www.carlingtech.com
M-Series
M-Series
CIRCUIT BREAKER
The M-Series is a low cost, miniature, hydraulic-magnetic circuit breaker which features a compact, space saving
design, front panel snap-in mounting and a vertically mounted parallel pole conguration. It features various
styling options to maximize your design exibility. Choices include rocker, illuminated rocker, paddle and
baton style handle actuators, push-to-reset and push-pull pushbutton actuators, as well as Visi-Rocker two color
actuators. Our exclusive Rockerguard bezel helps prevent inadvertent actuation and a wiping contact mechanism
assures long-term reliability.
The M-Series circuit breakers are available with 1, 2 or parallel poles, 0.02 to 50 amp ratings, and 125 and
250VAC or 80VDC versions. With over 16 different time delays, 5 terminal styles, a variety of panel hardware,
various colors, and legend imprinting, it assures suitability for most any application design.
Product Highlights:
Parallel pole conguration ts in one rack unit
MIL-PRF-55629
MIL STD 202 compliant
MIL-PRF-39019F ingress protection
Sealed toggle actuator
Compact design
Typical Applications:
Telecom/Datacom
Transportation
Marine
Generators
Power Supplies
Medical Equipment
Download 3D CAD Files
Resources:
IGS STP
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
2 |M-Series Circuit Breaker - General Specications
*Manufacturer reserves the right to change product specification without prior notice.
Environmental
Physical
MechanicalElectrical
Designed in accordance with requirements of specication
MIL PRF-55629 & MIL-STD-202G as follows:
Maximum Voltage 125/250 VAC 50/60 Hz, 80 VDC
(See Rating Tables.)
Current Ratings Standard current coils: 0.100,
0.250, 0.500, 0.750, 1.00 thru 15.0
in 1 amp increments, 18.0, 20.0,
25.0, 30.0. Other ratings available
- see Ordering Scheme.
Auxiliary Switch Rating SPDT; 7A 250VAC, 7A (Res)
28VDC, 4A (Ind.) 28VDC, 0.25A
80VDC (Res) (silver contacts),
0.1A 125VAC (gold contacts).
Insulation Resistance Minimum of 100 Megohms at 500
VDC.
Dielectric Strength UL, CSA 1500V, 50/60 Hz for one
minute between all electrically
isolated terminals. M-Series
Circuit Breakers comply with the
8mm spacing and 3750 V 50/60Hz
dielectric requirements from
hazardous voltage to operator
accessible surfaces, per
Publications IEC 380, 435, 950,
EN 60950 and VDE 0805.
Resistance, Impedance Values from Line to Load Terminal
- based on Series Trip Circuit
Breaker.
Endurance 10,000 ON-OFF operations @ 6
per minute with rated Current and
Voltage.
Trip Free All M-Series Circuit Breakers will
trip on overload, even when
actuator is forcibly held in the ON
position.
Trip Indication The actuator moves positively
to the OFF position when an
overload causes the circuit
breaker to trip.
Shock Withstands 100 Gs, 6ms, sawtooth
while carrying rated current per
Method 213, Cond. I. Instantaneous
curves tested at 80% of rated
current.
Vibration Withstands 0.060” excursion
from 10-55 Hz, and 10 Gs 55-500
Hz, at rated current per Method
204C, Test Condition A.
Instantaneous curves tested at
80% of rated current.
Moisture Resistance Method 106D, i.e., ten 24-hour
cycles @ + 25°C to +65°C, 80-
98% RH.
Salt Spray Method 101, Condition A (90-95%
RH @ 5% NaCl Solution, 96 hrs).
Thermal Shock Method 107D, Condition A (Five
cycles @ -55°C to +25°C to +85°C
to +25°C).
Operating Temperature -40° C to +85° C
Chemical Resistance Only the outside surfaces of the
case and the handles may be
cleaned with detergents or
alcohol. Organic (hydrocarbon
based) solvents are not
recommended because they
attack plastics. Caution should
be taken when solvents are used
to clean and remove ux from
terminals. Lubricants should not
be introduced into the handle/
bushing openings
Number of Poles 1 or 2
Internal Circuit Congs. Series with or without
Auxiliary Switch.
Switch Only with or without
Auxiliary Switch.
Weight Approximately 30 grams/pole
(Approximately 1.07 ounces/pole)
Standard Colors See Ordering Scheme
Pulse Tolerance Curves
RESISTANCE PER POLE VALUES
from Line to Load Terminals
(Values Based on Series Trip Circuit Breaker)
CURRENT
(AMPS)
TOLERANCE
(%)
0.10 - 20.0 ± 25
20.1 - 50.0 ± 35
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
| 3
M-Series Circuit Breaker - General Specications
Electrical Tables
Table A: Lists UL Recognized and CSA Accepted congurations & performance capabilities as a Component Supplementary
Protector.
Table B: Lists UL Recognized,CSA Accepted and TUV and VDE Certied congurations and performance capabilities as a
Component Supplementary Protector.
Notes:
1 Polarity Sensitive
2 Available only with Special Catalog Number. Consult Factory.
3 Requires Branch Circuit Backup with a UL Listed type K-5 or RK-5 fuse rated 30 Amps maximum
4 TUV only, not VDE
5 Requires backup protection with a thermal magnetic circuit breaker rated 32 amps and having a
Type C trip characteristic per EN60898/DIN VDE 0641 (C32A) for ratings greater than 15amps,
and a thermal magnetic circuit breaker rated 16 amps and having a Type C trip characteristic per
EN60898/DIN VDE 0641 (C16A) for ratings 15 amps and less
Notes:
