Single Output Model Selection
MODEL OUTPUT ADJUSTMENT MAXIMUM OUTPUT PEAK OUTPUT LINE LOAD RIPPLE & NOISE INITIAL SETTING
VOLTAGE RANGE CURRENT CURRENT (NOTE 3) REGULATION REGULATION %p-p (NOTE 1) ACCURACY
MAP80-1005 5V 4.5V to 5.6V 16A 18A 0.2% 1% 1.4% 5.0V to 5.1V
MAP80-1012 12V/15V 11.5V to 15.5V 7.5/6A (Note 2) 9.2/7.3A (Note 2) 0.2% ±1% 1% 11.76V to 12.15V
MAP80-1024 24V/28V 23.0V to 29.0V 3.8/3.2A (Note 2) 4.6/3.9A (Note 2) 0.1% 0.5% 0.5% 23.8V to 24.2V
NOTES: 1) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth.
2) MAP80-1012 output currents are expressed as 12V/15V operation. MAP80-1024 output currents are expressed as 24V/28V operation.
3) Peak load for 60 seconds or less are acceptable, 10% duty cycle, maximum.
Features
RoHS lead-solder-exemption compliant
Wide-range input for 110/220 VAC applications
CE marked to Low Voltage Directive
Input transient & ESD compliance to
EN61000-4-2/-3/-4
Meets EN55022, Class B limits
TTL compatible Power Fail Signal
Greater than 175,000 Hours MTBF
Metric and SAE mounting inserts
Multiple Output Model Selection – 80W Continuous Output Power
MODEL OUTPUT ADJUSTMENT OUTPUT PEAK OUTPUT LINE LOAD RIPPLE & NOISE INITIAL SETTING
VOLTAGE RANGE CURRENT CURRENT (NOTE 1) REGULATION REGULATION %p-p (NOTE 2) ACCURACY
+5V 4.8V to 5.5V 14A 16A 0.2% 1% 1% 5.1V to 5.2V
MAP80-4000 +12V 11.52V to 12.48V 4A 7A 0.2% 1% 1% 11.9V to 12.1V
-5V Fixed 1A 1A 0.5% 2% 1% -4.8V to -5.4V
-12V Fixed 1A 1A 0.5% 2% 1% -11.5V to -12.5V
+5V 4.8V to 5.5V 14A 16A 0.2% 1% 1% 5.1V to 5.2V
MAP80-4001 +24V 23.04V to 24.96V 2A 3.5A 0.2% 1% 1% 24.0V to 24.1V
-12V Fixed 1A 1A 0.5% 2% 1% -11.5V to -12.5V
+12V Fixed 1A 1A 0.5% 2% 1% 11.5V to 12.5V
+5V 4.7V to 5.5V 14A 16A 0.2% 1% 1% 5.1V to 5.2V
MAP80-4002 +12V 11.52V to 12.48V 4A 7A 0.2% 1% 1% 12.0V to 12.1V
-12V Fixed 1A 1A 0.5% 2% 1% -11.6V to -12.4V
+12V Fixed 1A 1A 0.5% 2% 1% 11.6V to 12.4V
+5V 4.8V to 5.5V 14A 16A 0.2% 1% 1% 5.1V to 5.2V
MAP80-4003 +15V 14.40V to 15.60V 3.5A 6A 0.2% 1% 1% 14.6V to 15.1V
-5V Fixed 1A 1A 0.5% 2% 1% -4.8V to -5.4V
-15V Fixed 1A 1A 0.5% 2% 1% -14.4V to -15.5V
+5V 4.8V to 5.5V 14A 16A 0.2% 1% 1% 5.1V to 5.2V
MAP80-4004 +24V 23.04V to 24.96V 2A 3.5A 0.2% 1% 1% 24.0V to 24.1V
-15V Fixed 1A 1A 0.5% 2% 1% -14.4V to -15.5V
+15V Fixed 1A 1A 0.5% 2% 1% 14.4V to 15.5V
MAP80 AC-DC Series Data Sheet
MCD10144 Rev. 1.0, 02-Feb-10 Page 1 of 4 www.power-one.com
Power-One’s MAP80 Series of power supplies provides reliable, tightly-regulated DC power for commercial and
industrial systems which require high peak current capabilities. Wide-range AC input and full international safety, EMI,
and ESD compliance ensure worldwide acceptance. All units bear the CE Mark.
