TXD2000 2/2000 REV A Page 1
FEATURES
!!
!!
! Wide Range Input of 90-264VAC, 1000 Watts,
High Range Input of 180-264VAC, 2000 Watts,
!!
!!
! Harmonic Correction to EN61000-3-2
!!
!!
! Active Current Sharing
!!
!!
! No Load Operation
!!
!!
! Optional ORing Diode
!!
!!
! 70-80% Efficiencies
!!
!!
! FCC / CISPR 22 Class A EMI Filtering
!!
!!
! Self-Cooled 5”x 8”x 12” Chassis
!!
!!
! EN61000-4 Immunity
AGENCY APPROVALS
Internet: http://www.cdpowerelectronics.com
Power Electronics Division, United States
3400 E Britannia Drive, Tucson, Arizona 85706
Phone: 800.547.2537 Fax: 520.770.9369
Power Electronics Division, Europe
C&D Technologies (Power Electronics) Ltd.
132 Shannon Industrial Estate, Shannon, Co. Clare, Ireland
Tel: +353.61.474.133 Fax:+353.61.474.141
TXD2000
2000 WAT T
AC/DC POWER SUPPLY
Product Data Sheet
DESCRIPTION
The TXD2000 Series is a flexible, modular, 2000 Watt
design offering two high current outputs in a 5 x 8 x 12
package. Output voltages from 2.5 VDC through 48
VDC are standard. With Power Factor Correction, EMI
compliance to FCC and CISPR22, CE Mark and
immunity to EN61000-4, the TXD2000 Series is ready
for global deployment. Standard features include
Remote Sense Compensation, Output Voltage
Adjustment, Active Current Sharing, Remote Inhibit,
Power Fail Warning, DC OK Signal and Thermal
Shutdown. An optional ORing diode is offered on
models with an output voltage of 12 VDC or above.
TXD2000 2/2000 REV APage 2
Input Specifications
Parameters Conditions Min Typ Max Units
Operating Range
1000W 47-63Hz 90 264 VAC
2000W 47-63Hz 180 264 VAC
Inrush Current 120VAC, 250C, cold start 80 Apk
240VAC, 250C, cold start 160 Apk
Efficiency Nominal line, full load 70 75 80 %
Holdup Full load 20 msec
Power Factor (1) Full load 0.99
Notes: (1) Harmonic currents meet EN61000-3-2
Output Voltage Modules and Maximum Rated Load
Output Output Voltage Output Current Output Power
Voltage Code Voltage (Maximum Continuous) (Maximum Continuous)
A 5.0 200A 1000W
B 12.0 83A 1000W
C 15.0 67A 1000W
D 18.0 55A 1000W
E 24.0 42A 1000W
F 28.0 36A 1000W
G 36.0 28A 1000W
H 48.0 21A 1000W
J 20.0 40A 800W
K 3.3 182A 600W
L 2.5 200A 500W
Output Specifications
Parameter Conditions Min Typ Max Units
Output Power All environmental and line conditions
90-264VAC 1000 Watts
180-264VAC Limited by output module selection 2000 Watts
Voltage Adjustment Range Relative to nominal output voltage +5 %
Output Regulation Line, load or cross +0.2 %
Minimum Load 0 Amps
PARD Measured at output terminals, 20MHz 50 mv or 1% pk-pk
Temperature Coefficient 00 to 500C+0.2 %/0C
Environmental Specifications
Parameter Conditions Min Typ Max Units
Ambient Temperature Output de-rated linearly to 50% of
(Operating) rated capacity between 500C and 700C 0 +70 0C
Ambient Temperature Non-operating -50 +85 0C
Altitude (Operating) -200 +10,000 Feet
Altitude (Non-operating) -200 +50,000 Feet
Shock Per MIL-STD-810D, Method 516.3, Procedure II, in each axis, including NTSA drop test
Vibration Per MIL-STD-810D, Method 514.3, Procedure II, in each axis, including NTSA drop test
Cooling The TXD2000 is provided with internal cooling fans.
TXD2000 2/2000 REV A Page 3
The information provided herein is believed to be reliable; however, C&D TECHNOLOGIES assumes no responsibility for inaccuracies or omissions. C&D TECHNOLOGIES assumes
no responsibility for the use of this information, and all use of such information shall be entirely at the user’s own risk. Prices and specifications are subject to change without notice.
No patent rights or licenses to any of the circuits described herein are implied or granted to any third party. C&D TECHNOLOGIES does not authorize or warrant any C&D TECHNOLOGIES
product for use in life support devices/systems or in aircraft control applications.
Product Features
Features Characteristic
Remote Sense 500mV compensation
Active Current Sharing Single Wire; 5% current share if outputs are over 25% of rated load
ORing Diode Optional (not available on modules below 12V)
OVP 125% of nominal (+7.5%)
Thermal Shutdown Automatic Restart
DC OK Signal Logic “1” when output is within +3% of nominal
Power Fail Warning Transition to Logic “0” at least 5msec before loss of output regulation
Remote Inhibit Logic “0” applied will inhibit output (referenced to –Sense terminal)
Product Compliances
Approval Characteristic
UL and cUL UL1950, 3rd Edition (1)
VDE EN60950
FCC Class A requirements for conducted emissions
CISPR 22 Class A requirements for conducted emissions
EN61000-4-2 Electrostatic Discharge, Level 4
EN61000-4-4 Electrical Fast Transients, Level 3
EN61000-4-5 Input Surge Immunity, Level 3
EN61000-3-2 Harmonic Currents, Class A
CE Mark Low Voltage Directive
Notes: (1) UL1950, 3rd Edition incorporates the requirements of CSA 950.
TXD2000 F L L H
Ordering Information
OUTPUT VOLTAGES
A = 5V G = 36V
B = 12V H = 48V
C = 15V J = 20V
D = 18V K = 3.3V
E = 24V L = 2.5V
F = 28V
Model Designation
BASE MODEL
Chassis: “8” = 5” x 8” x 12”; “M” = modified
Output Voltage Module A: (see chart below)
Output Voltage Module B: (see chart below)
Standard Fan: “F”:
Remote Inhibit - TTL Logic Level “0” turns the power supply OFF:
Power Fail Warning - TTL Logic Level “0” indicates AC is LOST:
ORing Diode - “D” indicates an ORing Diode is installed in each module; “N” = None:
DC OK - TTL Logic Level “1” indicates DC is OK:
TXD2000 2/2000 REV APage 4
MECHANICAL
MODULE
CONTROL CONNECTOR
AMP NO. 87579-2 OR EQUIVALENT
PIN FUNCTION
NO.
1 REMOTE INHIBIT
2 DC OK
3N/C
4N/C
5 POWER FAIL WARNING
6 CURRENT SHARE
7 + SENSE
8N/C
9_ SENSE
10 N/C
DETAIL A
SCALE: NONE
ADJ
PIN 1
8-32UNC-2B
25 MAX. SCREW PENETRATION
4 PLACES
.95
1.226.375
6.000
5.00
.6012.00
.19 MAX.
8.00
1.00
1.60
1.95
3.45
6.38
1.85
.315 TYP.
V2V1
ADJ. ADJ.
TB1
6-32 UNF-2A PHILSLOT
TORQUE TO 9 INCH/LBS. MAX
3 PLACES
1/4-20 UNC-2A
HEX HEAD SCREW
4 PLACES
AIR FLOW