Data Sheet FieldIT SS/265JS_3 2600T Series Pressure Transmitters Model 265JS Differential and absolute selectable maximum working pressure up to 41MPa, 5945psi Base accuracy : 0.04% Span limits - 0.05 to 10000kPa, 0.2inH2O to 1450psi differential pressure - 0.6 to 41MPa, 87 to 5945psia absolute pressure True draft range and ultra performance dual output transmitter Reliable sensing system coupled with very latest digital technologies - provides large turn down ratio up to 100:1 Comprehensive sensor choice - optimize in-use total performance and stability 5-year stability Flexible configuration facilities - provided locally via local keys combined with LCD indicator or via hand held terminal or PC configuration platform Multiple protocol availability - provides integration with HART(R), PROFIBUS PA and FOUNDATION Fieldbus platforms offering interchangeability and transmitter upgrade capabilities Full compliance with PED category III ABB 2600T Series Engineered solutions for all applications 2600T Pressure Transmitters Model 265JS SS/265JS_3 Functional Specifications Operative limits Range and span limits Temperature limits C (F) : - Ambient (is the operating temperature) differential pressure sensors Silicone oil filling: -40C and +85C (-40F and +185F) Sensor Code - Upper Range Limit (URL) Lower Range Limit (LRL) Minimum Span A 1kPa 10mbar 4inH2O -1kPa -10mbar -4inH2O 0.05kPa 0.5mbar 0.2inH2O C 6kPa 60mbar 24inH2O -6kPa -60mbar -24inH2O 0.2kPa 2mbar 0.8inH2O F 40kPa 400mbar 160inH2O -40kPa -400mbar -160inH2O 0.4kPa 4mbar 1.6inH2O L 250kPa 2500mbar 1000inH2O -250kPa -2500mbar -1000inH2O 2.5kPa 25mbar 10inH2O N 2000kPa 20bar 290psi -2000kPa -20bar -290psi 20kPa 0.2bar 2.9psi R 10000kPa 100bar 1450psi -10000kPa -100bar -1450psi 100kPa 1bar 14.5psi absolute pressure sensors Sensor Code Upper Range Limit (URL) 1 600kPa 6bar 87psi 2 2000kPa 20bar 290psi 3 10000kPa 100bar 1450psi 4 41000kPa 410bar 5945psi Inert filling: -20C and +85C (-4F and +185F) Lower ambient limit for Viton and PTFE gaskets: -20C (-4F) Note : For Hazardous Atmosphere applications see the temperature range specified on the certificate/approval relevant to the aimed type of protection Process Lower limit - refer to lower ambient limits Upper limit - Silicone oil: 121C (250F) for working pressure above 10kPa abs, 100mbar abs, 1.45psia(1) - Inert fluid: 121C (250F) (2) for working pressure above atmospheric pressure (1) 85C (185F) for application below 10kPa abs, 100mbar abs, 1.45psia down to 3.5 kPa abs, 35mbar abs, 0.5psia (2) 85C (185F) for application below atmospheric pressure down to 40kPa abs, 400mbar abs, 5.8psia. Storage Lower limit: -50C (-58F); -40C (-40F) for LCD indicators Lower Range Limit (LRL) Minimum Span 0abs 6kPa 0.06bar 0.87psi 0abs 20kPa 0.2bar 2.9psi 0abs 100kPa 1bar 14.5psi 0abs 410kPa 4.1bar 59.5psi Upper limit: +85C (+185F) Pressure limits Overpressure limits (without damage to the transmitter) Lower limit - 0.5kPa abs, 5mbar abs, 0.07psia for silicone oil - 40kPa abs, 400mbar abs, 5.8psia for inert fluid Upper limit - 0.6MPa, 6bar, 87psi for differential pressure sensor code A - 2MPa, 20bar, 290psi or 10MPa, 100bar, 1450psi or 41MPa, 410bar, 5945psi for differential pressure sensor codes C, F, L, N, R according to selected code variant Static pressure Span limits Maximum span = URL (can be further adjusted up to URL (TD = 0.5) for differential pressure sensors, within the range limits). IT IS RECOMMENDED TO SELECT THE TRANSMITTER SENSOR CODE PROVIDING THE TURNDOWN VALUE AS LOWEST AS POSSIBLE TO OPTIMIZE PERFORMANCE CHARACTERISTICS. Zero suppression and elevation Zero and span of differential pressure sensors can be adjusted to any value within the range limits detailed in the table as long as: - calibrated span minimum span Damping Adjustable time constant : 0 to 60s. This is in addition to sensor response time Turn on time Operation within specification in less than 2.5s with minimum damping. Insulation resistance > 100M at 1000VDC (terminals to earth) 2 Transmitters for differential pressure model 265JS operates within specifications between the following limits Lower limit - 3.5kPa abs, 35mbar abs, 0.5psia for silicone oil - 40kPa abs, 400mbar abs, 5.8psia for inert fluid Upper limit - 0.6MPa, 6bar, 87psi for differential pressure sensor code A - 2MPa, 20bar, 290psi or 10MPa, 100bar, 1450psi or 41MPa, 410bar, 5945psi for differential pressure sensor codes C, F, L, N, R according to selected code variant Proof pressure The transmitter can be exposed without leaking to line pressure of up 1.5 times the nominal pressure simultaneously on both sides. 