MB High Voltage Series Vishay High Power Products Single Phase Bridge (Power Modules), 25 A/35 A FEATURES * Universal, 3 way terminals: push-on, wrap around or solder * High thermal conductivity package, electrically insulated case RoHS COMPLIANT * Center hole fixing * Excellent power/volume ratio * Nickel plated terminals solderable using lead (Pb)-free solder; solder alloy Sn/Ag/Cu (SAC305); solder temperature 260 to 275 C D-34 * UL E300359 approved * RoHS compliant * Designed and qualified for industrial and consumer level PRODUCT SUMMARY IO DESCRIPTION A range of extremely compact, encapsulated single phase bridge rectifiers offering efficient and reliable operation. They are intended for use in general purpose and instrumentation applications. 25 A/35 A MAJOR RATINGS AND CHARACTERISTICS SYMBOL CHARACTERISTICS IO IFSM I2 t VRRM 26MB-A 36MB-A UNITS 25 35 A C TC 70 55 50 Hz 400 475 60 Hz 420 500 50 Hz 790 1130 60 Hz 725 1030 Range 1400 to 1600 1400 to 1600 V - 55 to 150 - 55 to 150 C TJ A A2s ELECTRICAL SPECIFICATIONS VOLTAGE RATINGS TYPE NUMBER VOLTAGE CODE VRRM, MAXIMUM REPETITIVE PEAK REVERSE VOLTAGE V VRSM, MAXIMUM NON-REPETITIVE PEAK REVERSE VOLTAGE V 26MB..A 36MB..A 140 1400 1500 160 1600 1700 Document Number: 93564 Revision: 17-Jun-08 For technical questions, contact: ind-modules@vishay.com IRRM MAXIMUM AT TJ MAXIMUM mA 2 www.vishay.com 1 MB High Voltage Series Single Phase Bridge (Power Modules), 25 A/35 A Vishay High Power Products FORWARD CONDUCTION PARAMETER SYMBOL Maximum DC output current at case temperature IO 26MB-A 36MB-A Resistive or inductive load TEST CONDITIONS 25 35 Capacitive load 20 28 65 60 400 475 420 500 335 400 t = 10 ms Maximum peak, one cycle non-repetitive forward current IFSM t = 8.3 ms t = 10 ms t = 8.3 ms t = 10 ms Maximum I2t for fusing t = 8.3 ms I2t t = 10 ms t = 8.3 ms Maximum I2t for fusing I2t No voltage reapplied 100 % VRRM reapplied No voltage reapplied Initial TJ = TJ maximum 100 % VRRM reapplied 350 420 790 1130 725 1030 560 800 512 730 I2t for time tx = I2t x tx; 0.1 tx 10 ms, VRRM = 0 V 5.6 11.3 Low level of threshold voltage VF(TO)1 (16.7 % x x IF(AV) < I < x IF(AV)), TJ maximum 0.70 0.74 High level of threshold voltage VF(TO)2 (I > x IF(AV)), TJ maximum 0.75 0.79 UNITS A C A A2 s kA2s V Low level forward slope resistance rt1 (16.7 % x x IF(AV) < I < x IF(AV)), TJ maximum 7.0 5.5 High level forward slope resistance rt2 (I > x IF(AV)), TJ maximum 6.4 5.2 1.25 1.3 V 10 10 A 2700 2700 V Maximum forward voltage drop VFM TJ = 25 C, IFM = 40 Apk (26MB) TJ = 25 C, IFM = 55 Apk (36MB) Maximum DC reverse current per diode IRRM TJ = 25 C, at VRRM RMS isolation voltage base plate VISOL f = 50 Hz, t = 1 s tp = 400 s m THERMAL AND MECHANICAL SPECIFICATIONS PARAMETER Junction and storage temperature range SYMBOL 26MB-A TJ, TStg Maximum thermal resistance, junction to case per bridge RthJC Maximum thermal resistance, case to heatsink RthCS Mounting torque 10 % TEST CONDITIONS - 55 to 150 1.7 UNITS C 1.35 K/W Mounting surface, smooth, flat and greased 0.2 Bridge to heatsink 2.0 Nm 20 g Approximate weight www.vishay.com 2 36MB-A For technical questions, contact: ind-modules@vishay.com Document Number: 93564 Revision: 17-Jun-08 MB High Voltage Series 1000 Instantaneous Forward Current (A) 150 26MB..A Series 130 110 180 (Rect) 90 180 (Sine) 70 Tj = 150C 100 0 5 10 15 20 25 Tj = 25C 10 26MB..A Series 1 0.5 50 30 1 1.5 2 2.5 3 3.5 Average Forward Current (A) Instantaneous Forward Voltage (V) Fig. 1 - Current Ratings Characteristics Fig. 2 - Forward Voltage Drop Characteristics 50 26MB..A Series Tj = 150C 180 (Sine) = R 20 3K /W 4K /W 5K /W ta el -D 180 (Rect) 30 K/ W W K/ 2 1 40 A hS Rt Maximum Average Forward Power Loss (W) Maximum Allowable Case temperature (C) Single Phase Bridge Vishay High Power Products (Power Modules), 25 A/35 A 7 K/W 10 10 K /W 0 0 5 10 15 20 Average Forward Current (A) 25 0 25 50 75 100 125 150 Maximum Allowable Ambient Temperature (C) 400 Peak Half Sine Wave Forward Current (A) Peak Half Sine Wave Forward Current (A) Fig. 3 - Total Power Loss Characteristics At Any Rated Load Condition And With Rated Vrrm Applied Following Surge Initial Tj = 150C @ 60 Hz 0.0083 s @ 50 Hz 0.0100 s 350 300 250 200 150 26MB..A series 100 1 10 100 450 Maximum Non Repetitive Surge Current Versus Pulse Train Duration. Initial Tj = 150 C No Voltage Reapplied 350 Rated Vrrm Reapplied 250 150 26MB..A Series 50 0.01 Fig. 4 - Maximum Non-Repetitive Surge Current Document Number: 93564 Revision: 17-Jun-08 0.1 1 Pulse Train Duration (s) Number of Equal Amplitude Half Cycle Current Pulses (N) Fig. 5 - Maximum Non-Repetitive Surge Current For technical questions, contact: ind-modules@vishay.com www.vishay.com 3 MB High Voltage Series Single Phase Bridge (Power Modules), 25 A/35 A 1000 Instantaneous Forward Current (A) 150 36MB..A Series 130 110 180 (Rect) 90 180 (Sine) 70 Tj = 150C 100 10 0 5 10 15 20 25 30 35 Tj = 25C 36MB..A Series 1 0.5 50 40 1 1.5 2 2.5 3 3.5 Average Forward Current (A) Instantaneous Forward Voltage (V) Fig. 6 - Current Ratings Characteristics Fig. 7 - Forward Voltage Drop Characteristics Maximum Average Forward Power Loss (W) Maximum Allowable Case temperature (C) Vishay High Power Products 80 36MB..A Series Tj = 150C Rt hS A 180 (Sine) 60 180 (Rect) 40 = 1K /W 2K /W 0. 