ACDC 800 Watts HDS800 Series xppower.com * High Efficiency up to 92% * 1U Profile, High Power Density * Programmable Output Voltage (0105%) * Programmable Output Current (0105%) * Parallel Operation * Fully Featured Signals & Controls * 3 Year Warranty Specification Input General * 90-264 VAC (127-370 VDC), see derating curve Input Frequency * 47-63 Hz Input Current * 8.0 A/4.0 A typical at 115/230 VAC Inrush Current * 30.0 A/60.0 A typical at 115/230 VAC Power Factor * 0.98/0.95, typical at 115/230 VAC full load Earth Leakage Current * <1.0 mA at 264 VAC/60 Hz Input Voltage Output Output Voltage * Output Trim * Output Voltage Program* Output Current Program * Initial Set Accuracy * Minimum Load * Start Up Delay * Start Up Rise Time * Hold Up Time * Line Regulation * Load Regulation * Transient Response * Ripple & Noise * Overvoltage Protection * Overtemperature Protection * Overload Protection Short Circuit Protection Temperature Coefficient Remote Sense * * * Enable Current Share Standby Output See model table 5.0% by potentionmeter 0-105% of rated output 0-105% of rated output 1% No minimum load required 800 ms maximum 100 ms maximum at full load 8 ms minimum 1% V1: 1%, standby output: 3% <1% for a 25% step load change 150 mV pk-pk all voltages, see note 1 Tracks output voltage. See application notes, Recycle AC to reset Primary and secondary heatsinks monitored. Output shuts down, auto recovers >105% rated power, constant current Auto recovery 0.02%/C (0-50 C) * Compensates for 0.5 V max voltage drop If remote sense is not required, local sense must be used * Output must be enabled. See application notes, power supply is shipped with enable links fitted * 5 supplies can share within 5% * 5 V at 0.5 A, present whenever AC is applied (9V at 0.3A, user selectable, by connecting `VSET', Pin 18 of CN2 to `GND') Efficiency Isolation Switching Frequency Power Density Signals & Controls MTBF * See model table * 3000 VAC Input to Output, 1500 VAC Input to Ground, 500 VAC Output to Ground * PFC 65 kHz typical, PWM 40-200 kHz variable * 10.1 W/in3 * Enable, Current Share, V Program, I Program, 5 V Standby, PWM switching * 90 kHrs to MIL-HDBK-217F at 25 C Environmental Operating Temperature * -20 C to 70 C, derate linearly from 100% load at 50 C to 50% load at 70 C Cooling * Internal fan fitted. Speed increases with load and internal temperature Operating Humidity * 20-90% R.H. non-condensing Storage Temperature * -40 C to +85 C Storage Humidity * 10-95% R.H. Vibration * 10-500 Hz, 2g 10 min/cycle, 60 min period for each axis. Compliant to IEC68-2-16, IEC 68-2-64 EMC & Safety Emissions Harmonic Currents Voltage Flicker ESD Immunity * * * * Radiated Immunity EFT/Burst Surge * * * Conducted Immunity Magnetic Field Dips & Interruptions * * * Safety Approvals * EN55022 class B conducted & radiated EN61000-3-2 class A EN61000-3-3 EN61000-4-2, 4 kV contact, 8 kV air discharge, Perf Criteria A EN61000-4-3, 3 V/m, Perf Criteria A EN61000-4-4, level 2, Perf Criteria A EN61000-4-5, installation class 3, Perf Criteria A EN61000-4-6, 3 V, Perf Criteria A EN61000-4-8, 1 A/m, Perf Criteria A EN55024, >95% 10 ms, 30% 500 ms, >95% 5000 ms, Perf Criteria A, A, B UL60950-1, CSA C22.2 No. 60950-1, EN60950-1 Output Power 800 800 800 800 800 800 800 Output Current Min Max 0.0 A 66.7 A 0.0 A 53.4 A 0.0 A 33.5 A 0.0 A 26.7 A 0.0 A 22.3 A 0.0 A 16.7 A 0.0 A 13.4 A Output Voltage V1 W W W W W W W 12.0 15.0 24.0 30.0 36.0 48.0 60.0 VDC VDC VDC VDC VDC VDC VDC Efficiency(2) Model Number 89% 90% 92% 92% 92% 92% 92% HDS800PS12 HDS800PS15 HDS800PS24 HDS800PS30 HDS800PS36 HDS800PS48 HDS800PS60 Notes 1. Ripple & noise is measured with 20 MHz bandwidth and using 12" twisted pairwire terminated with 0.1 F & 47 F capacitors in parallel. 2. Measured with 230 VAC input and full load. Mechanical Details 1.61 (40.9) 9.80 (249.0) +V M6 24 23 -V 3-M4 Max Length = 4 mm 2.19 (74.0) Airflow 2 1 5.00 (127.0) TRIM STATUS LED CN2 E 2.52 (64.0) N L 7.80 (198.0) 0.55 (14.0) 1.46 (37.0) 0.81 (20.5) 6-M4 (Both sides) Max Length = 6 mm 0.45 (11.5) Mating connector CN2: PHDR-24VS housing, SPHD-002T-P05 contacts Notes 1. All dimensions are in inches (mm). 