https://www.phoenixcontact.com/us/products/2313669
01/08/2021Page1/9
Modem-PSI-MODEM-SHDSL/SERIAL-2313669
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Industrial SHDSL extender for serial RS-232/422/485 interfaces, point-to-point and line structures, serial data
transmission up to 2000 kbps on in-house cables, diagnostics via USB and LEDs, two configurable alarm outputs
Your advantages
Distances up to 20 km
RS-232, up to 230.4 kbps
RS-422, up to 2000 kbps
RS-485, up to 2000 kbps
Robust modulation method (SHDSL)
Two digital outputs for alerting external controllers
Easy configuration
For in-house cables
Key Commercial Data
Packing unit 1 pc
GTIN
GTIN 4046356509220
Weight per Piece (excluding packing) 360.000 g
Custom tariff number 85176200
Country of origin Germany
Technical data
Note
Utilization restriction EMC: class A product, see manufacturer's declaration in the download
area
https://www.phoenixcontact.com/us/products/2313669
01/08/2021Page2/9
Modem-PSI-MODEM-SHDSL/SERIAL-2313669
Technical data
Note
Use in potentially explosive areas is not permitted in China.
Dimensions
Width 35 mm
Height 99 mm
Depth 114.5 mm
Ambient conditions
Ambient temperature (operation) -20 °C ... 60 °C (Freestanding (40 mm spacing to the right and left), no
supply of other modules via the device)
-20 °C ... 55 °C (Mounted in rows with zero spacing and low power
dissipation of aligned modules)
-20 °C ... 50 °C (Mounted in rows with zero spacing)
-20 °C ... 45 °C (Other modules supplied via the device, max. 1.5A)
Ambient temperature (storage/transport) -40 °C ... 85 °C
Permissible humidity (operation) 10 % ... 95 % (non-condensing)
Permissible humidity (storage/transport) 10 % ... 95 % (non-condensing)
Altitude ≤ 5000 m (For restrictions, see the manufacturer's declaration for altitude
operation)
Degree of protection IP20
Noise immunity EN 61000-6-2
General
Electrical isolation DIN EN 50178 (VCC, RS-232 // RS-422, RS-485 // DSL (A) // DSL (B) //
FE)
Test voltage data interface/power supply 1.5 kVrms (50 Hz, 1 min.)
Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
Noise emission EN 55011
Net weight 339.4 g
Housing material PA 6.6-FR
Color green
MTBF 1004 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5
days a week, 8 hours a day))
199 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle
(5 days a week, 12 hours a day))
MTTF 693 Years (SN29500 standard, temperature25°C, operating cycle21%)
301 Years (SN29500 standard, temperature40°C, operating
cycle34.25%)
121 Years (SN29500 standard, temperature40°C, operating cycle100%)
Power supply
https://www.phoenixcontact.com/us/products/2313669
01/08/2021Page3/9
Modem-PSI-MODEM-SHDSL/SERIAL-2313669
Technical data
Power supply
Nominal supply voltage 24 VDC ±5 % (as an alternative or redundant, via backplane bus contact
and system current supply)
5 VDC (configuration only, via mini-USB type B)
Supply voltage range 18 VDC ... 30 VDC
Typical current consumption < 180 mA (24VDC)
Connection method COMBICON plug-in screw terminal block
Interfaces
Interface 1 V.24 (RS-232) interface in acc. with ITU-T V.28, EIA/TIA-232, DIN66259-1
Interface RS-232
Connection method D-SUB9 plug
Transmission length max. 15 m
Termination resistor 390 Ω - 180 Ω - 390 Ω (can be connected)
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 2.5 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 14
Data flow control/protocols
Software handshake, Xon/Xoff, hardware handshake (RTS/CTS), 3964R-
compatible, Modbus (RTU/ASCII), transparent protocol - additional
protocols supported
Serial transmission speed 0.11/0.3/1.2/2.4/4.8/9.6/19.2/38.4/57.6/115.2/230.4 kbps, NRZ
Interface 2 SHDSL interface according to ITU-T G.991.2.bis
Connection method 2 x 2-pos. COMBICON plug-in screw terminal blocks
Transmission length ≤ 20 km (Depending on data rate and cable cross section)
Serial transmission speed 4-wire operation: 64 kbps ... 30 Mbps
2-wire operation: 32 kbps ... 15.3 Mbps
Interface 3 USB 2.0
Connection method Mini-USB type B, 5-pos.
