HT1000/2 Series
Copper Wire Analyzer
n All transmission and noise tests for voiceband are included.
n Open meter, which is pinpoint accurate even in the presence
of shunt resistance (dirty open), is included.
nThe built-in TDR locates shorts, crosses, opens, and those
short bridge taps that plague VDSL at distances ranging
from the end of the test leads to 14.7 km (45,000 ft). It can
trace two pairs simultaneously with pair comparison mode
to identify potential cable trouble spots.
n Dual trace TDR allows technician to compare good pair to
questionable pair; reads accurately to open or shorted pair.
TDR traces can be saved and uploaded to PC for review.
n Auto test / incremental pair test - user can configure up
to 8 series of tests to run automatically. This can be used
on single, stand-alone pairs or in conjunction with the
incremental pair test and bulk pair recovery capability.
nBuilt-in pair recovery program allows technician to gather,
store and recall data on defective pairs to compare the
condition over time.
nThe auto test stores test results in a comma delimited format
that can be uploaded via the integrated USB port to a
customer-driven database.
n Download firmware updates via the integrated USB port.
n Spectrum analyzer - loss readings up through the VDSL2
range test protocols.
n Send and receive frequency spectrum through VDSL2 band.
n Spectrum analyzer assists the technician in finding
interrupters that cause disruptions to DSL service - will read
to VDSL2 band.
nADSL and VDSL2 with optional card installed, xDSL
cards allow technicians to interface with the CO (DSLAM)
and measure communication protocols, such as speed -
upstream and downstream, signal to noise ratios and
percent utilization.
nThe built-in modem uses the latest technology to provide
full test capabilities for xDSL and vectored DSL without the
need for separate instruments.
nRFL uses three- or four-wire setup and pinpoints fault size
and location with simple temperature and cable gauge
adjustments.
n Model specific functionality allows the user to tailor their
purchase to meet their exact needs.
SPECIFICATIONS
Function Accuracy, whichever is greater
AC voltage 300 V AC/DC
DC voltage 300 V AC/DC
Resistance range 0 Ω to 1000 KΩ (±2%, ±1 Ω)
Leakage 1 Ω to 999 MΩ (±3%), 150 V
open circuit output
Longitudinal balance +30 dBrn to +80 dBrn (±2 dBrn)
Super Stress™ -10 dBrn to +80 dBrn (±2 dBrn)
Load coil detection 0 coil to 4 coils (±1 coil)
Loop current 0 mA to ±100 mA (±2%, ±1 mA)
Power influence +40 dBrnC to +100 dBrnC (±2 dBrnC)
Loss (Voice Band) -40 dBm to +10 dBm (±1 dBm)
Open meter 0 m (0 ft) to 900 m (3,000 ft)
±2%, ±1.5 m (5 ft)
900 m (3,000 ft) to 15 km (50,000 ft)
(±3%)
Auto test 7 user-selectable auto test scripts,
200 pair storage, retest capability,
Incremental pair testing program
ID tone FED ID tone
Frequency: 577.5 Hz (±1%)
Amplitude: 0 dBm, 600 Ω (±1 dBm)
ID Tone
Frequency: Alternating 800 Hz
and 1230 Hz (±1%)
Amplitude: 0 dBm, 600 Ω (±1 dBm)
Caller ID Yes
Wideband tone sent Frequency: 20 KHz to 9 MHz (±1%)
Amplitude: 0 dBm, 135 Ω (±1 dBm)
Wideband tone receive Frequency: 20 KHz to 33 MHz
Amplitude: -90 dBm, +2 dBm
(±2 dBm)
Wideband loss Frequency: 20 KHz to 33 MHz
Amplitude: -90 dBm, +2 dBm
(±2 dBm)
Wideband spectrum Frequency: 20 KHz to 33 MHz
analyzer Amplitude: -90 dBm to +10 dBm
(±2 dBm)
-130 dBm/Hz to -30 dBm/Hz
(±2 dBm/Hz)
Impulse noise Amplitude: -45 dBm to +10 dBm
(±2 dBm)
Filters: HDSL, ADSL, ADSL2+
and VDSL2 (20 KHZ to 30 MHz)
Voiceband spectrum Frequency: 50 Hz to 4,100 Hz
analyzer Amplitude: -64 dBm to 0 dBm
(±2 dBm)
-76 dBm/Hz to -12 dBm/Hz
(±2 dBm/Hz)