1 Polarity Sensitive
2 Available only with Special Catalog Number. Consult Factory.
3 Requires Branch Circuit Backup with a UL Listed type K-5 or RK-5 fuse rated 30 Amps maximum
4 Requires Branch Circuit Backup with a UL Listed type K-5 or RK-5 fuse rated 60 Amps maximum
M-SERIES TABLE A: COMPONENT SUPPLEMENTARY PROTECTORS
Circuit
Conguration
Voltage Current Rating
Poles
Breaking
Short Circuit Capacity (Amps) Application Codes
Max
Rating Frequency Phase Full Load
Amps
General
Purpose Amps
UL / CSA
With Backup
Fuse
Without Backup
Fuse UL CSA
Series
32 DC --- 0.02 - 15 --- 1 --- 1000 TC1, 2, OL1, U1 TC1, 2, OL1, U1
--- 15.1 - 25 1 --- 1000 TC1, 2, OL0, U1 TC1, 2, OL0, U1
50 2DC --- 0.02 - 7.5 --- 1 --- 1000 TC1, 2, OL0, U1 TC1, 2, OL0, U1
65 DC --- 0.02 - 15 --- 2 --- 1000 TC1, 2, OL1, U1 TC1, 2, OL1, U1
--- 15.1 - 25 2 --- 1000 TC1, 2, OL0, U1 TC1, 2, OL0, U1
65 1,2 DC --- 0.02 - 15 --- 1 --- 1000 TC1, 2, OL1, U1 TC1, 2, OL1, U1
--- 15.1 - 30 1 --- 1000 TC1, 2, OL0, U1 TC1, 2, OL0, U1
65 DC --- 0.02 - 15 --- 2 5000 3--- TC1, 2, OL1, C1 TC1, 2, OL1, C1
--- 15.1 - 25 2 5000 3--- TC1, 2, OL0, C1 TC1, 2, OL0, C1
80 1DC --- 0.02 - 15 --- 1 --- 600 TC1, 2, OL1, U1 TC1, 2, OL1, U1
--- 15.1 - 30 1 --- 600 TC1, 2, OL0, U1 TC1, 2, OL0, U1
125 50 / 60 1
0.02 - 15 --- 1 --- 1000 TC1, 2, OL1, U1 TC1, 2, OL1, U1
--- 15.1 - 30 1 --- 1000 TC1, 2, OL0, U1 TC1, 2, OL0, U1
1  30 --- 1 --- 360 TC1, OL1, U2 TC3, OL1, U3
250 250 / 60 1 0.02 - 12 --- 1 --- 1000 TC1, 2, OL1, U1 TC1, 2, OL1, U1
250 50 / 60 1 --- 12.1 - 18 1 1000 4--- TC1, 2, OL0, C1 TC1, 2, OL0, C1
250 50 / 60 1
0.02 - 15 --- 2 --- 1000 TC1, 2, OL1, U1 TC1, 2, OL1, U1
--- 15.1 - 30 2 --- 1000 TC1, 2, OL0, U1 TC1, 2, OL0, U1
1  30 --- 2 --- 360 TC1, OL1, U2 TC3, OL1, U3
M-SERIES TABLE B: COMPONENT SUPPLEMENTARY PROTECTORS
Circuit
Conguration
Voltage Current Rating
Poles
Breaking
Short Circuit Capacity (Amps) Application Codes
Max
Rating Frequency Phase Full Load
Amps
General
Purpose
Amps
UL / CSA VDE / TUV
With
Backup
Fuse
Without
Backup
Fuse
With
Backup
Fuse
Without
Backup
Fuse
UL CSA
Series
32 DC --- 0.02 - 15 --- 1 --- 1000 3000 500 TC1, 2, OL1, U1 TC1, 2, OL1, U1
--- 15.1 - 25 1 --- 1000 3000 500 TC1, 2, OL0, U1 TC1, 2, OL0, U1
50 2DC --- 0.02 - 7.5 --- 1 --- 1000 3000 500 TC1, 2, OL0, U1 TC1, 2, OL0, U1
65 DC --- 0.02 - 15 --- 2 --- 1000 3000 500 TC1, 2, OL1, U1 TC1, 2, OL1, U1
--- 15.1 - 25 2 --- 1000 3000 500 TC1, 2, OL0, U1 TC1, 2, OL0, U1
65 3DC --- 0.02 - 15 --- 2 5000 --- 3000 500 TC1, 2, OL1, C1 TC1, 2, OL1, C1
--- 15.1 - 30 2 5000 --- 3000 500 TC1, 2, OL0, C1 TC1, 2, OL0, C1
80 1DC --- 0.02 - 15 --- 1 --- 600 4--- 500 TC1, 2, OL1, U1 TC1, 2, OL1, U1
--- 15.1 - 30 1 --- 600 4--- 500 TC1, 2, OL0, U1 TC1, 2, OL0, U1
125 50 / 60 1 0.02 - 15 --- 1 --- 1000 3000 500 TC1, 2, OL1, U1 TC1, 2, OL1, U1
1  15 --- 1 --- 360 3000 500 TC1, OL1, U2 TC3, OL1, U3
250 50 / 60 1
0.02 - 12 --- 1 --- 1000 3000 500 TC1, 2, OL1, U1 TC1, 2, OL1, U1
0.02 - 20 --- 2 --- 1000 3000 500 TC1, 2, OL0, U1 TC1, 2, OL0, U1
1  12 --- 1 --- 360 3000 500 TC1, OL1, U2 TC3, OL1, U3
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
4 |M-Series Circuit Breaker - General Specications
Electrical Tables
Table C: Lists UL489A Listed and TUV Certied congurations and performance capabilities for use in Communications
Equipment.
Table D: Lists UL489A Listed congurations and performance capabilities for use in Communications Equipment.
Notes:
1. Available only with Special Catalog Number
Notes:
1. Available only with Special Catalog Number
Agency Certifications
UL Recognized
UL Standard 1077
UL Listed
UL Standard 489A
CSA Accepted
VDE Certied
TUV Certied
Component Recognition Program
as Protectors, Supplementary
(Guide CCN/QVNU2, File E75596)
Communications Equipment
(Guide CCN/DITT, File E189195)
Component Supplementary
Protector (Class 3215 30, File
047848 0 000)
CSA Standard C22.2 No. 235
EN60934, VDE 0642 under File
10537
EN60934, under License No.
R9671109
M-SERIES TABLE C: UL489A Listed
(Communications Equipment - Polarity Sensitive)
Circuit
Conguration
Voltage Current Rating
General Purpose
Amps
Poles
Breaking
Interrupting Capacity (Amps)
Max
Rating Frequency
Without Backup Fuse
UL489A TUV
Series
80 DC 0.02 - 30 1 600 ---
65 1DC 0.02 - 30 1 1000 ---
80 DC 0.10 - 30 1 600 600
M-SERIES TABLE D: Parallel Pole Construction UL489A Listed
(Communications Equipment - Polarity Sensitive)
Circuit
Conguration
Voltage Current Rating
General Purpose
Amps
Poles
Breaking
Interrupting Capacity (Amps)
Max
Rating Frequency Without Backup Fuse
UL489A
Series 80 DC 31 - 50 2 600
65 1DC 31 - 50 2 1000
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
| 5
M-Series Circuit Breaker - Parallel Pole Rocker - Ordering Scheme
1
Series
2
Actuator
3
Poles
6
Current
Rating
7
Terminal
8
Illumination
12
Agency
Approval
4
Circuit
5
Frequency
& Delay
M E P A5 22 1 TB
D2 650
1 SERIES
M
7 TERMINAL
A Push in Stud
5 10-32 Screw (Bus Type)
3 POLES
2 Two
4 CIRCUIT/AUXILIARY SWITCH 2
P Series Trip Current (Parallel Pole)
with Auxiliary Switch, Silver Contacts
Q Series Trip Current (Parallel Pole) .110 x 0.20 Q.C
with Auxiliary Switch, Gold Contacts
