Ordering information AC-DC Power Supplies Medical Type GHA300F GH 1 A 2 300 3 F 4 Example recommended EMI/EMC filter EAC-10-472 R High voltage pulse noise type : EAP series Low leakage current type : EAM series * A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply. -OO -O 5 6 1 Series name 2 Single output 3 Output wattage 4 Universal input 5 Output voltage 6 Optional *6 T3 : mounting hole M3 J1 : VH(J.S.T.)connector type J3 : Horizontal input connector VH(J.S.T.)connector type R3 : with Subfeatures (5VAUX,12VAUX,Remote, Power good) Specification is changed at option, refer to Instruction manual. This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, please handle the unit with care *Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations. MODEL MAX OUTPUT WATTAGE[W] Forced air at 50C DC OUTPUT Convection at 40C at 50C GHA300F-12 300 12V 25A 12V 8.4A 12V 4.5A GHA300F-24 300 24V 12.5A 24V 4.2A 24V 2.2A GHA300F-48 302.4 48V 6.3A 48V 2.1A 48V 1.1A SPECIFICATIONS MODEL VOLTAGE[V] CURRENT[A] ACIN 120V ACIN 230V FREQUENCY[Hz] ACIN 120V ACIN 230V POWER FACTOR ACIN 120V (Io=100%) ACIN 230V ACIN 120V INRUSH CURRENT[A] ACIN 230V LEAKAGE CURRENT[mA] VOLTAGE[V] Forced air CURRENT[A] Convection LINE REGULATION[mV] *4 LOAD REGULATION[mV] *4 0 to +50C RIPPLE[mVp-p] *1 -20 to 0C 0 to +50C OUTPUT RIPPLE NOISE[mVp-p]*1 -20 to 0C 0 to +50C TEMPERATURE REGULATION[mV] -20 to +50C *2 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION[V] PROTECTION AUX1 (12V1A) CIRCUIT AND AUX2 (5V1A) OTHERS REMOTE ON/OFF PowerGood INPUT-OUTPUT-RC-AUX *7 INPUT-FG ISOLATION *7 OUTPUT-RC-AUX-FG *7 OUTPUT-RC-AUX OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE ENVIRONMENT VIBRATION IMPACT INPUT EFFICIENCY[%] SAFETY AND AGENCY APPROVALS NOISE CONDUCTED NOISE REGULATIONS HARMONIC ATTENUATOR CASE SIZE/WEIGHT OTHERS COOLING METHOD GHA300F-12 GHA300F-24 GHA300F-48 AC90 - 264 1f (output derating is required at AC90V -115V *3) 3.3typ 1.8typ 50 / 60 (47 - 63) 89typ 90typ 90typ 91typ 92typ 92typ 0.95typ 0.90typ 20typ (Io=100%) (At cold start) (Ta=25C) 40typ (Io=100%) (At cold start) (Ta=25C) 0.125/0.250max (ACIN 120V/240V 60Hz,Io=100%, According to IEC60601-1) 12 24 48 25.0 12.5 6.3 4.5 2.2 1.1 48max 96max 192max 100max 150max 240max 240max 240max 300max 320max 320max 400max 300max 300max 480max 360max 360max 500max 120max 240max 480max 150max 290max 600max 48max 96max 192max 500typ (ACIN 120V, Io=100%) 16typ (ACIN 120V, Io=100%) 10.80 to 13.20 21.60 to 26.40 43.20 to 52.80 12.00 to 12.48 24.00 to 24.96 48.00 to 49.92 Works over 105% of rating and recovers automatically 13.80 to 16.80 27.60 to 33.60 55.20 to 67.20 Optional Optional Optional Optional AC4,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) 2MOPP AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) 1MOPP AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature) AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature) -20 to +70C, 20 - 90%RH (Non condensing), 3,000m (10,000feet) max *3 -30 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL60950-1, ANSI/AAMI ES60601-1, C-UL(CSA60950-1, CAN/CSA60601-1), EN60950-1, EN60601-1 3rd, Complies with DEN-AN, IEC60601-1-2 4th Ed. Complies with FCC-B, VCCI-B, CISPR11-B, CISPR22-B, EN55011-B, EN55022-B Complies with IEC61000-3-2 (class A) *5 76.2X35X127mm [3.0X1.4X5.0 inches] (WXHXD) / 400g max Convection, Forced air (Require external fan) *1 This is the value that measured on measuring board with capacitor of 22mF at 150mm from output terminal. Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN: RM103). *2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. *3 Derating is required. *4 Please contact us about dynamic load and input response. *5 Please contact us about another class. GHA-2 *6 *7 * * * * * Specification is changed at option, refer to Instruction Manual. Applicable when AUX and remote control (optional) is added. To meet the specifications. Do not operate over-loaded condition. Sound noise may be generated by power supply in case of pulse load. Parallel operation is not possible. Forced air cooling is required to output up to MAX OUTPUT WATTAGE. Bottom layer P.C.B has electric potential which is required isolation from FG by clearance or creepage as the safety design issue. GHA300F Features -High Power density:14.3W/inch3 -High efficiency 92 typ (Input Voltage 230V, Output Voltage 24V) - "X "standard footprint -Fits 1U applications -Industrial and Medical safety approvals -Low leakage current -With Remote On/Off (Optional) -With AUX1 (12V), AUX2 (5V) (Optional) -No minimum load is required Block diagram AC IN 90 - 264V FUSE 250V10A 2 BOOSTER INDUCTOR NOISE FILTER CURRENT SENSING INRUSH CURRENT LIMIT RECTIFIER INVERTER FG RECTIFIER AND FILTER CONTROL TRANSFORMER INVERTER CURRENT SENSING INTERNAL REGULATOR RECTIFIER AND FILTER AUX1(12V 1A) RECTIFIER AND FILTER DC OUT CONTROL Photocoupler OVER VOLTAGE PROTECTION Photocoupler PG(POWER GOOD) CONTROL RC(REMOTE ON/OFF) TRANSFORMER RECTIFIER AND FILTER AUX2(5V 1A) External view * External size of option J3 is different from standard model and refer to 5 Option and Others of instruction manual for details. 4-f3.4(with Mounting Holes M3) Mounting Holes 115.6 0.5 5.7 [4.55] [0.22] Standard CN101 CN101 R3 1 AC(L) 2 1 8 7 [0.22] [0.71] 18.0 17.0 [0.67] [4.89] Voltage adjust 127.0 [5.00] 08-50-0105 08-65-0114 Molex * 51110-0851 50394-8051 B2P3-VH VHR-3N CN501 B8B-PHDSS SVH-21T-P1.1 J.S.T. PHDR-08VS SPHD-002T-P0.5 Mating connector Terminal Mfr - 170603-2 Tyco Electronics 250 Series Pin No. Input 1 AC(L) 2 3 AC(N) [0.96] 24.5 [0.65] 16.5 [1.38] 35 Tolerance 1 [0.04] Weight : 400g max There is a total of four attachment holes. This power supply requires mounting on metal standoffs 5mm in height. (Insulating sheet is required if you do not use a spacer). Dimensions in mm, [ ]=inches Screw tightening torque : (TB501, 502) : 1.5N-m max Mounting toque : 0.6N-m max Avoid contact between TB501 and 502 wiring with mounting parts. Option : -J1 : (J.S.T) connector type. Refer to Instruction Manual 5. Mfr Name plate - with Subfeatures(Optional) 124.1 Terminal *Please note the pin position No.1 is different from Molex. 