https://www.phoenixcontact.com/us/products/2313669 Modem-PSI-MODEM-SHDSL/SERIAL-2313669 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Industrial SHDSL extender for serial RS-232/422/485 interfaces, point-to-point and line structures, serial data transmission up to 2000 kbps on in-house cables, diagnostics via USB and LEDs, two configurable alarm outputs Your advantages Distances up to 20 km RS-232, up to 230.4 kbps RS-422, up to 2000 kbps RS-485, up to 2000 kbps Robust modulation method (SHDSL) Two digital outputs for alerting external controllers Easy configuration For in-house cables Key Commercial Data Packing unit 1 pc GTIN GTIN 4046356509220 Weight per Piece (excluding packing) 360.000 g Custom tariff number 85176200 Country of origin Germany Technical data Note Utilization restriction EMC: class A product, see manufacturer's declaration in the download area 01/08/2021Page1/9 https://www.phoenixcontact.com/us/products/2313669 Modem-PSI-MODEM-SHDSL/SERIAL-2313669 Technical data Note Use in potentially explosive areas is not permitted in China. Dimensions Width 35 mm Height 99 mm Depth 114.5 mm Ambient conditions Ambient temperature (operation) -20 C ... 60 C (Freestanding (40 mm spacing to the right and left), no supply of other modules via the device) -20 C ... 55 C (Mounted in rows with zero spacing and low power dissipation of aligned modules) -20 C ... 50 C (Mounted in rows with zero spacing) -20 C ... 45 C (Other modules supplied via the device, max. 1.5A) Ambient temperature (storage/transport) -40 C ... 85 C Permissible humidity (operation) 10 % ... 95 % (non-condensing) Permissible humidity (storage/transport) 10 % ... 95 % (non-condensing) Altitude 5000 m (For restrictions, see the manufacturer's declaration for altitude operation) Degree of protection IP20 Noise immunity EN 61000-6-2 General Electrical isolation DIN EN 50178 (VCC, RS-232 // RS-422, RS-485 // DSL (A) // DSL (B) // FE) Test voltage data interface/power supply 1.5 kVrms (50 Hz, 1 min.) Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU Noise emission EN 55011 Net weight 339.4 g Housing material PA 6.6-FR Color green MTBF 1004 Years (Telcordia standard, 25C temperature, 21% operating cycle (5 days a week, 8 hours a day)) 199 Years (Telcordia standard, 40C temperature, 34.25% operating cycle (5 days a week, 12 hours a day)) MTTF 693 Years (SN29500 standard, temperature25C, operating cycle21%) 301 Years (SN29500 standard, temperature40C, operating cycle34.25%) 121 Years (SN29500 standard, temperature40C, operating cycle100%) Power supply 01/08/2021Page2/9 https://www.phoenixcontact.com/us/products/2313669 Modem-PSI-MODEM-SHDSL/SERIAL-2313669 Technical data Power supply Nominal supply voltage 24 VDC 5 % (as an alternative or redundant, via backplane bus contact and system current supply) 5 VDC (configuration only, via mini-USB type B) Supply voltage range 18 VDC ... 30 VDC Typical current consumption < 180 mA (24VDC) Connection method COMBICON plug-in screw terminal block Interfaces Interface 1 V.24 (RS-232) interface in acc. with ITU-T V.28, EIA/TIA-232, DIN66259-1 Interface RS-232 Connection method D-SUB9 plug Transmission length max. 15 m Termination resistor 390 - 180 - 390 (can be connected) Conductor cross section solid min. 0.2 mm Conductor cross section solid max. 2.5 mm Conductor cross section flexible min. 0.2 mm Conductor cross section flexible max. 2.5 mm Conductor cross section AWG min. 24 Conductor