R Series Trip Current (Parallel Pole) .110 x 0.20 Q.C
5 FREQUENCY & TIME DELAY
D2 DC Short
D4 DC Medium 12 AGENCY APPROVAL
T UL 489A Listed
11 BEZEL COLOR
A White without Rockerguard
B Black without Rockerguard
G Gray without Rockerguard
1 White with Rockerguard
2 Black with Rockerguard
7 Gray with Rockerguard
9
Actuator
Color &
Legend
10
Legend
11
Bezel
Color
8 ILLUMINATION
Non-Illuminated
A Non-Illuminated
9 ACTUATOR COLOR & LEGEND
Actuator Visi 1 Legend
1 White Black
2 Black White
3 Red White
4 Green White
5 Blue White
6 Yellow Black
7 Gray Black
8 Orange Black
10 LEGEND
2 ON - OFF Vertical
3 ON - OFF Horizontal
6 Dual Vertical
7 Dual Horizontal
2 ACTUATOR
Single Color Two Color Visi Single Color Translucent
A Angled D Indicate ON F Angled
B Flat E Indicate OFF G Flat
Notes:
1 Reminder of Rocker same color as Visi
2 Aux Switch only available with screw terminals
6 CURRENT RATING (AMPERES)
CODE AMPERES
631 31.000
635 35.000
640 40.000
645 45.000
650 50.000
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
6 |M-Series Circuit Breaker - Parallel Pole - Handle / Push Button - Ordering Scheme
6 CURRENT RATING (AMPERES)
CODE AMPERES
631 31.000
635 35.000
640 40.000
645 45.000
650 50.000
1 SERIES
M
7 TERMINAL
A Push in Stud
5 10-32 Screw (Bus Type)
3 POLES
2 Two
4 CIRCUIT/AUXILIARY SWITCH 1
P Series Trip Current (Parallel Pole)
with Auxiliary Switch, Silver Contacts
Q Series Trip Current (Parallel Pole) .110 x 0.20 Q.C
with Auxiliary Switch, Gold Contacts
R Series Trip Current (Parallel Pole) .110 x 0.20 Q.C
5 FREQUENCY & TIME DELAY
D2 DC Short
D4 DC Medium
12 AGENCY APPROVAL
T UL 489A Listed
11 BUSHING COLOR
B Black
9 FRONT PANEL HARDWARE
Handle
A No outer Panel Hardware
B Knurled Nut, Bright Nickel
C Knurled Nut, Bright Nickel with Locking Ring
D Knurled Nut, Black
E Knurled Nut, Black with Locking Ring
F Panel Dress, Bright Nickel
G Panel Dress, Bright Nickel with Locking Ring
H Panel Dress, Black
J Panel Dress, Black with Locking Ring
Push Button
1 No outer Panel Hardware
2 Knurled Nut, Bright Nickel
10 LEGEND PLATE / BUTTON MARKING
Handle Actuator Legend Plate
B ON - OFF Vertical
C ON - OFF Horizontal
Push-Pull Actuator Legend Plate
2 Rated Amps Horizontal
3 Rated Amps Line Side Down
4 Rated Amps Line Side Up
2 ACTUATOR
M Paddle
T Push-Pull
8 ACTUATOR COLOR & LEGEND
Handle Push Button
1 White A White
2 Black B Black
3 Red C Red
4 Green D Green
5 Blue E Blue
6 Yellow F Yellow
7 Gray G Gray
8 Orange H Orange
Notes:
1 Aux Switch only available with screw terminals
1
Series
2
Actuator
3
Poles
6
Current
Rating
7
Terminal
8
Actuator
Color
12
Agency
Approval
4
Circuit
5
Frequency
& Delay
M M P 15 B2 B TB
D2 650
9
Front
Panel
Hardware
10
Legend
Plate/
Marking
11
Brushing
Color
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
| 7
M-Series Circuit Breaker - Parallel Pole - Dimensional Specications
1.304[33.12]
1.125[28.58]
.970[24.64]
1.375[34.93]
1.125[28.58]
1.560[39.62]
.370[9.40]MAX.
INDICATE"OFF"(VISI-OFF)
&SINGLE COLOR
ON
OFF
.400[10.16]
ON
OFF
±.020±.508
1.050[26.67]
ON
PANEL CUT - OUT DETAIL (ROCKER)
.125[3.18]
PANEL
THICKNESS
.093[2.36]
.062[1.57]
OFF
1.139[33.76]
DOUBLEPOLE
DIM. A
±.005±.13
LINE
DIM. A
1.460[37.08]
+.005 +.13
-.000 -.00
1.420[36.07]
1.385[35.18]
ROCKERGUARDCONFIGURATION
.675[17.14]
.100[2.54]
LOAD
±.020±.508.305[7.75]
±.020±.508
PUSH-IN STUD
1.000[25.4]
.750[19.05]
.100[2.54]
1.394[35.41]
.393[9.97]
1.000[25.4]
.154[3.91]
ROCKERACTUATOR DETAIL
1.530[38.86]
INDICATE"ON" (VISI-ON)
±.020[±.508]±.020[±.508]
.652[16.56]
.838[21.29]
PARALLEL POLE TERMINALOPTIONS
.912[23.16]
10-32 SCREW W/ BUS BAR
MSERIESPARALLEL POLE
FORM&FIT DIAGRAMS
NOTES:
1. ALLDIMENSIONSARE IN INCHES[MILLIMETERS].
2. TOLERANCE±.010[.25]UNLESSOTHERWISESPECIFIED.
3. DIMENSIONSAPPLY TO BOTH ROCKERSTYLES.
4. I-O,ON-OFF OR DUALLEGENDSAVAILABLE FOR
VERTICAL OR HORIZONTALMOUNTING.
5. NOTICE THATCIRCUITBREAKERLINEANDLOADTERMINAL
ORIENTATION ON INDICATE"OFF"ISOPPOSITETHAT OF
INDICATE"ON".
ME
5/10/12
LINE
DR BY
TITLE
.625[15.88]
LOAD
LOAD
DWG NO
SHT OF
CLA-8121
APVD BY
1 3
REV
A
LINE
REVISIONS
RELEASEDPER
ECO16976
LET
A
DATE
5-10-12
Dimensional Specifications: in. [mm]
Notes:
1 All dimensions are in inches [millimeters].
2 Tolerance ±.010 [.25] unless otherwise specied.
3 Dimensions apply to both rocker styles.
4 I-o, on-off or dual legends available for vertical or horizontal mounting.
5 Notice that circuit breaker line and load terminal orientation on indicate “off” is opposite that of indicate “on”.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
8 |M-Series Circuit Breaker - Parallel Pole - Dimensional Specications
.105[2.67]
.125[3.18]
HEXNUT
.625[15.88]
KNURLED NUT
.683 DIA [Ø17.27]
PANELDRESSNUT
LEGEND PLATES
.680 DIA [Ø17.27]
.632 DIA [Ø16.05]
.680 DIA [Ø17.27]
.180[4.57]
.340[8.64]
B
0N
0FF
.025[.64]
LEGEND
CODE:
PANEL HARDWARE
1.025[26.04]O
N
C
O
F
F
.125[3.18]
.470[11.94]
FLAT
.500[12.70]
.222[5.64]
.500 DIA [Ø12.70]
WITHOUTLOCKINGRING
±.002[±.050]
.125 DIA [Ø3.18]
.500 DIA [Ø12.70]
WITHLOCKINGRING
.355[9.02]
±.005[±.13]
+.010
-.000
+.25
-.000
+.010
-.000
MOUNTING DETAILS
+.25
-.000
±.030±.76
+.25
-.000
+.010
-.000
PADDLE ACTUATOR STYLE
1.395
12°
1/2-32THD.
