cui.com
date 02/21/2020 │ page 2 of 6CUI Inc │ SERIES: SDI200G-U │ DESCRIPTION: AC-DC POWER SUPPLY
INPUT
parameter conditions/description min typ max units
voltage 100 240 Vac
frequency 50 60 Hz
current 2.4 A
inrush current at240Vac,fullload,25°C,coldstart 100 A
leakage current 3.5 mA
no load power consumption at 115 & 230 Vac 0.21 W
OUTPUT
parameter conditions/description min typ max units
regulation ±5 %
PROTECTIONS
parameter conditions/description min typ max units
over voltage protection output shut down and latch 180 %
over current protection outputshutdownandautomaticrecovery 180 %
short circuit protection outputshutdownandautomaticrecovery
over temperature protection output shut down and latch
SAFETY & COMPLIANCE
parameter conditions/description min typ max units
isolation voltage input to output at 10 mA for 1 minute 3,000 Vac
isolation resistance input to output at 500 Vdc 10 MΩ
safetyapprovals UL/cUL (62368-1)
EMI/EMC FCCPart15BClassB,CE
MTBF asperTelcordiaSR-332,25°C 300,000 hours
RoHS 2011/65/EU
ENVIRONMENTAL
parameter conditions/description min typ max units
operating temperature 0 40 °C
storage temperature -20 80 °C
operatinghumidity non-condensing 20 80 %
storagehumidity non-condensing 10 90 %
Additional Resources: Product Page