ME10 10W-12W Single Output External Power Medical Series Features Meets UL/EN/IEC60601-1-2, 4th edition for EMC* Approved to EN/IEC/UL60601-1, 3rd edition applications with and isolation levels which satisfy the 2 MOPP requirements Meets DoE Efficiency Level VI Requirements Up to 12W of AC-DC Power Universal Input 90-264Vac Input Range LPS No load input power Average Efficiency Desktop and Wall-Plug versions Meets EN55011/CISPR11, FCC Part 15.109 Class B Conducted & Radiated Emissions, with 6db margin E-cap life of >7 years <1,000,000 Hours MTBF 3 Year Warranty IP22 Rated Enclosure Description A high performance AC to DC external power supply family designed for medical applications. The ME10 Medical Series external AC-DC power supplies are approved to safety EN/IEC/UL60601-1, 3rd edition, with isolation levels which satisfy the 2 * MOPP requirements; and designed to UL/EN/IEC60601-1-2, 4th edition for EMC . The ME10 Series models will operate at universal input range of 90 to 264Vac over the wide temperature range of -20C to +50C, delivering full rated output power up to +40C and applicable output power derating at 50C. These models are available in desktop and wall-plug versions, include an IP22 rating per IEC60529 for the enclosure, and output cable terminated at a variety of output connectors. *Consult Factory for Table 9 compliance information. Model Selection Model Number ME10A0503F01 ME10A0603F01 ME10A0703F01 ME10A0903F01 ME10A1203F01 ME10A1503F01 ME10A2403F01 ME10A0503N01 ME10A0603N01 ME10A0703N01 ME10A0903N01 ME10A1203N01 ME10A1503N01 ME10A2403N01 ME10A0503Q01 ME10A0603Q01 ME10A0703Q01 ME10A0903Q01 ME10A1203Q01 ME10A1503Q01 ME10A2403Q01 www.slpower.com Volts 5.0V 5.9V 7.5V 9.0V 12.0V 15.0V 24.0V 5.0V 5.9V 7.5V 9.0V 12.0V 15.0V 24.0V 5.0V 5.9V 7.5V 9.0V 12.0V 15.0V 24.0V Output Current 2.0A 1.6A 1.3A 1.1A 1.0A 0.8A 0.5A 2.0A 1.6A 1.3A 1.1A 1.0A 0.8A 0.5A 2.0A 1.6A 1.3A 1.1A 1.0A 0.8A 0.5A Output Power 10W 10W 10W 10W 12W 12W 12W 10W 10W 10W 10W 12W 12W 12W 10W 10W 10W 10W 12W 12W 12W Ripple & Noise 75mV pk-pk 75mV pk-pk 75mV pk-pk 90mV pk-pk 120mV pk-pk 150mV pk-pk 240mV pk-pk 75mV pk-pk 75mV pk-pk 75mV pk-pk 90mV pk-pk 120mV pk-pk 150mV pk-pk 240mV pk-pk 75mV pk-pk 75mV pk-pk 75mV pk-pk 90mV pk-pk 120mV pk-pk 150mV pk-pk 240mV pk-pk Line Regulation 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% ME10 Rev 2.7 Load Regulation 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% 02-MAY-16 Output Connector Input Configuration 2.5 x 5.5 x 9.5mm Straight Barrel Type, center positive Class I Desktop, IEC60320 C14 Receptacle 2.5 x 5.5 x 9.5mm Straight Barrel Type, center positive Class II Desktop, IEC60320 C8 Receptacle 2.5 x 5.5 x 9.5mm Straight Barrel Type, center positive Class II Desktop, IEC60320 C18 Receptacle 1 ME10 10W-12W Single Output External Power Medical Series Model Selection (continued) Model Number ME10A0503B01 ME10A0603B01 ME10A0703B01 ME10A0903B01 ME10A1203B01 ME10A1503B01 ME10A2403B01 ME10A0503C01 ME10A0603C01 ME10A0703C01 ME10A0903C01 ME10A1203C01 ME10A1503C01 ME10A2403C01 Notes: Volts 5.0V 5.9V 7.5V 9.0V 12.0V 15.0V 24.0V 5.0V 5.9V 7.5V 9.0V 12.0V 15.0V 24.0V Output Current 2.0A 1.6A 1.3A 1.1A 1.0A 0.8A 0.5A 2.0A 1.6A 1.3A 1.1A 1.0A 0.8A 0.5A Output Power 10W 10W 10W 10W 12W 12W 12W 10W 10W 10W 10W 12W 12W 