2600T Pressure Transmitters Model 265JS Environmental limits Electromagnetic compatibility (EMC) Definition Class 3 Radio suppression Limit class B (according to EN 550011) Fulfills NAMUR recommendation Low voltage directive Comply with 73/23/EEC Pressure equipment directive (PED) Instruments with maximum working pressure 41MPa, 410bar, 5945psi comply with 97/23/EEC Category III module H. Humidity Relative humidity: up to 100% annual average Condensing, icing: admissible Vibration resistance Accelerations up to 2g at frequency up to 1000Hz (according to IEC 60068-2-26) Shock resistance (according to IEC 60068-2-27) Acceleration: 50g Duration: 11ms Wet and dust-laden atmospheres The transmitter is dust and sand tight and protected against immersion effects as defined by IEC EN60529 (1989) to IP 67 (IP 68 on request) or by NEMA to 4X or by JIS to C0920. HHazardous atmospheres - Transmitters of the type of protection "Intrinsically safe EEx ia" according to the directions 94 / 9 / EC (ATEX) Transmitter with 4 to 20mA output signal and HART communication Marking (DIN EN 50 014): II 1/2 GD T50C EEx ia IIC T6 or resp. II 1/2 GD T95C EEx ia IIC T4 Supply and signal circuit type of protection Intrinsic Safety EEx ib IIB/IIC resp. EEx ia IIB/IIC for connection to supply units with maximum values: II 1/2 GD T50C EEx ia resp. ib IIC T6 resp. II 1/2 GD T95C EEx ia resp. ib IIC T4 for Temperature class T4 resp. T95C: Ui = 30V Ii = 200mA Pi = 0.8W for T4 with Ta = (-40 to +85)C / (-40 to +185)F Pi = 1.0W for T4 with Ta = (-40 to +70)C / (-40 to +158)F for Temperature class T6 resp. T50C: Pi = 0.7W for T6 with Ta = (-40 to +40)C / (-40 to +104)F effective internal capacitance, Ci 10nF effective internal inductance, negligible. Fieldbus transmitters (PROFIBUS PA / FOUNDATION Fieldbus) Marking (DIN EN 50 014): II 1/2 GD T50C EEx ia IIC T6 or resp. II 1/2 GD T95C EEx ia IIC T4 Supply and signal circuit type of protection Intrinsic Safety EEx ib IIB/IIC resp. EEx ia IIB/IIC for connection to FISCO supply units with rectangular or trapezoidal characteristics with maximum values: II 1/2 G EEx ia respectively ib IIC T4/T6 Ui = 17.5V Ii = 360mA Pi = 2.52W II 1/2 G EEx ia respectively ib IIB T4/T6 Ui = 17.5V Ii = 380mA Pi = 5.32W SS/265JS_3 resp. for connection to supply unit or barrier with linear characteristics with maximum values: II 1/2 G EEx ia respectively ib IIC T4/T6 Ui = 24V li = 250mA Pi = 1.2W effective internal inductance Li 10 H, effective internal capacitance Ci 0 Maximum permissible ambient temperatures depending on the temperature class: T4: -40C to +85C (-40F to +185F) T5, T6: -40C to +40C (-40F to +104F) - Transmitters of the type of protection "flameproof enclosure EEx d" according to the directions 94 /9 / EC (ATEX) Transmitter with 4 to 20mA output signal and HART communication and Fieldbus transmitters (PROFIBUS PA / FOUNDATION Fieldbus) Marking (DIN EN 50 014): II 1/2 G EEx d IIC T6 Ambient temperature range: -40C to +75C (-40F to +167F) - Transmitters of category 3 for the application in "Zone 2" Transmitter with 4 to 20mA output signal and HART communication according to the directions 94 / 9 / EC (ATEX) Marking (DIN EN 50 014): II 3 GD T50C EEx nL IIC T6 or resp. II 3 GD T95C EEx nL IIC T4 Operating conditions: Supply and signal circuit (terminals signal +/-): U 45V I 22.5mA Ambient temperature range: Temperature class T4 Ta=-40C to +85C (-40F to +185F) Temperature class T5, T6 Ta=-40C to +40C (-40F to +104F) - Factory Mutual (FM) Transmitter with 4 to 20mA output signal and HART communication Intrinsically safe: Class I; Division 1; Groups A, B, C, D; Class I; Zone 0; Group IIC; AEx ia IIC Degree of protection : NEMA Type 4X (indoor or outdoor) Permissible ambient temperature depending on temperature class Umax = 30V, Ci = 10.5nF, Li = 10H Ambient Temperature -40 to +85 -40 to +70 -40 to +40 -40 to +40 C (-40 to +185 C (-40 to +129 C (-40 to +104 C (-40 to +104 F) F) F) F) Temperature Imax class T4 200mA T4 200mA T5 25mA T6 25mA Pi 0.8W 1W 0.75W 0.5W Fieldbus transmitters (PROFIBUS PA/FOUNDATION