ACDC Fan 92 San Ace 92AD mm sq. General Specifications Material ........................... Frame: Plastics (Flammability: UL94V-0), Impeller: Plastics (Flammability: UL94V-0) Expected Life .................. Refer to specifications (L10:Survival rate: 90% at 60 , rated voltage,and continuously run in a free air state) Motor Construction ......... Brushless DC motor Motor Protection System Burnout protection at locked rotor condition Dielectric Strength ......... 50/60 Hz, 1,500 VAC, 1 minute (between input terminal and frame, and between sensor output and frame) Insulation Resistance ...... 10M or more at 50 0VDC megger (between lead conductor and frame) Sound Pressure Level (SPL) ... Expressed as the value at 1m from air inlet side Storage Temperature ......... -30 to75 (Non-condensing * Do not weld directly onto AC input terminals. 92x92x38mm Mass250g 9AD type Specifications The model no. below has ribs and no sensors. For models without ribs, append "1" to the model no. Model No. 9AD0901H12 9AD0901M12 Max. Airflow Max. Static Pressure SPL Operating Temperature Expected Life Rated Voltage Operating Voltage Range Frequency (Note) Rated Current Rated Input Rated Speed V V A W min-1 m/min CFM Pa inchHOdB(A) h Hz 100 to 240 90 to 264 50/60 0.08 0.06 4.5 3.0 3,850 3,100 1.50 1.18 53.0 41.7 90 56 0.36 0.22 40 33 -20 to 75 60,000/60 Note: 50/60 Hz compatible. The model no. below has ribs and low-speed sensors. For models without ribs, append "1" to the model no. Model No. 9AD0901H1H 9AD0901M1H Max. Airflow Max. Static Pressure SPL Operating Temperature Expected Life Rated Voltage Operating Voltage Range Frequency (Note) Rated Current Rated Input Rated Speed V V A W min-1 m/min CFM Pa inchHOdB(A) h Hz 100 to 240 90 to 264 50/60 0.08 0.06 4.5 3.0 3,850 3,100 1.50 1.18 53.0 41.7 90 56 0.36 0.22 40 33 -20 to 75 60,000/60 Note: 50/60 Hz compatible. Overheating protection function Protection Functions: If the fan blades are restricted, an overcurrent occurs and leads to a rise in the fan coil temperature. This can result in reduced performance, damage, or a fire. To prevent this from occurring, SANYO DENKI's fans incorporate an overheating protection function. Burnout protection function at locked rotor condition Current cutoff system (ACDC fan only) If the fan blades are restricted, the coil current is cut off at regular cycles to prevent overheating of the coil. When the hindrance is removed, the fan restarts automatically. 399 Dimensionsunit: mm(With ribs) without Sensor 920.5 82.50.3 4-4.30.3 Mounting Hole (4) 82.50.3 (4) 380.5 920.5 Rotating Direction Airflow Direction with Low-speed sensor Connector: Tyco Electronics Electronics 171822-2 Sensor output: Yellow Pin2 Tyco 171822-2(Pin1 Pin.1 Pin.2-: Black) - Contact: TycoTyco Electronics 170262-1 Electronics 170262-1 * Recommended connectors and contacts are listed below. Connector: Tyco Electronics Electronics172211-2 172211-2 Tyco Contact: Tyco Tyco Electronics 170376-1 Electronics 170376-1 ACDC Fan 92mm 82.50.3 920.5 AC 10010 4-4.30.3 Mounting Hole Lead Wire AWG24 AWG24 UL1007 UL1007 (4) 82.50.3 (4) 380.5 920.5 Rotating Direction Airflow Direction Reference Dimensions of Mounting Holes and Vent Openingunit: mm Inlet side Outlet side 90.5 90.5 4-4.5 5 82.50.3 90.5 82.50.3 82.50.3 10 97 90.5 4-4.5 82.50.3 400 ACDC Fan 92 San Ace 92AD mm sq. 92x92x38mm Mass250g Optionsunit: mm Finger Guards Model109-099C Resin Finger Guards Color Surface treatment Nickel-chrome platingsilver Model109-1001G 921 Outlet side 4-4.30.3 4-20.5 921 82.50.3 0 99 1.5 120.5 0.5 4.30.3 1.6 1.6 9.8 3 87 5 70.5 82.50.3 1 .6 16 1 12g Mass Mass 22g Model109-099E 109-099H Resin Filter Kits Color Surface treatment Nickel-chrome platingsilver Cation electropaintingblack Model: 109-1001F13 (13PPI), 109-1001F20 (20PPI), 109-1001F30 (30PPI), 109-1001F40 (40PPI) 96.5 1 Inlet side, Outlet side 1 82.5 0.3 0 7 99 96.5 1 8 1.5 120.5- 0.5 4-4.3 0.3 82.5 0.3 5 4.30.3 1.6 1.6 10.5 0.5 16 . 4-9.5 0.5 .6 16 1 2 4-2 0.5 Mass 25g 29g Mass Plug Cord (Products compliant with Electrical Appliance and Material Safety Law, UL/CSA [c-UL] CERTIFIED) UL FILE No. E43202 Model489-1635-L10/489-1635-L21 10 8 Model 489-1635-L10 489-1635-L21 L 8 15.5 Pre-soldered 4 10 20 4 50 5 17 10 2 Wiring Harness for Sensor Model: 489-1636 100020 101 Pre-soldered Mass 9g 401 Power cord length (L) [mm] 1,000 2,100 Mass [g] 38 74 Airflow - Static Pressure Characteristics inch H2OPa 0.3 inch H2OPa 60 100 Static Pressure Static Pressure 0.4 80 100 to 240 V50/60Hz 50/60 Hz 100240V 60 0.2 40 0.1 20 0 0 0.4 0 10 0.8 20 30 1.2 40 100 to 240 V50/60Hz 50/60 Hz 100240V 40 0.15 30 0.10 20 0.05 10 0 1.6m3/min 50 50 0.20 0 0 CFM 0.4 10 Airflow 0.8 20 30 1.2 40 1.6m3/min 50 CFM Airflow 9AD0901H12 9AD0901H1H 9AD0901M12 9AD0901M1H Standard with Sensor AC Power supply AC Power supply Wiring Diagram Yellow 10 mA MAX. +27.6 V MAX. Pull-up resistor Senser output Black GND (0 V) AC FAN FAN Photocoupler Typical standard model: 9AD0901H1H Output circuit: Open collector ACDC Fan 92mm Specifications for Low-speed Sensors Sensor scheme VCE27.6 V DC MAX. Ic10 mA MAX.VCE (SAT) 1.0 V MAX. Inside of DC fan Example 1: when steady running Fan power Pull-up voltage 27.6 V DC MAX. Trip point Fan speed Pull-up resistor Photocoupler Sensor Ic10 mA MAX. Sensor output (VCE) Startup delay Sensor output Detection delay H H L - VCE (SAT) = 1.0 V MAX. Example 2: when the rotor is locked when the fan motor is turned on and released after the start-up delay time. Fan power Trip point Fan speed Startup delay Sensor output Detection delay H H L 9AD0901H1H 9AD0901M1H Startup delay: 183 sec. Startup delay: 363 sec. Detection delay: 3 sec. MAX. Detection delay: 3 sec. MAX. Trip point: 1,700 min-1 Trip point: 850 min-1 402