Data sheet...
Industrial Ethernet
IE-C5ED8UG0050A46A46-X
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 16
D-32758 Detmold
Germany
Fon: +49 5231 14-0
Fax: +49 5231 14-292083
www.weidmueller.com
Technical data
Creation date April 29, 2013 9:07:28 PM CEST
Catalogue status 12.03.2013 / We reserve the right to make technical changes. 2
Dimensions and weights
Length 5 m Net weight 318 g
Temperatures
Operating temperature -40 °C...+80 °C Storage temperature -40 °C...+80 °C
Installation temperature -20 °C...+60 °C
Electrical properties
Insulation resistance 500.000 Ω Operating voltage 100 V
Standards
Impervious to smoke According to IEC 61034-2 Connector standard IEC 60603-7-51
Standard, assembly UL-Style 20963
(80°C/30V)
Standard, insulating material DIN EN 50290-2-25 (HD
624.5)
Standard, wire material
DIN EN 13602 Cu-ETP-A
Standard, shielding material DIN EN 13602 Cu-ETP-
A..B
Cable structure
Wire material Stranded tin-plated copper
wire
Standard designations LI9Y(ST)C11Y 4X2X0.14
VZN GN, SF/UTP
Strands
7
Cross-section 4*2*AWG 26/7 -
4*2*0.128 mm²
Insulation cross-section 0.95 mm Wire core insulation thickness 0.23 mm
Arrangement of wire cores Twisted pair Diameter of wire pair 1.9 mm
Colour sequence or wires - wire pairs white/blue - blue, white/
orange - orange, white/
green - green, white/
brown - brown
Filler
As central element,
Between the individual
wire pairs
Shielding
SF/UTP
Complete shielding Plastic foil, Aluminium foil,
Shielding braid made from
copper wiring
Shielding braid thickness 0.1 mm Overlap of shielding braid 90 %
Material sheath PUR Sheath diameter, min. 6.3 mm
Sheath diameter, max. 6.8 mm Sheathing material thickness 0.85 mm
Sheathing colour green (RAL 6018)
Electrical properties of cable
Category Cat.5 (ISO/IEC 11801) /
Cat.5e (TIA T568-B)
Operating voltage
100 V
Operating voltage, UL
30 V
Test voltage: wire-wire-shield, at RMS
50Hz, 1 min. 700 V
Characteristic impedance 100 ± 5 Ω at 100MHz Loop resistance 270 Ω/km
Deviation 40 ns/100m Resistance differential 2 %
Transfer impedance 100 mΩ/m at 10 MHz Insulation resistance 500.000 Ω
Capacity at 800 Hz 50 nF/km Signal propagation time 5.55 ns/m