4 MHz 3.7 dB/100m 65.3 dB 63.3 dB 61.6 dB 59.6 dB 55.7 dB 52.7 dB 23 dB 100 ± 12 Ohm 100 ± 15
8 MHz 5.3 dB/100m 60.3 dB 58.8 dB 55.5 dB 53.5 dB 49.7 dB 46.7 dB 24.5 dB 100 ± 12 Ohm 100 ± 15
10 MHz 5.9 dB/100m 59.3 dB 57.3 dB 53.4 dB 51.4 dB 47.8 dB 44.8 dB 25 dB 100 ± 12 Ohm 100 ± 15
16 MHz 7.5 dB/100m 56.3 dB 54.3 dB 48.7 dB 46.7 dB 43.7 dB 40.7 dB 25 dB 100 ± 12 Ohm 100 ± 8
20 MHz 8.4 dB/100m 54.8 dB 52.8 dB 46.4 dB 44.4 dB 41.7 dB 38.7 dB 25 dB 100 ± 12 Ohm 100 ± 8
25 MHz 9.5 dB/100m 53.4 dB 51.4 dB 43.9 dB 41.9 dB 39.8 dB 36.8 dB 24.3 dB 100 ± 15 Ohm 100 ± 8
31.25 MHz 10.6 dB/100m 51.9 dB 49.9 dB 41.2 dB 39.2 dB 37.9 dB 34.9 dB 23.6 dB 100 ± 15 Ohm 100 ± 8
62.5 MHz 15.4 dB/100m 47.4 dB 45.4 dB 32 dB 30 dB 31.8 dB 28.8 dB 21.5 dB 100 ± 15 Ohm 100 ± 8
100 MHz 19.8 dB/100m 44.3 dB 42.3 dB 24.5 dB 22.5 dB 27.8 dB 24.8 dB 21 dB 100 ± 15 Ohm
155 MHz 25.1 dB/100m 41.5 dB 39.5 dB 16.3 dB 14.3 dB 23.9 dB 20.9 dB 21 dB 100 ± 15 Ohm
200 MHz 29 dB/100m 39.9 dB 37.9 dB 10.8 dB 10 dB 21.7 dB 18.7 dB 21 dB 100 ± 15 Ohm
250 MHz 32.8 dB/100m 38.3 dB 36.3 dB 5.5 dB 3.5 dB 19.8 dB 16.8 dB 18 dB 100 ± 20 Ohm
300 MHz 35.2 dB/100m 37.2 dB 34.2 dB 0.7 dB 0 dB 18.2 dB 15.2 dB 18 dB 100 ± 20 Ohm
310 MHz 37.1 dB/100m 36.9 dB 34.9 dB 0 dB 17.9 dB 14.9 dB 18 dB 100 ± 20 Ohm
350 MHz 39.8 dB/100m 36.2 dB 34.2 dB 16.9 dB 13.9 dB 17 dB 100 ± 22 Ohm
400 MHz 43 dB/100m 35.3 dB 33.3 dB 15.7 dB 12.7 dB 14 dB 100 ± 32 Ohm
500 MHz 49 dB/100m 33.8 dB 31.8 dB 13.8 dB 10.8 dB 14 dB 100 ± 32 Ohm
Voltage
UL Voltage Rating Non-UL Voltage Rating
300 V (CM) 300 V (CMG-HL)
Mechanical Characteristics
Temperature
UL Rating. Operating Installation Storage
60°C -40°C To +75°C -25°C To +75°C -40°C To +85°C
Bend Radius
Stationary Min.
8.25 in
Max. Pull Tension: 200 lbs
Bulk Cable Weight: 154 lbs/1000ft
Standards and Compliance
Environmental Suitability: Indoor (Not Riser or Plenum), Indoor, Outdoor, Sunlight Resistance, Oil Resistance
Flammability / Fire Resistance: UL 1685 (UL Loading), FT4, FT4, IEC 60332-1-2
NEC / UL Compliance: 800, CM
CEC / C(UL) Compliance: CMG, HL, CMG-HL
IEEE Compliance: IEEE 802.3bt Type 1, Type 2, Type 3, Type 4
Data Category: Category 6
TIA/EIA Compliance: ANSI/TIA-568.2-D Category 6
CPR Euroclass: Eca
European Directive
Compliance: EU Directive 2015/863/EU, EU Directive 2011/65/EU (ROHS II), EU Directive 2012/19/EU (WEEE), REACH: 2020-01-16
APAC Compliance: China RoHS II (GB/T 26572-2011)
Part Number
Variants
Item # Color Putup Type Length UPC
121872A 0101000 Black Reel 1,000 ft 612825109037
121872A J221000 Blue, Strong Reel 1,000 ft 612825109013
121872A 0081000 Gray Reel 1,000 ft 612825109020
Product Notes
Notes: US Patent #'s 5606151; 5734126; 5821467 **Values above 350 MHz are information only. Operating temperatures are subject to length de-rating. Cable passes -40C Cold
Bend per UL 1581.
History
Update and Revision: Revision Number: 0.383 Revision Date: 09-30-2020