119.7 [4.71] CN101 FG CN501 [1.50] CN101 AC(N) 38.0 [2.55] [3.00] 64.8 0.5 3 OUTPUT(-) FG 5.7 76.2 TB502 CN101 J1R3 OUTPUT(+) A-41671-A03A197-2 09-50-8031 CN501 087831-0820 J1 TB501 Mating connector Connector Pin No. Function 1 AUX1 : AUX1 (12V1A) 2 AUX1G : AUX1 (GND) 3 RC : REMOTE ON/OFF 4 RCG : REMOTE ON/OFF (GND) 5 PG : Power good 6 PGG : Power good (GND 7 AUX2 : AUX2 (5V1A) 8 AUX2G : AUX2 (GND) 2 1 8 7 CN501 GHA-3 Ordering information AC-DC Power Supplies Medical Type GHA500F GH 1 A 2 500 3 F 4 Example recommended EMI/EMC filter EAC-10-472 R High voltage pulse noise type : EAP series Low leakage current type : EAM series * A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply. This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, please handle the unit with care *Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations. MODEL MAX OUTPUT WATTAGE[W] Forced air at 50C Convection at 40C DC OUTPUT at 50C conduction at 0C cooling at 50C GHA500F-12 500.4 12V 41.7A 12V 12.5A 12V 9.2A 12V 30.0A 12V 16.7A GHA500F-15 501 15V 33.4A 15V 10.0A 15V 7.4A 15V 24.0A 15V 13.4A GHA500F-24 504 24V 21.0A 24V 6.3A 24V 4.6A 24V 15.0A 24V 8.4A GHA500F-30 501 30V 16.7A 30V 5.0A 30V 3.7A 30V 12.0A 30V 6.7A -OO -O 5 6 1 Series name 2 Single output 3 Output wattage 4 Universal input 5 Output voltage 6 Optional *6 T3 : mounting hole M3 J1 : VH(J.S.T.)connector type J3 : Horizontal input connector VH(J.S.T.)connector type R3 : with Subfeatures (5VAUX,12VAUX,Remote, Power good) P : Parallel Operation Specification is changed at option, refer to Instruction manual. GHA500F-48 504 48V 10.5A 48V 3.2A 48V 2.3A 48V 7.5A 48V 4.2A GHA500F-56 504 56V 9.0A 56V 2.7A 56V 1.9A 56V 6.4A 56V 3.6A SPECIFICATIONS MODEL VOLTAGE[V] CURRENT[A] ACIN 120V ACIN 230V FREQUENCY[Hz] INPUT OUTPUT PROTECTION CIRCUIT AND OTHERS ISOLATION ENVIRONMENT SAFETY AND NOISE REGULATIONS OTHERS ACIN 120V ACIN 230V POWER FACTOR ACIN 120V (Io=100%) ACIN 230V ACIN 120V INRUSH CURRENT[A] ACIN 230V LEAKAGE CURRENT[mA] VOLTAGE[V] Forced air CURRENT[A] Convection conduction cooling LINE REGULATION[mV] *4 LOAD REGULATION[mV] *4 0 to +50C RIPPLE[mVp-p] *1 -20 - 0C 0 to +50C RIPPLE NOISE[mVp-p]*1 -20 - 0C 0 to +50C TEMPERATURE REGULATION[mV] -20 to +50C *2 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION[V] AUX1 (12V1A) AUX2 (5V1A) REMOTE ON/OFF PowerGood INPUT-OUTPUT-RC-AUX *7 INPUT-FG *7 OUTPUT-RC-AUX-FG *7 OUTPUT-RC-AUX OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS CONDUCTED NOISE HARMONIC ATTENUATOR CASE SIZE/WEIGHT COOLING METHOD EFFICIENCY[%] GHA500F-12 GHA500F-15 GHA500F-24 GHA500F-30 GHA500F-48 GHA500F-56 AC90 - 264 1f (output derating is required at AC90V -115V *3) 5.4typ 2.9typ 50 / 60 (47 - 63) 88typ 90typ 90typ 90typ 90typ 90typ 90typ 92typ 92typ 92typ 92typ 92typ 0.95typ 0.90typ 20typ (Io=100%) (At cold start) (Ta=25C) 40typ (Io=100%) (At cold start) (Ta=25C) 0.125/0.250max (ACIN 120V/240V 60Hz,Io=100%, According to IEC60601-1) 12 15 24 30 48 56 41.7 33.4 21.0 16.7 10.5 9.0 9.2 7.4 4.6 3.7 2.3 1.9 16.7 13.4 8.4 6.7 4.2 3.6 48max 60max 96max 120max 192max 192max 100max 120max 150max 180max 240max 240max 240max 240max 240max 300max 300max 400max 320max 320max 320max 400max 400max 500max 300max 300max 300max 480max 480max 500max 360max 360max 360max 500max 500max 580max 120max 150max 240max 300max 480max 480max 150max 180max 290max 360max 600max 600max 48max 60max 96max 120max 192max 192max 500typ (ACIN 120V, Io=100%) 16typ (ACIN 120V, Io=100%) 10.80 to 13.20 13.50 to 16.50 21.60 to 26.40 27.00 to 31.50 43.20 to 52.80 52.00 to 56.00 12.00 to 12.48 15.00 to 15.30 24.00 to 24.96 30.00 to 31.20 48.00 to 49.92 55.00 to 56.00 Works over 105% of rating and recovers