The MAP80 utilizes a variable frequency design with a thermally efficient U-channel chassis to provide full power
operation in convection-cooled applications. Design innovations include metric and SAE mounting inserts on each
mounting surface to provide integration flexibility. Dual-mode connectors provide traditional terminal block connections
or popular single-row Molex connector mating.
Single-output models feature wide-range output adjustability to meet a wide variety of standard and user-specific
output voltage requirements.
Description
Model numbers highlighted in yellow or shaded are not recommended for new designs.
Multiple Output Model Selection (Cont.) 80W Continuous Output Power
MODEL OUTPUT ADJUSTMENT OUTPUT PEAK OUTPUT LINE LOAD RIPPLE & NOISE INITIAL SETTING
VOLTAGE RANGE CURRENT CURRENT (NOTE 1) REGULATION REGULATION %p-p (NOTE 2) ACCURACY
+5V 4.8V to 5.5V 14A 16A 0.2% 1% 1% 5.1V to 5.2V
MAP80-4010 +12V 11.52V to 12.48V 4A 7A 0.2% 1% 1% 12.0V to 12.1V
-5V Fixed 1A 1A 0.5% 2% 1% -4.8V to -5.4V
-12V Fixed 3A 3A 0.5% 2% 1% -11.5V to -12.5V
+5V 4.8V to 5.5V 14A 16A 0.2% 1% 1% 5.1V to 5.2V
MAP80-4020 +12V 11.52V to 12.48V 4A 7A 0.2% 1% 1% 12.0V to 12.1V
-12V Fixed 1A 1A 0.5% 2% 1% -11.5V to -12.5V
-5V Fixed 3A 3A 0.5% 2% 1% -4.8V to -5.4V
NOTES: 1) Peak loads up to 90 Watts for 60 seconds or less are acceptable, (10% duty cycle max.). Peak power must not exceed 90 Watts.
2) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth.
Input Specifications
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Input Voltage - AC Continuous input range. 90 135 VAC
175 264
Input Frequency AC input. 47 63 Hz
Brown Out Protection Lowest AC input voltage that regulation is maintained with full rated loads. 90 VAC
Hold-up Time Nominal AC input voltage (115VAC), full rated load. 20 mS
Input Current 90 VAC (80W load). 2.5 ARMS
110VAC (80W load). 1.8
Input Protection Non-user serviceable internally located AC input line fuse.
Inrush Surge Current Internally limited by thermistor. Vin = 264VAC (one cycle). 25° C. 45 APK
Operating Frequency Switching frequency of power supply (varies with load). 22 120 kHz
Output Specifications
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Efficiency Full load, 115VAC. Varies with distribution of loads among outputs. 73 75 80 %
Minimum Loads MAP80-1012 0.42
MAP80-1024 0.21 Amps
MAP80-1005 and all multiple output models, main channel only. 1.00
Ripple and Noise Full load, 20MHz bandwidth. See Model Selection Chart.
Output Power Continuous output power, all multiple output models. 80 Watts
Peak output power (60s maximum, 10% duty cycle), all multiple output models. 90 Watts
Overshoot / Undershoot Output voltage overshoot/undershoot at turn-on, V1, V2. 1 %
Regulation Varies by output. Total regulation includes: line changes from 90-132 VAC See Model Selection Chart.
or 175-264, changes in load starting at 20% load and changing to 100% load.
