https://www.phoenixcontact.com/us/products/2906280 Type 2 surge protection device-VAL-US 60/O-FM-2906280 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Surge arresters consisting of base element and protective connector with high-capacity varistor, for mounting on NS 35/7.5, 1-channel Your advantages Plug-in direction parallel to the conductor axis Versions with and without floating remote indication contact Rack-mount 2U panel applications Accepts Type 1 and Type 2 VAL-MS plugs. Coding when protective plug is inserted for the first time DIN rail mounting Key Commercial Data Packing unit 1 pc GTIN GTIN 4055626063058 Weight per Piece (excluding packing) 145.830 g Custom tariff number 85363090 Country of origin Germany Technical data Dimensions Height 77.1 mm Width 17.6 mm Depth 89.2 mm 03/28/2021Page1/15 https://www.phoenixcontact.com/us/products/2906280 Type 2 surge protection device-VAL-US 60/O-FM-2906280 Technical data Ambient conditions Degree of protection IP20 IP20 (only when all terminal points are used) Ambient temperature (operation) -40 C ... 80 C Ambient temperature (storage/transport) -40 C ... 80 C Altitude max. 2000 m Permissible humidity (operation) 5 % ... 95 % Shock (operation) 25g (Half-sine / 11 ms / 3x X, Y, Z) Vibration (operation) 5g (10 ... 500 Hz / 2.5 h / X, Y, Z) General IEC test classification II T2 EN type T2 Mode of protection L-PEN (L+) - (L-) (L-) - PE (L+) - PE Mounting type DIN rail: 35 mm Color black Housing material PBT Degree of pollution 2 Flammability rating according to UL 94 V0 Type DIN rail module, two-section, divisible Number of positions 1 Surge protection fault message Optical, remote indicator contact Protective circuit Nominal voltage UN 60 VDC -48 VDC (RRH) Nominal frequency fN 50 Hz (60Hz) Maximum continuous voltage UC 75 VAC 100 VDC Maximum continuous operating voltage UC (L-N) 75 VAC 100 VDC Maximum continuous operating voltage UC (L-PEN) 75 VAC 100 VDC Rated load current IL 80 A Residual current IPE 0.45 mA 03/28/2021Page2/15 https://www.phoenixcontact.com/us/products/2906280 Type 2 surge protection device-VAL-US 60/O-FM-2906280 Technical data Protective circuit Standby power consumption PC 35 mVA Nominal discharge current In (8/20) s 15 kA Nominal discharge current In (8/20) s (L-N) 15 kA Nominal discharge current In (8/20) s (L-PEN) 15 kA Maximum discharge current Imax (8/20) s 40 kA Maximum discharge current Imax (8/20) s (L-N) 40 kA Maximum discharge current Imax (8/20) s (L-PEN) 40 kA Short-circuit current rating ISCCR 25 kA Voltage protection level Up 0.55 kV Voltage protection level Up (L-N) 0.55 kV Voltage protection level Up (L-PEN) 0.55 kV Residual voltage Ures 0.55 kV (at In) 0.425 kV (at 10 kA) 0.325 kV (at 5 kA) 0.275 kV (at 3kA) TOV behavior at UT 100 VAC (5s / withstand mode) TOV behavior at UT (L-N) 100 VAC (5s / withstand mode) TOV behavior at UT (L-PEN) 100 VAC (5s / withstand mode) Response time tA 25 ns Response time tA (L-N) 25 ns Response time tA (L-PEN) 25 ns Max. backup fuse with V-type through wiring 80 A AC (gG) Max. backup fuse with branch wiring 125 A AC (gG) Indicator/remote signaling Switching function Changeover contact Operating voltage 5 VAC ... 250 VAC 125 VAC (UL) 125 VDC (200 mA DC) Operating current 5 mA AC ... 1.5 A 1 A (UL) 1 A (30VDC) Connection method Screw connection Screw thread M2 Tightening torque 0.25 Nm 4 lbf-in. (UL) Stripping length 7 mm 03/28/2021Page3/15 https://www.phoenixcontact.com/us/products/2906280 Type 2 surge protection device-VAL-US 60/O-FM-2906280 Technical data Indicator/remote signaling Conductor cross section flexible min. 0.14 mm Conductor cross section flexible max. 1.5 mm Conductor cross section solid min. 0.14 mm Conductor cross section solid max. 1.5 mm Conductor cross section AWG 28 ... 16 30 ... 14 (UL) Connection data Connection method Biconnect terminal blocks Screw thread M5 Tightening torque 3 Nm ... 4.5 Nm (UL) 27 lbf-in. ... 40 lbf-in. (UL) Stripping length 16 mm Conductor cross section flexible min. 1.5 mm Conductor cross section flexible max. 25 mm Conductor cross section solid min. 1.5 mm Conductor cross section solid max. 35 mm Conductor cross section AWG 15 ... 2 (IEC) 10 ... 2 (UL) Connection method Screw connection Screw thread M5 Tightening torque 4.5 Nm 30 lbf-in. (UL) Stripping length 16 mm Conductor cross section flexible min. 1.5 mm Conductor cross section flexible max. 25 mm Conductor cross section solid min. 1.5 mm Conductor cross section solid max. 35 mm Conductor cross section AWG 15 ... 