PolySwitch Resettable Devices Telecommunications & Networking Devices
213
12
This family of telecommunication and networking
devices was initially designed to meet the growing
demand for resettable overcurrent protection. These
product families help provide protection against
damage caused by power cross and power induction
surges as defined in ITU, Telcordia GR1089, and
UL60950. Available in chip, surface-mount, and radial-
leaded configurations, TE’s PolySwitch devices help
improve the reliability of customer premise and network
equipment world wide.
Many product choices give engineers more design
flexibility
Compatible with high volume electronics assembly
Assist in meeting regulatory equipment requirements
Improved line balance
Applicable for legacy POTS and modern digital
communications equipment
RoHS compliant
Resettable overcurrent protection
Surface-mount, radial-leaded, and chip form factors
Fast time-to-trip
Agency recognition: UL, CSA, TÜV
Resistance sorted and matched devices available
Low parasitic capacitance/flat impedance with
frequency
Modems
Phone sets
Fax machines
Phone wall outlets
Alarm systems
PolySwitch Resettable Devices
Telecommunications & Networking Devices
Benefits Features
Applications
PBX systems
MDF modules
Analog and digital line cards
T1/E1 equipment
xDSL modems and splitters
Powered ethernet systems
VoIP (Voice over Internet Protocol) equipment
LAN, WAN equipment
Customer premise equipment
Access network hardware
NOT the LATEST
REVISION
OBSOLETE
214 RoHS Compliant, ELV Compliant
12
Application Guide for Telecommunications and Networking Devices*
To use this guide, follow the steps below:
1. Select your equipment type from the guide below.
2. Select the type of protection depending on the agency and regional specifications in the second column.
3. Select the form factor for your application.
4. Use the Agency Specification/ PolySwitch Device Selection Guide on the next page to select a specific part number for each application
based on the agency requirements.
5. Parts with fast time-to-trip or low resistance are available. Please consult aTE Circuit Protection representative.
Customer Premises equipment North America TRF600-150 TS600-170F
IT equipment TIA-968-A, TR600-150F-EX TS600-200F
Analog modems, V.90 modems, UL 60950, TRF600-160 TSM600-250F
ISDN modems, xDSL modems, GR1089 Port Type 3TRF600-400 TSM600-400F
ADSL splitters, phone sets, fax machines, Europe/Asia/ TRF250-120 TS250-130F
answering machines, caller ID, internet South America TRF250-120T TSV250-130F
appliances, PBX systems, POS terminals, ITU K.21 TRF250-145
wall plugs TRF250-183
TRF250-184
Access network equipment (†) North America TRF600-160 TS600-170F
Remote terminals, line repeaters, GR1089 Port Type 5TRF600-400 TS600-200F
multiplexers, cross-connects, TS600-400F
WAN equipment TSM600-250F
TSM600-400F
FT600-1250**
Europe/Asia/ TRF250-120 TS250-130F
South America TRF250-120T TSV250-130F
ITU K.45 TRF250-145
TRF250-183
TRF250-184
Central office switching equipment (†) North America TRF600-160 TS600-170F
Analog/POTS linecards, ISDN linecards, GR1089 Port Type 1TRF600-400 TS600-200F
xDSL modems, ADSL/VDSL splitters, TS600-400F
T1/E1 linecards, multiplexers, TSM600-250F
CSU/DSU, servers TSM600-400F
FT600-1250**
Europe/Asia/ TRF250-120 TS250-130F TCF250-180
South America TRF250-120T TSV250-130F
ITU K.20 TRF250-145
TRF250-183
TRF250-184
Primary protection modules (†) North America TRF250-183
MDF modules, Network Interface Telcordia GR-974 TRF250-184
Devices (NID) Europe/Asia/ TRF250-055UT TSL250-080F TCF250-100T
South America TRF250-080U TS250-130F TCF250-120T
ITU K.20 TRF250-110U TSV250-130F TCF250-145T
TRF250-120 TCF250-180
TRF250-120T
TRF250-145
TRF250-183
TRF250-184
Short-haul/intrabuilding communications North America TRF250-080U TSL250-080F
equipment (†) GR1089 Port Type 2TRF250-120 TS250-130F
LAN equipment, VoIP cards, cable GR1089 Port Type 4TRF250-120T TSV250-130F
telephony NIUs, wireless local loop TRF250-145
handsets TRF250-183
TRF250-184
Europe/Asia/ TRF250-120 TS250-130F
South America TRF250-120T TSV250-130F
ITU K.21 TRF250-145
TRF250-183
TRF250-184
Application
Region/
Specification
Form Factor
Radial-leaded Surface-mount Chip
Overcurrent Protection
PolySwitch Resettable Devices Telecommunications & Networking Devices
215
RoHS Compliant, ELV Compliant
12
Protection Application Guide for Telecommunications and Networking Devices*
Cont’d
LAN intrabuilding power cross protection North America TRF250-080U TSL250-080F
LAN equipment, VoIP cards, IP phones GR1089 PortType 4TRF250-120 TS250-130F
TRF250-120T TSV250-130F
TRF250-145
TRF250-183
TRF250-184
IEEE 802.3AF/AT Power over decaSMDC050F/60-2††
Ethernet protection
Powered Ethernet switches and terminals,
IP phones, wireless LAN base stations,
microcellular base stations, VoIP cards
Cable telephony powering system
Power passing taps BBRF550‡‡
Agency Specification/Selection Guide for Telecommunications and Networking Devices
Use the guide below to select the PolySwitch devices which are typically used in your application.The following pages contain the
specifications for the part numbers recommended below. PolySwitch devices assist telecommunication equipment in meeting the applicable
protection requirements of these industry specifications. Refer to individual agency specifications for test procedures and circuit schematics.
Users should independently evaluate the suitability of, and test each product for their application.
Family Product* Lightning Power Cross/Contact/Induction
TCF250 TCF250-100T ITU K.20 1.0kV 10/700µs PRCYD/T694
GR-1089 Port Types 2 & 4 1st Level ITU K.20/21/45 0.2A2s
ITU K.20/21/45 1A2s
GR-1089 Port Type 4 120VAC, 25Asc
TCF250-120T ITU K.20/21/45 1.5kV 10/700µs ITU K.20/21/45 230VAC, 10
TCF250-145T ITU K.20/21/45 4.0kV 10/700µsITU K.20/21/45 0.2A2s
TCF250-180 GR-1089 Port Types 2 & 4 1st Level ITU K.20/21/45 1A2s
ITU K.20/21/45 10A2s
GR-1089 Port Type 4 120VAC, 25Asc
* Applies to all products which share the same prefix.
Tested with 230V gas discharge tube primary protector.
Application
Region/
Specification
Form Factor
Radial-leaded Surface-mount Chip
Overcurrent Protection
* This list is not exhaustive. TE Circuit Protection welcomes our customers input for additional application ideas for PolySwitch resettable devices.
For improved line balance in these applications, resistance-matched parts are recommended.
May require additional impedance or coordination with primary protector.
** FT600-1250 are surface mount telecom fuse devices. FT600-0500 and FT600-2000 reference also available. See telecom fuses section.
†† For details on decaSMDC050F/60-2, see surface-mount devices section.
‡‡ For details on BBRF series, see radial-leaded devices section.