12°
ON
OFF
MSERIESPARALLEL POLE
FORM&FIT DIAGRAMS
NOTES:
1. ALLDIMENSIONSARE IN INCHES[MILLIMETERS].
2. TOLERANCE±.010[.25]UNLESSOTHERWISESPECIFIED.
3. DIMENSIONSAPPLY TO BOTH ROCKERSTYLES.
4. I-O,ON-OFF OR DUALLEGENDSAVAILABLE FOR
VERTICAL OR HORIZONTALMOUNTING.
5. NOTICE THATCIRCUITBREAKERLINEANDLOADTERMINAL
ORIENTATION ON INDICATE"OFF"ISOPPOSITETHAT OF
INDICATE"ON".
ME
5/10/12
.031[.79]
LOCKINGRING
DR BY
TITLE
.342[8.69]
2 3
APVD BY DWG NO
SHT OF
CLA-8121
REV
A
REVISIONS
RELEASEDPER
ECO16976
LET
A
DATE
5-10-12
.435[11.05]DIA
PANELDRESSNUT
PANEL HARDWARE
HEX NUT
.156
[3.56]
.534
[13.56]
20 20
2
LINE
MARKING
CODE:
20
BUTTON MARKING ORIENTATION
.110QC AUXILIARY SWITCH TERMINALS
LINE
3 4
LINE
SNAP-INBUSHING
.162[4.11]
.625[15.87]DIA
MOUNTING DETAILS
.500[12.70]OFF(SHOWN).400[10.16]
±.002±.05
.280[7.11] ON
±.030±.76
PUSH-PULL,
PUSH TO RESET
.375[9.53]
DIA
.544[13.82]
.494
[12.55]
±.030±.76
PUSH-PULL ACTUATOR STYLE
±.030±.76
FLAT
1.484
3/8"8-32THD.
ACTUATORCOLOR
VISIBLE IN OFF
POSITIONONLY
NOTES:
1. ALLDIMENSIONSARE IN INCHES[MILLIMETERS].
2. TOLERANCE±.010[.25]UNLESSOTHERWISESPECIFIED.
3. DIMENSIONSAPPLY TO BOTH ROCKERSTYLES.
4. I-O,ON-OFF OR DUALLEGENDSAVAILABLE FOR
VERTICAL OR HORIZONTALMOUNTING.
5. NOTICE THATCIRCUITBREAKERLINEANDLOADTERMINAL
ORIENTATION ON INDICATE"OFF"ISOPPOSITETHAT OF
INDICATE"ON".
ME
5/10/12
DR BY
TITLE
3 3
MSERIESPARALLEL POLE
FORM&FIT DIAGRAMS
APVD BY DWG NO
SHT OF
CLA-8121
REV
A
.098
[2.49]
.078
[1.98]
REVISIONS
RELEASEDPER
ECO16976
LET
A
DATE
5-10-12
+.010
-.000
+.25
-.00
Dimensional Specifications: in. [mm]
Notes:
1 All dimensions are in inches [millimeters].
2 Tolerance ±.010 [.25] unless otherwise specied.
3 Dimensions apply to both rocker styles.
4 I-o, on-off or dual legends available for vertical or horizontal mounting.
5 Notice that circuit breaker line and load terminal orientation on indicate “off” is opposite that of indicate “on”.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
| 9
M-Series Circuit Breaker - Handle/Pushbutton UL Recognized - Ordering Scheme
1 SERIES
M
7 TERMINAL
1 Push-On 0.250 Tab (Q.C.) A 11 Push-In Stud
2 10 Screw 8-32 with Upturned Lugs P 12 Printed Circuit Board
3 10 Screw 8-32 (Bus Type)
3 POLES
1 One 2 Two
4 CIRCUIT 2
without Auxiliary Switch
A Switch Only (no coil), Maintained Contacts
B Series Trip (Current)
with Auxiliary Switch, Silver Contacts Terminal Type:
M Series Trip (Current) Aux Switch .110 QC x .020 QC
P 3 Switch Only, Maintained Contacts .060 Dia, Round Solder Turret
Q 3,4 Switch Only, Maintained Contacts .058 Dia, Round Q.C.
R 3,13 Switch Only, Maintained Contacts .080 Dia x .020 Flat Q.C.
S 3 Series Trip (Current) .060 Dia, Round Solder Turret
T 3,4 Series Trip (Current) .058 Dia, Round Q.C.
U 3,13 Series Trip, Maintained Contacts .080 Dia x .020 Flat Q.C.
with Auxiliary Switch, Gold Contacts
2 3,4 Switch Only, Maintained Contacts .058 Dia, Round Q.C.
3 3,13 Switch Only, Maintained Contacts .080 Dia x .020 Flat Q.C.
4 3,4 Series Trip (Current) .058 Dia, Round Q.C.
5 3,13 Series Trip, Maintained Contacts .080 Dia x .020 Flat Q.C.
9 Series Trip (Current) Aux Switch .110 QC x .020 QC
5 FREQUENCY & DELAY
03 DC 50/60Hz, Switch Only 32 DC, 50/60Hz Short
10 DC Instantaneous 34 DC, 50/60Hz Medium
12 DC Short 62 50/60Hz Short, Hi-Inrush
14 DC Medium 64 50/60Hz Medium, Hi-Inrush
20 50/60Hz Instantaneous 72 DC, Short,Hi-Inrush
22 50/60Hz Short 74 DC,Medium, Hi-Inrush
24 50/60Hz Medium 92 DC, 50/60Hz Short, Hi-Inrush
30 DC, 50/60Hz Instantaneous 94 DC, 50/60Hz Medium, Hi-Inrush
9 FRONT PANEL HARDWARE 6
Handle Push-Button
No outer Panel Hardware A 1
Knurled Nut
Bright nickel B 2
Bright nickel with locking ring C
Black D
Black with locking ring E
Panel Dress Nut
Bright nickel F
Bright nickel with locking ring G
Black H
Black with locking ring J
10 LEGEND PLATE / BUTTON MARKING
Handle Actuator Legend Plate (Actuator Styles M & N)
A No Legend Plate
B ON - OFF Vertical
C ON - OFF Horizontal
D I - O Vertical
E I - O Horizontal
Push-Pull Actuator Button Cap (Actuator Styles T & V)
1 No Marking
2 Rated Amps Horizontal
3 Rated Amps Line Side Down
4 Rated Amps Line Side Up
Push-to-Reset Actuator Button (Actuator Styles U & W)
1 No Marking
2 ACTUATOR 1
Handle
M Paddle
Push Button
T Push-Pull
Push Button with
Snap-In Mounting
V Push-Pull
N Baton
U Push To Reset
W Push To Reset
Notes:
1 One actuator is located in the center of each multi-pole breaker. Actuator codes V & W
limited to single pole breakers only.
2 Switch Only circuits are not available with Push-To-Reset actuators. For Switch Only circuits,
select Current Coil Rating from the above chart:
3 One Auxiliary Switch is supplied per breaker. On two-pole breakers, standard Auxiliary
Switch mounting is in pole one. Auxiliary Switch option limited to Series Trip and Switch Only
circuits. Not available with back connect screw or push-in stud terminals.