Fieldbus) Intrinsically Safe : Class I, II and III; Division 1; Groups A, B, C, D, E, F, G; Class I; Zone 0, AEx ia Group IIC T6; T4 Non-incendive Class I, II and III, Division 2; Groups A, B, C, D, F, G Transmitter with 4 to 20mA output signal and HART communication and Fieldbus transmitters (PROFIBUS PA/FOUNDATION Fieldbus) Explosion-Proof: Class I; Division 1; Groups A, B, C, D; Class II/III, Division 1; Groups E, F, G Degree of protection : NEMA Type 4X (indoor or outdoor) - Canadian Standard (CSA) Transmitter with 4 to 20mA output signal and HART communication and Fieldbus transmitters (PROFIBUS PA/FOUNDATION Fieldbus) Explosion-Proof: Class I; Division 1; Groups B, C, D Class II; Division 1; Groups E, F, G Class III Degree of protection : NEMA Type 4X (indoor or outdoor) 3 2600T Pressure Transmitters Model 265JS SS/265JS_3 Electrical Characteristics and Options Optional indicators HART digital communication and 4 to 20mA output Integral display Power Supply The transmitter operates from 10.5 to 45VDC with no load and is protected against reverse polarity connection (additional load allows operations over 45VDC). Minimum power supply is 14VDC with backlit indicator. For EEx ia and other intrinsically safe approval power supply must not exceed 30VDC. 2-line, 6-character 19-segment alphanumeric display with additional bar chart display, optionally with back illumination. User-specific display: percentage of the output current or output current in mA or free process variable Diagnostic message, alarms, measuring range infringements and changes in the configuration are also displayed. Ripple Maximum permissible voltage ripple of power supply during the communication: Optional surge protection Up to 4kV 7Vpp at f = 50 to 100Hz - voltage 1.2s rise time / 50s delay time to half value 1Vpp at f = 100 to 200Hz - current 8s rise time / 20s delay time to half value 0.2Vpp at f = 200 to 300Hz Load limitations 4 to 20mA and HART total loop resistance : Supply voltage - min. operating voltage (VDC) --------------------------------------- 22.5 mA A minimum of 250 is required for HART communication. R(k) = Output signal Two-wire 4 to 20mA related to differential pressure. HART(R) communication provides digital process variable (%, mA or engineering units) and absolute pressure (engineering unit) superimposed on 4 to 20mA signal, with protocol based on Bell 202 FSK standard. Output current limits (to NAMUR standard) Overload condition - Lower limit: 3.8mA (configurable down to 3.5mA) - Upper limit: 20.5mA (configurable up to 22.5mA) Alarm current Min. alarm current: configurable from 3.5mA to 4mA, standard setting: 3.6mA Max. alarm current: configurable from 20mA to 22.5mA, standard setting: 21mA Standard setting: max. alarm current 4 2600T Pressure Transmitters Model 265JS SS/265JS_3 PROFIBUS PA output FOUNDATION Fieldbus output Device type Power supply Pressure transmitter compliant to Profile 3.0 Class A & B; ident. number 04C2 HEX. Power supply The transmitter operates from 10.2 to 32VDC with no polarity. For EEx ia approval power supply must not exceed 17.5VDC. Intrinsic safety installation according to FISCO model. Current consumption operating (quiescent): 11.7mA fault current limiting: 17.3mA max. Output signal Physical layer in compliance to IEC 1158-2/EN 61158-2 with transmission to Manchester II modulation, at 31.25kbit/sec. Output interface PROFIBUS PA communication according to Profibus DP50170 Part 2/ DIN 19245 part 1-3. Output update time 40ms Function blocks 2 Analog Input, 1 Transducer, 1 Physical Integral display 2-line, 6-character 19-segment alphanumeric display with additional bar chart display, optionally with back illumination. User-specific display: percentage of the output or The transmitter operates from 10.2 to 32VDC polarity independent. For EEx ia approval power supply must not exceed 24VDC (entity certification) or 17.5VDC (FISCO certification), according to FF-816. Current consumption operating (quiescent): 11.7mA fault current limiting: 17.3mA max. Output signal Physical layer in compliance to IEC 1158-2/EN 61158-2 with transmission to Manchester II modulation, at 31.25kbit/sec. Function blocks/execution period 2 standard Analog Input blocks/25ms max (each) Additional blocks 1 custom Pressure with calibration Transducer block 1 enhanced Resource block Number