12W Ripple & Noise 75mV pk-pk 75mV pk-pk 75mV pk-pk 90mV pk-pk 120mV pk-pk 150mV pk-pk 240mV pk-pk 75mV pk-pk 75mV pk-pk 75mV pk-pk 90mV pk-pk 120mV pk-pk 150mV pk-pk 240mV pk-pk Line Regulation 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% Load Regulation 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% Output Connector 2.5 x 5.5 x 9.5mm Straight Barrel Type, center positive 2.5 x 5.5 x 9.5mm Straight Barrel Type, center positive Input Configuration Class II Wall-Plug, Interchangeable Blades (North American Blade included) Class II Wall-Plug, Fixed North American Blades 1. Measured at the output connector, with noise probe directly across output and load terminated with 0.1F ceramic and 10F low ESR capacitors. For 5V and 6V models, values listed are typical, 100mV pk-pk maximum with 0.1F ceramic and 47F low ESR capacitors used at measurement point. 2. Order blade kit KT-1027K for other blades (EU. UK, Australia) 3. For EU fixed blades, replace "C" in the model number with "M", for UK blades, replace "C" with "G", for Australia blades, replace "C" with "H". 4. For Input Class I models: For AC GND connected to output common (-), insert a "B" in the part number where the "A" is located (ME10B0503F01). 5. All specifications are typical at nominal input, full load, at 25C ambient unless noted. General Specifications AC Input Input Current Inrush Current Input Fuses Earth Leakage Current Efficiency 100-240Vac, 10%, 47-63Hz, 1 Turn On Time Less than 700mS @115Vac, full load 115Vac: 0.45A, 230Vac: 0.22A Hold-up Time 20mS min., at full Load, 100Vac input 264Vac, cold start: will not exceed 40A F1, F2: 3.15A, 250Vac fuses (line & neutral lines) provided on all models Input-GND: <500A@264Vac, 60Hz, NC Output-GND: <4mA@264Vac, 60Hz, NC >87%, typical Output Power 10 to 12W continuous - See models chart for specific voltage model ratings. No Load Input Power <0.1W per DoE Efficiency Level VI Requirements Ripple and Noise See models chart Output Voltage See models chart Transient Response Regulation Drop Test Vibration E-Cap Life www.slpower.com Overtemperature Protection Overload Protection Short Circuit Protection Overvoltage Protection Isolation Safety Standards Operating Temperature Temperature Derating 500s response time for return to within 0.5% of final value for any 50% load step over the range of 5% to 100% of rated load, i/t< 0.2A/s. Max. voltage deviation is +/-3.5%. Storage Temperature Altitude See models chart 1.4m from table top to wooden platform, 6 faces. Operating: 0.003g/Hz, 1.5grms overall, 3 axes, 10 min/axis, 1-500Hz. Non-Oper.: random waveform, 3 minutes per axis, 3 axes and Sine waveform, Vib. frequency/acceleration: 10-500Hz/1g, sweep rate of 1 octave / minutes, Vibration time of 10 sweeps / axes, 3 axes >10 year life based on calculations at 115Vac/60Hz & 230Vac/50Hz, ambient 25C at 24 hrs per day, 365 days/year, 6 power up cycles per day. ME10 Rev 2.7 Relative Humidity 02-MAY-16 Will shutdown upon an overtemperature condition, auto-recovery. 130 to 180% of rating, Hiccup Mode Hiccup Mode, auto recovery. 