216 RoHS Compliant, ELV Compliant
12
Agency Specification/Selection Guide for Telecommunications and Networking Devices
Cont’d
Family Product* Lightning Power Cross/Contact/Induction
TRF250 TRF250-055UT ITU K.20 1.0kV 10/700µs ITU K.20 230VAC, 10
TRF250-080U ITU K.20 1.0kV 10/700µs ITU K.20 230VAC, 10
GR-1089 Port Types 2 & 4 1st Level ITU K.20 0.2A2s
ITU K.20 1A2s
GR-1089 Port Type 4 120VAC, 25Asc
TRF250-110U ITU K.20/21/45 1.5kV 10/700µs ITU K.20/21/45 230VAC, 10
TRF250-120 ITU K.20/21/45 4.0kV 10/700µsITU K.20/21/45 0.2A2s
TRF250-120T GR-1089 PortTypes 2 & 4 1st Level ITU K.20/21/45 1A2s
TRF250-120U ITU K.20/21/45 10A2s
TRF250-120UT GR-1089 PortType 4 120VAC, 25Asc
TRF250-145
TRF250-145U
TRF250-183
TRF250-184 ITU K.20/21/45 1.5kV 10/700µs ITU K.20/21/45 230VAC, 10**
ITU K.20/21/45 4.0kV 10/700µsITU K.20/21/45 0.2A2s
GR-1089 Port Types 2 & 4 1st Level ITU K.20/21/45 1A2s
ITU K.20/21/45 10A2s
GR-1089 Port Type 4 120VAC, 25Asc
TS250/TSV250 TSV250-130F ITU K.20/21/45 1.5kV 10/700µs ITU K.20/21/45 230VAC, 10
TS250-130F ITU K.20/21/45 4.0kV 10/700µsITU K.20/21/45 0.2A2s
GR-1089 Port Types 2 & 4 1st Level ITU K.20/21/45 1A2s
ITU K.20/21/45 10A2s
GR-1089 Port Type 4 120VAC, 25Asc
TS250-130F-RB ITU K.20/21/45 1.5kV 10/700µs ITU K.20/21/45 230VAC, 10
ITU K.20/21/45 4.0kV 10/700µsITU K.20/21/45 0.2A2s
GR-1089 Port Types 2 & 4 1st Level ITU K.20/21/45 1A2s
ITU K.20/21/45 10A2s
GR-1089 Port Type 4 120VAC, 25Asc
TSL250 TSL250-080F GR-1089 PortTypes 2 & 4 1st Level GR-1089 PortType 4 120VAC, 25Asc
ITU K.20 1.0kV 10/700µs ITU K.20/21/45 230VAC, 10
ITU K.20/21/45 0.2A2s
ITU K.20/21/45 1A2s
TRF600 TRF600-150 TIA-968-A Types A & B UL60950 600VAC, 40Asc
TR600-150F-EX GR-1089 Port Types 1, 3, & 5 1st & 2nd Level†† UL60950 600VAC, 40Asc
TR600-150F-EX-RA-B-0.5 GR-1089 Port Types 1, 3, & 5 1st & 2nd Level†† UL60950 600VAC, 40Asc
TRF600-160 GR-1089 Port Types 1, 3, & 5 1st & 2nd Level†† Telcordia GR-1089 600VAC, 60Asc
TRF600-400 GR-1089 PortTypes 1, 3, & 5 1st & 2nd Level Telcordia GR-1089 600VAC, 60Asc
TS600 TS600-170F TIA-968-A Types A & B UL60950 600VAC, 40Asc
TS600-200F-RA GR-1089 Port Types 1, 3, & 5 1st & 2nd Level†† Telcordia GR-1089 600VAC, 60Asc
TS600-400F
TSM600 TSM600-250F TIA-968-A Types A & B UL60950 600VAC, 40Asc
TSM600-250F-RA GR-1089 Port Types 1, 3, & 5 1st & 2nd Level†† Telcordia GR-1089 600VAC, 60Asc
TSM600-400F TIA-968-A Types A & B UL60950 600VAC, 40Asc
GR-1089 Port Types 1, 3, & 5 1st & 2nd Level Telcordia GR-1089 600VAC, 60Asc
FT600‡‡ FT600-0500 TIA-968-A - Types A & B UL60950 600VAC, 40Asc
FT600-1250
FT600-2000 GR-1089 Port Types 1, 3, & 5 1st & 2nd Level Telcordia GR-1089 600VAC, 60Asc
* Applies to all products which share the same prefix.
Tested with 230V gas discharge tube primary protector.
Tested with 350V gas discharge tube primary protector.
** See SCD for additional application fault ratings.
†† May require additional series resistor to help telecommunication equipment pass Surge 3 (1kV, 10/1000µs).
‡‡ See telecom fuses section.
PolySwitch Resettable Devices Telecommunications & Networking Devices
TS600
TCF250 TRF250 TS250 TSV250 TSL250 TSM600 TRF600
Voltage Rating (VAC)* 250 250 250 250 250 600 600
(Interrupt)
ITU ITU ITU ITU UL60950 UL60950
GR-1089 GR-1089 GR-1089 GR-1089 GR-1089 GR-1089 GR-1089
Specification Ports 2 & 4 Ports 2 & 4 Ports 2 & 4 Ports 2 & 4 Ports 2 & 4 Ports 1, 3, & 5 Ports 1, 3, & 5
Hold Current (A)
0.055 20.0——
0.080 17.0——8.0——
0.100 11.0———
0.110 7.0——
0.120 10.58.0——
0.130 ——9.05.5——
0.145 7.04.5——
0.150 ——8.0
0.160 ——6.0
0.170 ——11.0
0.183 1.3——
0.184 1.9——
0.200 ——8.5
0.250 ——3.5
0.400 ——1.21.2
217
RoHS Compliant, ELV Compliant
12
Voltage Ratings for Telecommunications and Networking Devices
For circuit protection telecommunications devices there are two applicable voltage ratings. These are VMAX Operating and
VMAX Interrupt. To help understand the nature of these two different voltage ratings, the following definitions are provided:
VMAX Operating : For telecommunications devices this is the voltage used to obtain component recognition under UL1434. Most circuit
protection devices are certified at 60V but can withstand higher VMAX Interrupt conditions as noted above.
See Table T3 for its VMAX Operating.
*VMAX Interrupt : Under specified conditions this is the highest voltage that can be applied to the device at the maximum current. Devices
have been designed to trip safely under higher power level cross conditions, as listed above, to assist equipment in
meeting the appropriate industry conditions.