Transient Response Recovery time, to within 1% of initial set point due to a 50-100% 500 µS
load change, 4% max. deviation. (Main output of multiple output units).
Turn-On Delay Time required for initial output voltage stabilization. 1 5 Sec
Turn-on Rise Time Time required for output voltage to rise from 10% to 90%. 20 mS
Interface Signals and Internal Protection
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Overvoltage Provided on MAP80-1005 and the main output of multiple output units. 5.5 6.8
Protection MAP80-1012 17 23 V
MAP80-1024 32 37
Overload Protection Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition.
Power Fail TTL compatible logic signal. Time before regulation dropout
Warning (Note 1) due to loss of input power at 110VAC. 4 mS
NOTES: 1) Power Fail Warning is not available on MAP80-1024. The MAP80-1012 is an open collector output, capable of sinking 35 mA, maximum.
MAP80 AC-DC Series Data Sheet
MCD10144 Rev. 1.0, 02-Feb-10 Page 2 of 4 www.power-one.com
Model numbers highlighted in yellow or shaded are not recommended for new designs.
Safety, Regulatory, and EMI Specifications
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Agency Approvals UL1950.
CSA 22.2 No. 234/950. Approved
EN60950 (TUV).
Dielectric Withstand Input to output. 2600 VDC
Voltage
Electromagnetic FCC CFR title 47 part 15 sub-part B - conducted & radiated. B
Interference, EN55022 / CISPR 22 conducted. B Class
Conducted EN55022 / CISPR 22 radiated. B
Input Transient EN61000-4-5 level 3. Line to line 1 kV
Protection Line to ground 2
Insulation Resistance Input to output. 7 M
Leakage Current Per EN60950, 264VAC. 500 µA
Environmental Specifications
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Altitude Operating. 10k ASL Ft.
Non-operating. 40k ASL Ft.
Operating Temperature Derate linearly above 50°C by 2.5% per °C At 100% load: 0 50 °C
to a maximum temperature of 70°C. At 50% load: 0 70 °C
Storage Temperature -55 85 °C
Temperature Coefficient 0°C to 70°C (After 15 minute warm-up). ±0.02 ±0.03 %/°C
Relative Humidity Non-condensing. 5 95 %RH
Shock Operating, peak acceleration. 20 G
Vibration Random vibration, 10Hz to 2kHz, 3 axis. 6 GRMS
Options
DESCRIPTION NOTES SIZE IMPACT
Cover Add ‘C’ suffix to model number or order part number 412-59585-G separately. 7.20" x 4.20" x 2.05"
For convection cooled applications, derate output power to 65 watts on all multiple (183.0mm x 107.0mm x 52.0mm)
output models and MAP80-1005. Derate MAP80-1012 and MAP80-1024 to 75 watts.
MAP80 AC-DC Series Data Sheet
MCD10144 Rev. 1.0, 02-Feb-10 Page 3 of 4 www.power-one.com
MAP80 AC-DC Series Data Sheet
MCD10144 Rev. 1.0, 02-Feb-10 Page 4 of 4 www.power-one.com
OVERALL SIZE: 7.20" x 4.20" x 1.80" (182.9mm x 106.7mm x 45.7mm)
WEIGHT: 1.8 LBS (0.82 kg)
INPUT & OUTPUT CONNECTIONS: 6-32 SCREW WIRE CLAMPS ON 0.312" (7.9mm) CENTERS, 0.045" (1.1mm)
SQUARE PINS ON 0.156" (3.9mm) CENTERS, MATES WITH MOLEX SERIES 2139, 6442, OR 41695
POWER FAIL CONNECTIONS: J1: 0.035" (0.9mm) SQUARE PINS ON 0.100" (2.5mm) CENTERS, MATES WITH MOLEX SERIES 2695/6471
CHASSIS: 0.090" (2.3mm) ALUMINUM ALLOY, WITH CLEAR FINISH
NUCLEAR AND MEDICALAPPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components
in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective
divisional president of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.