S/MOD/SPD03505/F/20/04/2015 Relais Statique DC DC Solid State Relay page 1 / 2 F/GB SPD03505 10-30VDC input 5A/24VDC output * Compatibilite du brochage avec les Relais Electro-mecaniques . * Commande DC Non polarisee. * Sortie DC. * Importantes surcharges en courants admissibles. * Haute immunite aux perturbations exterieures. * Ecreteur de surtension integre. * Pin to pin compatible with Electromechanic Relays. * DC and Non-polarized control. * DC Output. * Sustain high Inrush current . * High immunity level. * Integrated clamping voltage. Fig. 1 :Caracteristique d'entree / Control characteristic Caracteristiques de commande (a 20C) / Control characteristics (at 20C) DC Parameter Symbol Min Nom Uc 10 24 Tension de commande / Control voltage Ic 4 9,3 Courant de commande / Control current (@ Uc nom ) Uc off 2,5 Tension de relachement/Release voltage Resistance interne / Input internal resistor fig.1 Rc Max 30 12 2100 Unit V mA V Caracteristiques d'entree-sortie (a 20C) / Input-output characteristics (at 20C) Isolement entree-sortie / Input-output isolation Uimp 2500 V Caracteristiques thermiques / thermal characteristics Parameter Conditions Temperature de jonction max. / Maximum junction temperature Plage de temperature de fonctionnement /Operating temperature range Boitier / Case Uc nom, Tc-Ta=50C Resistance thermique jonction-boitier/Junction-case thermal resistance Resistance thermique jonction-Ambiant/Junction-ambient thermal resistance Uc nom, Tc-Ta=50C Tc-Ta=50C Constante de temps thermique du boitier/Case thermique delay time Caracteristiques generales / General characteristics Poids/Weight Temperature de soudage max / Maximum soldering heat(1 mm boitier/case) Conformite / Conformity Proud to serve you All technical characteristics are subject to change without previous notice. Caracteristiques sujettes a modifications sans preavis. 10 s EN60947-5-1 Symbol Tj max Tc max Rthj-c Rthj-a Tthc Typ. 125 -40 +100 12 41 8 C C C/W C/W minute Ts max 18 260 g C celduc r e l a i (R) s S/MOD/SPD03505/F/20/04/2015 page 2 / 2 F/GB Caracteristiques de sortie(a 20C) / Output characteristics (at 20C) Parameter Tension de charge / Load voltage Plage tension de fonctionnement / Operating range Courant nominal DC12/ DC12 nominal current Courant nominal DC13/ DC13 nominal current Courant de surcharge non repetitif /Non repetitive overload current Chute tension directe crete/ On state voltage drop Resistance de sortie a l'etat on / Static output on-resistance Courant de fuite etat bloque/ Off state leakage current Courant de charge minimum / Minimum load current Conditions ( see Fig. 2 ) ( see Fig. 2 ) tp=1s (Fig. 3) @ Il nom, Uc nom , Il=2A @Ul=24V Uc nom DC Uc nom DC Uc nom DC Temps de fermeture/ Turn on time Temps d'ouverture/ Turn off time Frequence max de commutation / Operating switching frequency Transil de protection contre les surtension/Transient voltage suppressor -Tension d'ecretage/ Breakdown voltage -Puissance maximum / Peak power dissipation -Tension crete (ecreteur de tension) / Peak voltage (clamping voltage) EMC Test d'immunite conduite/Conducted immunity level EMC Test d'immunite conduite/Conducted immunity level Symbol Ul Ulmin-max Il DC12 Il DC13 Il pulse Vd R on max Ilk max Ilmin ton max toff max fs Typ. 24 0-30 5 5 25 0,3 60 <1 1 50 600 100 Unit V V A A A V m mA mA s s Hz* @1mA Pulse 10/1000s Ubr min 36 V Pr 600 W Up max 60 V IEC 1000-4-4 (bursts) 1kV criterion A /4kV criterion B IEC 1000-4-5 (shocks) Control :0,5kV crit. A Output 1kV crit. A * Possibilite de monter jusqu'a 1kHz:Mais prevoir un derating de courrant. /1kHz possible with a derating current Fig. 3 : Courant de surcharge non repetitif / Non repetitive surge current Fig. 2 : Courant en fonction de la temperature ambiante / Load current vs. ambient temperature characteristics Precautions : * Dans le cas de plusieurs modules cote a cote, prevoir un derating en courant. * Sur charges inductives prevoir une diode de roue libre (ou ecreteur de surtension ). Cautions : * In case of many SSRs side by side , take a derating current in to account . * On inductive loads put a free-wheeling diode ( or clamp ). (R) celduc www.celduc.com r e l a i s 5, Rue Ampere BP30004 42290 SORBIERS - FRANCE E-mail : celduc-relais@celduc.com Fax +33 (0) 4 77 53 85 51 Service Commercial France Tel. : +33 (0) 4 77 53 90 20 Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tel. +33 (0) 4 77 53 90 19