Save Money & Installation Time New Cooper Bussmann A/C Disconnect Model Loaded With Features & Convenience Simplify your installation and power disconnection process with a series of new Cooper Bussmann Air Conditioner Disconnects. The new fusible and non-fusible, all in one, Bussmann A/C disconnects with integrated GFCI receptacle meets NEC(R) ground fault requirements. Disconnect With GFCI Receptacle: * Combines two installations into one * All GFCI units meet NEC(R) Ground Fault Requirements in 210.63, 210.8, 406.8(B)(1) * Provides a safe additional power source for contractors and homeowners Cooper Bussmann A/C Disconnects Also Meet Requirements For Other Single-Phase Applications Including: * Heat pumps * Swimming pools * Spas * Whirlpools * Pump houses NOTE: The 20A Ground Fault Receptacle must be wired to a separate 120V branch circuit than the pullout circuit B222-60F B222-60NF B222-60FGF Technical Specifications Disconnect Max HP Amp Rating Rating 120V 240V Wire Size Range Cu/Al 60C or 75C Enclosure Type Fuse Class 10 #14-3 NEMA 3R * * 10 #14-3 30A 1.5 3 60A 3 10 Cooper Bussmann Part Number Description Non-Fused B222-60NF 60A, Pull Out 60A 3 60A, Switch 60A 30A, Pull Out 60A, Pull Out B222-60NFGF B222-60NFNA Part Number B221-30F B221-30FGF B222-60F B222-60FGF 60A, Pull Out w/ GFCI 60A 3 10 Approximate Dimensions in Inches Height Width Depth Weight lbs * 8.80 13.00 5.50 2.50 3.29 NEMA 3R * 8.80 5.50 3.63 3.29 #14-3 NEMA 3R H or R H or R 8.80 13.00 5.50 2.50 3.29 #14-3 NEMA 3R H or R 8.80 5.50 2.50 3.29 #14-3 NEMA 3R 7.50 4.75 8.00 Fused 30A, Pull Out with GFCI 30A 60A, Pull Out with GFCI 1.5 60A 3 3 #14-3 10 NEMA 3R #14-3 NEMA 3R H or R 13.00 7.50 7.50 4.75 4.75 8.00 8.00 * Upstream overcurrent protection device (OCPD) not to exceed 30 Amps. Fused And Non-Fused Features: * A/C disconnects meet NEC(R) Code Requirements under articles 440.14 * Safety shield can be removed without tools. (not available on GFCI units) * GFCI units meet NEC(R) Code Requirements under articles 210.63, 210.8, and 406.8(B)(1). * NEMA 3R rainproof enclosures. * Knockouts on back, bottom and both sides. * Padlockable. * Two-position pullout handle locks safety shield when in the ON position. (Not available on GF or NA units.) Pullout handle can be stored in the compartment in the off position. * UL Listed and CSA Certified. * Suitable for use as service entrance equipment applications when used with field installable ground bar. (c)2012 Cooper Bussmann * St. Louis, MO 63178 6 3 6 - 3 9 4 - 2 8 7 7 * w w w. c o o p e r b u s s m a n n . c o m Printed in USA Reorder # 3116 7-30-12-5M