Table T1 Product Series: Size, Current Rating, Voltage Rating, Typical Resistance for
Telecommunications and Networking Devices
218 RoHS Compliant, ELV Compliant
12
% of Rated Hold andTrip Current
Device’s Ambient Temperature (˚C)
200
150
100
50
0
-40 -20 0 20 40 60 80
A
A
B
B
Figure T1
A=TCF250-180
B=All other TCF, TRF,
TSx, TSM series devices
NEW
Maximum Ambient Temperature
Part Number -40°C -20°C 0°C 20°C 40°C 50°C 60°C 70°C 85°C
Chip* 250VAC
TCF250
TCF250-100T 0.155 0.138 0.119 0.100 0.083 0.073 0.064 0.055 0.042
TCF250-120T 0.186 0.165 0.143 0.120 0.099 0.088 0.077 0.066 0.050
TCF250-145T 0.225 0.199 0.172 0.145 0.119 0.106 0.093 0.080 0.060
TCF250-1800.269 0.240 0.211 0.180 0.153 0.138 0.123 0.109 0.087
Radial-leaded* 250VAC
TRF250
TRF250-055UT 0.085 0.076 0.065 0.055 0.045 0.041 0.035 0.030 0.023
TRF250-080U 0.124 0.110 0.095 0.080 0.066 0.059 0.051 0.044 0.033
TRF250-110U 0.171 0.151 0.131 0.110 0.091 0.081 0.071 0.061 0.046
TRF250-120 0.186 0.165 0.143 0.120 0.099 0.088 0.077 0.066 0.050
TRF250-145 0.225 0.199 0.172 0.145 0.119 0.106 0.093 0.080 0.060
TRF250-1830.284 0.251 0.217 0.183 0.149 0.133 0.117 0.101 0.075
TRF250-1840.286 0.252 0.218 0.184 0.150 0.134 0.118 0.102 0.075
Surface-mount* 250VAC
TS250/TSL250/TSV250
TSL250-080F 0.124 0.110 0.095 0.080 0.066 0.059 0.051 0.044 0.033
TS250-130F 0.208 0.182 0.156 0.130 0.104 0.091 0.078 0.065 0.045
TSV250-130F 0.208 0.182 0.156 0.130 0.104 0.091 0.078 0.065 0.045
Radial-leaded 600VAC
TRF600
TRF600-150 0.239 0.209 0.180 0.150 0.121 0.107 0.093 0.079 0.057
TR600-150F-EX 0.239 0.209 0.180 0.150 0.121 0.107 0.093 0.079 0.057
TR600-150F-EX-RA 0.239 0.209 0.180 0.150 0.121 0.107 0.093 0.079 0.057
TRF600-160 0.255 0.223 0.192 0.160 0.129 0.114 0.099 0.084 0.061
TRF600-400 0.640 0.560 0.480 0.400 0.320 0.270 0.230 0.190 0.130
Surface-mount 600VAC
TS600/TSM600
TS600-170F 0.264 0.230 0.200 0.170 0.140 0.125 0.109 0.094 0.070
TS600-200F-RA-B-0.5 0.310 0.275 0.238 0.200 0.165 0.147 0.128 0.110 0.083
TS600-400F 0.640 0.560 0.480 0.400 0.320 0.270 0.230 0.190 0.130
TSM600-250F 0.400 0.350 0.300 0.250 0.198 0.170 0.140 0.117 0.083
TSM600-250F-RA 0.400 0.350 0.300 0.250 0.198 0.170 0.140 0.117 0.083
TSM600-400F 0.640 0.560 0.480 0.400 0.320 0.270 0.230 0.190 0.130
* 250VAC interrupt products are designed to help equipment pass ITU K.20, K.21, & K.45 recommendations andTelcordia GR-1089 PortType 2 & 4 requirements.
600VAC interrupt products are designed to help equipment pass UL60950,TIA-968-A and GR1089 Port Type 1, 3 & 5 requirements.
Product is not currently available in a resistance matched or sorted option.
NEW
NEW
Table T2 Thermal Derating for Telecommunications and Networking Devices
[Hold Current (A) at Ambient Temperature (°C)]
Figure T1 Thermal Derating [Hold Current (A) at Ambient Temperature (°C)]
PolySwitch Resettable Devices Telecommunications & Networking Devices
219
RoHS Compliant, ELV Compliant
12
Chip* 250VAC
TCF250
TCF250-100T 0.100 0.150 60 250 3.0 0.6 1.0 0.2 14.0 18.0 24.0
TCF250-120T 0.120 0.240 60 250 3.0 1.0 1.0 0.6 6.3 12.0 18.0
TCF250-145T 0.145 0.290 60 250 3.0 1.0 1.0 1.5 5.0 9.0 14.0
TCF250-1800.180 0.650 60 250 3.0 0.9 1.0 15.5 1.0 2.2 4.0
Radial-leaded* 250VAC
TRF250
TRF250-055UT 0.055 0.170 60 250 3.0 0.6 0.28 3.0 15.0 25.0 35.0
TRF250-080T 0.080 0.160 60 250 3.0 0.6 0.35 2.5 15.0 22.0 33.0
TRF250-080U 0.080 0.160 60 250 3.0 0.6 0.35 2.5 14.0 20.0 33.0
TRF250-110U 0.110 0.220 60 250 3.0 1.0 1.00 0.8 5.0 9.0 16.0
TRF250-120 0.120 0.240 60 250 3.0 1.0 1.00 1.5 4.0 8.0 16.0
TRF250-120T 0.120 0.240 60 250 3.0 1.0 0.35 0.7 7.0 12.0 16.0
TRF250-120T-RA 0.120 0.240 60 250 3.0 1.0 1.00 1.2 7.0 9.0 16.0
TRF250-120T-RC 0.130 0.260 60 250 3.0 1.0 1.00 1.5 5.4 7.5 14.0
TRF250-120T-RF 0.120 0.240 60 250 3.0 1.0 1.00 0.9 6.0 10.5 16.0
TRF250-120T-R1 0.120 0.240 60 250 3.0 1.0 1.00 1.0 6.0 9.0 16.0
TRF250-120T-R2 0.120 0.240 60 250 3.0 1.0 1.00 0.8 8.0 10.5 16.0
TRF250-120U 0.120 0.240 60 250 3.0 1.0 1.00 1.0 6.0 10.0 16.0
TRF250-120UT 0.120 0.240 60 250 3.0 1.0 1.00 0.7 7.0 12.0 16.0
TRF250-145 0.145 0.290 60 250 3.0 1.0 1.00 2.5 3.0 6.0 14.0
TRF250-145-RA 0.145 0.290 60 250 3.0 1.0 1.00 2.5 3.0 5.5 12.0
TRF250-145-RB 0.145 0.290 60 250 3.0 1.0 1.00 2.0 4.5 6.0 14.0
TRF250-145T 0.145 0.290 60 250 3.0 1.0 1.00 1.5 5.4 7.5 14.0
TRF250-145U 0.145 0.290 60 250 3.0 1.0 1.00 2.0 3.5 6.5 14.0
TRF250-1830.183 0.685 100 250 10.0 0.9 3.00 0.6 0.8 2.2 3.4
TRF250-1840.184 1.000 100 250 10.0 0.9 3.00 0.5 1.2 2.4 3.1
Surface-mount* 250VAC
TS250/TSL250/TSV250
TSL250-080F 0.080 0.240 80 250 3.0 1.2 1.0 0.8 5.0 11.0 20.0**
TS250-130F 0.130 0.260 60 250 3.0 1.1 1.0 0.9 6.5 12.0 20.0**
——60 600 1.0 ——
TS250-130F-RA 0.130 0.260 60 250 3.0 1.1 1.0 1.4 6.5 9.0 15.0**
——60 600 1.0 ——
TS250-130F-RB 0.130 0.260 60 250 3.0 1.1 1.0 0.7 9.0 12.0 20.0**
——60 600 1.0 ——
TS250-130F-RC 0.130 0.260 60 250 3.0 1.1 1.0 1.1 7.0 10.0 17.0**
——60 600 1.0 ——
TSV250-130F 0.130 0.260 60 250 3.0 1.5 1.0 2.0 4.0 7.0 12.0**
Radial-leaded 600VAC
TRF600
TRF600-150 0.150 0.300 250 600 3.0 1.0 1.0 1.4 6.0 10.0 17.0
TRF600-150-RB 0.130 0.260 250 600 3.0 1.0 1.0 1.0 9.0 12.0 22.0
TR600-150F-EX 0.150 0.300 250 600 3.0 1.4 1.0 5.0 6.0 12.0 22.0
TR600-150F-EX-RA-B-0.5 0.150 0.300 250 600 3.0 1.4 1.0 5.0 7.0 10.0 20.0
TRF600-160 0.160 0.320 250 600 3.0 1.7 1.0 7.5 4.0 10.0 18.0
TRF600-160-RA 0.160 0.320 250 600 3.0 1.7 1.0 9.5 4.0 7.0 16.0
TRF600-160-R1 0.160 0.320 250 600 3.0 1.7 1.0 9.0 4.0 8.0 17.0
TRF600-400 0.400 1.000 60 600 3.0 2.4 3.0 4.0 0.95 1.45 1.90
Part
Number
IH
(A)
IT
(A)
PD Typ
(W)
Typical Time-to-trip
(A) (s)
RMIN
()
R1MAX
()
RMAX
()
Operating
(VDC)
Interrupt
(VRMS)
IMAX*
Interrupt
(A)
VMAX
NEW
NEW
* 250VAC interrupt products are designed to help equipment pass ITU K.20, K.21, & K.45 recommendations andTelcordia GR-1089 PortType 2 & 4 requirements.
