611 Industrial Way West, Eatontown, NJ 07724 tel: 732-460-0212 fax: 732-460-0214 sales@advanced-control.com www.advanced-control.com
Features:
• Superior Flatness vs. Frequency
• Wide Frequency Range
• Improved Return Loss
• Higher Power Handling
Applications:
• Transmitter Monitoring
• Missile Guidance Systems
• Input to Low-Noise Amplifiers
• Broadband Or Narrowband ECM Receivers
• Power and Signal Monitors
• Doppler Radar and Beacon Receivers
• Matched units available for Multi-channel Receivers, Amplitude Comparator Systems and Discriminators
• Laboratory Test Equipment
Flatness Low
Frequency vs Internal Level Standard Optional
Range Part (1) Frequency TSS Attenuation Sensitivity Case Case
(GHz) Number (+/-dB) (dBm) (dB) (mV/mW)(2) Styles Styles
2 - 4 ACSP2579NZ 0.2 -45 6 500 C8 C3,C15
0.01 - 8 ACSP2539NZ 0.5 -45 6 500 C3 C8,C15,C32,C74
7.9 - 8.4 ACSP2518NZ 0.1 -45 6 500 C3 C8,C15,C32
7.9 - 8.4 ACSP2519PZ 0.1 -48 3 1000 C3 C8,C15,C32
0.01 - 12.4 ACSP2663NZ 0.5/octave -45 6 500 C8 C15,C32
0.01 - 18 ACSP2544NZ 0.5/octave -45 6 500 C3 C15,C32
0.01 - 18 ACSP2551NZ 0.5/octave -44 7 400 C3 C15,C32
5 - 18 ACSP2521PZ 0.5/octave -44 6 500 C3 C15,C32
0.01 - 20 ACSP2643NZ 0.5/octave -46 3 1000 C3 C15,C32
0.01 - 20 ACSP2644NZ 1.0 -44 7 500 C15 C3,C32
NOTES:
1) Standard output polarity is negative unless otherwise noted. If positive output is required, substitute ”P” for “N” in part number.
2) Measured into an open circuit load (>10k ohm).
Detectors with internal attenuators are often requested. They are typically used
in circuits where an improved RF match is needed or where the power levels
applied are higher than is typical for low level detectors. Frequently, they are
used in laboratory applications with associated instruments such as broadband
power leveling or monitoring. These detectors are all zero bias, making them
convenient to use.
PADDED ZERO BIAS SCHOTTKY DETECTORS