Instruction Sheet
SOLARLOK* Stamped
and Formed Contacts 408--10286
LOC B
1of 4
E2009 Tyco Electronics Corporation, Harrisburg, PA
All International Rights Reserved
TE logo and Tyco Electronics are trademarks.
*Trademark. Other products, logos, and company names used are the property of their respective owners.
TOOLING ASSISTANCE CENTER 1--800--722--1111
PRODUCT INFORMATION 1--800--522--6752
This controlled document is subject to change.
For latest revision and Regional Customer Service,
visit our website at www.tycoelectronics.com
14 DEC 09 Rev Band Connectors
Figure 1
Receptacle Connector
Assembly 1740939
Plug Connector
Assembly 1740940
Socket Housing
Socket Contact
2058454 or
2106356
Seal
Pinch Ring
Cable Screw Joint
Cable Screw Joint
Pinch Ring
Pin Contact
2058453 or
2106355
Pin Housing
Seal
1. INTRODUCTION
This instruction sheet provides assembly procedures
for the SOLARLOK Stamped and Formed Contacts
and Connectors. These contacts are to be used as
alternatives to standard screw--machined HVT
contacts currently used in photovoltaic products. The
contacts are a drop--in replacement and can be
directly assembled into existing SOLARLOK
Connectors. See Figure 1.
2. DESCRIPTION
The contacts are made from copper alloy and are
silver over nickel plate with a wire size range of
2.5--6.0 mm2[14--10 AWG]. The SOLARLOK
contacts will mate with existing screw--machined
SOLARLOK contacts and will fit into existing
SOLARLOK connector housings.
3. ASSEMBLY PROCEDURES
Refer to Instruction Sheet 408--10322 for
termination of the contacts and Application
Specification 114--13256 for application
requirements of the SOLARLOK Contacts and
Connectors. Assembly procedures show pin
contact and connector, but socket contact and
connector is assembled similarly.
This connector must be used only to interconnect
firmly fixed cables. Do NOT disconnect under
load.
To protect against shock, ensure that conductors
and their associated connectors are separated
from opposite polarity components.
Any kind of pollution (dust, humidity, etc.) during
the assembly process can degrade contact and
connector performance. This applies in particular
to the seals and the crimping of the contacts. A
clean assembly environment is therefore
essential.
3.1. Selection of Cable Seal and Pinch Ring for Cable
Connectors
SUse only UL/TÜV rated photovoltaic cable (see
Figure 9 for approved cables).
SPre--assembled connectors are for wire insula-
tion diameters 4.5--6.9 mm. Insert wire with
contact directly into the pre--assembled con-
nector. See Figure 7. All other wire insulation
sizes follow instruction Steps 3 thru 5.
SAlternative seals for varying wire insulation
sizes are provided in Figure 2.
NOTE
i
CAUTION
!
DANGER
CAUTION
!