600VAC interrupt products are designed to help equipment pass UL60950,TIA-968-A and GR1089 Port Type 1, 3 & 5 requirements.
Product is not currently available in a resistance matched or sorted option.
** R1MAX measured 1 hour post-trip, or 24 hours post-reflow at 20°C.
NEW
Table T3 Electrical Characteristics for Telecommunications and Networking Devices
220 RoHS Compliant, ELV Compliant
12
Notes:
IH: Hold current: maximum current device will pass without interruption in 20°C still air.
IT: Trip current: minimum current that will switch the device from low resistance to high resistance in 20°C still air.
VMAX Operating : Maximum continuous voltage device can withstand without damage at rated current. This voltage is used for component recognition under UL1434.
VMAX Interrupt : Maximum voltage that can be safely placed across a device in its tripped state. Devices have been designed to trip safely under higher level power cross conditions
to assist equipment in meeting the appropriate ITU, UL60950, or GR1089 industry requirements.
IMAX Interrupt : Maximum fault current device can withstand without damage at rated operating voltage. This current is used for component recognition under UL1434.
Devices have been designed to trip safely under higher level power cross conditions to assist equipment in meeting the appropriate ITU, UL60950, or GR1089
industry requirements.
PD: Power dissipated from device when in the tripped state in 20°C still air.
RMIN : Minimum resistance of device as supplied at 20°C unless otherwise specified.
RMAX : Maximum resistance of device as supplied at 20°C unless otherwise specified.
R1MAX : Maximum resistance measured one hour post-trip or post-reflow at 20°C.
* 250VAC interrupt products are designed to help equipment pass ITU K.20, K.21, & K.45 recommendations andTelcordia GR-1089 PortType 2 & 4 requirements.
600VAC interrupt products are designed to help equipment pass UL60950,TIA-968-A and GR1089 Port Type 1, 3 & 5 requirements.
Surface-mount 600VAC
TS600/TSM600
TS600-170F 0.170 0.400 60 600 3.0 2.5 1.0 10.0 4.0 9.0 18.0
TS600-200F-RA-B-0.5 0.200 0.400 60 600 3.0 2.5 1.0 12.0 4.0 7.5 13.5
TS600-400F 0.400 1.000 60 600 3.0 2.0 3.0 5.0 0.5 1.5 2.0
TSM600-250F 0.250 0.860 250 600 3.0 2.0 3.0 0.8 1.0 3.5 7.0
TSM600-250F-RA 0.250 0.860 250 600 3.0 2.0 3.0 1.0 1.0 3.0 5.0
TSM600-400F 0.400 1.000 250 600 3.0 2.0 3.0 5.0 0.5 1.5 2.0
Part
Number
IH
(A)
IT
(A)
PD Typ
(W)
Typical Time-to-trip
(A) (s)
RMIN
()
R1MAX
()
RMAX
()
Operating
(VDC)
Interrupt
(VRMS)
IMAX*
Interrupt
(A)
VMAX
Warning :
Users should independently evaluate the suitability of and test each product selected for their own application.
Operation beyond the maximum ratings or improper use may result in device damage and possible electrical arcing and flame.
These devices are intended for protection against damage caused by occasional overcurrent or overtemperature fault conditions and should
not be used when repeated fault conditions or prolonged trip events are anticipated.
Contamination of the PPTC material with certain silicone-based oils or some aggressive solvents can adversely impact the performance of the devices.
Device performance can be impacted negatively if devices are handled in a manner inconsistent with recommended electronic, thermal, and
mechanical procedures for electronic components.
PPTC devices are not recommended for installation in applications where the device is constrained such that its PTC properties are inhibited,
for example in rigid potting materials or in rigid housings, which lack adequate clearance to accommodate device expansion.
Operation in circuits with a large inductance can generate a circuit voltage (Ldi/dt) above the rated voltage of the device.
C
B
D
A
E
Cto
LC
L
Figure T2
C
B
D
A
E
Cto
LC
L
Figure T3
B
AC
Figure T4
Table T3 Electrical Characteristics for Telecommunications and Networking Devices
Cont’d
Figure T2-T13 Dimension Figures for Telecommunications and Networking Devices
PolySwitch Resettable Devices Telecommunications & Networking Devices
221
RoHS Compliant, ELV Compliant
12
CB
E
G
E
A
D D
F
Figure T9
C
B
DE
A
Figure T5
B
D
F
A C
E
Figure T6
B
C
E
A
DD
Figure T7
Figure T8
D
B
AC
E
Cto
LC
L
Figure T10
D
B
AC
E
Cto
LC
L
Figure T11
D
B
C
A
E
Cto
LC
L
Figure T13
AC
E
Cto
LC
L
D
B
Figure T12
Figure T2-T13 Dimension Figures for Telecommunications and Networking Devices
Cont’d
222 RoHS Compliant, ELV Compliant
12
TCF
250V*
TCF250-100T 4.6 4.9 4.6 4.9 2.0 2.3 —— —— T4 0.24
(0.18) (0.19) (0.18) (0.19) (0.08) (0.09)
TCF250-120T 5.4 5.6 5.4 5.6 2.0 2.3 —— —— T4 0.28
(0.21) (0.22) (0.21) (0.22) (0.08) (0.09)
TCF250-145T 5.4 5.6 5.4 5.6 2.0 2.5 —— —— T4 0.28
(0.21) (0.22) (0.21) (0.22) (0.08) (0.10)
TCF250-180 6.9 7.1 6.9 7.1 1.3 1.6 —— —— T4 0.35
(0.27) (0.28) (0.27) (0.28) (0.05) (0.06)
TRF250
250V*
TRF250-055UT 4.8 9.3 3.8 4.7 5.0—— T2 0.13
(0.19) (0.37) (0.15) (0.19) (0.20)
TRF250-080T 5.8 9.9 4.6 4.7 5.0—— T2 0.28
(0.23) (0.39) (0.18) (0.19) (0.20)
