182
High-sensitivity Relays
Rated voltage 1.5 VDC 3 VDC 5 VDC 6 VDC 9 VDC 12 VDC 24 VDC
Rated current 125 mA 66.7 mA 41.7 mA 33.3 mA 22.5 mA 17.1 mA 8.6 mA
Coil resistance 12 Ω45 Ω120 Ω180 Ω400 Ω700 Ω2,800 Ω
Coil inductance Armature OFF
0.005 0.022 0.055 0.083 0.165 0.228 1.465
(H) (ref. value) Armature ON
0.009 0.035 0.092 0.129 0.303 0.504 2.287
Must operate voltage 80% max. of rated voltage
Must release voltage 10% min. of rated voltage
Max. voltage 140% of rated voltage at 23°C, 130% at 65°C
Power consumption Approx. 200 mW
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2. Operating characteristics are measured at a coil temperature of 23°C.
■ Contact Ratings
Item Single crossbar Bifurcated crossbar
Load Resistive load Resistive load
(cosø = 1) (cosø = 1)
Rated Load 0.5 A at 110 VAC; 0.5 A at 110 VAC;
1 A at 24 VDC 1 A at 24 VDC
Contact Material AgPd (Au-clad)
Rated Carry Current 2 A
Max. switching voltage 125 VAC, 60 VDC
Max. switching current 1 A
Max. switching power 120 VA, 30 W 120 VA, 30 W
Failure rate (reference value) 1 mA at 5 VDC 0.1 mA at 0.1 VDC
Note: P level: λ60 = 0.1 x 10-6/operation.
PCB Signal Relay – G2E
■ Characteristics
Contact resistance 50 mΩmax.
Operate time General-purpose type: 5 ms max. (mean value: approx. 2.5 ms)
.High-sensitivity type: 7 ms max. (mean value: approx. 3.5 ms)
Release time 3 ms max. (mean value: approx. 0.8 ms)
Max. switching frequency Mechanical: 18,000 operations/hr
Electrical: 1,800 operations/hr at rated load
Insulation resistance 100 MΩmin. (at 500 VDC)
Dielectric 500 VAC, 50/60 Hz for 1 min between coil and contacts
withstand voltage 500 VAC, 50/60 Hz for 1 min between contacts of same polarity
Vibration resistance Destruction: 10 to 55 to 10 Hz, 1.65mm single amplitude (3.3mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 1.65mm single amplitude (3.3mm double amplitude
Shock resistance Destruction: 1,000 m/s2 (approx. 100G)
Malfunction: 200 m/s2 (approx. 20G)
Endurance Mechanical: 10,000,000 operations min. (at 18,000 operations/hr)
Electrical: DC: 500,000 operations min. (1 A at 24 VDC resistive load)
AC: 200,000 operations min. (0.5 A at 110 VAC resistive load) (at 1,800 operations/hr)
Ambient temperature Operating: -25˚C to 60˚C (with no icing) (high-sensitivity type: -25°C to 65°C)
Ambient humidity Operating: 5% to 85%
Weight Approx. 3.7 g