NUMBER GS-12-500 TYPE PRODUCT SPECIFICATION
TITLE PAGE REVISION
Universal Contact
1 of 9 J
AUTHORIZED BY DATE
A
ndy Lu 11-Sept-14
CLASSIFICATION
UNRESTRICTED
Copyright FCI.
Form E-3701 – Revision C
GS-01-029
1.0 Objective
This specification defines the performance, test, quality and reliability requirements of the Universal Contact
product.
2.0 Scope
This specification is applicable to the termination characteristics of the Universal Contact family of products
which provides a means to electrically connect a device to a printed circuit board assembly.
3.0 Ratings
3.1 Operating Voltage Rating = 12V DC
3.2 Operating Current Rating = 2 Amps/pin (1 Amps/pin only for 10123973-00*RLF)
3.3 Operating Temperature Range = -40 ~+85
3.4 Storage Conditions
Well controlled storage conditions are a major factor in ensuring good product solderability. Do not
store products where their properties can be deteriorated by harmful gases or significant variations in
temperatures or humidity. In the storage facility, climatic conditions shall be according to IEC 60721-3-1,
class 1K2 are advised, with the following exceptions:
low relative humidity shall be 10%
high relative humidity shall be 75%
It is assumed that during storage the product is in the as-received shipping cartons or boxes from FCI;
(i.e, the shipping cartons or boxes have not been opened).
3.5 Shelf life
FCI Electronics Division recommends that the shelf life of solderable products be 30 months
following the date printed on the primary labels on the product packaging:
FCI Electronics division or Distributor partner storage may not exceed 24 months.
Storage at customer locations shall not exceed 6 months.
This is based upon solderabililty evaluations after storage under controlled environmental conditions.
4.0 Applicable Documents
4.1 FCI Specifications
Engineering drawings
10076429/10076430/10076431/10076432/10094594/10103955/10104319/10104320/10104321/10115
748/10123973/10125000/10128200/10128875
4.2 National or International Standards
EIA 364: Electrical Connector/Socket Test Procedures Including Environmental Classifications.
4.3 FCI Laboratory Reports - Supporting Data
P08058, P08136, DL-2009-10-013, P09125, DL-2011-12-011, DL-2013-03-045, DL-2013-06-020,
DL-2013-12-035,DL-2014--07-014
5.0 Requirements
5.1 Qualification
PDS: Rev :J STATUS:Released Printed: Sep 15, 2014
NUMBER GS-12-500 TYPE PRODUCT SPECIFICATION
TITLE PAGE REVISION
Universal Contact
2 of 9 J
AUTHORIZED BY DATE
A
ndy Lu 11-Sept-14
CLASSIFICATION
UNRESTRICTED
Copyright FCI.
Form E-3701 – Revision C
GS-01-029
Connectors furnished under this specification shall be capable of meeting the qualification test
requirements specified herein.
5.2 Material
Contact: Copper Alloy or Stainless Steel.
5.3 Finish
Contact Plating:
Contact area: Plating shall be gold or GXT or Tin over Ni underplate.
Solder tail: Plating shall be gold flash or Tin over Ni underplate.
5.4 Design and Construction
5.4.1 Mechanical configuration dimensions.
Split type Universal Contact Compact Dimensions in mm
Part Number A B C D E F
G
(pick and place
nozzle location)
Working
Height
10076429-
00*RLF
2.50
±0.10
4.87
±0.15
0.98
±0.10
1.40
±0.10
1.19
±0.20 0.74 min 2.8 Ref. 1.55
±0.10
10076431-
00*RLF
1.3
±0.10
3.48
±0.10
1.10
±0.10
0.77
±0.10
0.80
±0.20 0.30 min 2.5 Ref. 0.92
±0.10
10076432-
00*RLF
3.50
±0.10
5.00
±0.13
1.10
±0.10
2.00
±0.10
1.65
±0.20 0.50 min 3.4Ref. 2.20
±0.10
PDS: Rev :J STATUS:Released Printed: Sep 15, 2014
NUMBER GS-12-500 TYPE PRODUCT SPECIFICATION
TITLE PAGE REVISION
Universal Contact
3 of 9 J
AUTHORIZED BY DATE
A
ndy Lu 11-Sept-14
CLASSIFICATION
UNRESTRICTED
Copyright FCI.