automatically 13.80 to 16.80 17.25 to 21.00 27.60 to 33.60 34.50 to 42.00 55.20 to 67.20 60.00 to 69.00 Optional Optional Optional Optional AC4,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) 2MOPP AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) 1MOPP AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature) AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature) -20 to +80C, 20 - 90%RH (Non condensing), 3,000m (10,000feet) max -30 to +80C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL60950-1, ANSI/AAMI ES60601-1, C-UL(CSA60950-1, CAN/CSA60601-1), EN60950-1, EN60601-1 3rd, Complies with DEN-AN, IEC60601-1-2 4th Ed. Complies with FCC-B, VCCI-B, CISPR11-B, CISPR22-B, EN55011-B, EN55022-B Complies with IEC61000-3-2 (class A) *5 76.2X35X127mm [3.0X1.4X5.0 inches] (WXHXD) / 420g max Convection, Forced air (Require external fan), Conduction cooling *1 This is the value that measured on measuring board with capacitor of 22mF at 150mm from output terminal. Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN: RM103). *2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. *3 Derating is required. *4 Please contact us about dynamic load and input response. GHA-4 *5 *6 *7 * * * * Please contact us about another class. Specification is changed at option, refer to Instruction Manual. Applicable when AUX and remote control (optional) is added. To meet the specifications. Do not operate over-loaded condition. Sound noise may be generated by power supply in case of pulse load. Parallel operation is available with -P option. Refer to 5.1on the instruction manual. Forced air cooling is required to output up to MAX OUTPUT WATTAGE. GHA500F Features -Wattage 500W max -High Power density:24.1W/inch3 -High efficiency 92 typ (Input Voltage 230V,Output Voltage 24V) -Conduction cooling - "X "standard footprint -Fits 1U applications -Industrial and Medical safety approvals -Low leakage current -With Remote On/Off (Optional) -With AUX1 (12V), AUX2 (5V) (Optional) -No minimum load is required Block diagram AC IN 90 - 264V FUSE 250V10A 2 BOOSTER INDUCTOR NOISE FILTER CURRENT SENSING INRUSH CURRENT LIMIT RECTIFIER INVERTER FG RECTIFIER AND FILTER CONTROL TRANSFORMER INVERTER CURRENT SENSING INTERNAL REGULATOR RECTIFIER AND FILTER AUX1(12V 1A) RECTIFIER AND FILTER DC OUT CONTROL Photocoupler OVER VOLTAGE PROTECTION Photocoupler PG(POWER GOOD) CONTROL RC(REMOTE ON/OFF) TRANSFORMER RECTIFIER AND FILTER AUX2(5V 1A) External view * External size of option J3 is different from standard model and refer to 5 Option and Others of instruction manual for details. 4-f3.4(with Mounting Holes M3) Mounting Holes [2.55] 3 CN101 AC(N) 1 AC(L) [0.22] [0.71] OUTPUT(-) 2 1 8 7 R3 CN501 087831-0820 CN101 Molex * 51110-0851 50394-8051 B2P3-VH VHR-3N CN501 B8B-PHDSS SVH-21T-P1.1 J.S.T. PHDR-08VS SPHD-002T-P0.5 *Please note the pin position No.1 is different from Molex. [0.67] 17.0 - Mating connector Terminal Mfr - 170603-2 Tyco Electronics 250 Series 119.7 [4.71] CN101 FG CN501 Mfr 08-50-0105 A-41671-A03A197-2 09-50-8031 08-65-0114 CN101 J1R3 18.0 [3.00] 64.8 0.5 TB502 Terminal Standard CN101 J1 OUTPUT(+) FG 5.7 with Subfeatures(Optional) 124.1 [4.89] Voltage adjust 127.0 [5.00] Pin No. Input 1 AC(L) 2 3 Name plate AC(N) Tolerance 1 [0.04] Weight : 420g