Transmission length < 5 m (only for configuration and diagnostics)
Interface 4 RS-422 interface in acc. with ITU-T V.11, EIA/TIA-422, DIN 66348-1
Interface RS-422
Connection method Plug-in/screw connection via COMBICON
File format/coding Serial asynchronous UART/NRZ, 7/8 data bits, 1/2 stop bits, 1 parity bit
(even, odd, mark, space, none), 9/10/11-bit character length
Transmission length ≤ 1200 m
Termination resistor 390 Ω - 180 Ω - 390 Ω (can be connected)
Data flow control/protocols Automatic control // Modbus RTU/ASCII
https://www.phoenixcontact.com/us/products/2313669
01/08/2021Page4/9
Modem-PSI-MODEM-SHDSL/SERIAL-2313669
Technical data
Interfaces
Serial transmission speed 1.2/2.4/4.8/7.0/9.6/19.2/38.4/57.6/75/93.75/115.2/136/187.5/375/500/1500/2000
kbps, NRZ
Interface 5 RS-485 interface, in acc. with EIA/TIA-485, DIN 66259-4/RS-485 2-wire
Interface RS-485
Connection method Plug-in/screw connection via COMBICON
File format/coding Serial asynchronous UART/NRZ, 7/8 data, 1/2 stop, 1 parity, 10/11-bit
character length
Transmission length ≤ 1200 m
Termination resistor 390 Ω - 180 Ω - 390 Ω (can be connected)
Protocols supported Transparent, including 3964R protocol
Data flow control/protocols Automatic control // Modbus RTU/ASCII
Serial transmission speed 1.2/2.4/4.8/7.0/9.6/19.2/38.4/57.6/75/93.75/115.2/136/187.5/375/500/1500/2000
kbps, NRZ
Function
Management User-friendly software: Guided configuration, plausibility checks, diagnostic
functions, log book
Status and diagnostic indicators
LEDs: VCC (supply voltage), RD/TD (serial data traffic), ERR (errors),
TERM (termination resistor active), RS-232 (RS-232 active)
2 x LINK / 2 x STAT (DSL data traffic port A and port B), DIAG (diagnostic
messages)
Digital outputs
Output name Digital output
Number of outputs 2
Voltage output signal depending on the operating voltage
Current output signal ≤ 150 mA (Short-circuit-proof)
Conformance/approvals
Designation CE
Identification CE-compliant
Designation EAC
Identification EAC
Designation ATEX
Identification  II 3 G Ex nA nC IIC T4 Gc X
Additional text Please follow the special installation instructions in the documentation!
Designation UL, USA/Canada
Identification 508 Listed
Designation Corrosive gas test
Identification ISA-S71.04-1985 G3 Harsh Group A
Standards and Regulations
https://www.phoenixcontact.com/us/products/2313669
01/08/2021Page5/9
Modem-PSI-MODEM-SHDSL/SERIAL-2313669
Technical data
Standards and Regulations
Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
Noise emission EN 55011
Noise immunity EN 61000-6-2
Standards/regulations EN50121-4
Shock 15g in all directions in acc. with IEC 60068-2-27
Vibration (operation) in acc. with IEC 60068-2-6: 5g, 150 Hz
Environmental Product Compliance
REACh SVHC Lead 7439-92-1
China RoHS Environmentally Friendly Use Period = 50 years
For details about hazardous substances go to tab “Downloads”, Category
“Manufacturer's declaration”
Drawings
Application drawing
SHDSL
SHDSL
RS232
RS422
RS485
RS232
RS422
RS485
SHDSL2Wire
Point-to-point connection (2-wire)
Application drawing
SHDSL
SHDSL
RS232
RS422
RS485
RS232
RS422
RS485
SHDSL4Wire
Point-to-point connection (4-wire)
https://www.phoenixcontact.com/us/products/2313669
01/08/2021Page6/9
Modem-PSI-MODEM-SHDSL/SERIAL-2313669
Application drawing
SHDSL
SHDSL
SHDSL
RS232
RS422
RS485
RS232
RS422
RS485
RS232
RS422
RS485
Linear structure (2-wire)
Application drawing
SHDSL
SHDSL
SHDSL
RS232
RS232
RS422
RS485
RS232
RS422
RS485
Linear structure (2-wire)
Application drawing
...
