611 Industrial Way West, Eatontown, NJ 07724 tel: 732-460-0212 fax: 732-460-0214 sales@advanced-control.com www.advanced-control.com
Features:
Superior Flatness vs. Frequency
Wide Frequency Range
Improved Return Loss
Higher Power Handling
Applications:
Transmitter Monitoring
Missile Guidance Systems
Input to Low-Noise Amplifiers
Broadband Or Narrowband ECM Receivers
Power and Signal Monitors
Doppler Radar and Beacon Receivers
Matched units available for Multi-channel Receivers, Amplitude Comparator Systems and Discriminators
Laboratory Test Equipment
Flatness Low
Frequency vs Internal Level Standard Optional
Range Part (1) Frequency TSS Attenuation Sensitivity Case Case
(GHz) Number (+/-dB) (dBm) (dB) (mV/mW)(2) Styles Styles
2 - 4 ACSP2579NZ 0.2 -45 6 500 C8 C3,C15
0.01 - 8 ACSP2539NZ 0.5 -45 6 500 C3 C8,C15,C32,C74
7.9 - 8.4 ACSP2518NZ 0.1 -45 6 500 C3 C8,C15,C32
7.9 - 8.4 ACSP2519PZ 0.1 -48 3 1000 C3 C8,C15,C32
0.01 - 12.4 ACSP2663NZ 0.5/octave -45 6 500 C8 C15,C32
0.01 - 18 ACSP2544NZ 0.5/octave -45 6 500 C3 C15,C32
0.01 - 18 ACSP2551NZ 0.5/octave -44 7 400 C3 C15,C32
5 - 18 ACSP2521PZ 0.5/octave -44 6 500 C3 C15,C32
0.01 - 20 ACSP2643NZ 0.5/octave -46 3 1000 C3 C15,C32
0.01 - 20 ACSP2644NZ 1.0 -44 7 500 C15 C3,C32
NOTES:
1) Standard output polarity is negative unless otherwise noted. If positive output is required, substitute ”P” for “N” in part number.
2) Measured into an open circuit load (>10k ohm).
Detectors with internal attenuators are often requested. They are typically used
in circuits where an improved RF match is needed or where the power levels
applied are higher than is typical for low level detectors. Frequently, they are
used in laboratory applications with associated instruments such as broadband
power leveling or monitoring. These detectors are all zero bias, making them
convenient to use.
PADDED ZERO BIAS SCHOTTKY DETECTORS
611 Industrial Way West, Eatontown, NJ 07724 tel: 732-460-0212 fax: 732-460-0214 sales@advanced-control.com www.advanced-control.com
SMA MALE
0.250-36UNS-2B
(OUTPUT)
SMA MALE
0.250-36UNS-2B
(INPUT)
Ø.38±0.02
1.55±0.02
ENVIRONMENTAL SPECIFICATIONS: SCREENING :
MIL-E-5400, MIL-STD-202, MIL-E-16400 Standard Screening:
Storage Temp: -65°C to +150°C Internal Visual per MIL-STD-883, Method 2017
Humidity: MIL-STD-202F, M103, Cond B Temperature Cycle: -65°C to +100°C, 10 cycles
Shock: MIL-STD-202F, M213, Cond B Optional High-Rel Screening (Ref MIL-PRF-38534):
Altitude: MIL-STD-202F, M105, Cond B Internal Visual per MIL-STD-883, Method 2017
Vibration : MIL-STD-202F, M204, Cond B Stabilization Bake per MIL-STD-883, Method 1008
Thermal Shock: MIL-STD-202F, M107, Cond A Temperature Cycle per MIL-STD-883, Method 1010
Temperature Cycle: MIL-STD-202F, M105C, Cond D Constant Acceleration per MIL-STD-883, Method 2001
Maximum Input Power: +23dBm Burn-in per MIL-STD-883, Method 1015
Leak Test per MIL-STD-883, Method 1014
External Visual per MIL-STD-883, Method 2009
CASE STYLE C3 CASE STYLE C8
CASE STYLE C15 CASE STYLE C32 CASE STYLE C74
Part Number Ordering Information: Example: ACSP2663NZC3
ACSP2663: Padded Zero Bias Schottky Detector, 0.01 – 12.4GHz
N: Negative output polarity
Z: Zero bias
C3: Package type
SP-0205
BNC
FEMALE
(OUTPUT)
SMA
MALE
(INPUT)
2.00
0.43
0.42
Ø0.500
2.80±0.020
BNC
FEMALE
(OUTPUT)
Ø0.625
TYPE-N
MALE
(INPUT)
Ø0.312
SMA
FEMALE
(OUTPUT)
SMA
MALE
(INPUT)
1.16±0.020
Ø0.312
1.32±0.020
SMA
MALE
(INPUT)
SMA
FEMALE
(OUTPUT)