4 Mates with AMP .058” diameter pin receptacles including 60983-1 (gold plated)
and 60983-2 (tin plated).
5 Actuator color is only visible in the OFF position on Push-Pull actuators.
6 All units except snap-in mounting have one hex nut installed on bushing for use behind
the panel.
7 Other colors available. Consult factory.
8 TUV 20A, VDE 15A. UL Recognized and CSA Accepted to 30 amps.
Screw Terminals or Push-in Stud recommended above 20 amps.
9 30 amp rating not available with delay’s 30, 32, 34, 92 or 94.
10 Screw Terminals are VDE certied only with use of ring terminal attached to wire.
11 Terminal code A available with circuit codes A & B only.
12 Printed circuit board available with UL recognized approval only.
13 Auxiliary switch (at Q.C.) available with UL recognized approvals only.
12 AGENCY APPROVAL 8
C UL Recognized & CSA Accepted
D VDE Certied, UL Recognized & CSA Accepted
E TUV Certied, UL Recognized & CSA Accepted
11 BUSHING COLOR 7
B Black
8 ACTUATOR COLOR & LEGEND 5
Gloss Handle Push-Button Actuator Color
1 A White
2 B Black
3 C Red
4 D Green
5 E Blue
6 F Yellow
8 H Orange
6 CURRENT RATING (AMPERES)
CODE AMPERES
020 0.020 225 0.250 420 2.000 710 10.500
025 0.025 230 0.300 522 2.250 611 11.000
030 0.030 235 0.350 425 2.500 711 11.500
035 0.035 240 0.400 527 2.750 612 12.000
040 0.040 245 0.450 430 3.000 712 12.500
045 0.045 250 0.500 435 3.500 613 13.000
050 0.050 255 0.550 440 4.000 614 14.000
055 0.055 260 0.600 445 4.500 615 15.000
060 0.060 265 0.650 450 5.000 616 16.000
065 0.065 270 0.700 455 5.500 617 17.000
070 0.070 275 0.750 460 6.000 618 18.000
075 0.075 280 0.800 465 6.500 620 20.000
080 0.080 285 0.850 470 7.000 622 22.000
085 0.085 290 0.900 475 7.500 624 24.000
090 0.090 295 0.950 480 8.000 625 25.000
090 0.095 410 1.000 485 8.500 630 30.000 9
210 0.100 512 1.250 490 9.000
215 0.150 415 1.500 495 9.500
220 0.200 517 1.750 610 10.000
Voltage Full Load Amp
Rating General Purpose Amps Tungsten Lamp
Rating Poles
Breaking
Max
Rating Frequency Phase Max
Amps
Choose
Current Coil
Rating Code
Max
Amps
Choose Current
Coil Rating Code
Max
Amps
Choose
Current Coil
Rating Code
32 DC -15 615 25 625 - - 1
50 DC - - - 7.5 Consult Factory - - 1
65 DC 115 615 25 625 - - 2
125 50/60Hz 1 15 615 25 625 15 615 1
250 50/60Hz 1 12 612 - - - 1
250 50/60Hz 1 15 615 25 625 - - 2
1
Series
2
Actuator
3
Poles
6
Current
Rating
7
Terminal
8
Actuator
Color
12
Agency
Approval
4
Circuit
5
Frequency
& Delay
M M B 11 B1 B BC34 260
9
Front Panel
Hardware
10
Legend
Plate
11
Bushing
Color
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
10 |M-Series Circuit Breaker - Handle/Pushbutton UL489A/UL Recognized – Ordering Scheme
3 POLES
1 One
4 CIRCUIT
without Auxiliary Switch
B Series Trip (Current)
with Auxiliary Switch, Silver Contacts Terminal Type:
M Series Trip (Current) Aux Switch .110 QC x .020 QC
S 3 Series Trip (Current) .060 Dia, Round Solder Turret
T 3,4 Series Trip (Current) .058 Dia, Round Q.C.
U 3,13 Series Trip, Maintained Contacts .080 Dia x .020 Flat Q.C.
with Auxiliary Switch, Gold Contacts
4 2,3 Series Trip (Current) .058 Dia, Round Q.C.
5 3,12 Series Trip, Maintained Contacts .080 Dia x .020 Flat Q.C.
9 Series Trip (Current) Aux Switch .110 QC x .020 QC
9 FRONT PANEL HARDWARE 6
Handle Push-Button
No outer Panel Hardware A 1
Knurled Nut
Bright nickel B 2
Bright nickel with locking ring C
Black D
Black with locking ring E
Panel Dress Nut
Bright nickel F
Bright nickel with locking ring G
Black H
Black with locking ring J
10 LEGEND PLATE / BUTTON MARKING
Handle Actuator Legend Plate (Actuator Styles M & N)
A No Legend Plate
B ON - OFF Vertical
C ON - OFF Horizontal
D I - O Vertical
E I - O Horizontal
Push-Pull Actuator Button Cap (Actuator Styles T & V)
1 8 No Marking
2 Rated Amps Horizontal
3 Rated Amps Line Side Down
4 Rated Amps Line Side Up
Push-to-Reset Actuator Button (Actuator Styles U & W)
1 8 No Marking
2 ACTUATOR 1
Handle
M Paddle
Push Button
T Push-Pull
Push Button with
Snap-In Mounting
V Push-Pull
N Baton
U 8 Push To Reset
W 8 Push To Reset
1 One actuator is located in the center of each multi-pole breaker. Actuator codes V & W limited
to single pole breakers only.
2 One Auxiliary Switch is supplied per breaker. On two-pole breakers, standard Auxiliary Switch
mounting is in pole one. Auxiliary Switch option limited to Series Trip and Switch Only circuits.
Not available with Back Connected Screw or Push-in Stud terminals.
3 Mates with AMP .058” diameter pin receptacles including 60983-1 (gold plated) and
60983-3 (tin plated).