TRF250-080U 4.8 9.3 3.8 4.7 5.0—— T11 0.13
(0.19) (0.37) (0.15) (0.19) (0.20)
TRF250-110U 5.3 9.4 3.8 4.7 5.0——T11 0.13
(0.21) (0.37) (0.15) (0.19) (0.20)
TRF250-120 6.5 11.0 4.6 4.7 5.0—— T3 0.38
(0.26) (0.43) (0.18) (0.19) (0.20)
TRF250-120U 6.0 10.0 3.8 4.7 5.0——T10 0.19
(0.24) (0.39) (0.15) (0.19) (0.20)
TRF250-145 6.5 11.0 4.6 4.7 5.0—— T3 0.38
(0.26) (0.43) (0.18) (0.19) (0.20)
TRF250-145U 6.0 10.0 3.8 4.7 5.0——T10 0.19
(0.24) (0.39) (0.15) (0.19) (0.20)
TRF250-183 7.5 10.5 4.1 4.7 5.0—— T2 0.30
(0.29) (0.41) (0.16) (0.19) (0.20)
TRF250-184 7.7 10.5 4.6 4.7 5.0——T12 0.32
(0.30) (0.41) (0.18) (0.19) (0.20)
TS250/TSL250/TSV250
250V*
TSL250-080F 6.7 7.9 2.7 3.7 4.8 5.3 0.2 0.4 2.5 3.1 —— T7 2.80
(0.27) (0.31) (0.11) (0.15) (0.19) (0.21) (0.01) (0.02) (0.10) (0.12)
TS250-130F 8.5 9.4 3.4 7.4 0.3 3.8—— T5 3.60
(0.34) (0.37) (0.14) (0.29) (0.01) (0.15)
TSV250-130F 6.1 6.9 3.2 0.56 ——1.9 1.6 2.3 —— T6 2.80
(0.24) (0.27) (0.13) (0.02) (0.08) (0.07) (0.09)
TRF600
600V
TRF600-150 9.0 12.5 4.6 4.7 5.0 ——9.0 —— T3 0.37
(0.35) (0.49) (0.18) (0.19) (0.20) (0.35)
TR600-150F-EX 13.5 12.6 6.0 4.7 5.0 —— T3 0.80
(0.53) (0.50) (0.18) (0.19) (0.20)
TR600-150F-EX-RA-B-0.5 13.5 12.6 6.0 4.7 5.0 —— T3 0.80
(0.53) (0.50) (0.18) (0.19) (0.20)
TRF600-160 16.0 12.6 6.0 4.7 5.0——10.0 —— T3 0.90
(0.63) (0.50) (0.24) (0.19) (0.20) (0.39)
TRF600-400 14.8 13.1 4.6 4.7 5.0——T13 0.85
(0.58) (0.52) (0.18) (0.19) (0.20)
Part Number
A
Min. Max. Figure
NEW
* 250VAC interrupt products are designed to help equipment pass ITU K.20, K.21, & K.45 recommendations andTelcordia GR-1089 PortType 2 & 4 requirements.
600VAC interrupt products are designed to help equipment pass UL60950,TIA-968-A and GR1089 Port Type 1, 3 & 5 requirements.
Indicates dimension is typical, not minimum.
NEW
NEW
Table T4 Dimensions & Weights for Telecommunications and Networking Devices
Device Mass (g)
(Only for reference)
B
Min. Max.
C
Min. Max.
D
Min. Max.
E
Min. Max.
F
Min. Max.
G
Min. Max.
Dimensions in Millimeters (Inches)
PolySwitch Resettable Devices Telecommunications & Networking Devices
223
RoHS Compliant, ELV Compliant
12
Time-to-trip (s)
Fault Current (A)
100
10
1
0.10
0.01
0.00 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 2.20 2.40 2.60 2.80 3.00
A
A
B
B
C
D
C
D
Figure T14
TCF250
A= TCF250-180
B= TCF250-145T
C= TCF250-120T
D = TCF250-100T
Time-to-trip (s)
Fault Current (A)
1000
100
10
1
0.10
0.01
0.00 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 2.20 2.40 2.60 2.80 3.00
A
A
B
C
D
E
B
C
D
E
Figure T15
TRF250
A=TRF250-180/183/184
B=TRF250-145/145U
C=TRF250-120/120U
D=TRF250-110U/120UT/120T
E=TRF250-080T/080U/080US
Figure T14-T17 Typical Time-to-trip Curves at 20°C for
Telecommunications and Networking Devices
Table T4 Dimensions & Weights for Telecommunications and Networking Devices
Cont’d
TS600/TSM600
600V
TS600-170F 18.3 19.4 11.6 12.3 7.2 8.3 1.7 2.4 9.9 10.4 1.5 2.3 —— T8 23.6
(0.72) (0.77) (0.46) (0.49) (0.29) (0.33) (0.07) (0.10) (0.39) (0.41) (0.06) (0.09)
TS600-200F-RA 18.3 19.4 11.6 12.3 7.2 8.3 1.7 2.4 9.9 10.4 1.5 2.3 —— T8 23.6
(0.72) (0.77) (0.46) (0.49) (0.29) (0.33) (0.07) (0.10) (0.39) (0.41) (0.06) (0.09)
TS600-400F 18.3 19.4 11.6 12.3 7.2 8.3 1.7 2.4 9.9 10.4 1.5 2.3 —— T8 19.8
(0.72) (0.77) (0.46) (0.49) (0.29) (0.33) (0.07) (0.10) (0.39) (0.41) (0.06) (0.09)
TSM600-250F 17.00 17.60 11.20 11.70 10.40 11.20 4.80 5.20 2.50 2.80 0.60 1.0 2.2 3.1 T9 31.2
(0.67) (0.69) (0.44) (0.46) (0.41) (0.44) (0.19) (0.20) (0.10) (0.11) (0.02) (0.04) (0.09) (0.12)
TSM600-250F-RA 17.00 17.60 11.20 11.70 10.40 11.20 4.80 5.20 2.50 2.80 0.60 1.0 2.2 3.1 T9 31.2
(0.67) (0.69) (0.44) (0.46) (0.41) (0.44) (0.19) (0.20) (0.10) (0.11) (0.02) (0.04) (0.09) (0.12)
TSM600-400F 17.00 17.60 11.20 11.70 10.40 11.20 4.80 5.20 2.50 2.80 0.60 1.0 2.2 3.1 T9 31.2
(0.67) (0.69) (0.44) (0.46) (0.41) (0.44) (0.19) (0.20) (0.10) (0.11) (0.02) (0.04) (0.09) (0.12)
600VAC interrupt products are designed to help equipment pass UL60950,TIA-968-A and GR1089 Port Type 1, 3 & 5 requirements.
Part Number
A
Min. Max. Figure
Device Mass (g)
(Only for reference)
B
Min. Max.
C
Min. Max.
D
Min. Max.
E
Min. Max.
F
Min. Max.
G
Min. Max.
Dimensions in Millimeters (Inches)
RoHS compliant, ELV compliant
224
12
Time-to-trip (s)
Fault Current (A)
1000
100
10
1
0.1
0.01
012 34567
E
C
B
A
D
E
A
B
C
D
Figure T17
TRF600/TS600/TSM600
A=TRF600-400/TS600-400/
TSM600-400F
B=TSM600-250F/
TS600-170F/200F
C=TRF600-160
D=TR600-150F-EX
E=TRF600-150
Operating temperature range for all listed products is -40°C to 85°C, except for TRF250-080T andTRF250-184 (0°C to 85°C)
TCF250*
Terminal material Nickel-plated copper foil
Test Conditions
Passive aging 60°C, 1000 hours
85°C, 1000 hours
Humidity aging 85°C, 85% RH, 1000 hours
Thermal shock 125°C, -55°C (10 times)
Solvent resistance MIL-STD-202, Method 215F
Note: Storage conditions: 40°C max., 70% RH max., devices should remain in original sealed bag prior to use. Devices may not meet specified values if these storage conditions are exceeded.
