___________________ Preface 1 ___________________ Description of the device SIMATIC NET PG/PC - PROFIBUS CP 5612 Operating Instructions 2 ___________________ Software installation 3 ___________________ Hardware installation 4 ___________________ Configuration 5 ___________________ Technical specifications A ___________________ Approvals 08/2016 C79000-G8976-C278-03 Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION indicates that minor personal injury can result if proper precautions are not taken. NOTICE indicates that property damage can result if proper precautions are not taken. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems. Proper use of Siemens products Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed. Trademarks All names identified by (R) are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens AG Division Process Industries and Drives Postfach 48 48 90026 NURNBERG GERMANY Document order number: C79000-G8976-C278 09/2016 Subject to change Copyright (c) Siemens AG 2016. All rights reserved Preface Validity of this documentation These operating instructions are valid for the following product: CP 5612 Article number: 6GK1 561-2AA00 Content of this documentation These operating instructions contain information about the installation and configuration of the CP 5612 communications processor. Updated operating instructions on the Internet You will find the current version of these operating instructions on the Product Support pages under the following entry ID: 58826992 (https://support.industry.siemens.com/cs/ww/en/view/58826992) Further documentation The documents listed below contain more detailed information on commissioning and using the communications processor. You will find this documentation on the Product Support pages on the Internet under the following entry link: Support (https://support.industry.siemens.com/cs/ww/en/ps) Enter the entry ID shown below of the relevant manual as the search item. Configuration manual Commissioning PC Stations This provides you with detailed information on commissioning and configuring SIMATIC NET PC communications modules. Entry ID: 109488960 (https://support.industry.siemens.com/cs/ww/en/view/109488960) System manual SIMATIC NET Industrial Communication with PG/PC - Volume 1- Basics Entry ID: 77376110 (https://support.industry.siemens.com/cs/ww/en/view/77376110) - Volume 2- Interfaces Entry ID: 77378184 (https://support.industry.siemens.com/cs/ww/en/view/77378184) The system manuals introduce the topic of industrial communication and explain the communications protocols used. There is also a description of the OPC interface as user programming interface. CP 5612 Operating Instructions, 08/2016, C79000-G8976-C278-03 3 Preface Installation manual "SIMATIC NET PC Software" This document contains detailed information on installing the "SIMATIC NET PC Software". Entry ID: 77377602 (https://support.industry.siemens.com/cs/ww/en/view/77377602) System manual PROFIBUS Network Manual In this document you will find detailed information about setting up a PROFIBUS network. Entry ID: 35222591 (https://support.industry.siemens.com/cs/ww/en/view/35222591) SIMATIC NET documentation You will find the entire SIMATIC NET documentation on the pages of Product Support: 15247 (https://support.industry.siemens.com/cs/ww/en/ps/15247) Go to the required product group and make the following settings: Entry list Entry type "Manuals / Operating Instructions" Trademarks The following and possibly other names not identified by the registered trademark sign (R) are registered trademarks of Siemens AG: SIMATIC NET, HARDNET, SOFTNET, CP 1612, CP 1613, CP 5612, CP 5613, CP 5614, CP 5622 Industry Online Support In addition to the product documentation, the comprehensive online information platform of Siemens Industry Online Support at the following Internet address: (http://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo2&aktprim=99&lang= en) Apart from news, there you will also find: Project information: Manuals, FAQs, downloads, application examples etc. Contacts, Technical Forum The option submitting a support query: (https://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo&lang=en&objid =38718979&caller=view) Our service offer: Right across our products and systems, we provide numerous services that support you in every phase of the life of your machine or system - from planning and implementation to commissioning, through to maintenance and modernization. CP 5612 4 Operating Instructions, 08/2016, C79000-G8976-C278-03 Preface You will find contact data on the Internet at the following address: (http://www.automation.siemens.com/partner/guiwelcome.asp?lang=en) SITRAIN - Training for Industry The