Data Sheet PRM-4 Phase Sequence and Motor Rotation Tester Identifies 3-phase sequence and open phase check Motor shaft rotation indication protected by CAT III circuitry CAT III 600V rated for both testing segments Meets current EN61010 safety requirements, CSA, EN61557-7 Supplied with three CAT III rated color coded large alligator clips and test leads Zippered carrying case for portability No hassle warranty No waiting. No shipping charges. Our commitment to high-quality products and customer service is demonstrated by our industry exclusive "No Hassle" warranty. In the unlikely event that an Amprobe Test Tool requires warranty service, any of our local dealers are authorized to replace it, on the spot. Included Accessories Test Leads (red, green, and blue) with alligator clips (TL-PRM-4), Soft Vinyl Case, Users Manual, 9 V Battery Optional Accessories TL-PRM-4 Replacement Test Leads FP900 Replacement Fuses (note: $500 MSLP limit) 600V Amprobe(R) Test Tools www.Amprobe.com PRM-4 Phase Sequence and Motor Rotation Tester General Specifications Operating Environment Power Battery life Low battery indication Dimensions (H x W x D) Weight Environment Altitude Overload protection Agency Approvals Safety EMC Data Sheet 0 C to 40 C at <80 % R.H. Single standard 9 V battery NEDA 1604 JIS 006P IEC 6F22 Approximately 200 hours typical with carbon-zinc battery The BATT LED does not come ON when TEST button is pressed 153 mm x 72 mm x 35 mm (6.02 x 2.83 x 1.37 in) Approximately 218 g (7 oz) including battery. Indoor use 2000 m (6561 ft.) 600 V ac CE, cCSAus Conforms to EN61010-1:2001 CAT III 600V, Pollution degree 2, Class 2 CSA 22.2 -1010-1 EN61557-7 Conforms to EN61326-1. This product complies with requirements of the following European Community Directives: 89/ 336/ EEC (Electromagnetic Compatibility) and 73/ 23/ EEC (Low Voltage) as amended by 93/ 68/ EEC (CE Marking). However, electrical noise or intense electromagnetic fields in the vicinity of the equipment may disturb the measurement circuit. Measuring instruments will also respond to unwanted signals that may be present within the measurement circuit. Users should exercise care and take appropriate precautions to avoid misleading results when making measurements in the presence of electronic interference. Electrical Specifications Function Phase Sequence Input Voltage Frequency Operating Time 3-Phase load Motor Rotation Operating Time Motor Rotation tester field Amprobe(R) Test Tools website: www.Amprobe.com email: info@amprobe.com Everett, WA 98203 Tel: 877-AMPROBE Amprobe(R) Test Tools Range 3 phase to phase inputs 100 V ac to 600 V ac max. 45 to 70 Hz 10 minutes ON maximum at 600 V ac 10 minutes OFF minimum at 600 V ac Approx. 7 mA per phase of ac power source 10 minutes ON maximum 10 minutes OFF minimum. 14 mA of 9 V battery Amprobe(R) Test Tools Europe In den Engematten 14 79286 Glottertal, Germany Tel.: +49 (0) 7684 8009 - 0 (c)2008 Amprobe Test Tools. All rights reserved. 2/2008 3303533 Rev A www.Amprobe.com