max There is a total of four attachment holes. Base Plate : Aluminum Dimensions in mm, [ ]=inches Screw tightening torque : (TB501, 502) : 1.5N-m max Mounting toque : 0.6N-m max Avoid contact between TB501 and 502 wiring with mounting parts. Option : -J1 : (J.S.T) connector type. Refer to Instruction Manual 5. [0.96] 24.5 [0.65] Pin No. 16.5 35 [1.38] 76.2 TB501 [1.50] [4.55] 38.0 115.6 0.5 5.7 [0.22] Mating connector Connector Function 1 AUX1 : AUX1 (12V1A) 2 AUX1G : AUX1 (GND) 3 RC : REMOTE ON/OFF 4 RCG : REMOTE ON/OFF (GND) 5 PG : Power good 6 PGG : Power good (GND 7 AUX2 : AUX2 (5V1A) 8 AUX2G : AUX2 (GND) 2 1 8 7 CN501 GHA-5 Ordering information AC-DC Power Supplies Medical Type GHA300F-SNF GH 1 A 2 300 3 F -OO -SNFO 4 Example recommended EMI/EMC filter EAC-10-472 R High voltage pulse noise type : EAP series Low leakage current type : EAM series 5 6 1 Series name 2 Single output 3 Output wattage 4 Universal input 5 Output voltage 6 Optional *6 J1 : CN501 PH(J.S.T.)connector type Refer to the instruction manual 5.1. * A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply. *Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations. MODEL MAX OUTPUT WATTAGE[W] Forced air +50C DC OUTPUT GHA300F-12-SNF 300 12V 25.0A GHA300F-24-SNF 300 24V 12.5A GHA300F-48-SNF 302.4 48V 6.3A SPECIFICATIONS MODEL VOLTAGE[V] CURRENT[A] ACIN 120V ACIN 230V FREQUENCY[Hz] ACIN 120V ACIN 230V ACIN 120V POWER FACTOR (Io=100%) ACIN 230V ACIN 120V INRUSH CURRENT[A] ACIN 230V LEAKAGE CURRENT[mA] VOLTAGE[V] CURRENT[A] Forced air LINE REGULATION[mV] *4 LOAD REGULATION[mV] *4 0 to +50C RIPPLE[mVp-p] *1 -20 - 0C 0 to +50C RIPPLE NOISE[mVp-p]*1 OUTPUT -20 - 0C 0 to +50C TEMPERATURE REGULATION[mV] -20 to +50C *2 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION[V] PROTECTION AUX1 CIRCUIT AND AUX2 OTHERS REMOTE ON/OFF PowerGood INPUT-OUTPUT-RC-AUX INPUT-FG ISOLATION OUTPUT-RC-AUX-FG OUTPUT-RC-AUX OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE ENVIRONMENT VIBRATION IMPACT INPUT EFFICIENCY[%] SAFETY AND AGENCY APPROVALS NOISE CONDUCTED NOISE REGULATIONS HARMONIC ATTENUATOR CASE SIZE/WEIGHT OTHERS COOLING METHOD GHA300F-24-SNF GHA300F-48-SNF GHA300F-12-SNF AC90 - 264 1f (output derating is required at AC90V -115V *3) 3.3typ 1.8typ 50 / 60 (47 - 63) 88typ 89typ 89typ 90typ 91typ 91typ 0.95typ 0.90typ 20typ (Io=100%) (At cold start) (Ta=25C) 40typ (Io=100%) (At cold start) (Ta=25C) 0.125/0.250max (ACIN 120V/240V 60Hz,Io=100%, According to IEC60601-1) 12 24 48 25.0 12.5 6.3 48max 96max 192max 100max 150max 240max 240max 240max 300max 320max 320max 400max 300max 300max 480max 360max 360max 500max 120max 240max 480max 150max 290max 600max 48max 96max 192max 500typ (ACIN 120V, Io=100%) 16typ (ACIN 120V, Io=100%) 21.60 to 26.40 43.20 to 52.80 10.80 to 13.20 24.00 to 24.96 48.00 to 49.92 12.00 to 12.48 Works over 105% of rating and recovers automatically *7 27.60 to 33.60 55.20 to 67.20 13.80 to 16.80 10V 0.5A 5V 1A Possible, AUX2 is available Open corrector AC4,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) 2MOPP AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) 1MOPP AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature) AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature) -20 to +70C, 20 - 90%RH (Non condensing), 3,000m (10,000feet) max *3 -30 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL60950-1, ANSI/AAMI ES60601-1, C-UL(CSA60950-1, CAN/CSA60601-1), EN60950-1, EN60601-1 3rd, Complies with DEN-AN, IEC60601-1-2 4th Ed. Complies with FCC-B, VCCI-B, CISPR11-B, CISPR22-B, EN55011-B, EN55022-B Complies with IEC61000-3-2 (class A) *5 85.2X41X165.3mm [3.35X1.61X6.5 inches] (WXHXD) / 620g max Forced air *1 This is the value that measured on measuring board with capacitor of 22mF at 150mm from output terminal. Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN: RM103). *2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. *3 Derating is required. *4 Please contact us about dynamic load and input response. GHA-6 *5 Please contact us about another class. *6 Specification is changed at option, refer to Instruction Manual. *7 When output current more than rated, output will shut down after 5 seconds or more. Recycle input after 3 minutes to reset the protection. * To meet the specifications. Do not operate over-loaded condition. * Sound noise may be generated by power supply in case of pulse load. GHA300F-SNF Features -Full packaged desin united with GHA's features and addtional robastness.. -High efficiency 91% typ (Input voltage 230V,Output voltage 24V) -Optical for 1U applications -Medical and Industrial safety approvals -Low leakage current -Conformal coating -Single remote ON/OFF control for DC output, AUX1 and Fan. -Isolated dual AUX (AUX1 10V 0.5A, AUX2 5V 1A) Block diagram FUSE 250V10A AC IN 90 - 264V 2 BOOSTER INDUCTOR NOISE FILTER CURRENT SENSING INRUSH CURRENT LIMIT RECTIFIER INVERTER FG RECTIFIER AND FILTER CONTROL TRANSFORMER INVERTER CURRENT SENSING INTERNAL REGULATOR RECTIFIER AND FILTER AUX1(10V 0.5A) RECTIFIER AND FILTER DC OUT CONTROL Photocoupler OVER VOLTAGE PROTECTION Photocoupler PG(POWER GOOD) CONTROL TRANSFORMER RC(REMOTE ON/OFF) RECTIFIER AND FILTER AUX2(5V 1A) External view 134.5 0.5 [5.300.02] [0.67max] 115.6 0.5 15 10.5 CAUTION DOUBLE POLE/NEUTRAL FUSING [2.10] 18max [0.70max] [4.550.02] AIR FLOW M4 (Output(+),Output(-)) Tolerance 1 [0.04] Weight : 620g max Upper PCB Material/thickness : FR-4/1.6mm Lower PCB Material/thickness : FR-4/1.6mm Chassis Material/thickness : Aluminum/1.5mm Cover Material/thickness : Aluminum/1.2mm Fan cover Material : PBT Mounting torque : 1.5N m (14.7kgf cm) max Screw tightening torque M4 : 1.6N m (16.9kgf cm) max Dimensions in mm, [ ]=inches Mating connector Connector [0.37] [1.610.02] 165.3 [6.50] [0.60] 41 0.5 FG AC(N) AC(L) 53 [1.00] 6 [0.24] 17max [0.85] 10.5 [0.67] 8.6 [0.34] [3.35] 50.8 [2.00] 25.5 17 62.5 22.8 [0.90] 9.5 [2.46] 8 7 Output(+) Point A 85.2 2 1 Output(-) GHA CN501 21.6 [0.41] [0.92] M4 (AC,FG) Cover 2-M4 Mounting Holes (Bottom side) Name plate 23.3 [0.41] Output voltage adjust 2-M4 Mounting Holes SNF 087833-6320 51110-0851 50394-8051 SNFJ1 S8B-PHDSS 8 Mfr Molex * PHDR-08VS SPHD-002T-P0.5 J.S.T. *Please note the pin position No.1 is different from Molex. Pin No. 2 Terminal 1 7 CN501 Function 1 AUX1 : AUX1 (10V0.5A) 2 AUX1G : AUX1 (GND) 3 RC : REMOTE ON/OFF 4 RCG : REMOTE ON/OFF (GND) 5 PG : Power good 6 PGG : Power good (GND 7 AUX2 : AUX2 (5V1A) 8 AUX2G : AUX2 (GND) GHA-7 Ordering information AC-DC Power Supplies Medical Type GHA500F-SNF GH 1 A 2 500 3 F -OO -SNFO 4 