training offer includes more than 300 courses on basic topics, extended knowledge and special knowledge as well as advanced training for individual sectors - available at more than 130 locations. Courses can also be organized individually and held locally at your location. You will find detailed information on the training curriculum and how to contact our customer consultants at the following Internet address: (www.siemens.com/sitrain) SIMATIC NET glossary Explanations of many of the specialist terms used in this documentation can be found in the SIMATIC NET glossary. You will find the SIMATIC NET glossary on the Internet at the following address: 50305045 (http://support.automation.siemens.com/WW/view/en/50305045) CP 5612 Operating Instructions, 08/2016, C79000-G8976-C278-03 5 Preface CP 5612 6 Operating Instructions, 08/2016, C79000-G8976-C278-03 Table of contents Preface ................................................................................................................................................... 3 1 2 3 Description of the device ......................................................................................................................... 9 1.1 Product characteristics.............................................................................................................. 9 1.2 PROFIBUS interface ...............................................................................................................10 1.3 Meaning of the LED display ....................................................................................................12 Software installation .............................................................................................................................. 13 2.1 Installing the "SIMATIC NET PC Software" ............................................................................13 2.2 Uninstalling the "SIMATIC NET PC Software"........................................................................14 Hardware installation............................................................................................................................. 15 3.1 Safety notices .........................................................................................................................15 3.2 Installing hardware ..................................................................................................................16 3.3 Hardware compatibility............................................................................................................17 4 Configuration ........................................................................................................................................ 19 5 Technical specifications ........................................................................................................................ 21 A Approvals.............................................................................................................................................. 23 CP 5612 Operating Instructions, 08/2016, C79000-G8976-C278-03 7 Table of contents CP 5612 8 Operating Instructions, 08/2016, C79000-G8976-C278-03 Description of the device 1.1 1 Product characteristics Properties The CP 5612 is a communications processor for connecting PCs (personal computers) or PGs (programming devices) to PROFIBUS and MPI networks. The essential properties are as follows: Transmission speeds up to 12 Mbps. Floating RS-485 connector. Linking of up to 32 devices (PC, PG, SIMATIC S7 or ET 200) to form a network segment. - By linking several segments with repeaters, up to 64 nodes can be connected. The additional interface signals for a direct link to a PLC (Programmable Logic Controller) are supported up to 187.5 Kbps. Installation in PGs and PCs with a PCI slot. The following is supported: - PCI, 33 MHz / 66 MHz, 32 bits / 64 bits - Plug and play CP 5612 Operating Instructions, 08/2016, C79000-G8976-C278-03 9 Description of the device 1.2 PROFIBUS interface Appearance The following graphic shows the CP 5612 communications processor: 1.2 1 LEDs 2 PROFIBUS interface PB1 (master or slave) PROFIBUS interface PROFIBUS network The physical link between the PROFIBUS interface and the PROFIBUS network is via a floating RS-485 interface that is part of the module. Depending on the network configuration, data rates of 9.6 Kbps up to a maximum of 12 Mbps are possible in the PROFIBUS network. Note You will find information about the structure of a PROFIBUS network in the system manual "PROFIBUS Network Manual". The document is part of the Manual Collection. You will also find this on the Product Support pages under the following entry ID: 35222591 (http://support.automation.siemens.com/WW/view/en/35222591) CP 5612 10 Operating Instructions, 08/2016, C79000-G8976-C278-03 Description of the device 1.2 PROFIBUS interface PIN assignment The D-sub female connector has the following pin assignment: PIN Short name Meaning Input/output 1 NC Socket pin 1 is not connected. - 2 NC (M24) Socket pin 2 is not connected. With other MPI/DP components, the return line of the floating 24 V power supply may be via this pin. - 3 LTG_B Signal line B of the PROFIBUS connector. Input/output 4 RTSAS RTSAS, input signal for direct MPI link. The control signal is "1" active when the automation system connected over a special MPI cable is sending. Input 5 M5EXT M5EXT return line (GND) of the 5 V power supply. The current load of an external consumer connected between P5EXT and M5EXT must not exceed a maximum of 90 mA. Output 6 P5EXT P5EXT supply (+5 V) of the 5 V power supply. The current load of an external consumer connected between P5EXT and M5EXT must not exceed a maximum of 90 mA (short-circuit proof). Output 7 NC (P24V) Socket pin 7 is not connected. With other MPI/DP components, the P24V supply of the floating 24 V power supply may be via this pin. - 8 LTG_A Signal line A of the PROFIBUS connector. Input/output 9 RTS RTS output signal of the CP module. The control signal is "1" active when the device (PG or PC) is sending. Output Shield The shield is connected to components of the connector housing. CP 5612 Operating Instructions, 08/2016, C79000-G8976-C278-03 11 Description of the device 1.3 Meaning of the LED display 1.3 Meaning of the LED display LED display The meaning of the LED display is as follows: Green and yellow LED Meaning Green on Indicates token rotation (in other words, normal operation) Green off Incorrect bus parameters, defective bus (e.g. short-circuit) or CP not in operation Green flashing fast, yellow off Module not started; normal status following reset Green and yellow flashing alternately When using more than one module in a PG/PC: Identification of the module using a diagnostics tool Green and yellow flashing synchronously Exception state; error in firmware Yellow on DP slave mode Yellow off Not DP slave mode Yellow flashing at one-second intervals Error in DP slave mode. CP 5612 12 Operating Instructions, 08/2016, C79000-G8976-C278-03 Software installation 2.1 2 Installing the "SIMATIC NET PC Software" "SIMATIC NET PC Software" The "SIMATIC NET PC software" is one of several software packages with which you can operate the communications processor in your PG/PC. To configure the communications processor, you require additional configuration software. You will find information on the configuration software in the section "Configuration (Page 19)". Condition The plug and play function is activated in the BIOS of your PG/PC. Prior to hardware installation Install the software as described in the installation manual "SIMATIC NET PC Software". You will find this installation manual on the Product Support pages under the following entry ID: 77377602 (https://support.industry.siemens.com/cs/ww/en/view/77377602) You should also note the current information on the "SIMATIC NET PC software" on the Product Support pages: Support (https://support.industry.siemens.com/cs/ww/en/ps/15362/pm) After the hardware installation After installing the communications processor, your PG/PC automatically searches for a suitable driver. 1. Follow the instructions of the Hardware Wizard of Windows. 2. Do not activate the search for drivers on the Internet. CP 5612 Operating Instructions, 08/2016, C79000-G8976-C278-03 13 Software installation 2.2 Uninstalling the "SIMATIC NET PC Software" 2.2 Uninstalling the "SIMATIC NET PC Software" Condition The "SIMATIC NET PC Software" is installed on the PG/PC. Procedure Note The recommended procedure removes the entire "SIMATIC NET PC Software" on the PG/PC, not only the driver for the communications processor. Uninstall the entire software package as described and recommended in the installation manual "SIMATIC NET PC Software". You will find the installation manual on the "SIMATIC NET PC Software" DVD or on the Product Support pages under the following entry ID: 77377602 (https://support.industry.siemens.com/cs/ww/en/view/77377602) CP 5612 14 Operating Instructions, 08/2016, C79000-G8976-C278-03 Hardware installation 3.1 3 Safety notices WARNING Electric shock possible - work only when the power supply is off Opening the PG/PC and plugging or pulling the communications processor is permitted only when the power is off. Turn off your PG/PC and pull the power cable connector before you start the hardware installation. NOTICE Note the EC directives Components can be damaged or destroyed by electrostatic