I&Q NETWORKS IQF-24E Series Units to 300 MHz / High Precision / Phase Adjustable with External Cap / Hi-Rel Flatpack PRINCIPAL SPECIFICATIONS Model Number LO Frequency fo, MHz IQF-24E-***B 20 - 300 Video Bandwidth 15 MHz For complete Model Number replace *** with desired LO Center Frequency, fo in MHz. COMMON SPECIFICATIONS RF/LO Input Characteristics LO Bandwidth: 10%, centered at fo Impedance: 50 nom. VSWR: 1.5:1 max. RF Power Level: 0 dBm nom. LO Power Level @ fo: +10 dBm nom. Outline of E - Size Flatpack I & Q Output Characteristics Output Impedance: 50 nom. Conversion Loss (RF to I or Q): 10 dB typ., 12 dB max. IF Quadrature Balance (I to Q), @ 100 kHz IF Phase, @ LO=fo: 90 5 nom. (uncompensated) 90 1, @ LO=fo (after compensation at 25C) (over temperature range) Phase Variation: Ampl., @ LO=fo: NOTES: 1. Tolerance on 3 place decimals .010(.25) except as noted. 2. Dimensions in inches over millimeters. 3. Dimensions marked with * apply only at body. 4. All unmarked pins are case ground. 5. External capacitors in the range 1 to 10 pF required. 0.3 dB max. Weight, nominal: 0.32 oz (9 g) Operating Temperature: -- 55 to +85C RF and Video Bandwidths are typically much greater than specified. General Notes: 1. I & Q networks are integrated devices that produce two quadrature-phased, equal amplitude signals when fed RF and LO signals. 2. The IQF-24E series I&Q networks are factory adjusted with a reference capacitor at a given LO frequency. Upon customer installation, the units may be fine tuned as required by selecting an appropriate external capacitor value. 3. Merrimac I & Q networks comply with the relevant sections of MIL-M-28837 and may be supplied screened for compliance with additional specifications for military and space applications requiring the highest reliability. 24Oct95 ForfurtherinformationcontactM ERRIM AC /41 Fairfield Pl.,W estCaldw ell,NJ,07006 / 973-575-1300 /FAX 973-575-0531