Series AM1MR-Z
1 Watt | DC-DC Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832)
F 051e R9.G 1 of 4 North America only
FEATURES:
Regulated Single Output
1000VDC Isolation
Continuous Short Circuit Protection
Operating temperature: -40°C to +85°C
RoHS Compliant
Industry Standard Pinout
MTBF>3,500,000 hours
14 Pin DIP Package
Models
Single output
Model
Input
Voltage
(V)
Output
Voltage
(V)
Output
Current
max (mA)
Isolation
(VDC)
Input
Current FL |
No Load
(mA)
Efficiency
(%)
AM1MR-0503SZ
4.5-5.5
3.3
303
1000
220
363
30
57
AM1MR-0505SZ
4.5-5.5
5
200
1000
220
313
35
65
AM1MR-0507SZ
4.5-5.5
7.2
139
1000
312
30
66
AM1MR-0509SZ
4.5-5.5
9
111
1000
307
35
67
AM1MR-0512SZ
4.5-5.5
12
83
1000
303
35
66
AM1MR-0515SZ
4.5-5.5
15
67
1000
303
35
64
AM1MR-1203SZ
10.8-13.2
3.3
303
1000
148
20
60
AM1MR-1205SZ
10.8-13.2
5
200
1000
130
20
63
AM1MR-1207SZ
10.8-13.2
7.2
139
1000
128
20
66
AM1MR-1209SZ
10.8-13.2
9
111
1000
126
20
67
AM1MR-1212SZ
10.8-13.2
12
83
1000
126
20
66
AM1MR-1215SZ
10.8-13.2
15
67
1000
122
20
68
AM1MR-2403SZ
21.6- 26.4
3.3
303
1000
74
10
63
AM1MR-2405SZ
21.6- 26.4
5
200
1000
66
10
68
AM1MR-2407SZ
21.6- 26.4
7.2
139
1000
64
10
68
AM1MR-2409SZ
21.6- 26.4
9
111
1000
63
10
69
AM1MR-2412SZ
21.6- 26.4
12
83
1000
62
10
68
AM1MR-2415SZ
21.6- 26.4
15
67
1000
62
10
66
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Nominal
Typical
Maximum
Units
Voltage range
5
12
24
4.5- 5.5
10.8-13.2
21.6- 26.4
VDC
Filter
Capacitor
Absolute Maximum Rating (100
ms)
5
12
24
7
15
28
VDC
Input reflected current
20
mA
Isolation Specifications
Parameters
Conditions
Typical
Rated
Units
Tested I/O voltage
60 sec
1000
VDC
Resistance
At 500VDC
>1000
MOhm
Capacitance
60
pF
Output Specifications
Parameters
Conditions
Typical
Maximum
Units
Voltage accuracy
±2
%
Short Circuit protection
Continuous
Short circuit restart
Auto-Recovery
Line voltage regulation
LL ~ HL
±0.5
% of Vin
Series AM1MR-Z
1 Watt | DC-DC Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832)
F 051e R9.G 2 of 4 North America only
Output Specifications (continued)
Parameters
Conditions
Typical
Maximum
Units
Load voltage regulation
From 0% to 100% Load
±0.5
%
Load voltage regulation (3.3V output)
From 0% to 100% Load
±1
%
Temperature coefficient
±0.02
%/oC
Ripple & Noise
20MHz Bandwidth
50
mVp-p
General Specifications
Parameters
Conditions
Typical
Maximum
Units
Switching frequency
50
KHz
Operating temperature
Full Load
-40 to +85
oC
Storage temperature
-40 to +125
oC
Maximum case temperature
100
oC
Cooling
Free Air Convection
Humidity
95
% RH
Case material
Non-Conductive Plastic (UL94V-0)
Weight
2.7
g
Dimensions (L x W x H)
20.30 x 10.16 x 6.90mm (0.80 x 0.40 x 0.27 inches)
MTBF
>3,500,000hrs dual (MIL-HDBK -217F, Ground Benign, t=+25oC)
Maximum soldering temperature
1.5mm from case for 10 sec
260
oC
Safety Specifications
Parameters
Agency Approvals
CE
Safety Standards
EN 55032, Class B
IEC61000-4-2
IEC61000-4-3
IEC61000-4-4
IEC61000-4-6
IEC61000-4-8
Also designed to meet IEC 60950-1
Pin Out Specifications Dimensions
Pin
Single
1
- V input
7
NC
8
No Pin
9
+ V output
10
No Pin
11
- V output
14
+ V input
NC: No Connection
15.24
(0.60)
10.16
(0.40)
Printed Face
6.90
(0.27)
3.05
(0.12)
0.50
(0.02)
7.62
(0.30)
20.30
(0.80)
7
814
1Bottom View
91011
2.54
(0.10)
0.25
(0.01)
Series AM1MR-Z
1 Watt | DC-DC Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832)
F 051e R9.G 3 of 4 North America only
Radiated and Conducted Emissions Application circuit:
C1
L1
470µF/100V
12 µH
Typical Efficiency Chart Examples
0
10
20
30
40
50
60
70
80
90
100
20% 40% 60% 80% 100%
Eff %
Loading %
AM1MR-0515SZ Efficiency vs. Loading
Series AM1MR-Z
1 Watt | DC-DC Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832)
F 051e R9.G 4 of 4 North America only
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3.Mechanical drawings and specifications are for reference only. 4.All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5.Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
0
10
20
30
40
50
60
70
80
90
100
20% 40% 60% 80% 100%
Eff %
Loading %
AM1MR-1215SZ Efficiency vs. Loading
0
10
20
30
40
50
60
70
80
90
100
20% 40% 60% 80% 100%
Eff %
Loading %
AM1MR-2415SZ Efficiency vs. Loading