of link objects 10 Number of VCRs 16 Output interface FOUNDATION fieldbus digital communication protocol to standard H1, compliant to specification V. 1.5; FF registration in progress. Integral display OUT (analog input function block) 2-line, 6-character 19-segment alphanumeric display with additional bar chart display, optionally with back illumination. User-specific display: Diagnostic message, alarms, measuring range infringements and changes in the configuration are also displayed. percentage of the output or Transmitter failure mode Permanent self-diagnostic; possible errors indicated in diagnostic parameters and in the status of process values. OUT (analog input function block) Diagnostic message, alarms, measuring range infringements and changes in the configuration are also displayed. Transmitter failure mode Permanent self-diagnostic; possible errors indicated in diagnostic parameters and in the status of process values. 5 2600T Pressure Transmitters Model 265JS Performance specifications Stated at reference condition to IEC 60770 ambient temperature of 20C (68F), relative humidity of 65%, atmospheric pressure of 1013hPa (1013mbar), mounting position with vertical diaphragm and zero based range for transmitter with isolating diaphragms in Hastelloy and silicone oil fill and HART digital trim values equal to 4-20mA span end points, in linear mode. SS/265JS_3 Operating influences Ambient temperature (for turndown up to 15:1) per 20K (36F) change between the limits of -20C to +65C (-4 to +150F) for differential pressure sensor Unless otherwise specified, errors are quoted as % of span. - (0.03% URL + 0.05% span) Some performance data (based to URL) are affected by the actual turndown (TD) as ratio between Upper Range Limit (URL) and calibrated span. per 20K (36F) change between the limits of -40C to +80C (-40F to +176F) IT IS RECOMMENDED TO SELECT THE TRANSMITTER SENSOR CODE PROVIDING THE TURNDOWN VALUE AS LOWEST AS POSSIBLE TO OPTIMIZE PERFORMANCE CHARACTERISTICS. for absolute pressure sensor - (0.08% URL + 0.08% span) limited to (0.1% URL + 0.1% span) per the complete temperature range of 120K (216F) Dynamic performance (according to IEC 61298-1 definition) Standard configuration for instruments with turndown up to 30:1 and linear output characteristics. Dead time: 30ms Static pressure (zero errors can be calibrated out at line pressure) Measuring range 150ms - sensor C: 400ms - sensor A: 1000ms Accuracy rating Sensor R on zero up to 100bar: 0.05% URL > 100bar: 0.05%URL/100bar up to 100bar: 0.1% URL > 100bar: 0.1% URL/100bar on span up to 2bar: 0.05% span > 2bar: 0.05% span/bar up to 100bar: 0.05% span > 100bar: 0.05%span/100bar up to 100bar: 0.1% span > 100bar: 0.1% span/100bar Supply voltage % of calibrated span, including combined effects of terminal based linearity, hysteresis and repeatability. For fieldbus versions SPAN refer to Analog Input Function Block outscale range For differential pressure sensor - 0.04% for TD from 1:1 to 10:1 URL - (0.04 + 0.005 x Span Sensors C, F, L, N up to 2bar: 0.05% URL > 2bar: 0.05% URL/bar Time constant (63.2% of total step change): - sensors F to R: Sensor A - 0.05)% for TD greater than 10:1 For absolute pressure sensor - 0.1% URL of absolute pressure sensor Within voltage/load specified limits the total effect is less than 0.001% of URL per volt. Load Within load/voltage specified limits the total effect is negligible. Radio frequency interference Total effect : less than 0.05% of span from 20 to 1000MHz and for field strengths up to 10V/m when tested with unshielded conduit, with or without meter. Common mode interference No effect from 250Vrms @ 50Hz, or 50VDC Mounting position Rotations in plane of diaphragm have negligible effect. A tilt from vertical causes a zero shift of sin x 0.35kPa (3.5 mbar, 1.4inH2O) of URL which can be corrected with the zero adjustment. No span effect. Stability 0.10% of URL over a thirty-six-month period Vibration effect 0.10% of URL (according to IEC 61298-3) 6 2600T Pressure Transmitters Model 265JS SS/265JS_3 Physical Specification Optional extras (Refer to ordering information sheets for variant availability related to specific model or versions code) Mounting brackets Materials Process isolating diaphragms (*) AISI 316 L ss; Hastelloy C276TM; Monel 400TM; Tantalum; Process