4 Screw terminals or Push-in Stud recommended above 20 amps.
5 Actuator color is only visible in the OFF position on Push-Pull actuators.
6 All units have one hex nut installed on bushing for use behind the panel.
7 Other colors available. Consult factory.
8 Not available with UL489A Listed breakers.
9 UL Recognized, CSA Accepted and UL Listed to 30 amps.
10 Terminal code A available with circuit codes A & B only.
11 Printed circuit board available with UL recognized approval only.
12 Auxiliary switch (at Q.C.) available with UL recognized approvals only.
8 ACTUATOR COLOR & LEGEND 5
Gloss Handle Push-Button Actuator Color
1 A White
2 B Black
3 C Red
4 D Green
5 E Blue
6 F Yellow
8 H Orange
1 SERIES
M
12 AGENCY APPROVAL 9
J UL489A Listed, TUV Certied
M UL Recognized, CSA Accepted
N UL Recognized, TUV Certied
T UL489A Listed
11 BUSHING COLOR 7
B Black
5 FREQUENCY & DELAY
10 DC Instantaneous 72 DC, Short,Hi-Inrush
12 DC Short 74 DC,Medium, Hi-Inrush
14 DC Medium
7 TERMINAL 4
1 Push-On 0.250 Tab (Q.C.) A 10 Push-In Stud
2 Screw 8-32 with Upturned Lugs P 11 Printed Circuit Board
3 Screw 8-32 (Bus Type)
6 CURRENT RATING (AMPERES)
CODE AMPERES
020 0.020 225 0.250 420 2.000 710 10.500
025 0.025 230 0.300 522 2.250 611 11.000
030 0.030 235 0.350 425 2.500 711 11.500
035 0.035 240 0.400 527 2.750 612 12.000
040 0.040 245 0.450 430 3.000 712 12.500
045 0.045 250 0.500 435 3.500 613 13.000
050 0.050 255 0.550 440 4.000 614 14.000
055 0.055 260 0.600 445 4.500 615 15.000
060 0.060 265 0.650 450 5.000 616 16.000
065 0.065 270 0.700 455 5.500 617 17.000
070 0.070 275 0.750 460 6.000 618 18.000
075 0.075 280 0.800 465 6.500 620 20.000
080 0.080 285 0.850 470 7.000 622 22.000
085 0.085 290 0.900 475 7.500 624 24.000
090 0.090 295 0.950 480 8.000 625 25.000
090 0.095 410 1.000 485 8.500 630 30.000
210 0.100 512 1.250 490 9.000
215 0.150 415 1.500 495 9.500
220 0.200 517 1.750 610 10.000
1
Series
2
Actuator
3
Poles
6
Current
Rating
7
Terminal
8
Actuator
Color
12
Agency
Approval
4
Circuit
5
Frequency
& Delay
M M B 11 B1 B JB14 620
9
Front Panel
Hardware
10
Legend
Plate
11
Bushing
Color
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
| 11
M-Series Circuit Breaker - Handle – Circuit & Terminal Diagrams
Notes:
1 All dimensions are in inches [millimeters].
2 Tolerance ±.020 [.51] unless otherwise specied.
Circuit & Terminal Diagrams: in. [mm]
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
12 |M-Series Circuit Breaker - Handle – PC Terminal Diagrams
Notes:
1 All dimensions are in inches [millimeters].
2 Tolerance ±.020 [.51] unless otherwise specied.
PC Terminal Diagrams: in. [mm]
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
| 13
M-Series Circuit Breaker - Handle - Dimensional Specications
Dimensional Specifications: in. [mm]
Notes:
1 All dimensions are in inches [millimeters].
2 Tolerance ±.020 [.51] unless otherwise specied.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
14 |M-Series Circuit Breaker - Pushbutton – Circuit & Terminal Diagrams
Circuit & Terminal Diagrams: in. [mm]
Notes:
1 All dimensions are in inches [millimeters].
2 Tolerance ±.020 [.51] unless otherwise specied.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
| 15
M-Series Circuit Breaker - Pushbutton – Dimensional Specications
Dimensional Specifications: in. [mm]
Notes:
1 All dimensions are in inches [millimeters].
2 Tolerance ± 0.20 [.51] unless otherwise specied.
3 Available with Push-Pull or Push-to-Reset Actuators
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
16 |M-Series Circuit Breaker - Push-Pull – PC Terminal Diagrams
PC Terminal Diagrams: in. [mm]
Notes:
1 All dimensions are in inches [millimeters].
2 Tolerance ±.020 [.51] unless otherwise specied.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
| 17
M-Series Circuit Breaker - Rocker UL Recognized – Ordering Scheme
1 SERIES
M
11 BEZEL COLOR / STYLE 9
Color without Rockerguard with Rockerguard
White A 1
Black B 2
Gray G 7
8 ROCKER ILLUMINATION
Non-illuminated A
Neon 5 Neon Green Glow 8
without resistor, 120VAC/250VAC B C
LED 7, 8 Red Green Amber
without resistor D G K
with resistor, 4-8 VDC E H L
with resistor, 9-16 VDC F J M
9 ACTUATOR & LEGEND COLOR
Solid Color Actuator Legend
1 White Black
2 Black White
3 Red White
4 Green White
5 Blue White
6 Yellow Black
7 Gray Black
8 Orange Black
Visi-Rocker 6 Visi & Legend (remainder of rocker same color as bezel)
1 White
2 Black
3 Red
4 Green
5 Blue
6 Yellow
7 Gray
8 Orange
Illuminated 8 Actuator Legend
A Clear White
B Red Transparent White
C Green Transparent White
D Amber Transparent White
E Smoke Gray Transparent White
F White Translucent Black
10 LEGEND 11
1 No Legend
2 ON - OFF Vertical
3 ON - OFF Horizontal
4 I - O Vertical
5 I - O Horizontal
6 Dual Vertical
7 Dual Horizontal
2 ACTUATOR 1
Non-Illuminated Two Color illuminated
single color Visi-Rocker single color
A Angled D Indicate ON F Angled
B Flat E Indicate OFF G Flat
6 CURRENT RATING (AMPERES)
CODE AMPERES
020 0.020 225 0.250 420 2.000 710 10.500
025 0.025 230 0.300 522 2.250 611 11.000
030 0.030 235 0.350 425 2.500 711 11.500
035 0.035 240 0.400 527 2.750 612 12.000
040 0.040 245 0.450 430 3.000 712 12.500
045 0.045 250 0.500 435 3.500 613 13.000
050 0.050 255 0.550 440 4.000 614 14.000
055 0.055 260 0.600 445 4.500 615 15.000
060 0.060 265 0.650 450 5.000 616 16.000
065 0.065 270 0.700 455 5.500 617 17.000
070 0.070 275 0.750 460 6.000 618 18.000
075 0.075 280 0.800 465 6.500 620 20.000
080 0.080 285 0.850 470 7.000 622 22.000
085 0.085 290 0.900 475 7.500 624 24.000
090 0.090 295 0.950 480 8.000 625 25.000
090 0.095 410 1.000 485 8.500 63012 30.000
210 0.100 512 1.250 490 9.000
215 0.150 415 1.500 495 9.500
220 0.200 517 1.750 610 10.000
7 TERMINAL
1 Push-On 0.250 Tab (Q.C.) A 14 Push-In Stud
2 10 Screw 8-32 with Upturned Lugs P 15 Printed Circuit Board
3 10 Screw 8-32 (Bus Type)
3 POLES
1 One 2 Two
4 CIRCUIT 2
without Auxiliary Switch
A Switch Only (no coil), Maintained Contacts
B Series Trip (Current)
with Auxiliary Switch, Silver Contacts Terminal Type:
M Series Trip (Current) Aux Switch .110 QC x .020 QC
P 3 Switch Only, Maintained Contacts .060 Dia, Round Solder Turret
Q 3,4 Switch Only, Maintained Contacts .058 Dia, Round Q.C.
R 3,16 Switch Only, Maintained Contacts .080 Dia x .020 Flat Q.C.
S 3 Series Trip (Current) .060 Dia, Round Solder Turret
T 3,4 Series Trip (Current) .058 Dia, Round Q.C.
