Conditions for operation,
transport and storage*8
(Not freezing and condens-
ing at low temperature)
Arrangement 1 Form A, 1 Form C
Contact material
UL/CSA rating 5 A 1/10 HP 125,
250 V AC
5 A 30 V DC
10 A 125 V AC
8 A 250 V AC
5 A 30 V DC
1/6 HP 125 V AC
1/3 HP 250 V AC
VDE rating
5 A 125 V ~ (cosϕ = 1.0)
2 A 250 V ~ (cosϕ = 1.0)
5 A 30 V —
…
10 A 125 V ~ (cosϕ = 1.0)
6 A 250 V ~ (cosϕ = 1.0)
5 A 30 V —
…
Silver alloy
Nominal switching capacity
Max. switching power
Max. switching voltage
Max. switching current
125 V AC, 30 V DC
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A) 50 mW
Expected
life (min.
operations)
Min. 5×106
Standard F type,
5 A Power J type,
10 A
5 A 125 V AC 10 A 125 V AC
625 VA 1,250 VA
5 A (AC/DC)
5 A (DC), 10 A (AC)
Contact
Coil
Nominal operating power 400 mW
Max. operating speed
Operate time*4
(at nominal voltage)(at 20°C)
Characteristics 20 cpm
Initial insulation resistance*1Min. 100 MΩ (at 500 V DC)
Min. 98 m/s2 {10 G}
Min. 980 m/s2 {100 G}
Functional*5
Destructive*6
Functional*7
Destructive
Approx. 10 ms
Release time (without diode)*4
(at nominal voltage)(at 20°C)
Approx. 10 ms
Surge voltage between
coil and contacts*3
Shock
resistance
Vibration
resistance
Min. 5,000 V
Max. 65°C with nominal coil voltage
across coil and at nominal switching capacity
Approx. 58.8 m/s2 {6 G}, 10 to 55 Hz
at double amplitude of 1 mm
Approx. 117.6 m/s2 {12 G}, 10 to 55 Hz
at double amplitude of 2 mm
Temperature rise(at 50°C)
Standard F type: Approx. 10 g .35 oz
Power J type: Approx. 11g .39 oz
Unit weight
Ambient
temp.
Humidity
Initial
break-
down
voltage*2
2,000 Vrms for 1 min.
–40°C to +50°C –40°F to +122°F
5 to 85%R.H.
Rating
(resistive
load)
Mechanical (at 180 cpm)
Electrical (at 20 cpm)
(at rated load) Min. 1×105
Between open contacts
Between contacts
and coil
800 Vrms for 1 min.
Remarks
*1 Measurement at same location as “Initial breakdown voltage” section
*2 Detection current: 10 mA
*3 Wave is standard shock voltage of ±1.2 × 50µs according to JEC-212-1981
*4 Excluding contact bounce time
*5 Half-wave pulse of sine wave: 11ms; detection time: 10µs
*6 Half-wave pulse of sine wave: 6ms
*7 Detection time: 10µs
*8 Refer to 5. Conditions for operation, transport and storage mentioned in
*7 AMBIENT ENVIRONMENT (Page 49)
NSF1JY B
Contact
arrangement
1: 1 Form C
1a: 1 Form A F: Standard (5 A)
J: Power (10 A) Nil: Flux-resistant
type
S: Sealed type
N: 70% of nominal voltage Nil: Class A type
B: Class B type DC 5, 6, 9,
12, 24, 48 V
Protective
construction
Contact capacity Pick-up voltage Coil type Coil voltage
Note: Standard packing: Carton 100 pcs. Case 500 pcs.
DC24V
UL File No.: E43028
CSA File No.: LR26550
ORDERING INFORMATION
2. Office machines
Photocopiers, facsimiles, power source
equipment, etc.
3. Automotive
Car-stereo, car antenna, car-wiper, etc.
1. Home appliances
Air conditioners, refrigerators, etc.