flanges, adapters, plugs and drain/vent valves (*) AISI 316 L ss; Hastelloy C276TM; Monel 400TM, Kynar (PVDF) Sensor fill fluid Silicone oil; inert fill (Carbon Fluoride). Mounting bracket AISI 316 L ss. Gaskets (*) For vertical and horizontal 60mm. (2in) pipes or wall mounting. Integral display plug-in rotatable LCD indicator Supplemental customer tag AISI 316 ss tag fastened to the transmitter with stainless steel wire for customer's tag data up to a maximum of 30 characters and spaces. Surge protection not available with ATEX-EEx nL or PROFIBUS PA / FOUNDATION Fieldbus with Intrinsic Safety EEx i or FM-Intrinsically Safe. Cleaning procedure for oxygen service Hydrogen preparation VitonTM; Perbunan (NBR); EPDM; Test Certificates (test, design, calibration, material traceability) PTFE (for sensors C, F, L, N, R) or FEP coated VitonTM (for sensor A) Tag and manual language Sensor housing AISI 316 L ss. Bolts and nuts Stainless steel bolts and nuts Class A4-70 per ISO 3506, in compliance with NACE MR0175 Class II. Electronic housing and covers Barrel version - Low-copper content aluminium alloy with baked epoxy finish; - AISI 316 L ss. Process connections on flanges: 1/4in NPT on process axis selectable with 7/16in-20 UNF fixing threads or DIN 19213 connection with M10 fixing threads for working pressure up to 16MPa, 160bar , 2320psi or M12 fixing threads for greater working pressure up to 41MPa, 410bar, 6000psi on adapters: 1/2in NPT on process axis centre distance: 54mm (2.13in ) on flange; 51,54 or 57mm (2.01, 2.13 or 2.24in) as per adapters fittings. Electrical connections DIN version Two 1/2 NPT or M20x1.5 threaded conduit entries, direct on housing. - Low-copper content aluminium alloy with baked epoxy finish. Communication connector (on request) Covers O-ring VitonTM. Local zero and span adjustments: Glass filled polycarbonate plastic (removable). Tagging AISI 316ss or plastic data plate attached to the electronics housing. Calibration Standard: at maximum span, zero based range, ambient temperature and pressure; Optional: at specified range and ambient conditions. - HART : straight or angle Harting Han 8U connector and one plug. - PROFIBUS PA, FOUNDATION Fieldbus : M12x1 or 7/8 (without mating female plug) Terminal block HART version: four terminals for signal/external meter wiring up to 2.5mm2 (14AWG) and four connection points for test and communication purposes. Fieldbus versions: two terminals for signal (bus connection) wiring up to 2.5mm2 (14AWG). Grounding Internal and external 4mm2 (12AWG) ground termination points are provided. Mounting position Transmitter can be mounted in any position. Electronics housing may be rotated by 360. A positive stop prevents over travel. Mass (without options) 3.5kg approx (8lb); add 1.5kg (3.4lb) for AISI housing. Add 650g (1.5lb) for packing. Packing Carton 23 x 25 x 27cm approx (9 x 10 x 11in). 7 2600T Pressure Transmitters Model 265JS Configuration Transmitter with HART communication and 4 to 20 mA Standard configuration Transmitters are factory calibrated to customer's specified range. Calibrated range and tag number are stamped on the type plate. If calibration range and tag data are not specified, the transmitter will be supplied configured as follows: 4 mA Zero 20 mA Upper Range Limit (URL) Output Linear Damping 0.125s Transmitter failure mode 21mA Any or all the above configurable parameters, including Lower range-value and Upper range-value which must be the same unit of measure, can be easily changed using the HART hand-held communicator or by a PC running the configuration software SMART VISION with DTM for 2600T. The transmitter database is customized with specified flange type and material, o-ring and filling liquid. Transmitter with PROFIBUS PA communication Transmitters are factory calibrated to customer's specified range. Calibrated range and tag number are stamped on the type plate. If calibration range and tag data are not specified, the transmitter will be supplied configured as follows: Measure Profile Pressure Engineering Unit mbar/bar Output scale 0% Lower Range Limit (LRL) Output scale 100% Upper Range Limit (URL) Output Linear Hi-Hi Limit Upper Range Limit (URL) Hi Limit Upper Range Limit (URL) Low Limit Lower Range Limit (LRL) Low-Low Limit Lower Range Limit (LRL) Limits hysteresis 0.5% of output scale PV filter 0.125s. Address 126 Any or all the above configurable parameters, including Lower range-value and Upper range-value which must be the same unit of measure, can be easily changed by a PC running the configuration software SMART VISION with DTM for 2600T. The transmitter database is customized with specified flange type and material, o-ring and filling liquid. 