U 3,16 Series Trip, Maintained Contacts .080 Dia x .020 Flat Q.C.
with Auxiliary Switch, Gold Contacts
2 3,4 Switch Only, Maintained Contacts .058 Dia, Round Q.C.
3 3,16 Switch Only, Maintained Contacts .080 Dia x .020 Flat Q.C.
4 3,4 Series Trip (Current) .058 Dia, Round Q.C.
5 3,16 Series Trip, Maintained Contacts .080 Dia x .020 Flat Q.C.
9 Series Trip (Current) Aux Switch .110 QC x .020 QC
Notes:
1 One actuator is located in the center of each multi-pole breaker.
2 For Switch Only circuits, select Current Coil Rating from the above chart:
3 One Auxiliary Switch is supplied per breaker. On two-pole breakers, standard Auxiliary
Switch mounting is in pole one. Auxiliary Switch option limited to Series Trip & Switch Only
circuits, & is not available in single pole illuminated breakers, or Back Connected Screw or
Push-in Stud terminals.
4 Mates with AMP .058” diameter pin receptacles: 60983-1 (gold plated) & 60983-2
(tin plated).
5 For neon bulb applications at 120VAC @ 47K, 1/4 WATT and for 250VAC applications @
150K, 1/4 WATT, external resistors must be supplied by customer.
6 On Visi-Rocker breakers, Visi portion of rocker cannot be the same color as the bezel.
7 For LED (DC or rectied AC) applications, LED is mounted in the center of the rocker
actuator with electrical characteristics: 100 millicandela at 20mA; Maximum power
dissipation = 75mW at 25°C; Maximum forward current = 25mA; Typical forward voltage
= 2.1V at 20mA; Typical reverse current = 100uA at 3V. Customer supplies the proper
external resistor limiting current to these values.
8 Rocker color for LED’s and green neon lamp must be clear, smoke gray, white translucent
or match color of LED or neon lamp.
9 Other colors available. Consult factory.
10 TUV 20A, VDE 15A. UL Recognized and CSA Accepted to 30 amps.
Screw Terminals or Push-in Stud recommended above 20 amps.
11 TUV or VDE Certied must have I-O or Dual Legends.
Legend required on Visi-Rocker breakers.
12 30 amp rating not available with delay’s 30, 32, 34, 92 or 94.
13 Screw Terminals are VDE certied only with use of ring terminal attached to wire.
14 Terminal code A available with circuit codes A & B only.
15 Printed circuit board available with UL recognized approval only.
16 Auxiliary switch (at Q.C.) available with UL recognized approvals only.
12 AGENCY APPROVAL 10
C UL Recognized & CSA Accepted
D VDE Certied, UL Recognized & CSA Accepted
E TUV Certied, UL Recognized & CSA Accepted
5 FREQUENCY & DELAY
03 DC 50/60Hz, Switch Only 32 DC, 50/60Hz Short
10 DC Instantaneous 34 DC, 50/60Hz Medium
12 DC Short 62 50/60Hz Short, Hi-Inrush
14 DC Medium 64 50/60Hz Medium, Hi-Inrush
20 50/60Hz Instantaneous 72 DC, Short,Hi-Inrush
22 50/60Hz Short 74 DC,Medium, Hi-Inrush
24 50/60Hz Medium 92 DC, 50/60Hz Short, Hi-Inrush
30 DC, 50/60Hz Instantaneous 94 DC, 50/60Hz Medium, Hi-Inrush
1
Series
2
Actuator
3
Poles
6
Current Rating
7
Terminal
8
Illumination
12
Agency
Approval
4
Circuit
5
Frequency
& Delay
M G B H1 62 C C734 620
9
Actuator
Color
10
Legend
11
Bezel Color
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
18 |M-Series Circuit Breaker - Rocker UL489A/UL Recognized – Ordering Scheme
8 ROCKER ILLUMINATION
Non-illuminated A
Neon 4 Neon Green Glow 8
without resistor, 120VAC/250VAC B C
LED 7, 8 Red Green Amber
without resistor D G K
with resistor, 4-8 VDC E H L
with resistor, 9-16 VDC F J M
9 ACTUATOR & LEGEND COLOR
Solid Color Actuator Legend
1 White Black
2 Black White
3 Red White
4 Green White
5 Blue White
6 Yellow Black
7 Gray Black
8 Orange Black
Visi-Rocker 6 Visi & Legend (remainder of rocker same color as bezel)
1 White
2 Black
3 Red
4 Green
5 Blue
6 Yellow
7 Gray
8 Orange
Illuminated 7 Actuator Legend
A Clear White
B Red Transparent White
C Green Transparent White
D Amber Transparent White
E Smoke Gray Transparent White
F White Translucent Black
2 ACTUATOR 1
Non-Illuminated Two Color illuminated
single color Visi-Rocker single color
A Angled D Indicate ON F Angled
B Flat E Indicate OFF G Flat
11 BEZEL COLOR / STYLE 8
Color without Rockerguard with Rockerguard
White A 1
Black B 2
Gray G 7
1 SERIES
M
3 POLES
1 One
5 FREQUENCY & DELAY
10 DC Instantaneous
12 DC Short
14 DC Medium
72 DC, Short,Hi-Inrush
74 DC,Medium, Hi-Inrush
10 LEGEND 10
1 No Legend (Single Color or Illuminated Rocker Options Only)
2 ON - OFF Vertical
3 ON - OFF Horizontal
4 I - O Vertical
5 I - O Horizontal
6 Dual Vertical
7 Dual Horizontal
12 AGENCY APPROVAL 9
J UL489A Listed & TUV Certied
M UL Recognized & CSA Accepted
N TUV Certied, UL Recognized & CSA Accepted
T UL489A Listed
6 CURRENT RATING (AMPERES)
CODE AMPERES
020 0.020 225 0.250 420 2.000 710 10.500
025 0.025 230 0.300 522 2.250 611 11.000
030 0.030 235 0.350 425 2.500 711 11.500
035 0.035 240 0.400 527 2.750 612 12.000
040 0.040 245 0.450 430 3.000 712 12.500
045 0.045 250 0.500 435 3.500 613 13.000
050 0.050 255 0.550 440 4.000 614 14.000
055 0.055 260 0.600 445 4.500 615 15.000
060 0.060 265 0.650 450 5.000 616 16.000
065 0.065 270 0.700 455 5.500 617 17.000
070 0.070 275 0.750 460 6.000 618 18.000
075 0.075 280 0.800 465 6.500 620 20.000
080 0.080 285 0.850 470 7.000 622 22.000
085 0.085 290 0.900 475 7.500 624 24.000
090 0.090 295 0.950 480 8.000 625 25.000
090 0.095 410 1.000 485 8.500 630 30.000
210 0.100 512 1.250 490 9.000
215 0.150 415 1.500 495 9.500
220 0.200 517 1.750 610 10.000
4 CIRCUIT 2
without Auxiliary Switch
B Series Trip (Current)
with Auxiliary Switch, Silver Contacts Terminal Type:
M Series Trip (Current) Aux Switch .110 QC x .020 QC
S 3 Series Trip (Current) .060 Dia, Round Solder Turret
T 3,4 Series Trip (Current) .058 Dia, Round Q.C.