Physical Characteristics
Environmental Specifications
* 250VAC interrupt products are designed to help equipment pass ITU K.20, K.21, & K.45 recommendations andTelcordia GR-1089 PortType 2 & 4 requirements.
Table T5 Physical Characteristics and Environmental Specifications for
Telecommunications and Networking Devices
Figure T14-T17 Typical Time-to-trip Curves at 20°C for
Telecommunications and Networking Devices
Cont’d
Time-to-trip (s)
Fault Current (A)
100
10
1
0.10
0.01
0.00 0.50 1.00 1.50 2.00 2.50 3.00
A
A
B
C
B
C
Figure T16
TS250/TSV250/TSL250
A=TSV250-130F
B=TS250-130F
C=TSL250-080F
PolySwitch Resettable Devices Telecommunications & Networking Devices
225
RoHS Compliant, ELV Compliant
12
Terminal material Tin-plated brass, Nickel under-plating
Soldering characteristics EIC 60008-2-58
Test Conditions
Passive aging 60°C, 1000 hours
85°C, 1000 hours
Humidity aging 85°C, 85% RH, 500 hours
Thermal shock 125°C, -55°C (10 times)
Solvent resistance MIL-STD-202, Method 215F
Note: Storage conditions: 40°C max., 70% RH max., devices should remain in original sealed bag prior to use. Devices may not meet specified values if these storage conditions are exceeded.
TS250/TSV250/TSL250*
Physical Characteristics
Environmental Specifications
* 250VAC interrupt products are designed to help equipment pass ITU K.20, K.21, & K.45 recommendations andTelcordia GR-1089 PortType 2 & 4 requirements.
600VAC interrupt products are designed to help equipment pass UL60950,TIA-968-A and GR1089 Port Type 1, 3 & 5 requirements.
ExcludingTRF600-150 and TRF600-400, which have a coating that is not rated for dielectric withstand and can withstand 500h at 85°C/85% RH or 1000h at 60°C/90% RH.
Lead material Tin-plated copper, 22AWG
Insulating material Cured epoxy polymer
Flammability per IEC 695-2-2 Needle flame test for 20s
Soldering characteristics ANSI/J-STD-002, Category 3
Solder heat withstand IEC-STD 68-2-20, Test Tb, Section 5 Method 1A, Condition B: can withstand 10 seconds at 260°C±5°C
Note:
Devices are not designed to be placed through a reflow process.
TRF600†
Physical Characteristics
Test Conditions
Passive aging 60°C, 1000 hours
85°C, 1000 hours
Humidity aging 85°C, 85% RH, 1000 hours
Thermal shock 125°C, -55°C (10 times)
Solvent resistance MIL-STD-202, Method 215F
Note: Storage conditions: 40°C max., 70% RH max., devices should remain in original sealed bag prior to use. Devices may not meet specified values if these storage conditions are exceeded.
Environmental Specifications
Operating temperature range for all listed products is -40°C to 85°C, except for TRF250-080T andTRF250-184 (0°C to 85°C)
Table T5 Physical Characteristics and Environmental Specifications for
Telecommunications and Networking Devices
Cont’d
Lead material Tin-plated copper, 22AWG
Insulating material Cured epoxy polymer
Flammability per IEC 695-2-2 Needle Flame Test for 20s
Soldering characteristics ANSI/J-STD-002, Category 3
Solder heat withstand IEC-STD 68-2-20, Test Tb, Section 5 Method 1A, Condition B: can withstand 10 seconds at 260°C±5°C
Note: Devices are not designed to be placed through a reflow process.
Test Conditions
Passive aging 60°C, 1000 hours
85°C, 1000 hours
Humidity aging 85°C, 85% RH, 1000 hours
Thermal shock 125°C, -55°C (10 times)
Solvent resistance MIL-STD-202, Method 215F
Note: Storage conditions: 40°C max., 70% RH max., devices should remain in original sealed bag prior to use. Devices may not meet specified values if these storage conditions are exceeded.
TRF250*
Physical Characteristics
Environmental Specifications
226 RoHS Compliant, ELV Compliant
12
Test Conditions
Passive aging 60°C, 1000 hours
85°C, 1000 hours
Humidity aging 85°C, 85% RH, 1000 hours
Storage humidity Per IPC/JEDEC J-STD-020A Level 2a
Thermal shock 125°C, -55°C (10 times)
Solvent resistance MIL-STD-202, Method 215J
Note: Storage conditions: 40°C max., 70% RH max., devices should remain in original sealed bag prior to use. Devices may not meet specified values if these storage conditions are exceeded.
600VAC interrupt products are designed to help equipment pass UL60950,TIA-968-A and GR1089 Port Type 1, 3 & 5 requirements.
Terminal material Tin-plated brass
Insulating material Nylon resin (UL94V-0), 1000V dielectric rating
Flammability IEC 695-2-2 Needle Flame Test for 20s
Soldering characteristics EIC60068-2-58, Method 7
Solder heat withstand IEC-STD 68-2-20, Test Tb, Section 5 Method 1A
TSM600†
Physical Characteristics
Environmental Specifications
Operating temperature range for all listed products is -40°C to 85°C, except for TRF250-080T andTRF250-184 (0°C to 85°C)
Table T5 Physical Characteristics and Environmental Specifications for
Telecommunications and Networking Devices
Cont’d
Test Conditions
Passive aging 60°C, 1000 hours
85°C, 1000 hours
Humidity aging 85°C, 85% RH, 1000 hours
Thermal shock 125°C, -55°C (10 times)
Solvent resistance MIL-STD-202, Method 215F
Note: Storage conditions: 40°C max., 70% RH max., devices should remain in original sealed bag prior to use. Devices may not meet specified values if these storage conditions are exceeded.