discharge. When installing, keep to the rules for electrostatically sensitive devices (ESD). * Pick up components and modules only by their edges. Do not touch the pins or conductors. * Before opening the PG/PC, make sure that you discharge any electrostatic charge from your body. You can do this by touching metal parts on the back panel of the PG/PC pulling the power plug. * Make sure that you also discharge any electrostatic charge from tools you intend to use for the work on the PG/PC. * Do not operate the PG/PC with the housing open. NOTICE Firm mounting The communications processor must sit firmly and uniformly in the slot. Check that the module sits firmly in the slot as described in the manual accompanying your PG/PC. Note Oblique installation position is permitted Some PG/PC designs require oblique installation of the communications processor. This is permitted. CP 5612 Operating Instructions, 08/2016, C79000-G8976-C278-03 15 Hardware installation 3.2 Installing hardware 3.2 Installing hardware Permitted number of communications processors in the PG/PC The driver software supports a maximum of 2 communications processors per PG/PC, of which a maximum of 1 communications processor may be in configured mode. Automatic adaptation of the bus clock speed The communications processor is designed for a bus clock speed of 66 MHz. If the communications processor is inserted in a PCI slot with a higher bus clock speed, the bus clock speed is adapted to the highest possible bus rate of the communications processor. Examples: The PCI slot is automatically reduced to a bus clock speed of 66 MHz. The bus clock speed of the communications processor is automatically reduced to 33 MHz if a communications processor with a 33 MHz bus clock speed is connected. Procedure Note * First install the software First install the software before you insert the communications processor in the slot. * Activated plug and play function The plug and play function must be activated in the BIOS of your PG/PC. Follow the steps outlined below when inserting the communications processor: 1. Turn off your PG/PC and pull the power cable connector. 2. Open the PC housing as described in the manual accompanying your PG/PC. 3. Remove the cover of a free PCI slot. 4. Remove the communications processor from its packaging. 5. Insert the communications processor in the PCI slot and secure it. Make sure that the communications processor is correctly inserted and secured. 6. Close the PC housing as described in the manual accompanying your PG/PC. 7. Insert the power plug into the socket again and turn your PG/PC on. The plug and play function of Windows automatically searches for a driver. 8. Follow the instructions of the Hardware Wizard of Windows. Do not activate the search for drivers on the Internet. CP 5612 16 Operating Instructions, 08/2016, C79000-G8976-C278-03 Hardware installation 3.3 Hardware compatibility 3.3 Hardware compatibility Compatibility with other communications processors The CP 5612 can replace the following communications processors: CP 5621 CP 5611 A2 CP 5611 Note PCI module Please note: The CP 5612 is a PCI card. The CP 5621, on the other hand, is a PCI Express card. This means that you can only replace a CP 5621 with a CP 5612 if there is a PCI slot available on the PG/PC. Note If the previous CP has been removed from the PG/PC, no configuration changes need to be made You can adopt the configuration of the previous CP. To do this, you simply need to reload the configuration. Note the following: When loading the previous configuration, the previous CP has priority over the new CP. As long as the previous CP is connected, its configuration cannot be adopted by the new CP. You should therefore remove the previous CP from your PC/PG. Procedure for replacement When replacing a module, follow the steps described in the section "Hardware installation (Page 15)". CP 5612 Operating Instructions, 08/2016, C79000-G8976-C278-03 17 Hardware installation 3.3 Hardware compatibility CP 5612 18 Operating Instructions, 08/2016, C79000-G8976-C278-03 Configuration 4 Configuring To be able to configure the communications processor, the following engineering or configuration tools are available: STEP 7 V5.5 STEP 7 Professional (TIA Portal) Communication Settings (COML S7) The steps involved are described in the "Commissioning PC Stations" manual or in the relevant online helps. Compatibility during configuration If there is not yet a CP 5612 in the hardware catalog of your STEP 7 version, you can select a CP 5611 A2 or CP 5611 for configuration. The CP 5612 is downwards compatible with the configurations of the previous versions. CP 5612 Operating Instructions, 08/2016, C79000-G8976-C278-03 