SHDSL
...
SHDSL
...
SHDSL
Notpossible
Multipoint communication via SHDSL not supported
Application drawing
SHDSL
SHDSL
SHDSL
SHDSL
SHDSL
SHDSL
......
RS485
RS485 RS485 RS485 RS485
Star structure via DIN rail connector
Classifications
eCl@ss
eCl@ss 10.0.1 19060590
eCl@ss 11.0 19060590
eCl@ss 4.0 27240400
eCl@ss 4.1 27240400
eCl@ss 5.0 19030100
eCl@ss 5.1 19030100
eCl@ss 6.0 19060500
eCl@ss 7.0 19060590
eCl@ss 8.0 19060590
eCl@ss 9.0 19060590
https://www.phoenixcontact.com/us/products/2313669
01/08/2021Page7/9
Modem-PSI-MODEM-SHDSL/SERIAL-2313669
Classifications
ETIM
ETIM 2.0 EC000310
ETIM 3.0 EC000740
ETIM 4.0 EC000740
ETIM 5.0 EC000740
ETIM 6.0 EC000740
ETIM 7.0 EC000740
UNSPSC
UNSPSC 6.01 30211506
UNSPSC 7.0901 39121008
UNSPSC 11 39121008
UNSPSC 12.01 39121008
UNSPSC 13.2 43222628
UNSPSC 18.0 43222628
UNSPSC 19.0 43222628
UNSPSC 20.0 43222628
UNSPSC 21.0 43222628
Approvals
Approvals
Approvals
UL Listed / cUL Listed / EAC-RoHS / EAC / cULus Listed
Ex Approvals
ATEX
Approval details
UL Listed http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 238705
cUL Listed http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 238705
https://www.phoenixcontact.com/us/products/2313669
01/08/2021Page8/9
Modem-PSI-MODEM-SHDSL/SERIAL-2313669
Approvals
EAC-RoHS RU D-
DE.HB35.B.00388
EAC RU *-
DE.A*30.B.01735
cULus Listed
Accessories
Accessories
Data plug
D-SUB bus connector-SUBCON 9/M-SH-2761509
D-SUB connector, 9-pos., male connector, one cable entry < 35°, universal type for all systems, pin assignment: 1, 2, 3,
4, 5, 6, 7, 8, 9 to screw connection terminal block
DIN rail connector
DIN rail bus connectors-ME 17,5 TBUS 1,5/ 5-ST-3,81 GN-2709561
DIN rail connector for DIN rail mounting. Universal for TBUS housing. Gold-plated contacts, 5-pos.
Power supply
https://www.phoenixcontact.com/us/products/2313669
01/08/2021Page9/9
Modem-PSI-MODEM-SHDSL/SERIAL-2313669
Accessories
Power supply unit-MINI-SYS-PS-100-240AC/24DC/1.5-2866983
Primary-switched MINI POWER supply for DIN rail mounting, input: 1-phase, output: 24 V DC/1.5 A
Programming cable
USB cable-CABLE-USB/MINI-USB-3,0M-2986135
USB connecting cable: USB plug type A to USB plug type Mini-B; length: 3 m
Shield connection clamp
Shield connection clamp-SKS 8-SNS35-3062786
Shield connection terminal block, for applying the shield to busbars
Surge protection for information technology
Surge protection device-DT-TELE-SHDSL-2801593
Attachment plug with surge protection for two SHDSL telecommunications interfaces (ports). Connection: RJ45 (RJ12/
RJ11) and plug-in screw terminal block (COMBICON). Alternatively, can be snapped onto a DIN rail.
Phoenix Contact 2021 © - all rights reserved
http://www.phoenixcontact.com