2 10 ... 2 (UL) UL specifications SPD Type 4CA Maximum continuous operating voltage MCOV 75 VAC Maximum continuous operating voltage MCOV (L-N) 75 VAC Maximum continuous operating voltage MCOV (L-G) 75 VAC Maximum continuous operating voltage MCOV (L+) - (L-) 100 VDC Maximum continuous operating voltage MCOV (L+/L-) - G 100 VDC 03/28/2021Page4/15 https://www.phoenixcontact.com/us/products/2906280 Type 2 surge protection device-VAL-US 60/O-FM-2906280 Technical data UL specifications Nominal voltage 60 VDC Mode of protection L-L L-G (L+) - (L-) (L+) - G (L-) - G Power distribution system Single phase Voltage protection rating VPR 500 V Voltage protection rating VPR (L-N) 0.5 kV Voltage protection rating VPR (L+) - (L-) 0.33 kV Voltage protection rating VPR (L+/L-) -G 0.33 kV Measured limiting voltage MLV (L-N) 630 V Measured limiting voltage MLV 630 V Nominal discharge current In 10 kA Nominal discharge current In (L-N) 10 kA Nominal discharge current In (L+) - (L-) 10 kA Nominal discharge current In (L+/L-) - G 10 kA UL indicator/remote signaling Operating voltage 125 VAC Operating current 1 A AC Tightening torque 2 lbf-in. ... 4 lbf-in. Conductor cross section AWG 30 ... 14 UL connection data Conductor cross section AWG 10 ... 2 Tightening torque 30 lbf-in. Standards and Regulations Standards/regulations EN61643-11/A11 2007 Environmental Product Compliance China RoHS Environmentally Friendly Use Period = 50 years For details about hazardous substances go to tab "Downloads", Category "Manufacturer's declaration" Drawings 03/28/2021Page5/15 https://www.phoenixcontact.com/us/products/2906280 Type 2 surge protection device-VAL-US 60/O-FM-2906280 Dimensional drawing Circuit diagram 21,22 L 17,6 12 14 11 FM 54,02 76 29,79 77,06 5,02 45,6 N / PEN 40,93 103,35 Classifications eCl@ss eCl@ss 10.0.1 27130805 eCl@ss 11.0 27130805 eCl@ss 4.0 27130800 eCl@ss 4.1 27130800 eCl@ss 5.0 27130800 eCl@ss 5.1 27130800 eCl@ss 6.0 27130800 eCl@ss 7.0 27130805 eCl@ss 9.0 27130805 ETIM ETIM 6.0 EC000941 ETIM 7.0 EC000941 UNSPSC UNSPSC 13.2 39121620 UNSPSC 18.0 39121620 UNSPSC 19.0 39121620 UNSPSC 20.0 39121620 UNSPSC 21.0 39121620 Approvals Approvals Approvals UL Recognized / cUL Recognized / cULus Recognized 03/28/2021Page6/15 https://www.phoenixcontact.com/us/products/2906280 Type 2 surge protection device-VAL-US 60/O-FM-2906280 Approvals Ex Approvals Approval details UL Recognized http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 330181 cUL Recognized http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 330181 cULus Recognized Accessories Accessories Bridge Wiring bridge-MPB 18/1- 2-2809209 Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 2-pos. Wiring bridge-MPB 18/1- 3-2809212 Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 3-pos. 03/28/2021Page7/15 https://www.phoenixcontact.com/us/products/2906280 Type 2 surge protection device-VAL-US 60/O-FM-2906280 Accessories Wiring bridge-MPB 18/1- 4-2809225 Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 4-pos. Wiring bridge-MPB 18/1- 6-2748564 Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 6-pos. Wiring bridge-MPB 18/1- 7 BU-2856278 Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 7-pos., color: Blue Wiring bridge-MPB 18/1- 8 BU-2858470 Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 8-pos., color: Blue Wiring bridge-MPB 18/1- 8-2748577 Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 8-pos. 03/28/2021Page8/15 https://www.phoenixcontact.com/us/products/2906280 Type 2 surge protection device-VAL-US 60/O-FM-2906280 Accessories Wiring bridge-MPB 18/1- 9-2748580 Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 9-pos. Wiring bridge-MPB 18/1-12-2748593 Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 12-pos. Wiring bridge-MPB 18/1-57-2809238 Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 57-pos. Wiring bridge-MPB 18/3- 6-2809241 Wiring bridge for modules with connecting pitch 17.5 mm, 3-phase, 6-pos. Wiring bridge-MPB 18/4- 8-2809283 Wiring bridge for modules with connecting pitch 17.5 mm, 4-phase, 8-pos. 03/28/2021Page9/15 https://www.phoenixcontact.com/us/products/2906280 Type 2 surge protection device-VAL-US 60/O-FM-2906280 Accessories Wiring bridge-MPB 18/4-12-2809296 Wiring bridge for modules with connecting pitch 17.5 