2. Weight 3.85 lb (1.75 kg) 3. Maintain 2" (50mm) clear space at each end. 0.98 (25.0) 8.70 (221.0) Pin Function 1 NC. 2 NC. 3 AUX 4 GND 5 SCL 6 SDA 7 AUX 8 GND Description Not Connected Not Connected Auxiliary Power Signal Ground I2C Serial Data I2C Serial Data Auxiliary Power Signal Ground 1.06 (26.9) 0.32 (8.0) CN2 Control Pin Connections Pin Function Description 9 VCI V Program 10 GND Signal Ground 11 ACI I Program 12 GND Signal Ground 13 EN+ Inhibit ON/OFF (+) 14 AUX Auxiliary Power 15 ENInhibit ON/OFF (-) 16 GND Signal Ground Pin Function 17 PAR 18 VSET 19 POK 20 GND 21 VS22 VO23 VS+ 24 VO+ Description Parrallel Current Auxiliary Output Set Power OK Signal Ground Remote Sense (-) Local Sense (-) Remote Sense (+) Local Sense (+) Derating Curve Thermal Derating Curve Input Derating Curve 100 100 90 80 Load (%) Load (%) 80 60 40 70 60 50 20 -10 40 0 10 20 30 40 50 Ambient Temperature (C) 60 70 90 100 110 120 Input Voltage (VAC) 264 ACDC HDS800 Models and Ratings LED Status LED Status Solid (Green) Solid (Orange) Slow Blink (Green) Fast Blink (Red) Solid (Red) Slow Blink (Red) Intermittent Blink (Red) Short & Long Blink (Red) Output Status DC Output OK DC Output OK in remote control mode Output Not Enabled Over Voltage Over Loaded Over Temperature Fan Fail AUX Standby Failure Output Voltage Programming Via External Voltage 120 100 Output Voltage (%) Output Voltage (%) Via External Resistor 120 100 80 60 40 20 80 60 40 20 0 0 0 1 2 3 4.5 4.8 5 4 0 1 2 3 4 Resistor Value (k ) Programming Voltage (VDC) 4.5 4.8 5 Output Current Program Via External Voltage 120 Via External Resistor 120 100 Output Current (%) 100 Output Current(%) ACDC HDS800 Application Notes 80 60 40 80 60 40 20 20 0 0 0 1 2 3 4 4.5 5 0 1 2 3 4 Resistor Value (k ) Programming Voltage (VDC) Remote Enable 2K SW EN+ OFF Power OFF ON Power ON 5V 5 V SB 5 V SB 5 V SB 2K 2K EN+ L H 5V EN- EN- GND GND OFF Power OFF ON Power ON EN+ SW Power OFF Power ON 5V 5V EN- L/H (A) Using internal 5 V standby (B) Using external transistor GND GND (C) Using external voltage source 4.5 5 OVP Setting POK Signal OVP Trip Point POWER SUPPLY 5 V Auxiliary Pin 7 200% 3300R 196% Pin 19 Power not OK Power OK 120% GND Pin 8, 10, 12, 16, 20 114% CN9 Connector 100% 105% 7% % of Nominal Output Voltage Open drain signal, low when PSU turns on Maximum sink current: 20 mA Maximum drain voltage: 40 V CN2 1 2 1 CN2 CN2 2 1 2 1 CN2 23 24 23 24 23 24 23 24 CN2 Remote Sense 2 1 Current Share 2 NC NC AUX GND SCL SDA 2 VCI GND ACI GND EN+ 23 24 CN2 1 AUX GND Load AUX EN- GND PAR VSET 1 POK GND Load VS- VO- VS+ VO+ 23 24 2 1 1 2 1 2 2 NC NC NC NC NC NC NC NC AUX GND AUX GND AUX GND AUX GND SCL SDA SCL SDA SCL SDA SCL SDA AUX GND AUX GND AUX GND AUX GND VCI GND VCI GND VCI GND VCI GND ACI GND ACI GND ACI GND ACI GND EN+ AUX EN+ AUX EN+ AUX EN+ AUX EN- GND EN- GND EN- GND EN- GND PAR VSET PAR VSET PAR VSET PAR VSET POK GND POK GND POK GND POK GND VS- VO- VS- VO- VS- VO- VS- VO- VS+ VO+ VS+ VO+ VS+ VO+ VS+ VO+ 23 24 23 24 23 23 24 24 Local Sense CN2 2 23 24 CN2 1 1 Load NC NC AUX GND 2 Current Sharing with Remote Sensing SCL SDA AUX GND VCI GND ACI GND NC NC NC NC NC NC NC NC EN+ AUX EN- GND AUX GND AUX GND AUX GND AUX GND PAR VSET SCL SDA SCL SDA SCL SDA SCL SDA POK GND AUX GND AUX GND AUX GND AUX GND VS- VO- VS+ VO+ 23 1 24 Must be used if remote sense is not required. 2 1 2 1 2 1 2 VCI GND VCI GND VCI GND VCI GND ACI GND ACI GND ACI GND ACI GND EN+ AUX EN+ AUX EN+ AUX EN+ AUX EN- GND EN- GND EN- GND EN- GND PAR VSET PAR VSET PAR VSET PAR VSET POK GND POK GND POK GND POK GND VS- VO- VS- VO- VS- VO- VS- VO- VS+ VO+ VS+ VO+ VS+ VO+ VS+ VO+ 23 24 23 24 23 24 23 24 Current Sharing with Local Sensing Notes In parallel operation, it is possible that only one unit will operate if the load is less than 5% of the combined rated output load. It is possible to have more than five units in parallel, contact sales for details. 31-Mar-14 ACDC HDS800 Application Notes