HM1500LF – Relative Humidity Module
HM1500LF HPC062_F www.meas-spec.com October 2012
2/5
ELECTRICAL CHARACTERISTICS
(Ta=23°C, Vs=5Vdc +/-5%, R
L
>1MΩ unless otherwise stated)
*Maximum power supply ramp up time to Vcc should be less than 4ms.
TYPICAL PERFORMANCE CURVES
HUMIDITY SENSOR
• Measurement conditions
HM1500LF is specified for accurate measurements within 10 to
95% RH.
Excursion out of this range (<10% or >95% RH, including
condensation) does not affect the reliability of HM1500LF
characteristics.
Dedicated HM15XX products are available for extreme RH
conditions (as HM1520 for low dewpoints). Consult MEAS-
FRANCE for further information.
• Modeled Signal Output
Humidity Characteristics Symbol Min
Unit
Humidity Measuring Range RH 0 100 %RH
Relative Humidity Accuracy (10 to 95% RH) RH +/-3 +/-5 %RH
Supply Voltage (regulated at 5Vdc*) Vs 5 Vdc
Nominal Output @55%RH (at 5Vdc) Vout 2.42 2.48 2.54 V
Current consumption Ic 1.4 2 mA
Temperature Coefficient (10 to 50°C) Tcc - 0.05 -0.1 %RH/°C
Average Sensitivity from 33% to 75%RH ∆Vout/∆RH +26 mV/%RH
Sink Current Capability (R
L
=33kΩ) Is 150 µA
Humidity Hysteresis +/-1 %RH
Time Constant (at 63% of signal, static) 33% to 75%RH τ 10 s
Warm up time (electronic) tw 150 ms
Humidity resolution 0.4 %RH
Output Impedance Z 70 Ω
10 1325 55 2480
15 1465 60 2605
20 1600 65 2730
25 1735 70 2860
30 1860 75 2990
35 1990 80 3125
40 2110 85 3260
45 2235 90 3405
50 2360 95 3555