8 SS/265JS_3 Transmitter with FOUNDATION Fieldbus communication Transmitters are factory calibrated to customer's specified range. Calibrated range and tag number are stamped on the type plate. If calibration range and tag data are not specified, the transmitter will be supplied configured as follows: Measure Profile Pressure Engineering Unit mbar/bar Output scale 0% Lower Range Limit (LRL) Output scale 100% Upper Range Limit (URL) Output Linear Hi-Hi Limit Upper Range Limit (URL) Hi Limit : Upper Range Limit (URL) Low Limit Lower Range Limit (LRL) Low-Low Limit Lower Range Limit (LRL) Limits hysteresis 0.5% of output scale PV filter 0.125s Address Not necessary Any or all the above configurable parameters, including lower range value and upper range value which must be the same unit of measure, can be changed by any FOUNDATION Fieldbus compatible configurator. The transmitter database is customized with specified flange type and material, o-ring and filling liquid. TM Hastelloy is a Cabot Corporation trademark TM Monel is an International Nickel Co. trademark TM Viton is a Dupont de Nemour trademark (*) Wetted parts of the transmitter. 2600T Pressure Transmitters Model 265JS SS/265JS_3 MOUNTING DIMENSIONS (not for construction unless certified) - dimensions in mm (in) Transmitter with barrel housing 114 (4.49) 58 (2.28) 20 (0.79) Clearance for cover removal Terminal side 26 (1.02) Additional tag plate 61 (2.40) 30 (1.18) 41.3 (1.63) Process connection Drain/vent valve (side position) 108 (4.25) Transducer plate 186 (7.32) Housing rotation stop screw Threads for fixing screws (see process connection data) Space must be available to rotate the key-board cover 70 (2.76) 9 (0.35) 23 (0.91) with LCD indicator 54 (2.13) 96 (3.78) 71 (2.80) 90 (3.54) 83 (3.27) Identification plate Housing cover Captive screw for keys unit cover 117 (4.61) Electrical connection (with gland) Plate with keys legend 9 2600T Pressure Transmitters Model 265JS SS/265JS_3 Transmitter with DIN housing Transducer plate 96 (3.78) 54 (2.13) 117 (4.617 83 (3.27) 70 (2.76) 41.3 (1.63) Process connection Threads for fixing screws (see process connection data) Terminal side Identification plate Space must be available to rotate the key-board cover 43 (1.69) Electrical connection (with gland) Additional tag plate Electrical connection (with plug) Housing cover 27 (1.06) 48 (1.89) 20 (0.79) 139 (5.47) Housing rotation stop screw 90 (3.54) 61 (2.40) Captive screw for keys unit cover Plate with keys legend 20 (0.79) 107 (4.21) 138 (5.43) 168 (6.61) 10 23 (0.91) 2600T Pressure Transmitters Model 265JS SS/265JS_3 Possible mounting with bracket 72 (2.83) o 10 (0.4) o 11 (0.43) 60(2.36) 135.5 (5.33) 56(2.20) 136 (5.35) 72 (2.83) 57(2.24) 72 (2.83) 110 (4.33) 214 (8.43) Vertical pipe mounting Horizontal pipe mounting Vertical pipe mounting and transmitter above the mounting bracket Horizontal pipe mounting and transmitter above the mounting bracket 11 2600T Pressure Transmitters Model 265JS SS/265JS_3 Electrical connections Standard Terminal block and fieldbus connector versions Earthing/potential Output signal/ Test sockets for 4...20mA equalizing terminal power supply (not in function with fieldbus transmitters) 7/8" connector Cable entry Screw terminals for 0.5...2.5mm2 - wires 1 3 2 4 M12 x 1 connector 2 1 3 4 PIN (male) IDENTIFICATION FOUNDATION PROFIBUS Fieldbus PA 1 FFPA+ 2 FF+ GROUND 3 SHIELD PA- 4 GROUND SHIELD Mating female plug NOT SUPPLIED Harting Han 8U connector 1 2 + Harting pin identification (view onto socket) 12 2600T Pressure Transmitters Model 265JS SS/265JS_3 BASIC ORDERING INFORMATION model 265JS Differential and Absolute Pressure Transmitter Select one character or set of characters from each category and specify complete catalog number. Refer to additional ordering information code and specify one or more codes for each transmitter if additional options are required. 