CPA, CPD Series Data Sheet
200 – 550 Watt CompactPCI® AC-DC and DC-DC Converters
BCD20005-G Rev. AF, 18-Aug-10 Page 17 of 19 www.power-one.com
Table 12: Pin allocation of the front connector
Pin1
L ength
2
Signal Description Pin1
Length
2
Signal Description
name name
1 – 4 B Vo1 Output 1 32 C n.c. Do not connect
5 – 12 B RTN Return (Vo1 and Vo2) 33 C Vo2SENSE Vo2 remote sense
13 – 18 B Vo2 Output 2 34 C SRTN Sense return
19 B RTN Return (Vo3) 35 C Vo1SHARE Vo1 current share
20 B Vo3 Output 3 36 C Vo3SENSE Vo3 remote sense
21 C Vo4 Output 4 37 C n.c. Do not connect
22 C RTN Return 38 C DEG# Degrade signal
23 C Reserved Reserved 39 C INH# Inhibit
24 C RTN Return (Vo4) 40 C n.c. Do not connect
25 C n.c. Do not connect 41 C Vo2SHARE Vo2 current share
26 C Reserved Reserved 42 C FAL# Fail signal
27 D EN# Enable 43 C n.c. Do not connect
28 C n.c. Do not connect 44 C Vo3SHARE Vo3 current share
29 C n.c. Do not connect 45 A
3
CGND Chassis ground
30 C Vo1SENSE Vo1 remote sense 46 A +DCIN4 ACN5Pos. DC input4 Neutral line5
31 C n.c. Do not connect 47 A – DCIN4 ACL5Neg. DC input4 Line input (phase)5
1Pin numbers shown are for the female backplane connector
2A = very long pins, B = long pins, C = short pins, D = very short pins.
3Pin 45 of the female connector is leading, ensuring that chassis ground makes contact first.
4CPD models (DC input)
5CPA models (AC input )
Safety and Installation Instructions
Connector Pin Allocation
The connector pin allocation table defines the electrical
potentials and the physical pin positions on the Positronic
connector. Pin no. 45 (protective earth) is a leading pin,
ensuring that it makes contact with the female connector
first.
Installation Instructions
These converters are components, intended exclusively for
installation within other equipment by an industrial
assembly process or by a professionally, competent
person. Installation must strictly follow the national safety
regulations in respect of the enclosure, mounting, creepage
distances, clearance, casualty markings, and segregation
requirements of the end-use application.
Connection to the system shall be made via the mating
female connector (see fig. 16). Other installation methods
may not meet the safety requirements. Check for hazardous
voltage, before altering any connections.
The converters are provided with a leading pin no. 45, which
is reliably connected to the case. For safety reasons it is
essential to connect this pin to the protective earth of the
supply system.
The input –DCIN or ACL (pin no. 47) is internally fused; see
Input Fuse and Protection. This fuse is designed to break an
overcurrent in case of a malfunction of the converter and is
not customer-accessible.
External fuses in the wiring to one or both input lines (pin 47
and/or pin 46) may be necessary to ensure compliance with
local requirements. A built-in second fuse in the neutral line
(pin 47) is available as option F for CPA500 models.
A second fuse in the wiring to the neutral line or option F may
be needed if:
• Local requirements demand an individual fuse in each
source line
• Neutral and earth impedance is high or undefined
• Phase and neutral of the mains are not defined or cannot
be assigned to the corresponding terminals.
Caution:
Installation must strictly follow the national safety regulations.
Models with option F: Caution! Double-pole/neutral fusing.
Do not open the converters, or the warranty will be
invalidated!
Important: If the inhibit function is not used, pin 39 (i) should
be left open-circuit to enable the outputs. Enable Pin 27 (EN#)
should be connected to pin 22 (RTN) to enable the outputs.
Fig. 18
Pinout of the front connector
10087a
2468 101214161820
135791113 15 17 19
45 47
46
23 26 29 32 35 38 41 44
22 25 28 31 34 37 40 43
21 24 27 30 33 36 39 42
Connector: Positronic PCIH47M400A1 or similar
Mating female connector: Positroni c PCIH47F300A1 or similar