OUTPUT SPECIFICATIONS
Output power 10 Watts max
Voltage accuracy Full load and nominal Vin ± 2%
Minimum load (Note 1) 10% of FL
Line regulation LL to HL at Full Load ± 1%
Load regulation 10% to 100% FL Single
Dual ± 1%
± 2%
Cross regulation Asymmetrical load 25% / 100% FL ± 5%
Ripple and noise 20MHz bandwidth Single
Dual 50mVp-p
75mVp-p
Temperature coefficient 0.02% / ºC, max
Transient response re covery time 25% load step change 500uS
Over voltage protection
Zener diode clamp
3.3V output
5V output
12V output
15V output
3.9V
6.2V
15V
18V
Over load protection % of FL at nominal input 150% typ
Short circuit protecti on Hiccup, automatics recovery
INPUT SPECIFICATIONS
Input voltage range
FDC10
FDC10-W
12V nominal input
24V nominal input
48V nominal input
24V nominal input
48V nominal input
9 – 18VDC
18 – 36VDC
36 – 75VDC
9 – 36VDC
18 – 75VDC
Input filter Pi type
Input surge voltage
100mS max 12V input
24V input
48V input
36VDC
50VDC
100VDC
Input reflected ripple (Note 2) Nominal Vin and full load 30mAp-p
Start up time Nominal Vin and constant resistor load 20mS typ
Remote ON/OFF (Note 3)
(Positive logic)
(Negative logic)
Remote off input current
DC-DC ON
DC-DC OFF
DC-DC ON
DC-DC OFF
Nominal Vin
Open or 3.5V < Vr < 12V
Short or 0V < V r < 1.2V
Short or 0V < V r < 1.2V
Open or 3.5V < Vr < 12V
2.5mA
GENERAL SPECIFICATIONS
Efficiency See table
Isolation voltage 1600VDC, min
Isolation resistance 109ohms, min
Isolation capacitance 300pF, ma
Switching frequency 300KHz, typ
Approvals and standard IEC60950, UL1950, EN60950
Case material Nickel-coated coppe
Base material Non-conductive black plastic
Potting material Epoxy (UL94-V0)
Dimensions 2.00 X 1.00 X 0.40 Inch
(50.8 X 25.4 X 10.2 mm)
Weight 27g (0.95oz)
MTBF (Note 4) 1.976 x 106 hrs
ENVIRONMENTAL SPECIFICATIONS
Operating temperature range
(Reference derating curve)
Standard
M1 (Note 5)
M2 (W series)
-25ºC ~ +85ºC (with derating)
-40ºC ~ +85ºC (non-derating)
-40ºC ~ +85ºC (with derating)
Maximum case temperature +100ºC
Storage temperatu re range -55ºC ~ +105ºC
Thermal impedance (Note 6) Nature convection
Nature convection with heat-sink 12ºC/wat
10ºC/wat
Thermal shock MIL-STD-810D
Vibration 10~55Hz, 2G, 30minutes along X,Y and Z
Relative humidity 5% to 95% RH
EMC CH ARACT ERI STI CS
Conducted emi ssions EN55022 Level
Radiated emissions EN55022 Level
ESD EN61000-4-2 Perf. Criteria
Radiated immunity EN61000-4-3 Perf. Criteria
Fast transient EN61000-4-4 Perf. Criteria
Surge EN61000-4-5 Perf. Criteria
Conducted immunity EN61000-4-6 Perf. Criteria
The FDC10 and FDC10-W series off er 10 watts of output power from a 2 x 1 x 0.4 inch
package. FDC10 series have 21 w ide input voltage of 9-18, 18-36 and 36-75VDC.
FDC10-W se ries have 4:1 ultra wide input voltage of 9-36 and 18-75VDC. The FDC10 and
FDC10-W features 1600VDC of isolation, short-circuit and over-voltage protection, as well
as six sided shielding. The safety approval of EN60950 and UL1950. All models are
particularly suited to t elecommunicat ions, indust rial, mobile telecom and test equi pment
applications. According the extended operation temperature range, there are “M1” and “M2”
version for special application.
TECHNICAL SPECIFICATION All specifications are typical at nominal input, full load and 25ºC otherwise noted.
UL E193009
TUV R2054609
CB JPTUV-001422
CE MARK
• 10 WATT S OUTPUT POWER
• 2:1 AND 4:1 WIDE INPUT VOLTAGE RANGE
• INTERN ATION AL SAFETY STAND ARD APPRO VAL
• SIX-SI DED CO NTI NUO US SHIE LD
• HIGH EFFICIENCY UP TO 86%
• STANDARD 2” X 1” X 0.4” PACKAGE
• FIXED SWITCHING FREQUENC Y