COUNT/RATE COUNT/RATE
Products and specifications subject to change without notice.
Consult factory for application assistance.
204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com
7-6
2108H SERIES
ELAPSED TIME INDICATOR
•6 Digit .3˝ High LCD Display
•4 Selectable Time Ranges
Hours, 1/10 Hours
Minutes, 1/10 Minutes
Seconds, 1/10 Seconds
Hours, Minutes, Seconds
SPECIFICATIONS:
Power Supply . . . . . . . . . . . . . . . . Replaceable lithium battery, 5 year life
Display . . . . . . . . . . . . . . . . . . . . . . 6 Digit LCD
Display height . . . . . . . . . . . . . . . . 0.3˝
Accuracy . . . . . . . . . . . . . . . . . . . . +50 PPM (Quartz)
Input
Start/Stop and Reset Inputs . . . Dry Contact
. . . . . . . . . . . . . . . . . . . . . . . . . . . . NPN open collector transistor
Min. Closure Time . . . . . . . . . . 40 ms (start/stop), 100 ms (reset)
Memory . . . . . . . . . . . . . . . . . . . . . Yes, 5 year life
Connection . . . . . . . . . . . . . . . . . . Screw terminal
Front panel rating . . . . . . . . . . . . . IP64
Operating temperature . . . . . . . . . +32 to 131°F (0 to 55°C)
Storage temperature . . . . . . . . . . -13 to 158°F (-25 to 70°C)
Weight . . . . . . . . . . . . . . . . . . . . . . 2.1 oz. (60g)
GENERAL FEATURES:
The 2108H Series is an elapsed time indicator in a DIN-sized
24 x 48mm (.95˝ x 1.89˝) enclosure. Unit is compact with a
37.5mm (1.48˝) depth. The start/stop input can be a contact
closure or an NPN open collector transistor. The unit is powered
by a replaceable lithium battery.
22
+0.3
-0
20
44.8
+0.5
-0 30
Press here to remove.
WIRING:
87 610 440
1- Reset Input
2- Enable Reset
3- Common
4- Prog.
5- Start/Stop
ORDERING INFORMATION:
87 610 440
DIMENSIONS: (mm)
CONFORMITY:
Electromagnetic environment
Radiated field IEC 1000-4-3, level 3, 10 V/M, 26 MHz to 1 GHz
Fast transients IEC 1000-4-4, level 3, 1 KV
Damped oscillatory wave IEC 255.4, level 3, 1 KV
Electrostatic discharge IEC 1000-4-2, level 3, 8 KV
1,4,5
32108 H
2
12108 H
Start/Stop input
Prog.
Reset
Enable Reset
input
1234 5
Prog.
Enable
Reset
Reset
100 ms Start/Stop
UL
®
CUS LISTED