Example recommended EMI/EMC filter EAC-10-472 R High voltage pulse noise type : EAP series Low leakage current type : EAM series * A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply. 5 6 1 Series name 2 Single output 3 Output wattage 4 Universal input 5 Output voltage 6 Optional *6 J1 : CN501 PH(J.S.T.)connector type P : Parallel Operation Refer to the instruction manual 5.1. *Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations. MODEL MAX OUTPUT WATTAGE[W] Forced air +50C DC OUTPUT GHA500F-12-SNF 450 12V 37.5A GHA500F-15-SNF 501 15V 33.4A GHA500F-24-SNF 504 24V 21.0A GHA500F-30-SNF 501 30V 16.7A GHA500F-48-SNF 504 48V 10.5A GHA500F-56-SNF 504 56V 9.0A SPECIFICATIONS MODEL VOLTAGE[V] CURRENT[A] ACIN 120V ACIN 230V FREQUENCY[Hz] ACIN 120V ACIN 230V ACIN 120V POWER FACTOR (Io=100%) ACIN 230V ACIN 120V INRUSH CURRENT[A] ACIN 230V LEAKAGE CURRENT[mA] VOLTAGE[V] CURRENT[A] Forced air LINE REGULATION[mV] *4 LOAD REGULATION[mV] *4 0 to +50C RIPPLE[mVp-p] *1 -20 - 0C 0 to +50C RIPPLE NOISE[mVp-p]*1 OUTPUT -20 - 0C 0 to +50C TEMPERATURE REGULATION[mV] -20 to +50C *2 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION[V] PROTECTION AUX1 CIRCUIT AND AUX2 OTHERS REMOTE ON/OFF PowerGood INPUT-OUTPUT-RC-AUX INPUT-FG ISOLATION OUTPUT-RC-AUX-FG OUTPUT-RC-AUX OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE ENVIRONMENT VIBRATION IMPACT INPUT EFFICIENCY[%] SAFETY AND AGENCY APPROVALS NOISE CONDUCTED NOISE REGULATIONS HARMONIC ATTENUATOR CASE SIZE/WEIGHT OTHERS COOLING METHOD GHA500F-12-SNF GHA500F-15-SNF GHA500F-24-SNF GHA500F-30-SNF GHA500F-48-SNF GHA500F-56-SNF AC90 - 264 1f (output derating is required at AC90V -115V *3) 5.4typ 4.8typ 2.9typ 2.6typ 50 / 60 (47 - 63) 87typ 89typ 89typ 89typ 89typ 89typ 89typ 91typ 91typ 91typ 91typ 91typ 0.95typ 0.90typ 20typ (Io=100%) (At cold start) (Ta=25C) 40typ (Io=100%) (At cold start) (Ta=25C) 0.125/0.250max (ACIN 120V/240V 60Hz,Io=100%, According to IEC60601-1) 12 15 24 30 48 56 37.5 33.4 21.0 16.7 10.5 9.0 48max 60max 96max 120max 192max 192max 100max 120max 150max 180max 240max 240max 240max 240max 240max 300max 300max 400max 320max 320max 320max 400max 400max 500max 300max 300max 300max 480max 480max 500max 360max 360max 360max 500max 500max 580max 120max 150max 240max 300max 480max 480max 150max 180max 290max 360max 600max 600max 48max 60max 96max 120max 192max 192max 500typ (ACIN 120V, Io=100%) 16typ (ACIN 120V, Io=100%) 13.50 to 16.50 21.60 to 26.40 27.00 to 31.50 43.20 to 52.80 52.00 to 56.00 10.80 to 13.20 15.00 to 15.30 24.00 to 24.96 30.00 to 31.20 48.00 to 49.92 55.00 to 56.00 12.00 to 12.48 Works over 105% of rating and recovers automatically *7 17.25 to 21.00 27.60 to 33.60 34.50 to 42.00 55.20 to 67.20 60.00 to 69.00 13.80 to 16.80 12V 0.5A 5V 1A Possible, AUX2 is available Open corrector AC4,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) 2MOPP AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) 1MOPP AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature) AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature) -20 to +70C, 20 - 90%RH (Non condensing), 3,000m (10,000feet) max *3 -30 to +80C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL60950-1, ANSI/AAMI ES60601-1, C-UL(CSA60950-1, CAN/CSA60601-1), EN60950-1, EN60601-1 3rd, Complies with DEN-AN, IEC60601-1-2 4th Ed. Complies with FCC-B, VCCI-B, CISPR11-B, CISPR22-B, EN55011-B, EN55022-B Complies with IEC61000-3-2 (class A) *5 85.2X41X165.3mm [3.35X1.61X6.5 inches] (WXHXD) / 660g max Forced air *1 This is the value that measured on measuring board with capacitor of 22mF at 150mm from output terminal. Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN: RM103). *2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. *3 Derating is required. *4 Please contact us about dynamic load and input response. GHA-8 *5 Please contact us about another class. *6 Specification is changed at option, refer to Instruction Manual. *7 When output current more than rated, output will shut down after 5 seconds or more. Recycle input after 3 minutes to reset the protection. * To meet the specifications. Do not operate over-loaded condition. * Sound noise may be generated by power supply in case of pulse load. * Parallel operation is available with -P option. Refer to 5.1on the instruction manual. GHA500F-SNF Features -Full packaged design united with GHA's features, and additional robustness.. -High efficiency 91% typ (Input voltage 230V,Output voltage 24V) -50% minimized size compares with previous products. -Optical for 1U applications -Medical and Industrial safety approvals -Low leakage current -Conformal coating -Single remote ON/OFF control for DC output, AUX1 and Fan. -Isolated dual AUX (AUX1 12V 0.5A, AUX2 5V 1A) Block diagram FUSE 250V10A AC IN 90 - 264V 2 BOOSTER INDUCTOR NOISE FILTER CURRENT SENSING INRUSH CURRENT LIMIT RECTIFIER INVERTER FG RECTIFIER AND FILTER CONTROL TRANSFORMER INVERTER CURRENT SENSING INTERNAL REGULATOR RECTIFIER AND FILTER AUX1(12V 0.5A) RECTIFIER AND FILTER DC OUT CONTROL Photocoupler OVER VOLTAGE PROTECTION Photocoupler PG(POWER GOOD) CONTROL TRANSFORMER RC(REMOTE ON/OFF) RECTIFIER AND FILTER AUX2(5V 1A) External view 134.5 0.5 [5.300.02] [0.67max] 115.6 0.5 15 10.5 CAUTION DOUBLE POLE/NEUTRAL FUSING [2.10] 18max [0.70max] [4.550.02] AIR FLOW M4 (Output(+),Output(-)) Tolerance 1 [0.04] Weight : 660g max Upper PCB Material/thickness : FR-4/1.6mm Lower PCB Material/thickness : AL/1.5mm Chassis Material/thickness : Aluminum/1.5mm Cover Material/thickness : Aluminum/1.2mm Fan cover Material : PBT Mounting torque : 1.5N m (14.7kgf cm) max Screw tightening torque M4 : 1.6N m (16.9kgf cm) max Dimensions in mm, [ ]=inches Mating connector Connector [0.37] [1.610.02] 165.3 [6.50] [0.60] 41 0.5 FG AC(N) AC(L) 53 [1.00] 6 [0.24] 17max [0.85] 10.5 [0.67] 8.6 [0.34] [3.35] 50.8 [2.00] 25.5 17 62.5 22.8 [0.90] 9.5 [2.46] 8 7 Output(+) Point A 85.2 2 1 Output(-) GHA CN501 21.6 [0.41] [0.92] M4 (AC,FG) Cover 2-M4 Mounting Holes (Bottom side) Name plate 23.3 [0.41] Output voltage adjust 2-M4 Mounting Holes SNF 087833-6320 51110-0851 50394-8051 SNFJ1 S8B-PHDSS 8 Mfr Molex * PHDR-08VS SPHD-002T-P0.5 J.S.T. *Please note the pin position No.1 is different from Molex. Pin No. 2 Terminal 1 7 CN501 Function 1 AUX1 : AUX1 (12V0.5A) 2 AUX1G : AUX1 (GND) 3 RC : REMOTE ON/OFF 4 RCG : REMOTE ON/OFF (GND) 5 PG : Power good 6 PGG : Power good (GND 7 AUX2 : AUX2 (5V1A) 8 AUX2G : AUX2 (GND) GHA-9 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Cosel: GHA300F-12 GHA300F-24 GHA300F-48 GHA500F-12 GHA500F-15 GHA500F-24 GHA500F-48