2 BASE MODEL - 1st to 5th characters 6 5 J S X X X X X X X Differential and absolute transmitter - BASE ACCURACY 0.04% SENSOR - Span limits - 6th character 0.05 and 1kPa 0.5 and 10mbar 0.2 and 6 kPa 2 and 60mbar 0.4 and 40kPa 4 and 400mbar 2.5 and 250kPa 25 and 2500mbar 20 and 2000kPa 0.2 and 20bar 100 and 10000kPa 1 and 100bar 0.2 and 4inH2O 0.8 and 24inH2O 1.6 and 160inH2O 10 and 1000inH2O 2.9 and 290psi 14.5 and 1450psi A C F L N R Static pressure range - 7th character 0 to 0.6MPa 0 to 2MPa 0 to 10MPa 0 to 41MPa 0 to 6bar 0 to 20bar 0 to 100bar 0 to 410bar 0 to 87psi 0 to 290psi 0 to 1450psi 0 to 5945psi (Note 1) (Note 2) (Note 2) (Note 2) 1 2 3 4 (Note 3) (Note 3) (Note 3) (Note 3) (Note 3) NACE NACE NACE NACE NACE NACE NACE NACE NACE NACE Diaphragm material / Fill fluid (wetted parts) - 8th character AISI 316 L ss Hastelloy C276TM Monel 400TM Monel 400TM gold plated Tantalum AISI 316 L ss Hastelloy C276TM Monel 400TM Monel 400TM gold plated Tantalum Silicone oil Silicone oil Silicone oil Silicone oil Silicone oil Inert fluid Inert fluid Inert fluid Inert fluid Inert fluid S K M V T A F C Y D Process flanges/adapters material and connection (wetted parts) - 9th character 1 AISI 316 L ss (Horizontal connection) /4in NPT-f direct (7/16in UNF U.S. drilling) 1 /4in NPT-f direct (DIN 19213) AISI 316 L ss (Horizontal connection) 1 /2in NPT-f through adapter (7/16in UNF U.S. drilling) AISI 316 L ss (Horizontal connection) 1 Hastelloy C276TM (Horizontal connection) /4in NPT-f direct (7/16in UNF U.S. drilling) 1 /4in NPT-f direct (DIN 19213) Hastelloy C276TM (Horizontal connection) 1 /2in NPT-f through adapter (7/16in UNF U.S. drilling) Hastelloy C276TM (Horizontal connection) 1 Monel 400TM (Horizontal connection) /4in NPT-f direct (7/16in UNF U.S. drilling) 1 /4in NPT-f direct (DIN 19213) Monel 400TM (Horizontal connection) 1 Monel 400TM (Horizontal connection) /2in NPT-f through adapter (7/16in UNF U.S. drilling) Kynar (PVDF) (Horizontal connection) (MWP=1MPa,10bar) 1/4in NPT-f direct (7/16in UNF U.S. drilling) NACE NACE NACE NACE NACE NACE NACE NACE NACE A C B D F E G L H P Bolts/Gasket (wetted parts) - 10th character Stainless steel (NACE) Stainless steel (NACE) Stainless steel (NACE) Stainless steel VitonTM PTFE (MWP 10MPa) EPDM Perbunan (Note 3) NACE NACE NACE 3 4 5 6 Housing material and electrical connection - 11th character Aluminium alloy (Barrel version) Aluminium alloy (Barrel version) Aluminium alloy (Barrel version) Aluminium alloy (Barrel version) AISI 316 L ss (Barrel version) AISI 316 L ss (Barrel version) Aluminium alloy (DIN version) Aluminium alloy (DIN version) Aluminium alloy (DIN version) 1 /2in NPT M20 x 1.5 (CM 20) Harting Han 8U connector Fieldbus connector 1 /2in NPT M20 x 1.5 (CM20) M20 x 1.5 (CM 20) Harting Han 8U connector Fieldbus connector (Not available FM, CSA) (Note 4) (Not available ATEX EExd, FM, CSA) (Note 4) (Not available ATEX EExd, FM, CSA) (Not available FM, CSA) (Not available FM, CSA) (Note 4) (Not available ATEX EExd, FM, CSA) (Note 4) (Not available ATEX EExd, FM, CSA) A B E G S T J K W Output/Additional options - 12th character HART digital communication and 4 to 20mA HART digital communication and 4 to 20mA PROFIBUS PA PROFIBUS PA FOUNDATION Fieldbus FOUNDATION Fieldbus No additional options Options requested (to be ordered by "Additional ordering code") No additional options Options requested (to be ordered by "Additional ordering code") No additional options Options requested (to be ordered by "Additional ordering code") (Notes 5, 6) (Note 5) (Notes 5, 6) (Note 6) (Notes 5, 6) (Note 6) H 1 P 2 F 3 13 2600T Pressure Transmitters Model 265JS SS/265JS_3 ADDITIONAL ORDERING INFORMATION for model 265JS Add one or more 2-digit code(s) after the basic ordering information to select all required options XX XX XX XX XX XX XX XX XX XX XX XX Drain/vent valve (material and position) (wetted parts) AISI 316 L ss on process axis (Note 7) AISI 316 L ss on flange side top (Note 7) AISI 316 L ss on flange side bottom (Note 7) Hastelloy C276TM on process axis (Note 8) Hastelloy C276TM on flange side top (Note 8) Hastelloy C276TM on flange side bottom (Note 8) Monel 400TM on process axis (Note 9) Monel 400TM on flange side top (Note 9) Monel 400TM on flange side bottom (Note 9) Electrical certification ATEX Group II Category 1/2 GD - Intrinsic Safety EEx ia ATEX Group II Category 1/2 G - Flameproof EEx d ATEX Group