130 to 150% of output voltage, hiccup mode Input-Output: 2 MOPP Input-Ground: 1 MOPP Output-Ground: 1500Vac EN/IEC/UL60601-1, 3rd edition and EN/IEC/UL60601-1-11:2010 for Home Healthcare -20C to +70C See derating chart -40C to +85C Operating: to 5000m. Non-operating: -500 to 40,000 ft. 5% to 95%, non-condensing Shock Operating: Half-sine, 20gpk, 10mS, 3 axes, 6 shocks total Non-Operating: Half-sine waveform, impact acceleration of 100G, Pulse duration of 6 mS, Number of shocks: 3 for each of the three axis MTBF >1,000,000 hours, full load, 110 & 220Vac input, 25C amb., per Telcordia 332 Issue 6, Stress Method. 2 ME10 10W-12W Single Output External Power Medical Series EMI/EMC Compliance Conducted Emissions: EN55011/CISPR11 Class B, FCC Part 15.107, Class B: 6db margin typ, at 115 and 230Vac Radiated Emissions: EN55011/CISPR11 Class B, FCC Part 15.109, Class B: 3db margin typ, at 115 and 230Vac Common Mode Noise: High Frequency (100kHz-20MHz): <40mA pk-pk Electro-Static Discharge (ESD) Immunity on Power ports: EN55024/IEC61000-4-2, Level 4: +/- 8kV contact, +/- 15kV air, Criteria A IEC60601-1-2, 4th Edition, Table 4 Radiated RF EM Fields Susceptibility EN55022/EN61000-4-3, 10V/m, 80MHz-2.7GHz, 80% AM at 1kHz IEC60601-1-2, 4th Edition, Table 4 Electrical Fast Transients (EFT) /Bursts: EN55024/IEC61000-4-4, Level 4, +/- 4.4kV, 100Khz rep rate, 40A, Criteria A IEC60601-1-2, 4th Edition, Table 5 Surges, Line to Line (Diff Mode) and Line to GND (CMN Mode) Conducted Disturbances induced by RF Fields Rated Power frequency magnetic fields Voltage Interruptions, Dips, Sags & Surges EN55024/IEC61000-4-5, Level 4, +/-2kV DM, +/-4kV CM, Criteria A Surpasses IEC60601-1-2, 4th Edition requirements. EN55022/IEC61000-4-6, 3.6V/m - Level 4, 0.15 to 80Mhz; and 12V/m) in ISM and amateur radio bands between 0.15Mhz and 80Mhz, 80% AM at 1KHz IEC60601-1-2, 4th Edition, Table 5 EN55024/IEC1000-4-8, Level 4: 30 A/m, 50/60 Hz IEC60601-1-2, 4th Edition, Table 4 EN55024/IECEN61000-4-11: --100% dip for 10 mS, at 0, 45, 90, 135, 180, 225, 270 and 315 degrees, 100% dip for 20mS, 0 deg., Criteria A --100% dip for 5000mS (250/300 cycles), Criteria B --60% dip for 100mS, Criteria B --30% dip for 500mS, Criteria A IEC60601-1-2, 4th Edition, Table 5 Harmonic Current Emissions EN55011/EN61000-3-2, Class A Flicker Test EN61000-3-3 All specifications are typical at nominal input, full load, at 25C ambient unless noted. Consult factory for information regarding testing for or usage under special environments. Mechanical Drawing IEC60320 C14 Receptacle, 2.5 x 5.5 x 9.5mm Barrel Connector Notes: www.slpower.com Interchangeable N.A. Blade, 2.5 x 5.5 x 9.5mm barrel connector 1. All dimensions in mm. 2. Weight = 110g 2. Interchangeable blade models come with North American blade fitted. For other blades (EU, UK, Aust.) order blade kit KT1027K. 3. The unit should not be covered or enclosed to protect against excessive case temperature rise. ME10 Rev 2.7 02-MAY-16 3 ME10 10W-12W Single Output External Power Medical Series Derating Chart: 14 12 Watts 10 8 5V 7V 6 12V 4 24V 2 0 -20 -10 0 10 20 30 40 50 60 70 Ambient Temperature C Connector Information Standard models include a 2.5 x 5.5 x 9.5mm straight barrel type connector (Ault #3), center positive. Other standard options are listed below. The "03" in the standard model number is replaced by the applicable digits below: Data Sheet (c) 2016 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice. www.slpower.com ME10 Rev 2.7 02-MAY-16 4