7 K/ W -D elt a R 3K /W 4 K/W 5 K/W 20 7 K/W 0 0 5 10 15 20 25 30 Average Forward Current (A) 35 0 25 50 75 100 125 150 Maximum Allowable Ambient Temperature (C) 450 At Any Rated Load Condition And With Rated Vrrm Applied Following Surge. Initial Tj = 150C @ 60 Hz 0.0083 s @ 50 Hz 0.0100 s 400 350 300 250 200 150 36MB..A Series 100 1 10 100 Peak Half Sine Wave Forward Current (A) Peak Half Sine Wave Forward Current (A) Fig. 8 - Total Power Loss Characteristics 500 Maximum Non Repetitive Surge Current Versus Pulse Train Duration. Initial Tj = 150C No Voltage Reapplied 400 Rated Vrrm Reapplied 450 350 300 250 200 150 36MB..A Series 100 0.01 Fig. 9 - Maximum Non-Repetitive Surge Current www.vishay.com 4 0.1 1 Pulse Train Duration (s) Number of Equal Amplitude Half Cycle Current Pulses (N) Fig. 10 - Maximum Non-Repetitive Surge Current For technical questions, contact: ind-modules@vishay.com Document Number: 93564 Revision: 17-Jun-08 MB High Voltage Series Single Phase Bridge Vishay High Power Products (Power Modules), 25 A/35 A ORDERING INFORMATION TABLE Device code 36 MB 160 A 1 2 3 4 26 = 25 A (average) 36 = 35 A (average) 1 - Current rating code 2 - Circuit configuration: MB = Single phase european coding 3 - Voltage code x 10 = VRRM 4 - Diode bridge rectifier: A = 26 MB, 36MB series CIRCUIT CONFIGURATION + ~ - LINKS TO RELATED DOCUMENTS Dimensions Document Number: 93564 Revision: 17-Jun-08 http://www.vishay.com/doc?95326 For technical questions, contact: ind-modules@vishay.com www.vishay.com 5 Outline Dimensions Vishay Semiconductors D-34 DIMENSIONS in millimeters (inches) 0.8 0.05 (0.03 0.002) 6.35 0.1 (0.25 0.004) 10.5 0.15 (0.41 0.006) 20.3 0.15 (0.80 0.006) - ~ 21.5 + 1.0 - 0.5 + 0.039 (0.85 ) - 0.020 28.5 0.15 (1.12 0.006) 9.5 0.5 (0.37 0.020) 12.7 0.1 (0.5 0.004) + ~ 5.25 0.15 (0.21 0.006) 12.7 0.1 (0.5 0.004) 28.5 0.15 (1.12 0.006) Not to scale Suggested plugging force: 200 N max; axially applied to fast-on terminals Document Number: 95326 Revision: 07-Jul-08 For technical questions, contact: indmodules@vishay.com www.vishay.com 1 Legal Disclaimer Notice www.vishay.com Vishay Disclaimer ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE. Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, "Vishay"), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merchantability. Statements regarding the suitability of products for certain types of applications are based on Vishay's knowledge of typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements about the suitability of products for a particular application. It is the customer's responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All operating parameters, including typical parameters, must be validated for each customer application by the customer's technical experts. Product specifications do not expand or otherwise modify Vishay's terms and conditions of purchase, including but not limited to the warranty expressed therein. Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining applications or for any other application in which the failure of the Vishay product could result in personal injury or death. Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk and agree to fully indemnify and hold Vishay and its distributors harmless from and against any and all claims, liabilities, expenses and damages arising or resulting in connection with such use or sale, including attorneys fees, even if such claim alleges that Vishay or its distributor was negligent regarding the design or manufacture of the part. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners. Material Category Policy Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as RoHS-Compliant fulfill the definitions and restrictions defined under Directive 2011/65/EU of The European Parliament and of the Council of June 8, 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment (EEE) - recast, unless otherwise specified as non-compliant. Please note that some Vishay documentation may still make reference to RoHS Directive 2002/95/EC. We confirm that all the products identified as being compliant to Directive 2002/95/EC conform to Directive 2011/65/EU. Revision: 12-Mar-12 1 Document Number: 91000