SPECIFICATION
18WAC-DC High Reliability IndustrialAdaptor GST18B series
File Name:GST18B-SPEC 2015-06-24
ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE Note.2
RATED CURRENT
CURRENT RANGE
RATED POWER (max.)
RIPPLE & NOISE (max.) Note.3
OUTPUT
SETUP, RISE, HOLD UP TIME
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT
INPUT
ENVIRONMENT
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
SAFETY STANDARDS
SAFETY &
EMC
(Note. 8)
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
PROTECTION
5V
GST18B05
GST18B05-P1J
GST18B09-P1J
GST18B15-P1J
GST18B24-P1J
GST18B48-P1J
GST18B07-P1J
GST18B12-P1J
GST18B18-P1J
GST18B28-P1J
7.5V
GST18B07
9V
GST18B09
12V
GST18B12
15V
GST18B15
18V
GST18B18
24V
GST18B24
28V
GST18B28
48V
GS18B48
3.0A 2.0A 2.0A 1.50A 1.20A 1.0A 0.75A 0.64A 0.375A
0 ~ 3.0A 0 ~ 2.0A 0 ~2.0A 0 ~ 1.20A 0 ~ 1.0A 0 ~ 0.75A
80mVp-p 80mVp-p 80mVp-p 100mVp-p 150mVp-p 180mVp-p 240mVp-p 240mVp-p
VOLTAGE TOLERANCE Note.4
LINE REGULATION Note.5
LOAD REGULATION Note.6
±5.0% ±5.0% ±5.0% ±3.0% ±3.0% ±3.0% ±2.0% ±2.0% ±2.0%
±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
±5.0% ±5.0% ±5.0% ±3.0% ±3.0% ±3.0% ±2.0% ±2.0% ±2.0%
47 ~ 63Hz
0.25mA / 240VAC
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:4242VDC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH℃
500Khrs min. MIL-HDBK-217F(25 )℃
-30 ~ +70 (Refer to "Derating Curve")℃
20% ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH℃
±℃℃0.03% / (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
79*54*33mm (L*W*H)
191.5g; 60pcs/12.5Kg/1.22CUFT
CONNECTOR
PLUG
CABLE
15W 15W 18W 18W
0 ~ 1.50A
18W 18W 18W 18W
0 ~ 0.64A
18W
0 ~ 0.375A
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient. ℃
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerance: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 10% to 100% rated load.
7.Derating may be needed under low input voltage. Please check the derating curve for more details.
8.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
OVERLOAD
OVER VOLTAGE
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Clamp by zener diode, output short
UL60950-1, CSA C22.2, TUV EN60950-1, BSMI CNS14336, CCC GB4943 approved
Compliance to EN55022 class B EN61000-3-2,3, FCC PART 15 / CISPR22 class B, CNS13438 class B, , GB9254, GB17625.1
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
EMC IMMUNITY
EMC EMISSION
See page 3 ; Other type available by customer requested
See page 3 ; Other type available by customer requested
80mVp-p
85 ~ 264VAC
0.5A / 115VAC 0.3A / 230VAC
35A / 115VAC 65A / 230VAC
110 ~ 140% rated output voltage
1000ms, 30ms, 50ms/230VAC 1500ms, 30ms, 15ms/115VAC at full load
VOLTAGE RANGE Note.7
81% 85% 85% 86% 87% 88% 88% 88.5% 89%