T810S-T004E E L E C T R O N I C S HJR1-2C DPDT configuration High sensitivity DIP standard terminals Sealed version u s E173485 c Surge strength 1500V FCC68 R50116175 -Clearance more than 1.2 mm between coil and contacts -Creepage more than 1.9 mm between coil and contacts Conform to RoHS,ELV directive ORDERING CODE HJR1-2C 1 D -- 12VDC 2 3 1. Relay Model 2. Coil Power 3. Coil Nominal Voltage 3,5,6,9,12,24,48VDC N=0.45W, D=0.36W, L=0.2W, M=0.15W COIL DATA at 20 Nominal Voltage(VDC) 3 5 6 9 12 24 Coil Resistance() 60 167 240 540 960 3840 Rated Current(mA) 50 29.9 25 16.7 12.5 6.25 Max Operate Voltage (VDC) 2.4 4 4.8 7.2 9.6 19.2 Min Release Voltage(VDC) 0.15 0.25 0.3 0.45 0.6 1.2 Coil Resistance() 45 125 180 405 720 2880 11520 Rated Current(mA) 66.7 40 33.3 22.2 16.7 8.3 4.2 Max Operate Voltage (VDC) 2.25 3.75 4.5 6.75 9 18 36 Min Release Voltage(VDC) 0.3 0.5 0.6 0.9 1.2 2.4 4.8 Coil Resistance() 25 70 100 220 400 1600 6400 Rated Current(mA) 120 72 60 40 30 15 85 Max Operate Voltage (VDC) 2.25 3.75 4.5 6.75 9 18 36 Min Release Voltage(VDC) 0.3 0.5 0.6 0.9 1.2 2.4 4.8 Coil Resistance() 20 56 80 180 320 1280 5100 Rated Current(mA) 150 89.2 75 50 37.5 18.7 10.6 Max Operate Voltage (VDC) 2.25 3.75 4.5 6.75 9 18 36 Min Release Voltage(VDC) 0.3 0.5 0.6 0.9 1.2 2.4 4.8 Max ApplicableVoltage 70130%23170% 3-24VDC 10%48VDC 15% 48 0.15W 0.2W 0.36W 0.45W CONTACT DATA Contact Form 2Z Contact Material Silver Alloy Load Contact Resistive load(COS=1) 1A 120VAC Ratings 2A 24VDC Minimum load 1mA 5VDC Max Switching Voltage 240VAC/60VDC Max Switching Current 2A Max Switching Power 120VA/60W Contact Resistance 100mMax at 6VDC 1A Electrical : 100,000 Operations(at30Operations/minute) Life Expectancy Mechanical: 10,000,000 Operations(at300Operations/minute) CHARACTERISTICS DATA Insulation Resistance 100MMin at 500VDC Dielectric Strength Between Open Contacts 500VAC( for one minute) Between Contacts and coil 1000VAC( for one minute) Operate Time 8ms Max Release Time 4ms Max Temperature Range -30to+85 Operating Extremes: 10G Shock Resistance Damage Limits: 50G Vibration Resistance 10-55Hz, 1.5mm Max. switching frequency Mechanical:18,000operations/hr Electrical:1,800operations/hr Humidity 40-85% Weight Approx 5g Safety Standard UL cUL TUV APPROVED STANDARDS Model() Coiling rating Safety Standard TUV HJR1-2C 3 to 48VDC UL/cUL Contact rating 0.5A 120VAC 1A 24VDC 1A 120VAC 2A 24VDC ENGINEERING DATA Contact Switching Capacity Timing 3 Contact current(A) 8 6 Time(ms) Operation time 4.5 3.0 Release time 1.5 2 DC Resistive 1 AC Resistive 0.5 0.3 Coil Power(w) Contact voltage(V) Amblent Temperature vs.Maximum Voitage Life expectancy 1000 Maximum Voitage Operation(X1000) 500 24VDC resistive load 300 120VAC resistive load 100 70 50 30 5 . 0 1 1.5 2 3 4 5 6 7 Ambient temperature Contact Current(A) OVERALL AND MOUNTING DIMENSIONS 1 4 6 8 16 13 11 9 11mm 0.2mm 1~5mm 0.3mm 5mm 0.4mm 20.1mm