Form E-3701 – Revision C
GS-01-029
Solid type Universal Contact Compact Dimension in MM
Part Number A B C C1 D E F
G
(pick and place
nozzle location)
Working
Height
10076430-
00*RLF
1.8
±0.10
3.40
±0.13
0.90
±0.10
1.10
±0.10
1.00
±0.10
0.84
±0.20
0.47
min 2.7 Ref. 1.10
±0.10
10094594-
00*RLF
1.30
±0.10
3.48
±0.10
1.40
±0.10
1.50
±0.10
0.77
±0.10
0.80
±0.20
0.30
min 2.5 Ref. 1.00
±0.10
10103955-
00*RLF
1.8
±0.10
3.40
±0.13
0.90
±0.10
1.10
±0.10
0.95
±0.10
0.84
±0.20
0.47
min 2.7 Ref. 1.10
±0.10
10104319-
00*RLF
2.50
±0.10
4.87
±0.15
0.98
±0.10
1.28
±0.10
1.40
±0.10
1.19
±0.20
0.74
min 2.8 Ref. 1.55
±0.10
10104320-
00*RLF
1.3
±0.10
3.48
±0.10
1.10
±0.10
1.30
±0.10
0.72
±0.10
0.80
±0.20
0.30
min 2.5 Ref. 1.00
±0.10
10104321-
00*RLF
3.50
±0.10
5.00
±0.13
1.10
±0.10
1.40
±0.10
2.00
±0.10
1.65
±0.20
0.50
min 3.4 Ref. 2.20
±0.10
10115748-
00*RLF
1.55
±0.10
3.48
±0.10
1.40
±0.10
1.50
±0.10
0.87
±0.10
0.80
±0.20
0.30
min 2.5 Ref. 1.02
±0.10
10123973-
00*RLF
1.20+
0.15/-0
2.60
±0.10
1.10
±0.10
/ 0.40
±0.05
0.32
±0.10
0.15
min 1.75 Ref. 0.50
±0.05
10125000-
00*RLF
2.1
±0.10
3.40
±0.13
1.10
±0.10
1.20
±0.13
1.20
±0.10
0.90
±0.20
0.30
min 2.2 Ref. 1.60
±0.05
10128200-
00*RLF
2.1
±0.10
3.40
±0.13
1.10
±0.10
1.20
±0.13
1.25
±0.10
0.90
±0.20
0.30
min 2.2 Ref. 1.60
±0.05
10128875-
00*RLF
4.10
±0.10
5.00
±0.13
1.10
±0.10
1.40
±0.10
2.30
±0.10
1.65
±0.20
0.40
min 3.4 Ref. 2.50
±0.10
Note: *: plating code, refer to product drawing,
* in below table has the same meaning
PDS: Rev :J STATUS:Released Printed: Sep 15, 2014
NUMBER GS-12-500 TYPE PRODUCT SPECIFICATION
TITLE PAGE REVISION
Universal Contact
4 of 9 J
AUTHORIZED BY DATE
A
ndy Lu 11-Sept-14
CLASSIFICATION
UNRESTRICTED
Copyright FCI.
Form E-3701 – Revision C
GS-01-029
5.4.2 Pad Geometry and Dimension:
5.4.2.1 Pad Geometry:
5.4.2.2 Pad Geometry Dimension (unit: mm):
Part Number G H I J K
10076429-
00*RLF 0.10 1.35 3.76 5.50 1.00
10076430-
00*RLF 0.10 1.25 2.75 3.90 0.90
10076431-
00*RLF 0.10 1.45 2.45 4.00 1.10
10076432-
00*RLF 0.10 1.45 3.65 5.50 1.10
10094594-
00*RLF 0.10 1.85 2.45 4.00 1.10
10103955-
00*RLF 0.10 1.25 2.75 3.90 0.90
10104319-
00*RLF 0.10 1.35 3.76 5.50 1.00
10104320-
00*RLF 0.10 1.45 2.45 4.00 1.10
PDS: Rev :J STATUS:Released Printed: Sep 15, 2014
NUMBER GS-12-500 TYPE PRODUCT SPECIFICATION
TITLE PAGE REVISION
Universal Contact
5 of 9 J
AUTHORIZED BY DATE
A
ndy Lu 11-Sept-14
CLASSIFICATION
UNRESTRICTED
Copyright FCI.
Form E-3701 – Revision C
GS-01-029
10104321-
00*RLF 0.10 1.45 3.65 5.50 1.10
10115748-
00*RLF 0.10 1.85 2.45 4.00 1.10
10123973-
00*RLF 0.10 1.45 2.50 3.20 1.10
10125000-
00*RLF 0.10 1.45 2.50 4.00 1.10
10128200-
00*RLF 0.10 1.45 2.50 4.00 1.10
10128875-
00*RLF 0.10 1.55 3.00 5.60 1.20
6.0 Electrical Characteristics
6.1 Contact Resistance, Low Level (LLCR)
The low level contact resistance shall not exceed 20 milliohms (50 milliohms for 10123973-00*RLF).