II Category 3 GD - Type of protection "N" EEx nL energy limited Factory Mutual (FM) - Intrinsically Safe Factory Mutual (FM) - Explosion Proof (only with 1/2in NPT electrical connection and stainless steel Canadian Standard Association - Intrinsically Safe (pending) Canadian Standard Association - Explosion Proof Integral LCD Digital LCD integral display Backlit digital LCD integral display Mounting bracket (shape and material) For pipe mounting AISI 316 L ss For wall mounting AISI 316 L ss Surge Surge/Transient Protector (Note 10) NACE NACE NACE NACE NACE NACE NACE NACE NACE label) V1 V2 V3 V4 V5 V6 V7 V8 V9 E1 E2 E3 EA EB ED EE Operating manual German L1 L2 B2 B4 S1 M1 Labels & tag language German in stainless steel (not available with DIN Electronic Housing code J, K, W) German and English plastic (not suitable for Factory Mutual - Explosion Proof) Additional tag plate In stainless steel Preparation procedure Oxygen service cleaning (only available with inert fill - Pmax=12MPa/120bar/1740psi; Tmax=60 C/140 F) Hydrogen service preparation T1 TA I1 P1 P2 Certificates Inspection certificate EN 10204-3.1.B of calibration Inspection certificate EN 10204-3.1.B of the cleanliness stage according to DIN 25410 Inspection certificate EN 10204-3.1.B of helium leakage test of the sensor module Inspection certificate EN 10204-3.1.B of the pressure test Certificate of compliance with the order EN 10204-2.1 of instrument design C1 C3 C4 C5 C6 Material traceability Certificate of compliance with the order EN 10204-2.1 of process wetted parts Inspection certificate EN 10204-3.1.B of process wetted parts (small parts with certificate of compliance EN 10204) Test report EN 10204-2.2 of the pressure bearing and process wetted parts H1 H3 H4 Connector Fieldbus 7/8 (without mating female plug) Fieldbus M12x1 (without mating female plug) Harting Han 8U - straight entry Harting Han 8U - angle entry 14 (Notes 6, 11) (Notes 6, 11) (Notes 5, 11) (Notes 5, 12) U1 U2 U3 U4 2600T Pressure Transmitters Model 265JS Note 1: Not available with sensor code C, F, L, N, R Note 2: Not available with sensor code A Note 3: Suitable for oxygen service Note 4: Select type in additional ordering code Note 5: Not available with Electronic Housing code G and W Note 6: Not available with Electronic Housing code E and K Note 7: Not available with Process flanges/adapters code D, E, F, G, H, L, P Note 8: Not available with Process flanges/adapters code A, B, C, G, H, L, P Note 9: Not available with Process flanges/adapters code A, B, C, D, E, F, P SS/265JS_3 Note 10: Not available with ATEX-EEx nL (code E3) or PROFIBUS PA / FOUNDATION Fieldbus (code 2 or 3) with Intrinsic Safety EEx i (code E1) or FM-Intrinsically Safe (code EA). Note 11: Not available with Electronic housing code T, S, A, B, J Note 12: Not available with Electronic housing code T, S, A, B, J, K TM Hastelloy is a Cabot Corporation trademark TM Monel is an International Nickel Co. trademark TM Viton is a Dupont de Nemour trademark Standard delivery items (can be differently specified by additional ordering code) - Adapters supplied loose - Plug on axis (no drain/vent valves) - General purpose (no Ex design) - No meter/display, no mounting bracket, no surge protection - English manual and labels (stainless steel nameplate for Barrel housing code A, B, E, G, S, T; plastic nameplate for DIN housing code J, K, W) - Configuration with kPa and deg. C units - No test, inspection or material traceability certificates THE SELECTION OF SUITABLE WETTED PARTS AND FILLING FLUID FOR COMPATIBILITY WITH THE PROCESS MEDIA IS A CUSTOMER'S RESPONSIBILITY, IF NOT OTHERWISE NOTIFIED BEFORE MANUFACTURING. 15 2600T Pressure Transmitters Model 265JS SS/265JS_3 The Company's policy is one of continuous product improvement and the right is reserved to modify the information contained herein without notice. ABB has Sales & Customer Support expertise in over 100 countries worldwide Printed in Italy (01.04) www.abb.com/instrumentation SS/265JS_3 (c) ABB 2004 ABB Ltd Howard Road, St. Neots Cambridgeshire, PE19 3EU UK Tel: +44(0)1480 475321 Fax: +44(0)1480 217948 ABB Inc. 125 E. County Line Road Warminster, PA 18974 USA Tel: +1 215 674 6000 Fax: +1 215 674 7183 ABB Automation Products GmbH Schillerstrasse 72 D-32425 Minden Germany Tel: +49 (0) 551 905 534 Fax: +49 (0) 551 905 555