Terminal material Tin-plated brass
Insulating material Nylon resin (UL94V-0), 1000V dielectric rating
Flammability IEC 695-2-2 Needle Flame Test for 20s
Soldering characteristics ANSI/J-STD-002, Category 3
Solder heat withstand IEC-STD 68-2-20, Test Tb, Section 5 Method 1A
TS600†
Physical Characteristics
Environmental Specifications
PolySwitch Resettable Devices Telecommunications & Networking Devices
227
RoHS Compliant, ELV Compliant
12
Chip* 250VAC
TCF250
TCF250-100T 2,500 10,000 ——
TCF250-120T 2,500 10,000 ——
TCF250-145T 2,500 10,000 ——
TCF250-180 2,500 10,000 UL
Radial-leaded* 250VAC
TRF250
TRF250-055UT 500 10,000 ——
TRF250-080U 500 10,000 UL, CSA, TÜV
TRF250-080U-2 1,500 7,500 UL, CSA, TÜV
TRF250-080T 500 10,000 08F UL, CSA, TÜV
TRF250-110U 500 10,000 UL, CSA, TÜV
TRF250-120 500 10,000 20F UL, CSA, TÜV
TRF250-120-2 1,500 7,500 20F UL, CSA, TÜV
TRF250-120T 500 10,000 20F UL, CSA, TÜV
TRF250-120T-2 1,500 7,500 20F UL, CSA, TÜV
TRF250-120U 500 10,000 20F UL, CSA, TÜV
TRF250-120U-2 1,500 7,500 20F UL, CSA, TÜV
TRF250-120UT 500 10,000 20F UL, CSA, TÜV
TRF250-145 500 10,000 45F UL, CSA, TÜV
TRF250-145-2 1,500 7,500 45F UL, CSA, TÜV
TRF250-145-RA 500 10,000 45F UL, CSA, TÜV
TRF250-145U 500 10,000 45F UL, CSA, TÜV
TRF250-145U-2 1,500 7,500 45F UL, CSA, TÜV
TRF250-183 500 10,000 83F UL, CSA, TÜV
TRF250-183-2 1,500 7,500 83F UL, CSA, TÜV
TRF250-184 500 10,000 84F UL, CSA, TÜV
Surface-mount* 250VAC
TS250/TSL250/TSV250
TSL250-080F-2 1,500 7,500 T08 UL, CSA,TÜV
TS250-130F-2 1,500 7,500 T13 UL, CSA, TÜV
TSV250-130F-2 1,200 6,000 T13V UL, CSA, TÜV
Radial-leaded 600VAC
TRF600
TRF600-150 500 10,000 150F UL, CSA, TÜV
TRF600-150-2 1,500 7,500 150F UL, CSA, TÜV
TR600-150F-EX 500 10,000 150F UL, CSA
TR600-150F-EX-2 600 3,000 150F UL, CSA
TR600-150F-EX-RA-B-0.5 500 10,000 150F UL, CSA
TRF600-160 500 10,000 160F UL, CSA, TÜV
TRF600-160-2 600 3,000 160F UL, CSA, TÜV
TRF600-400 500 10,000 400F UL, CSA
Surface-mount 600VAC
TS600/TSM600
TS600-170F-2 300 900 T20 UL, CSA
TS600-200F-RA-2 300 900 T20 UL, CSA
TS600-400F-2 300 900 T40 UL, CSA
TSM600-250F-2 200 1,000 TSM600 UL, CSA
TSM600-250F-RA-2 200 1,000 TSM600 UL, CSA
TSM600-400F-2 200 1,000 TSM600 UL
Part Number
Bag
Quantity
Tape & Reel
Quantity
Standard Package
Quantity Part Marking Agency Recognition
* 250VAC interrupt products are designed to help equipment pass ITU K.20, K.21, & K.45 recommendations andTelcordia GR-1089 PortType 2 & 4 requirements.
600VAC interrupt products are designed to help equipment pass UL60950,TIA-968-A and GR1089 Port Type 1, 3 & 5 requirements.
NEW
Table T6
Packaging and Marking Information for Telecommunications and Networking Devices
NEW
NEW
RoHS compliant, ELV compliant
228
12
Solder Reflow and Rework Recommendations for Telecommunications Surface-mount Devices
Solder Reflow
Recommended reflow method: IR, vapor phase oven, hot air oven.
Surface-mount devices are not designed to be wave soldered to the bottom side of the board.
Recommended maximum paste thickness of 0.25mm (0.010 in).
Devices can be cleaned using standard industry methods and solvents.
Rework
If a device is removed from the board, it should be discarded and replaced with a new device.
Profile Feature Pb-Free Assembly
Average ramp up rate (TsMAX to Tp) 3°C/second max.
Preheat
Temperature min. (TsMIN) 150°C
Temperature max. (TsMAX) 200°C
Time (tsMIN to tsMAX) 60-180 seconds
Time maintained above:
Temperature (TL) 217°C
Time (tL) 60-150 seconds
Peak/Classification temperature (Tp) 260°C
Time within 5°C of actual peak temperature
Time (tp) 20-40 seconds
Ramp down rate 6°C/second max.
Time 25°C to peak temperature 8 minutes max.
Critical Zone
T
L
to Tp
Ramp up
t 25˚C to Peak
Reflow Profile Time
Ramp down
ts
Preheat
Ts
MAX
T
L
Tp
tp
25
Ts
MIN
t
L
Temperature
Figure T21
Note: All temperatures refer to topside of the package, measured on the package
body surface.
Agency Recognition for Telecommunications and Networking Devices
UL File # E74889
CSA File #78165C
TÜV Per IEC60730-1 Certificate # for individual products available upon request.
Device AB C D EFG Figure
TS250 (All) 4.60 1.80 6.10 —— T18
(0.180) (0.070) (0.240) ——
TSV250 (All) 2.29 2.41 6.35 3.43 —— T19
(0.090) (0.095) (0.250) (0.135) ——
TSL250 (All) 3.60 1.80 5.50 —— T18
(0.140) (0.070) (0.220) ——
TS600 (All) 10.42 3.30 3.35 —— T18
(0.410) (0.130) (0.132) ——
TSM600 (All) 5.20 17.80 5.54 6.75 2.08 3.12 8.39 T20
(0.205) (0.701) (0.218) (0.266) (0.082) (0.123) (0.331)
A
BCB
Figure T18
A
A
B B
C
D
Figure T19
A
B
C D
G
E
F
Figure T20
Table T7 Recommended Pad Layouts for Surface-mount Telecommunications and Networking
Devices in millimeters (inches) Nominal
PolySwitch Resettable Devices Telecommunications & Networking Devices
229
RoHS Compliant, ELV Compliant
12
Dimension
Description EIA Mark IEC Mark Dimension (mm) Tolerance
Carrier tape width WW18 -0.5/+1.0
Hold down tape width W4W05 Minimum
Top distance between tape edges W6W23 Maximum
Sprocket hole position W5W19 -0.5/+0.75
Sprocket hole diameter D0D04 ±0.2
Abcissa to plane (straight lead) HH18.5 ±3.0
Abcissa to plane (kinked lead)* H0H016 -0.5/+0.6
Abcissa to top H1H132.2 Maximum
Overall width with lead protrusion —C
143.2 Maximum
Overall width without lead protrusion —C
242.5 Maximum
Lead protrusion L1I11.0 Maximum
Protrusion of cut-out LL11 Maximum
Protrusion beyond hold down tape I2I2Not specified
Sprocket hole pitch P0P012.7 ±0.3
Device pitch (TRF250 & TRF600-150) ——12.7
Device pitch (TRF600-160/400) ——25.4
Pitch tolerance ——20 consecutive ±1
Tape thickness tt0.9 Maximum
Tape thickness with splice* t1 2.0 Maximum
Splice sprocket hole alignment ——0±0.3
Body lateral deviation hh0±1.0
Body tape plane deviation pp0±1.3
Lead spacing plane deviation P1P10 ±0.7
Lead spacing* FF5.08 ±0.6
Reel width w2w 56 Maximum
Reel diameter ad370 Maximum
Space between flanges less device w1 4.75 ±3.25
Arbor hole diameter cf26 ±12.0
Core diameter nh80 Maximum
Box ——56/372/372 Maximum
Consecutive missing pieces* ——3 maximum
Empty places per reel* ——Not specified
* Differs from EIA specification.
TRF250/TRF600 devices are available in tape and reel packaging per EIA 468-B standard. See Figures T23 and T24 for details.
Table T8 TRF250/TRF600 Tape and Reel Specifications for
Telecommunications and Networking Device
Wave Soldering and Rework Recommendations for Telecommunications Radial-leaded Devices
Recommended Wave Soldering
Soldering temperature profile
Temperature characteristic at component terminal with dual
wave soldering
Rework
If a device is removed from the board, it should be discarded
and replaced with a new device.
