltage 2: 200 VAC Appearance Output terminals Operation indicator Input terminals Output terminals 1 G3J Ordering Information List of Models Number of elements 3 Insulation method Rated supply voltage Phototriac 12 to 24 VDC Photocoupler 100 to 240 VAC Applicable motor 2.2 kW (11.1 A) Model 200 to 220 VAC 0.75 kW (4.8 A) 2 Phototriac 12 to 24 VDC Photocoupler 100 to 240 VAC G3J-211BL G3J-205BL 2.2 kW (11.1 A) G3J-211BL 0.75 kW (4.8 A) G3J-205BL 2.2 kW (11.1 A) G3J-211BL-2 0.75 kW (4.8 A) G3J-205BL-2 2.2 kW (11.1 A) G3J-211BL-2 0.75 kW (4.8 A) G3J-205BL-2 Note: When ordering, specify the rated supply voltage. Accessories (Order Separately) Mounting Bracket Model R99-14 FOR G3J (See note.) Note: Use this Bracket when mounting Thermal Relay to a G3J-series SSR. Specifications Ratings (at an Ambient Temperature of 25C) Operation Circuit Item DC-input models AC-input models Rated supply voltage 12 to 24 VDC 100 to 240 VAC (50/60 Hz) Operating voltage range 9.6 to 26.4 VDC 75 to 264 VAC (50/60 Hz) Rated input current (impedance) 15 mA max. (at 12 to 24 VDC) 36 k 20% (100 to 240 VAC) Must operate voltage 9.6 VDC max. 75 VAC max. Must release voltage 3.6 VDC min. 20 VAC min. Main Circuit Item G3J-211BL, G3J-211BL-2 G3J-205BL, G3J-205BL-2 Rated load voltage 100 to 240 VAC (50/60 Hz) Load voltage range 75 to 264 VAC (50/60 Hz) Rated carry current (See note 3.) 11.1 A (Ta = 40C) Min. load current 0.1 A Peak-value current resistivity 350 A, 60 Hz, 1 cycle Overload resistance Refer to Safety Precautions for the G3J-T, G3J-S, and G3J. Closed current (effective value) AC3 111 A 48 A AC4 133.2 A 57.6 A Breaking current (effective value) AC3 88.8 A 38.4 A AC4 111 A 48 A Applicable load 3-phase inductive 200 to 220 VAC, 2.2 kW, (11.1 A) 200 to 220 VAC, 0.75 kW, (4.8 A) motor (AC3 AC4 Motors passing the AC3-class, AC4-class, and AC53-a-class switching frequency test (Ta = 40C) AC53-a) under conditions specified by OMRON. Refer to Safety Precautions for the G3J-T, G3J-S, and G3J. 4.8 A (Ta = 40C) 150 A, 60 Hz, 1 cycle Single-phase motor (AC3) (See note 1.) 100 VAC, 0.4 kW (11.1 A) 200 VAC, 0.75 kW (8.8 A) 100 VAC, 0.1 kW, (5.1 A) 200 VAC, 0.4 kW (5.5 A) (See note 2.) Resistive load (AC1) 100 to 240 VAC, 11.1 A 100 to 240 VAC, 4.8 A Note: 1. With 2-element models, L2 and T2 are shorted internally. 2 G3J 2. When using 0.75-W models with 3 poles ON simultaneously, use either combination at 4.8 A max. 3. The rated carry current varies depending on the ambient temperature. Refer to Load Current vs. Ambient Temperature under Engineering Data in the Information Common to the G3J-T, G3J-S, and G3J for details. Characteristics Item DC-input models Operate time AC-input models 1 ms max. 50 ms max. 3/2 of the load power supply cycle time + 1 ms max. Release time 5/6 of the load power supply cycle time + 1 ms max. Output ON-voltage drop 1.6 VRMS max. Leakage current (See note.) 10 mA max. (at 200 VAC) Insulation resistance 100 M min. (at 500 VDC) Dielectric strength 2,500 VAC, 50/60 Hz for 1 min Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude Shock resistance Destruction: 294 m/s2 Ambient temperature Operating: Storage: -20C to 60C (with no icing or condensation) -30C to 70C (with no icing or condensation) Ambient humidity Operating: 45% to 85% Weight Approx. 700 g Standards UL508, CSA22.2 No. 14, IEC947-4-1 Note: With 2-element models, the S-phase leakage current will be larger by a factor of 3. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. 3 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: * Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. * Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. * Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 2009.1 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2009 All Right Reserved.