RB551V-30 SMALL SIGNAL DIODE VOLTAGE RANGE 30 Volts CURRENT 500 mAmperes FEATURES * High current rectifier Schottky diode * Low voltage ,low inductance * For power supply SOD-323 MECHANICAL DATA Case: Molded plastic Epoxy: UL 94V-O rate flame retardant Lead: MIL-STD-202E method 208C guaranteed Mounting position: Any Weight: 0.004 grams .071(1.80) .063(1.60) MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS .006(.15) .014(.35) .010(.25) .055(1.40) .047(1.20) .106(2.70) .098(2.50) .003(.08) * * * * * MAX.039(1.00) O Ratings at 25 C ambient temperature unless otherwise specified. Single phase, half wave, 60 Hz, resistive or inductive load. REF .019(0.46) .004(.10) .000(.00) For capacitive load, derate current by 20%. Dimensions in inches and (millimeters) MAXIMUM RATINGS (@T A =25 OC unless otherwise noted) SYMBOL RB551V-30 UNITS VRM 30 Volts Maximum DC Reverse Voltage VR 20 Volts Maximum Average Forward Rectified Current IO 0.5 Amps Amps RATINGS Non-Repetitive Peak Reverse Voltage Non-Repetitive Peak Forward Surge Current Operating and Storage Temperature Range IFSM 2 TJ,TSTG -40~+125 SYMBOL RB551V-30 O C ELECTRICAL CHARACTERISTICS (@T A =25 C unless otherwise noted) O PARAMETER Maximum Instantaneous Forward Voltage Maximum Instantancous Reverse Current CONDITIONS @IF=100mA @IF=500mA @VR=20V VF IR 0.36 0.47 100 UNITS Volts uA VC 2006-3 RATING AND CHARACTERISTICS CURVES ( RB551V-30 ) 10A 100m 1A 10m 125 OC 1m 125 OC IR(A) IF(A) 100m O 75 C 10m 75OC 100u 25OC O 25 C 10u O -25 C 1m -25 OC 1u 100m 0 1000 0.1 0.2 0.3 0.4 100n 0.5 0 10 20 30 40 VF(V) VR(V) Figure1 Forward Characteristics Figure2 Reverse Characteristics 1.0 TJ=25OC IO(A) CT(pF) 100 0.5 10 0 0 10 20 30 40 0 0 25 50 75 100 VR(V) Ta(OC) Figure3 Capacitance between terminals characteristics Figure4 Derating curve 125 150 DISCLAIMER NOTICE Rectron Inc reserves the right to make changes without notice to any product specification herein, to make corrections, modifications, enhancements or other changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or use of any product or circuit. Rectron products are not designed, intended or authorized for use in medical, life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.