Measurements shall be in accordance with or EIA 364-23.
The following details shall apply:
a. Test Voltage - 20 milli-volts DC max open circuit.
b. Test Current - Not to exceed 100 milli-amperes.
6.2 Current Rating
The temperature rise above ambient shall not exceed 30 at any point in the system when one
contact is powered at 2 amperes (1 Amps for 10123973-00*RLF).
a. Reference - EIA 364-70
7.0 Mechanical Characteristics
7.1 Normal Force (All data after 3 X reflow cycles)
The following details shall apply:
a. Cross Head Speed – 25.4 mm per minute.
b. Utilize free floating fixtures.
c. Reference –EIA 364-13.
Table 1 Split type Universal Contacts
Part Number
Pre-load
Apply
Load(N)
Pre-load
Un-Applying
load(N)
Max
deflection
(mm)
Minimal Normal
Force @ max
Deflection (N)
Spring
Rate(N/mm)
10076429-
00*RLF 0.28 0.20 0.93 0.50 0.34
10076431-
00*RLF 0.30 0.20 0.40 0.58 0.90
10076432-
00*RLF 0.40 0.30 1.30 0.98 0.53
PDS: Rev :J STATUS:Released Printed: Sep 15, 2014
NUMBER GS-12-500 TYPE PRODUCT SPECIFICATION
TITLE PAGE REVISION
Universal Contact
6 of 9 J
AUTHORIZED BY DATE
A
ndy Lu 11-Sept-14
CLASSIFICATION
UNRESTRICTED
Copyright FCI.
Form E-3701 – Revision C
GS-01-029
Table 2 Solid type Universal Contacts
Part Number
Pre-load
Apply
Load(N)
Pre-load
Un-Applying
load(N)
Max
Deflection
(mm)
Minimal Normal
Force @ max
Deflection(N)
Spring
Rate(N/mm)
10076430-00*RLF 0.50 0.38 0.65 0.70 0.86
10094594-00*RLF 0.78 0.58 0.32 0.87 1.20
10103955-00*RLF 0.35 0.15 0.80 0.75 0.74
10104319-00*RLF 0.42 0.31 1.00 0.54 0.32
10104320-00*RLF 0.41 0.36 0.40 0.70 1.50
10104321-00*RLF 0.56 0.38 1.30 1.02 0.49
10115748-00*RLF 0.44 0.26 0.60 0.73 0.78
10123973-00*RLF / / 0.65 0.60 0.92
10125000-00*RLF 0.50 0.36 0.45 0.60 0.67
10128200-00*RLF 0.50 0.36 0.45 0.60 0.67
10128875-00*RLF 0.35 0.31 1.60 0.66 0.30
The normal force of 10094594-001RLF needs to be 0.7N Min. at 0.15mm deflection
PDS: Rev :J STATUS:Released Printed: Sep 15, 2014
NUMBER GS-12-500 TYPE PRODUCT SPECIFICATION
TITLE PAGE REVISION
Universal Contact
7 of 9 J
AUTHORIZED BY DATE
A
ndy Lu 11-Sept-14
CLASSIFICATION
UNRESTRICTED
Copyright FCI.
Form E-3701 – Revision C
GS-01-029
The normal force of 10104319-001RLF needs to be 0.4N Min. at 0.4mm deflection
7. 2 Durability (Minimum): Mated 100 times and still meet electrical characteristics in section 6.1
Note: Can achieve 2500 times when mated with a PCB pad with 0.05/0.15um Au, no breakdown.
- EIA 364-09
7. 3 GXT Plating Coating Adhesion Test: refer to FDQWI-PP-0000-P05 (test method).
8.0 Environmental Conditions
After exposure to the following environmental conditions i accordance with the specified test procedure
and/or details, the product shall show no physical damage and shall meet the electrical and mechanical
requirements per paragraphs 6.0 and 7.0 as specified in the Table test sequences. Unless specified
otherwise, assemblies shall be mated during exposure.