U 3,16 Series Trip, Maintained Contacts .080 Dia x .020 Flat Q.C.
with Auxiliary Switch, Gold Contacts
4 3,4 Series Trip (Current) .058 Dia, Round Q.C.
5 3,16 Series Trip, Maintained Contacts .080 Dia x .020 Flat Q.C.
9 Series Trip (Current) Aux Switch .110 QC x .020 QC
Notes:
1 One actuator is located in the center of each multi-pole breaker.
2 One Auxiliary Switch is supplied per breaker. Auxiliary Switch option limited to Series Trip
& Switch Only circuits, and is not available in single pole illuminated breakers, or with Back
Connected Screw or Push-in Stud terminals.
3 Mates with AMP .058” diameter pin receptacles: 60983-1 (gold plated) & 60983-1
(tin plated).
4 For neon bulb applications at 120VAC @ 47K, 1/4 WATT and for 250VAC applications @
150K, 1/4 WATT, external resistors must be supplied by customer.
5 For LED (DC or rectied AC) applications, LED is mounted in the center of the rocker
actuator with electrical characteristics as follows: 100 millicandela at 20mA; Maximum
power dissipation = 75mW at 25°C; Maximum forward current = 25mA; Typical forward
voltage = 2.1V at 20mA; Typical reverse current = 100uA at 3V. Customer supplies the
proper external resistor limiting current to these values.
6 On Visi-Rocker breakers, Visi portion of rocker cannot be the same color as the bezel.
7 Rocker color for LED’s and green neon lamp must be clear, smoke gray, white translucent
or match color of LED or neon lamp.
8 Other colors available. Consult factory.
9 UL Recognized, CSA Accepted, UL489A Listed, and TUV Certied to 30 amps.
Screw Terminals recommended above 20 amps.
10 UL489A Listed must have ON-OFF or Dual legends.
TUV Certied approvals must have I - O or Dual legends.
11 Terminal code A available with circuit codes A & B only.
12 Printed circuit board available with UL recognized approval only.
13 Auxiliary switch (at Q.C.) available with UL recognized approvals only.
7 TERMINAL
1 Push-On 0.250 Tab (Q.C.) A 11 Push-In Stud
2 Screw 8-32 with Upturned Lugs P 12 Printed Circuit Board
3 Screw 8-32 (Bus Type)
1
Series
2
Actuator
3
Poles
6
Current Rating
7
Terminal
8
Illumination
12
Agency
Approval
4
Circuit
5
Frequency
& Delay
M A B A1 61 1 J214 620
9
Actuator
Color
10
Legend
11
Bezel Color
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
| 19
M-Series Circuit Breaker - Rocker – Circuit & Terminal Diagrams
Notes:
1 All dimensions are in inches [millimeters].
2 Tolerance ±.020 [.51] unless otherwise specied.
3 Schematic shown represents current trip circuit.
Circuit & Terminal Diagrams: in. [mm]
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
20 |M-Series Circuit Breaker - Rocker – Dimensional Specications
Notes:
1 Dimensions apply to all variations shown. Notice that circuit breaker line & load terminal orientation on indicate OFF is opposite of indicate ON.
2 I-O, ON-OFF or dual legends available for vertical or horizontal mounting. For pole orientation with horizontal legend, rotate front view clockwise 90°.
3 All dimensions are in inches [millimeters].
4 Tolerance ± 0.20 [.51] unless otherwise specied.
Dimensional Specifications: in. [mm]
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
| 21
M-Series Circuit Breaker - Rocker – Supplementary Diagrams
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
22 |M-Series, Circuit Breaker - Time Delay Values
,
Notes:
1 Delay Curves 12,14, 22, 24, 32, 34, 62, 64, 72, 74, 92, 94: Breakers to hold 100% and must trip at 135% of rated current and greater within the time limit shown in this curve.
2 Delay Curves 10, 20, 30: Breakers to hold 100% and must trip at 150% of rated current and greater within the time limit shown in this curve.
3 All Curves: Curve data shown represents breaker response at ambient temperature of 77°F (25°C) with no preloading. Breakers are mounted in standard wall-mount position.
4 The minimum inrush pulse tolerance handling capability is 12 times the rated current on standard delays and 18 times the rated current on high inrush delays. These values are based on a 60 Hz 1/2 cycle,
8.33 ms pulse. High inrush delays should be specied for applications with high initial surge currents of short duration, such as switching power supplies, highly capacitive loads and transformer loads.
Medium Medium D4
Instantaneous
Short Short D2
Dual Rated AC/DC
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
| 23
Sales Representatives, Distributors & Company Prole
Authorized Sales Representatives and Distributors
About Carling
Founded in 1920, Carling Technologies is a leading manufacturer of electrical and electronic switches
and assemblies, circuit breakers, electronic controls, power distribution units, and multiplexed power
distribution systems. With four ISO registered manufacturing facilities and technical sales oces worldwide,
Carling Technologies Sales, Service and Engineering teams do much more than manufacture electrical
components, they engineer powerful solutions! To learn more about Carling please visit
www.carlingtech.com/company-prole.
To view all of Carling’s environmental, quality, health & safety certications please visit
www.carlingtech.com/environmental-certications
Click on a region of the map below to nd your local representatives and distributors or visit
www.carlingtech.com/ndarep.
EUROPE
MIDDLE
EAST
SOUTH
AMERICA
ASIA-PACIFIC
OCEANIA
AFRICA
MEXICO
USA
CANADA
Worldwide Headquarters
Carling Technologies, Inc.
60 Johnson Avenue, Plainville, CT 06062
Phone: 860.793.9281 Fax: 860.793.9231
Email: sales@carlingtech.com
Northern Region Sales Oce: nrsm@carlingtech.com
Southeast Region Sales Oce: sersm@carlingtech.com
Midwest Region Sales Oce: mrsm@carlingtech.com
West Region Sales Oce: wrsm@carlingtech.com
Latin America Sales Oce: larsm@carlingtech.com
Asia-Pacific Headquarters
Carling Technologies, Asia-Pacic Ltd.,
Suite 1607, 16/F Tower 2, The Gateway,
Harbour City, 25 Canton Road,
Tsimshatsui, Kowloon, Hong Kong
Phone: Int + 852-2737-2277 Fax: Int + 852-2736-9332
Email: sales@carlingtech.com.hk
Shenzhen, China: shenzhen@carlingtech.com
Shanghai, China: shanghai@carlingtech.com
Pune, India: india@carlingtech.com
Kaohsiung, Taiwan: taiwan@carlingtech.com
Yokohama, Japan: japan@carlingtech.com
Europe | Middle East | Africa Headquarters
Carling Technologies LTD
4 Airport Business Park, Exeter Airport,
Clyst Honiton, Exeter, Devon, EX5 2UL, UK
Phone: Int + 44 1392.364422 Fax: Int + 44 1392.364477
Email: ltd.sales@carlingtech.com
Germany: gmbh@carlingtech.com
France: sas@carlingtech.com
www.carlingtech.com REV_01_2018