19 Configuration CP 5612 20 Operating Instructions, 08/2016, C79000-G8976-C278-03 5 Technical specifications Technical specifications of the CP 5612 Connection to PROFIBUS Amount 1 Transmission speeds 9.6 kbps, 19.2 kbps, 45.45 kbps, 93.75 kbps, 187.5 kbps, 500 kbps, 1.5 Mbps, 3 Mbps, 6 Mbps, 12 Mbps Design 9-pin D-sub female connector with screw locking mechanism RS-485 (ungrounded within the SELV limits) Properties Grounded cable shield Floating interface signals Connection to PG/PC PCI, 33 MHz / 66 MHz, 32 bit signal voltage: 5 VDC or 3.3 VDC V 2.2 plug and play Electrical specifications of the PCI plug-in connector Operating voltage Rated voltage 3.3 VDC and 12 VDC Permitted range 3.0 to 3.6 V DC for 3.3 V DC 11.0 to 13.0 V DC for 12 V DC Current consumption Effective power loss Properties Safety extra low voltage (SELV) to EN 60950 Typical for 3.3 V 150 mA Typical for 12 V 250 mA Typical 3.5 W Temperature (EN 60068-2-1+2) +5 to +50C Maximum temperature change 10 K/h Rel. humidity (EN 60068-2-78) 85% at 30 C, no condensation Rapid temperature change (EN 60068-2-14) +5 to +50C, 5 cycles Permitted ambient conditions Operating conditions Storage and transportation conditions Temperature (EN 60068-2-1+2) Maximum temperature change Rel. humidity (EN 60068-2-78) -20 to +60 C 20 K/h 95% at +25 C to +55C, no condensation CP 5612 Operating Instructions, 08/2016, C79000-G8976-C278-03 21 Technical specifications Technical specifications of the CP 5612 Fast temperature change * to EN 60068-2-14 * to EN 60068-2-30 -20 to +60 , 2 cycles +25 to +55C at 95% humidity Vibration, operating (EN 60068-2-6) Frequency 10 to 58 Hz Frequency 58 to 500 Hz Number of cycles 0.075 mm amplitude 10 m/s2 Acceleration 10/axis Shock, operating (EN 60068-2-27) Half sine Time Number of shocks 50 m/s2 (5 g) 30 ms 100/axis Flat module Short PCI card Design, dimensions and weight Module format Weight 98 g Dimensions (W x H x D) in mm 18 x 107 x 125 Electromagnetic compatibility Emission Immunity * to EN 55022 * to FCC Class B Class B On signal cables * Surge to EN 610004-5 * Burst to EN 61000-4-3 2 kV 2 kV to discharge of static electricity * Contact discharge to IEC 61000-4-2 6 kV to radiated radio frequencies * * to EN 61000-4-3 to EN 61000-4-6 10 V/m at 80 MHz to 2 GHz 10 V/m, 50% on-load factor at 900 MHz and 1.89 GHz 10 V/m, 80% amplitude modulation at 1 kHz, 10 kHz to 80 MHz CP 5612 22 Operating Instructions, 08/2016, C79000-G8976-C278-03 A Approvals Note The specified approvals apply only when the corresponding mark is printed on the communications processor. Electromagnetic compatibility - EMC directive The communications processor meets the requirements of the EC Directive:2004/108/EEC (EMC directive). The communications processor is designed for use in the following areas: Area of application Requirements Emission Immunity Residential areas, business and commercial opera- EN 61000-6-3 tions, and small businesses EN 61000-6-1 Industrial environment EN 61000-6-2 EN 61000-6-4 Declaration of conformity You will find the declaration of conformity for this communications processor on the Product Support pages under the following entry ID: 58826997 (https://support.industry.siemens.com/cs/ww/en/view/58826997) C-TICK approval The communications processor meets the requirements of the Australian AS/NZS 3548 standard according to EN 61000-6-3. CSA approval The communications processor has an approval in accordance with the Canadian CAN/CSA C22.2 No. 60950-1 standard. ICES conformity The communications processor meets the requirements of the Canadian standard ICES-003. It is rated as a digital device of Class B ("Class B digital apparatus"). CP 5612 Operating Instructions, 08/2016, C79000-G8976-C278-03 23 Approvals FCC approval This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Siemens AG is not responsible for any radio television interference caused by unauthorized modifications of this equipment or the substitution or attachment of connecting cables and equipment other than those specified by Siemens AG. The correction of interference caused by such unauthorized modification, substitution or attachment will be the responsibility of the user. The use of shielded I/O cables is required when connecting this equipment to any and all optional peripheral or host devices. Failure to do so may violate FCC and ICES rules. UL approval The communications processor has an approval in accordance with the US standard UL 60950-1. Marking for the customs union EAC (Eurasian Conformity) Customs union of Russia, Belarus and Kazakhstan Declaration of the conformity according to the technical regulations of the customs union (TR CU) CP 5612 24 Operating Instructions, 08/2016, C79000-G8976-C278-03