Solid State Relay Potter & Brumfield IAC Series AC Input Module File E29244 Users should thoroughly review the technical data before selecting a product part number. It is recommended that users also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. Engineering Data Features Switch Form: 1 Form A (SPST-NO) Duty: Continuous. Operating Temperature: -30C to +80C. Storage Temperature: -30C to 100C. Potting Compound Flammability: UL94V-0. Approximate Weight: 1.38 oz. (35g). * Industry standard package and pin-out. * Color coded by function. * 4000V rms optical isolation. * High immunity to false operation. * Series compatible. * Compatible with 2IO series mounting boards. Ordering Information Typical Part Number > IAC -5 A 1. Basic Series: IAC = AC input module - yellow case 2. Logic Voltage: 5 = 5VDC 15 = 15VDC 24 = 24VDC 3. Input: Blank = 120VAC input (90-140VAC) * * A = 240VAC input (180-280VAC) * * E = 18-36VAC input * * * * Is not polarity sensitive. Our authorized distributors are more likely to maintain the following items in stock for immediate delivery. IAC-5 IAC-5A IAC-5E IAC-15 IAC-24 Input Specifications Parameter Control Voltage Range VIN Must Operate Voltage VIN(OP) Must Release Voltage VIN(REL) Max. Input Current Input Resistance 1 02-2019, Rev. 0219 www.te.com (c) 2015 Tyco Electronics Corporation, a TE Connectivity Ltd. company Conditions @VIN=Max. IAC-5 IAC-15 IAC-24 Units VAC VAC VAC mA Ohms Min. 90 Typ. 120 60 Datasheets and product specification according to IEC 61810-1 and to be used only together with the `Definitions' section. Max. 140 90 IAC-5A IAC-15A IAC-24A Min. 180 Typ. 240 Max. 280 180 60 1-5 IAC-5E IAC-15E IAC-24E Min. 18 Typ. 24 Max. 36 18 10 1-8 Current Regulator Datasheets and product data is subject to the terms of the disclaimer and all chapters of the `Definitions' section, available at http://relays.te.com/definitions 0.2 - 2.0 Datasheets, product data, `Definitions' section, application notes and all specifications are subject to change. Solid State Relay Potter & Brumfield IAC Series(Continued) AC Input Module Output Specifications (@ +25C unless otherwise specified) Parameter Maximum Output Voltage Maximum Output Current Maximum Output Leakage Current Maximum Output Voltage Drop Logic Supply Voltage VCC Logic Supply Current Turn-On Time (Nominal) Turn-Off Time (Nominal) Output Type (Open Collector) Conditions VOUT=Max. ISINK=50mA VCC=Max. ISINK=25mA ISINK=25mA Units VDC mADC mA VDC VDC mADC ms ms IAC Operating Diagram IAC-5 IAC-5A IAC-5E Min. Typ. Max. 30 50 10 0.2 3 5 6 15 20 30 Normally Open(SINKING) IAC-15 IAC-15A IAC-15E Min. Typ. Max. 30 50 10 0.2 12 15 18 15 20 30 Normally Open(SINKING) IAC-24 IAC-24A IAC-24E Min. Typ. Max. 30 50 10 0.2 20 24 30 15 20 30 Normally Open(SINKING) PCB Layout Outline Dimensions Note : Extra nut and washer will be provided on the screw, which will goes under PCB to fix the relay. Hex Nut S= 6.35 (width across flats), Thickness = 2.40 Washer = OD : 4.850.25, ID: 2.750.15, Thickness = 0.55 02-2019, Rev. 0219 www.te.com (c) 2015 Tyco Electronics Corporation, a TE Connectivity Ltd. company Datasheets and product specification according to IEC 61810-1 and to be used only together with the `Definitions' section. Datasheets and product data is subject to the terms of the disclaimer and all chapters of the `Definitions' section, available at http://relays.te.com/definitions Datasheets, product data, `Definitions' section, application notes and all specifications are subject to change. 2