mm, 4-phase, 12-pos. Wiring bridge-MPB F200X16/ 1GS-2818339 Wiring bridge flexible, diameter 16 mm, with a fork-type cable lug on one side, length: 200 mm Wiring bridge-MPB F400X16/ 1GS-2818342 Wiring bridge flexible, diameter 16 mm, with a fork-type cable lug on one side, length: 400 mm Wiring bridge-MPB F600X16/ 1GS-2818355 Wiring bridge flexible, diameter: 16 mm, with a fork-type cable lug on one side, length: 600 mm Wiring bridge-MPB F600X16/ 1GS-2818355 Wiring bridge flexible, diameter: 16 mm, with a fork-type cable lug on one side, length: 600 mm 03/28/2021Page10/15 https://www.phoenixcontact.com/us/products/2906280 Type 2 surge protection device-VAL-US 60/O-FM-2906280 Accessories Wiring bridge-MPB F400X16/ 1GS-2818342 Wiring bridge flexible, diameter 16 mm, with a fork-type cable lug on one side, length: 400 mm Wiring bridge-MPB F200X16/ 1GS-2818339 Wiring bridge flexible, diameter 16 mm, with a fork-type cable lug on one side, length: 200 mm Wiring bridge-MPB 18/1-10/1.0.0-2830443 Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 10 pitches with contact sequence 1-0-0 Wiring bridge-MPB 18/4-12-2809296 Wiring bridge for modules with connecting pitch 17.5 mm, 4-phase, 12-pos. Wiring bridge-MPB 18/4- 8-2809283 Wiring bridge for modules with connecting pitch 17.5 mm, 4-phase, 8-pos. 03/28/2021Page11/15 https://www.phoenixcontact.com/us/products/2906280 Type 2 surge protection device-VAL-US 60/O-FM-2906280 Accessories Wiring bridge-MPB 18/3- 6-2809241 Wiring bridge for modules with connecting pitch 17.5 mm, 3-phase, 6-pos. Wiring bridge-MPB 18/1-57-2809238 Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 57-pos. Wiring bridge-MPB 18/1-12-2748593 Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 12-pos. Wiring bridge-MPB 18/1- 9-2748580 Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 9-pos. Wiring bridge-MPB 18/1- 8-2748577 Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 8-pos. 03/28/2021Page12/15 https://www.phoenixcontact.com/us/products/2906280 Type 2 surge protection device-VAL-US 60/O-FM-2906280 Accessories Wiring bridge-MPB 18/1- 6-2748564 Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 6-pos. Wiring bridge-MPB 18/1- 4-2809225 Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 4-pos. Wiring bridge-MPB 18/1- 3-2809212 Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 3-pos. Wiring bridge-MPB 18/1- 2-2809209 Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 2-pos. Device marking Zack marker strip-ZBN 18:UNBEDRUCKT-2809128 Zack marker strip, Strip, white, unlabeled, can be labeled with: CMS-P1-PLOTTER, PLOTMARK, mounting type: snap into tall marker groove, for terminal block width: 18 mm, lettering field size: 18 x 5 mm, Number of individual labels: 5 03/28/2021Page13/15 https://www.phoenixcontact.com/us/products/2906280 Type 2 surge protection device-VAL-US 60/O-FM-2906280 Accessories Feed-through terminal block Feed-through terminal block-DK-BIC-35-2749880 Feed-through terminal block for VAL and FLT applications Labeled device marker Marker for terminal blocks-ZBN 18,LGS:ERDE-2749589 Marker for terminal blocks, Strip, white, labeled, horizontal: Grounding symbol, mounting type: snap into tall marker groove, for terminal block width: 18 mm, lettering field size: 18 x 5 mm, Number of individual labels: 5 Marker for terminal blocks-ZBN 18,LGS:L1-N,ERDE-2749576 Marker for terminal blocks, Strip, white, labeled, horizontal: L1, L2, L3, N, GND, mounting type: snap into tall marker groove, for terminal block width: 18 mm, lettering field size: 18 x 5 mm, Number of individual labels: 5 Marker pen Marker pen-B-STIFT-1051993 Marker pen, for manual labeling of unprinted Zack strips, smear-proof and waterproof, line thickness 0.5 mm Spare parts 03/28/2021Page14/15 https://www.phoenixcontact.com/us/products/2906280 Type 2 surge protection device-VAL-US 60/O-FM-2906280 Accessories Type 2 surge protection plug-VAL-US-48/40-P-2910333 UL Recognized type 2 SPD and IEC type 2 surge protection plug with a varistor and thermal disconnect for use with VALUS base elements, mechanical and visual fault warning Type 2 surge protection base element-VAL-MS-T1/T2 BE/O-FM-2905652 Base element for type 1/2 arresters from the VALVETRAB MS T1/T2 product range, with remote indication contact. Version: 1-channel Phoenix Contact 2021 (c) - all rights reserved http://www.phoenixcontact.com 03/28/2021Page15/15