cross section AWG max. 14 Data flow control/protocols Software handshake, Xon/Xoff, hardware handshake (RTS/CTS), 3964Rcompatible, Modbus (RTU/ASCII), transparent protocol - additional protocols supported Serial transmission speed 0.11/0.3/1.2/2.4/4.8/9.6/19.2/38.4/57.6/115.2/230.4 kbps, NRZ Interface 2 SHDSL interface according to ITU-T G.991.2.bis Connection method 2 x 2-pos. COMBICON plug-in screw terminal blocks Transmission length 20 km (Depending on data rate and cable cross section) Serial transmission speed 4-wire operation: 64 kbps ... 30 Mbps 2-wire operation: 32 kbps ... 15.3 Mbps Interface 3 USB 2.0 Connection method Mini-USB type B, 5-pos. Transmission length < 5 m (only for configuration and diagnostics) Interface 4 RS-422 interface in acc. with ITU-T V.11, EIA/TIA-422, DIN 66348-1 Interface RS-422 Connection method Plug-in/screw connection via COMBICON File format/coding Serial asynchronous UART/NRZ, 7/8 data bits, 1/2 stop bits, 1 parity bit (even, odd, mark, space, none), 9/10/11-bit character length Transmission length 1200 m Termination resistor 390 - 180 - 390 (can be connected) Data flow control/protocols Automatic control // Modbus RTU/ASCII 01/08/2021Page3/9 https://www.phoenixcontact.com/us/products/2313669 Modem-PSI-MODEM-SHDSL/SERIAL-2313669 Technical data Interfaces Serial transmission speed 1.2/2.4/4.8/7.0/9.6/19.2/38.4/57.6/75/93.75/115.2/136/187.5/375/500/1500/2000 kbps, NRZ Interface 5 RS-485 interface, in acc. with EIA/TIA-485, DIN 66259-4/RS-485 2-wire Interface RS-485 Connection method Plug-in/screw connection via COMBICON File format/coding Serial asynchronous UART/NRZ, 7/8 data, 1/2 stop, 1 parity, 10/11-bit character length Transmission length 1200 m Termination resistor 390 - 180 - 390 (can be connected) Protocols supported Transparent, including 3964R protocol Data flow control/protocols Automatic control // Modbus RTU/ASCII Serial transmission speed 1.2/2.4/4.8/7.0/9.6/19.2/38.4/57.6/75/93.75/115.2/136/187.5/375/500/1500/2000 kbps, NRZ Function Management User-friendly software: Guided configuration, plausibility checks, diagnostic functions, log book Status and diagnostic indicators LEDs: VCC (supply voltage), RD/TD (serial data traffic), ERR (errors), TERM (termination resistor active), RS-232 (RS-232 active) 2 x LINK / 2 x STAT (DSL data traffic port A and port B), DIAG (diagnostic messages) Digital outputs Output name Digital output Number of outputs 2 Voltage output signal depending on the operating voltage Current output signal 150 mA (Short-circuit-proof) Conformance/approvals Designation CE Identification CE-compliant Designation EAC Identification EAC Designation ATEX Identification II 3 G Ex nA nC IIC T4 Gc X Additional text Please follow the special installation instructions in the documentation! Designation UL, USA/Canada Identification 508 Listed Designation Corrosive gas test Identification ISA-S71.04-1985 G3 Harsh Group A Standards and Regulations 01/08/2021Page4/9 https://www.phoenixcontact.com/us/products/2313669 Modem-PSI-MODEM-SHDSL/SERIAL-2313669 Technical data Standards and Regulations Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU Noise emission EN 55011 Noise immunity EN 61000-6-2 Standards/regulations EN50121-4 Shock 15g in all directions in acc. with IEC 60068-2-27 Vibration (operation) in acc. with IEC 60068-2-6: 5g, 150 Hz Environmental Product Compliance REACh SVHC Lead 7439-92-1 China RoHS Environmentally Friendly Use