8. 1 Thermal Shock – EIA 364-32.
a. Number of Cycles - 32
b. Temperature Range - Between -40 and +85
c. Time at Each Temperature - 30 minutes
d. Transfer Time – 20 seconds, maximum
8. 2 Humidity –EIA 364-31 method II (steady state)
a. Relative Humidity – 90~95%
b. Temperature 40±2
c. Duration - 96 hours
8. 3 Salt Spray – EIA-364-26
a. Test Condition – Temperature: 35±2, NaCl solution Concentration: 5±1%
b. Duration - 48 hours
8. 4 Solderability – J-STD-002
a. Test Condition - Immersion
b. Minimum solder coverage: 95%
9.0 QUALITY ASSURANCE PROVISIONS
9.1 Equipment Calibration
All test equipment and inspection facilities used in the performance of any test shall be maintained in a
calibration system in accordance with ANSI Z-540 and ISO 9000.
9.2 Inspection Conditions
Unless otherwise specified herein, all inspections shall be performed under the following ambient
conditions:
a. Temperature: 25 +/- 5
b. Relative Humidity: 30% to 60%
c. Barometric Pressure: Local ambient
PDS: Rev :J STATUS:Released Printed: Sep 15, 2014
NUMBER GS-12-500 TYPE PRODUCT SPECIFICATION
TITLE PAGE REVISION
Universal Contact
8 of 9 J
AUTHORIZED BY DATE
A
ndy Lu 11-Sept-14
CLASSIFICATION
UNRESTRICTED
Copyright FCI.
Form E-3701 – Revision C
GS-01-029
9.3 Acceptance
9.3.1 Electrical and mechanical requirements placed on test samples as indicated in paragraphs 6.0
and 7.0 shall be established from test data using appropriate statistical techniques or shall otherwise
be customer specified, and all samples tested in accordance with this product specification shall meet
the stated requirements.
9.3.2 Failures attributed to equipment, test setup, or operator error shall not disqualify the product. If
product failure occurs, corrective action shall be taken and samples resubmitted for qualification.
9.4 Qualification Testing
Qualification testing shall be performed on sample units produced with equipment and procedures
normally used in production. The test sequences shall be as shown in the qualification test table. Data
shall be provided with the samples noting production history: production lot codes for components and
assemblies, components and assemblies produced to print revision, verification of plating composition
and thickness, etc.
9.5 Re-Qualification Testing
If any of the following conditions occur, the responsible product engineer shall initiate requalification
testing consisting of all applicable parts of the qualification test matrix.
a. A significant design change is made to the existing product which impacts the product form, fit or
function. Examples of significant changes shall include, but not be limited to, changes in the plating
material composition or thickness, contact force, contact surface geometry, insulator design, contact
base material, or contact lubrication requirements.
b. A significant change is made to the manufacturing process which impacts the product form, fit or
function.
c. A significant event occurs during production or end use requiring corrective action to be taken
relative to the product design or manufacturing process.
9.6 Qualification Test Table and Sample Quantity.
Test Items Test
method
TEST SEQUENCE
Group1 Group2 Group3 Group4
Examination of product 1,6 1,5 1,6 1,3
Contact Resistance 6.1 2,5 2,4 2,5
Normal force 7.1 3
Durability 7.2 4
Salt Spray 8.3 3
Thermal Shock 8.1 3
Humidity 8.2 4
Solderability test 8.4 2
Sample Quantity 5 5 5 5
10.0 PACKAGING SPECIFICATION
Refer to FCI specification GS-14-1216.
PDS: Rev :J STATUS:Released Printed: Sep 15, 2014
NUMBER GS-12-500 TYPE PRODUCT SPECIFICATION
TITLE PAGE REVISION
Universal Contact
9 of 9 J
AUTHORIZED BY DATE
A
ndy Lu 11-Sept-14
CLASSIFICATION
UNRESTRICTED
Copyright FCI.
Form E-3701 – Revision C
GS-01-029
REVISION RECORD
Rev Page Description EC# Date
A All PRELIMINARY DG07-0366 2007-07-09
B All ADD Y01,Y04 SPEC IN THE SPEC DG08-0055 2008-03-10
C All MODIFY THE CPN AND ADD THE PAD GEOMETRY DG08-0254 2008-09-11
D All ADD Y05 IN SPEC DG09-0056 2009-05-05
E All ADD Y06 IN SPEC DG09-0331 2009-08-20
F All ADD THREE NEW P/Ns IN SPEC DG10-0291 2009-11-20
G All ADD NEW P/N IN SPEC DG12-0086 2010-08-11
H All ADD NEW P/N(F01) INTO SPEC AND CHANGE FORMAT ELX-DG-011189-1 2012-04-01
J All ADD NEW P/N INTO SPEC ELX-DG-18794-1 2014-09-11
PDS: Rev :J STATUS:Released Printed: Sep 15, 2014
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
FCI / Amphenol:
10103955-009RLF 10104320-009RLF 10104321-009RLF 10115748-009RLF 10104319-009RLF