300
250
200
150
100
50
0050
10s
245˚C ... 260˚C
10C... 130˚C
Forced cooling
100150200 250
Te m perature (˚C)
Time (s)
Figure T22
230 RoHS Compliant, ELV Compliant
12
w1
n
a
c
w2
Cross section
Direction of
unreeling
Reel
Type
Upper side
Lower side
Optional shape: Circular or polygonal
Figure T24 Reel Dimensions for TRF Devices
Dh
H1P1
W4
H0
H1
C1
C2
F
AB
Reference plane
Direction of unreeling
Cross section A-B
W5
H
W
t
P0D0
I2
L
L1
DhDpDp
Figure T23 EIA Referenced Taped Component Dimensions for TRF Devices
PolySwitch Resettable Devices Telecommunications & Networking Devices
231
RoHS Compliant, ELV Compliant
12
Carrier tape width W 16 ±0.30 16.0 ±0.30 16 ±0.30
Sprocket hole pitch P04.0 ±0.10 4.0 ±0.10 4.0 ±0.10
P112.0 ±0.10 8.0 ±0.10 8.0 ±0.10
P22.0 ±0.10 2.0 ±0.10 2.0 ±0.10
A06.9 ±0.23 5.5 ±0.10 5.5 ±0.10
B09.6 ±0.15 6.2 ±0.10 7.9 ±0.10
B1max. 12.1 8.0 9.2
Sprocket hole diameter D01.5 -0/+0.1 1.55 ±0.05 1.55 ±0.05
F 7.5 ±0.10 7.5 ±0.10 7.5 ±0.10
E11.75 ±0.10 1.75 ±0.10 1.75 ±0.10
E2min. 14.25 ——
Tape thickness T max. 0.4 0.45 0.35
Tape thickness with T1max. 0.1 0.1 0.1
splice cover tape thickness
K03.4 ±0.15 7.0 ±0.10 3.70 ±0.10
Leader min. 300 390 390
Trailer min. 300 160 160
Reel dimensions
Reel diameter A max. 340 340 340
Core diameter N min. 50 50 50
Space between flanges less device W116.4 -0/+2.0 16.4 -0/+2.0 16.4 -0/+2.0
Reel width W2max. 22.4 22.4 22.4
TS devices are packaged per EIA 481 and EIA 481-2 standards. See Figures T25 and T26 for details.
EIA Mark
TS250
Dimension(mm) Tolerance(mm)
TSV250
Dimension(mm) Tolerance(mm)
TSL250
Dimension(mm) Tolerance(mm)
Dimension
Description
TS250/TSL250/TSV250
Table T9 TS Tape and Reel Specifications for Telecommunications and Networking Devices
Dimension
Description EIA Mark Dimension (mm) Tolerance
Carrier tape width W 32 ±0.3
Sprocket hole pitch P04.0 ±0.1
P116 ±0.1
P22.0 ±0.1
A010 ±0.1
B019.2 ±0.1
B1max. 21.6
Sprocket hole diameter D01.5 -0/+1.0
F 14.2 ±0.1
E11.75 ±0.1
E2min. 28.4 ±0.1
Tape thickness T max. 0.50 ±0.5
Tape thickness with splice T1max. 0.1
K013.2 ±0.1
Leader min. 390
Trailer min. 160
Reel Dimensions
Reel diameter A max. 360
Core diameter N min. 50
Space between flanges less device W132.4 -0/+2.0
Reel width W2max. 40
TS600
232 RoHS Compliant, ELV Compliant
12
P0
E1
E2
FW
P2
D0
A0
B0
P1
B1
T1
K0
T
Cover tape
Embossment
Center lines
of cavity
A
Cover tape
Embossed cavity
Carrier tape
N (hub dia.)
W2(measured at hub)
W1(measured at hub)
Figure T25 EIA Referenced Taped Component Dimensions for TS Devices
Figure T26 EIA Referenced Reel Dimensions for TS Devices
TS devices are packaged per EIA 481 and EIA 481-2 standards. See Figures T25 and T26 for details.
Table T9 TS Tape and Reel Specifications for Telecommunications and Networking Devices
Cont’d
Dimension
Description EIA Mark Dimension (mm) Tolerance
Carrier tape width W 32 ±0.3
Sprocket hole pitch P04.0 ±0.1
P124 ±0.1
P22.0 ±0.1
A011.2 ±0.1
B017.8 ±0.1
B1max. 23.45
Sprocket hole diameter D 1.5 -0/+1.0
F 14.2 ±0.1
E11.74 ±0.1
E2max. 28.4 ±0.1
Tape thickness T max. 0.5 ±0.5
Tape thickness with splice T1max. 0.1
K011.9 ±0.1
Leader min. 390
Trailer min. 160
Reel Dimensions
Reel diameter A max. 360
Core diameter N min. 50
Space between flanges less device W132.4 -0/+2.0
Reel width W2max. 40
TSM600
PolySwitch Resettable Devices Telecommunications & Networking Devices
233
RoHS Compliant, ELV Compliant
12
Resistance-sorted and Resistance-matched Devices
Resistance-sorted devices (part number suffix “Rx”, where x = 1, 2, A, B, C, F etc.) are supplied with resistance values that are within
specified segments of the device’s full range of resistance.
Feature
Narrow resistance range.
Benefits
Greater flexibility for design engineers.
Lower resistance devices can allow for increased loop length on line card designs.
Higher resistance devices may provide greater protection by offering faster time-to-trip.
Resistance-sorted Devices
Most TCF, TRF and TS devices are available in resistance-sorted and/or resistance-matched versions.
Resistance-matched devices are supplied such that all parts in one particular package (or reel) are within 0.5of each other
(1.0forTRF250-080T devices). Individual matched packages are supplied from the full resistance range of the specified device.
Feature
Tighter resistance balance between any two parts in a package.
Benefits
Resistance-matched devices may reduce the tip-ring resistance differential, reducing the possibility of line imbalance.
Resistance-matched Devices
Part Numbering System for Radial-leaded Telecommunications and Networking Devices
TRF*250 -120 T-RA -B-0.5 -2
Packaging
2 = Tape and Reel
0.130 = special lead length in inches
(Blank) = Bulk
B-x.x = Resistance matchedin bins of x.x(optional)
Rx = Resistance range (optional)
Modifier (optional)
U = Uncoated
S = Straight lead
T = Fast Trip device
Hold Current (mA)
Product Series(TRF250, TRF600)
* F = RoHS compliant, ELV compliant
Part Numbering System for Surface-mount Telecommunications and Networking Devices
TSx -200 F -RA -B-0.5 -2
Packaging
2 = Tape and Reel
(Blank) = Bulk
B-x.x = Resistance matchedin bins of x.x(optional)
Rx = Resistance range (optional)
F = RoHS Compliant, ELVCompliant
Hold Current (mA)
Product Series(TS250,TSV250,TSL250,TS600, TSM600)
234 RoHS Compliant, ELV Compliant
12
Part Numbering System for Chip Telecommunications and Networking Devices
TCF*250 -120 T-RA -B-0.5
B-x.x = Resistance matchedin bins of x.x(optional)
Rx = Resistance range (optional)
Modifier (optional)
T = Fast Trip device
Hold Current (mA)
Product Series
* F = RoHS compliant, ELV compliant