Period = 50 years For details about hazardous substances go to tab "Downloads", Category "Manufacturer's declaration" Drawings SHDSL SHDSL 4 Wire SHDSL SHDSL 2 Wire SHDSL Application drawing SHDSL Application drawing RS 232 RS 422 RS 485 RS 232 RS 422 RS 485 RS 232 RS 422 RS 485 RS 232 RS 422 RS 485 Point-to-point connection (2-wire) Point-to-point connection (4-wire) 01/08/2021Page5/9 https://www.phoenixcontact.com/us/products/2313669 Modem-PSI-MODEM-SHDSL/SERIAL-2313669 SHDSL SHDSL SHDSL SHDSL SHDSL Application drawing SHDSL Application drawing RS 232 RS 422 RS 485 RS 232 RS 422 RS 485 RS 232 RS 422 RS 485 RS 232 RS 232 RS 422 RS 485 RS 232 RS 422 RS 485 Linear structure (2-wire) Linear structure (2-wire) Application drawing Application drawing SHDSL ... SHDSL SHDSL SHDSL ... SHDSL SHDSL ... SHDSL ... Not possible SHDSL SHDSL RS 485 RS 485 RS 485 RS 485 RS 485 ... Multipoint communication via SHDSL not supported Star structure via DIN rail connector Classifications eCl@ss eCl@ss 10.0.1 19060590 eCl@ss 11.0 19060590 eCl@ss 4.0 27240400 eCl@ss 4.1 27240400 eCl@ss 5.0 19030100 eCl@ss 5.1 19030100 eCl@ss 6.0 19060500 eCl@ss 7.0 19060590 eCl@ss 8.0 19060590 eCl@ss 9.0 19060590 01/08/2021Page6/9 https://www.phoenixcontact.com/us/products/2313669 Modem-PSI-MODEM-SHDSL/SERIAL-2313669 Classifications ETIM ETIM 2.0 EC000310 ETIM 3.0 EC000740 ETIM 4.0 EC000740 ETIM 5.0 EC000740 ETIM 6.0 EC000740 ETIM 7.0 EC000740 UNSPSC UNSPSC 6.01 30211506 UNSPSC 7.0901 39121008 UNSPSC 11 39121008 UNSPSC 12.01 39121008 UNSPSC 13.2 43222628 UNSPSC 18.0 43222628 UNSPSC 19.0 43222628 UNSPSC 20.0 43222628 UNSPSC 21.0 43222628 Approvals Approvals Approvals UL Listed / cUL Listed / EAC-RoHS / EAC / cULus Listed Ex Approvals ATEX Approval details UL Listed http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 238705 cUL Listed http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 238705 01/08/2021Page7/9 https://www.phoenixcontact.com/us/products/2313669 Modem-PSI-MODEM-SHDSL/SERIAL-2313669 Approvals RU DDE.HB35.B.00388 EAC RU *DE.A*30.B.01735 cULus Listed EAC-RoHS Accessories Accessories Data plug D-SUB bus connector-SUBCON 9/M-SH-2761509 D-SUB connector, 9-pos., male connector, one cable entry < 35, universal type for all systems, pin assignment: 1, 2, 3, 4, 5, 6, 7, 8, 9 to screw connection terminal block DIN rail connector DIN rail bus connectors-ME 17,5 TBUS 1,5/ 5-ST-3,81 GN-2709561 DIN rail connector for DIN rail mounting. Universal for TBUS housing. Gold-plated contacts, 5-pos. Power supply 01/08/2021Page8/9 https://www.phoenixcontact.com/us/products/2313669 Modem-PSI-MODEM-SHDSL/SERIAL-2313669 Accessories Power supply unit-MINI-SYS-PS-100-240AC/24DC/1.5-2866983 Primary-switched MINI POWER supply for DIN rail mounting, input: 1-phase, output: 24 V DC/1.5 A Programming cable USB cable-CABLE-USB/MINI-USB-3,0M-2986135 USB connecting cable: USB plug type A to USB plug type Mini-B; length: 3 m Shield connection clamp Shield connection clamp-SKS 8-SNS35-3062786 Shield connection terminal block, for applying the shield to busbars Surge protection for information technology Surge protection device-DT-TELE-SHDSL-2801593 Attachment plug with surge protection for two SHDSL telecommunications interfaces (ports). Connection: RJ45 (RJ12/ RJ11) and plug-in screw terminal block (COMBICON). Alternatively, can be snapped onto a DIN rail. Phoenix Contact 2021 (c) - all rights reserved http://www.phoenixcontact.com 01/08/2021Page9/9