12-28-98
SB98107 Rev. A
Sentry SEN
Sur ge Protector with Replaceable Fuses
Sentry ECF-5
Replacement Fuses
Form No. SEN
Page 1 of 1
BIF Doc #7001
Bussmann®
Dimensional Data
0.300
2X
0.768
0.252
0.504
0.625
1.250
1.300 1.560
1.040
1.630
Electrical Circuit Diagram
BUSS ECF
H
G
N
MOV
14mm
65J
150V
47K R
NEON
Buss
Buss
®
LR104482
R
R
LR104482
CATALOG SYMBOL: SEN
TRANSIENT VOLTAGE SPIKE PROTECTOR
RATED VOLTAGE: 125 VOLTS AC
SURGE DISSIPATION: 65 JOULES
PEAK SURGE: 6,000 VOLTS
MAXIMUM SURGE: 4,500 VOLTS
RESPONSE TIME: 1 NANOSECOND
CLAMPING VOLTAGE: 395 VOLTS
AGENCY APPROVAL: CSA CERTIFIED, LR104482
For use with Buss ECF-5, 125 VAC, 5 Amp Fuses.
WARNING: FOR INDOOR USE ONLY.
CATALOG SYMBOL: ECF-5
REPLACEMENT FUSES
VOLTAGE RATING: 125 VAC
INTERRUPTING RATING: 10,000 AIR
AGENCY APPROVALS: U.L. LISTED
Dual protection against voltage surges and short-circuits.
Compact size - easy to carry.
Indicator light - glows to show that Sentry is ready.
Compact design provides wall-hugging connection.
Replaceable fuses.
Sentry can be used with all household appliances and elec-
tronics up to 4 Amps. Including Lap-top Computers, TVs,
VCRs, telephones, answering machines, stereos, and similar
devices.
NOTE: Sentry is NOT a lightning arrestor and will not pro-
vide protection against direct or nearby lightning strikes.