MBR2520
THRU
MBR25100
25 Amp
Schottky Barrier
Rectifier
Features
Maximum Ratings
Operating Temperature: -55°C to +150°C
Storage Temperature: -55°C to +150°C
Microsemi
Catalog
Number
Device
Marking Maximum
Recurrent
Peak
Reverse
Voltage
Maximum
RMS
Voltage
Maximum
DC
Blocking
Voltage
MBR2520 MBR2520 20V 14V 20V
MBR2530 MBR2530 30V 21V 30V
MBR 2535 MBR2535 35V 24.5V 35V
MBR2540 MBR2540 40V 28V 40V
MBR2545 MBR2545 45V 31.5 45V
MBR2560 MBR2560 60V 42V 60V
MBR25100 MBR25100 100V 70V 100V
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward
Current IF(AV) 25A TC = 130°C
Peak Forward Surge
Current IFSM 150A 8.3ms, half sine
Maximum Forward
Voltage Drop Per
Element VF .63V IFM = 25A per
element;
TA = 25°C*
Maximum DC
Reverse Current At
Rated DC Blocking
Voltage
IR
*Pulse test: Pulse width 300 µsec, Duty cycle 1%

 INCHES MM
     
A .595 .620 15.11 15.75
B .380 .405 9.65 10.29
GR
B
Q
H
U
L
D
C
J
K
A
FS
T
U ------ .050 ----- 1.27
C .160 .190 4.06 4.82
D .025 .035 0.64 0.89
F .142 .147 3.61 3.73
G .190 .210 4.83 5.33
H .110 .130 2.79 3.30
J .018 .025 0.46 0.64
K .500 .562 12.70 14.27
L .045 .060 1.14 1.52
Q .100 .120 2.54 3.04
R .080 .110 2.04 2.79
S .045 .055 1.14 1.39
www.mccsemi.com
Metal of siliconrectifier, majonty carrier conducton
Guard ring for transient protection
Low power loss high efficiency
High surge capacity, High current capability
TO-220AC
20 to 100 Volts
T .235 .255 5.97 6.48
MBR2580 MBR2580 80V 56V 80V
MBR2020-2045
MBR2060 .84V
MBR2080-20100 .75V
0.2mA TJ = 25°C
omponents
21201 Itasca Street Chatsworth

 !"#
$% !"#
MCC
MBR2520 thru MBR25100
Instantaneous Reverse Leakage Current - MicroAmperes versus
Percent Of Rated Peak Reverse Voltage - Volts
Average Forward Rectified Current - Amperes versus
Ambient Temperature - °C
Figure 3
Forward Derating Curve
25 50 100 130 150
00
5
8
10
Single Phase, Half Wave
60Hz Resistive or Inductive Load
Amps
°C
75
15
20
25
Instantaneous Forward Current - Amperes versus
Instantaneous Forward Voltage - Volts
Figure 1
Typical Forward Characteristics
Volts
4
6
20
10
Amps
.
2 .7
.3 .4 .5
.6
.01
.02
.04
.06
.1
.2
.4
.6
1
225°C
40
60
100
.8
Figure 2
Typical Reverse Characteristics
Volts
.4
.6
2
1
µ
Amps
20
150
50
75 100
125
.001
.002
.00
4
.006
.01
.02
.04
.06
.1
.2
4
6
10
TJ=25°C
www.mccsemi .com
MCC
1 100
4
0
25
50
75
8
Figure 4
Peak Forward Surge Current
Peak Forward Surge Current - Amperes versus
Number Of Cycles At 60Hz - Cycles
Amps
Cycles
2
6
10 20 60 80
40
100
125
150
MBR2580-25100
MBR2520-2545
MBR2560